Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation of test systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced climate reproducibility testing with false discovery rate correction

Simulating the Earth's climate is an important and complex problem, thus climate models are similarly complex, comprised of millions of lines of code. In order to appropriately utilize the latest computational and software infrastructure advancements in Earth system models running on modern hybrid computing architectures to improve their performance, precision, accuracy, or all three; it is important to ensure that model simulations are repeatable and robust. This introduces the need for establishing statistical or non-bit-for-bit reproducibility, since bit-for-bit reproducibility may not always be achievable. Here, we propose a short-simulation ensemble-based test for an atmosphere model to evaluate the null hypothesis that modified model results are statistically equivalent to that of the original model. We implement this test in version 2 of the US Department of Energy's Energy Exascale Earth System Model (E3SM). The test evaluates a standard set of output variables across the two simulation ensembles and uses a false discovery rate correction to account for multiple testing. The false positive rates of the test are examined using re-sampling techniques on large simulation ensembles and are found to be lower than the currently implemented bootstrapping-based testing approach in E3SM. We also evaluate the statistical power of the test using perturbed simulation ensemble suites, each with a progressively larger magnitude of change to a tuning parameter. The new test is generally found to exhibit more statistical power than the current approach, being able to detect smaller changes in parameter values with higher confidence.

Kelleher, Michael E. [Oak Ridge National Laborator↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

In-Transit Data Transport Strategies for Coupled AI-Simulation Workflow Patterns

Coupled AI-Simulation workflows are becoming the major workloads for HPC facilities, and their increasing complexity necessitates new tools for performance analysis and prototyping of new in-situ workflows. We present SimAI-Bench, a tool designed to both prototype and evaluate these coupled workflows. In this paper, we use SimAI-Bench to benchmark the data transport performance of two common patterns on the Aurora supercomputer: a one-to-one workflow with co-located simulation and AI training instances, and a many-to-one workflow where a single AI model is trained from an ensemble of simulations. For the one-to-one pattern, our analysis shows that node-local and DragonHPC data staging strategies provide excellent performance compared Redis and Lustre file system. For the many-to-one pattern, we find that data transport becomes a dominant bottleneck as the ensemble size grows. Our evaluation reveals that file system is the optimal solution among the tested strategies for the many-to-one pattern.

Tummalapalli, Harikrishna [Argonne National Labora↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state,1 and to rapidly recover operational capabilities for essential functions after a successful attack.2 The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.”3 As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

TEAMER – Harvesting Subsea Water Motion to Provide Clean Electrical Power (Abstract)

Power generation from vortex induced vibration (VIV) is an emerging field with new technologies that are just beginning to be field tested. In this TEAMER project, WITT Energy will be field testing the power production of its pendulum system in two different configurations to evaluate its performance. The amount of power produced by a VIV instrument depend on the frequency at which it vibrates. The vibrational frequency is controlled by the device shape and its interaction with the flow velocity. Computer models are used to predict vibration frequencies as a function of flow velocity but they may be inaccurate due to complicated bathymetry and bottom roughness that is not captures by the models. This project will test the WITT VIV device in the Sequim Bay channel over a range of tidal velocities. Two tests will be completed with different pipe lengths that are expected to vary the vibrational frequency and therefore the power produced. PNNL will use an acoustic doppler current profiler (ADCP) to monitor the flow conditions during the tests. These tests will help WITT Energy evaluate how closely field operations follow computer model predictions and how best to configure their device for electricity production.

16 TIDAL AND WAVE POWER↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.

03 NATURAL GAS↗

ECAR-8446 Rev 0 MARVEL BPVC Section III Division 5 HBB Fatigue Acceptance Tests

The objective of this analysis is to evaluate the fatigue and creep behavior of 316 SS materials used in the Primary Coolant System (PCS) and Guard Vessel System (GVS) for the first two years of MARVEL reactor operation. The analysis follows the requirements set forth in ASME BPVC Section III, Division 5, HBB-2800, which mandates a fatigue test if operational conditions exceed allowable thresholds. By determining whether the materials meet the HBB-T-1324(a) and HBB-T-1324(b) criteria, this evaluation establishes whether a fatigue test is necessary, as well as the maximum allowable operational hours and temperatures before fatigue testing would be required. The deliverables of this analysis include calculations validating compliance with fatigue acceptance criteria, determination of maximum operational limits for the two-year period, and identification of conditions under which a fatigue test would be necessary. This ensures that the PCS and GVS can operate safely without premature material degradation and align with the design life requirements outlined in SPC-70731. Additionally, this evaluation provides conservative estimates for Service Level B occurrences and their impact on allowable Service Level A hours and temperatures, offering guidance for future operational assessments and potential life extensions beyond the initial two-year period.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES↗

Quantum Computing for AI-based Design and Optimization of Electric Motors

Knowledge-based artificial intelligence and hierarchical fuzzy logic offer an interpretable framework for electricvehicle motor preliminary design, but their computational burden grows with linguistic granularity and coupled design-space size. This paper presents a reduced quantum reformulation of the hierarchical fuzzy inference of air-gap flux density, a representative level-one motor-design parameter. Starting from the published electric-vehicle motor-design framework, a three-term fuzzy prototype is constructed from the original inference structure. The reduced model is then reformulated as a modular quantum register-oracle system, in which each hierarchical subrelation is encoded as a block oracle and evaluated through superpositionbased candidate-label testing. The proposed modular quantum formulation reproduces the reduced classical prototype after block fusion. A resource analysis shows that the reduced modular system requires seven qubits per block and twenty-two qubits in a straightforward four-block implementation. Finally, a crossovercomplexity model is derived to identify the regime in which quantum candidate search may become favorable relative to hierarchical fuzzy inference. The results show that no quantum advantage should be claimed for the present one-output reduced benchmark, but that a plausible crossover emerges for larger joint candidate spaces and higher linguistic granularity. The work therefore establishes a technically consistent starting point for future quantum-assisted electric-vehicle motor-design optimization.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

Fabrication and Testing of Solid-Solution Strengthened Corrosion Resistant Alloys For Service in Molten Fluoride Environments

The demand for higher system thermal efficiencies requires the operation of power generation cycles and heat conversion systems at progressively higher temperatures. As the system operating temperature increases, existing materials may not provide adequate mechanical properties or environmental compatibility or both. There is an increasing commercial interest in the development and deployment of liquid-fueled Molten Salt Reactors (MSRs). Hastelloy®N, the highest performing candidate MSR structural alloy, is not capable of operations at temperatures above 700°C, thus limiting the performance of these systems. Using an Integrated Computational Materials Engineering (ICME)-approach and small laboratory scale heats, ORNL developed a class of patented alloys covered by U.S. Patent 9, 435, 011 B2, “Creep-resistant, Cobalt-free alloys for high temperature, liquid-salt heat exchanger systems,” similar to Hastelloy®N in that they are primarily solid solution strengthened. In contrast to precipitation strengthened alloys, the microstructure of solid solution alloys and hence the high temperature mechanical properties are stable for extended periods of time allowing long reactor operating life. The new alloys have shown to possess good resistance to liquid fluorides at temperatures up to 850°C and have significantly improved creep properties when compared to Hastelloy®N. The purpose of the CRADA project was for ORNL to collaborate with Haynes International- a materials producer, MetalTek International- a foundry, and Kairos Power – an advanced reactor developer – to scale-up selected alloys, evaluate their properties, and identify one solid solution strengthened alloy that can meet the property requirements for the reactor being developed by Kairos Power and other similar liquid fluoride-salt cooled reactors. As part of the project, eight alloys were down-selected and fabricated in larger industrial scale heats by Haynes International. Resistance to molten salt was evaluated in flowing FLiNaK and FLiBe by Kairos Power using their Rotating Cage Loop (RCL) system. Accounting for iron deposition during these tests, the new alloys displayed very low net mass change showing excellent corrosion performance in molten salt. Creep properties evaluated at ORNL were found to be better than that of Hastelloy®N and 316 stainless steel. Long-term stabilities of the alloys evaluated by Haynes International showed that these alloys have excellent thermal stability in the temperature range 704.4-815.6°C, with the change in strength and ductility being less than 10-15% after a 4000-hour exposure at 815.6°C. Autogenously Gas Tungsten Arc Welding (GTAW) welded samples showed less than 10% change in yield strength / ultimate tensile strength / total elongation compared to the basemetal, indicating that the alloys have excellent weldability. Three parts were successfully investment-cast using one alloy with very little voiding showing feasibility of fabricating parts using the casting process. This project enabled extensive interaction between the material producer Haynes International, casting supplier MetalTek, and reactor developer Kairos Power. This facilitated testing of materials and components produced using the newly developed alloys by the end-user. This allowed the generation of critical dataset required for down-selection of a few promising alloys for further development. This data is also currently being shared with other reactor designers for them to evaluate the suitability of this alloy for their reactor design. The availability of this alloy will ultimately enable the design and development and deployment of MSRs with increased temperature of operation and thus, improved efficiencies.

99 GENERAL AND MISCELLANEOUS↗

Fabrication and Testing of Solid-Solution Strengthened Corrosion Resistant Alloys For Service in Molten Fluoride Environments

The demand for higher system thermal efficiencies requires the operation of power generation cycles and heat conversion systems at progressively higher temperatures. As the system operating temperature increases, existing materials may not provide adequate mechanical properties or environmental compatibility or both. There is an increasing commercial interest in the development and deployment of liquid-fueled Molten Salt Reactors (MSRs). Hastelloy®N, the highest performing candidate MSR structural alloy, is not capable of operations at temperatures above 700°C, thus limiting the performance of these systems. Using an Integrated Computational Materials Engineering (ICME)-approach and small laboratory scale heats, ORNL developed a class of patented alloys covered by U.S. Patent 9,435,011 B2, “Creep-resistant, Cobalt-free alloys for high temperature, liquid-salt heat exchanger systems,” similar to Hastelloy®N in that they are primarily solid solution strengthened. In contrast to precipitation strengthened alloys, the microstructure of solid solution alloys and hence the high temperature mechanical properties are stable for extended periods of time allowing long reactor operating life. The new alloys have shown to possess good resistance to liquid fluorides at temperatures up to 850°C and have significantly improved creep properties when compared to Hastelloy®N. The purpose of the CRADA project was for ORNL to collaborate with Haynes International- a materials producer, MetalTek International- a foundry, and Kairos Power – an advanced reactor developer – to scale-up selected alloys, evaluate their properties, and identify one solid solution strengthened alloy that can meet the property requirements for the reactor being developed by Kairos Power and other similar liquid fluoride-salt cooled reactors. As part of the project, eight alloys were down-selected and fabricated in larger industrial scale heats by Haynes International. Resistance to molten salt was evaluated in flowing FLiNaK and FLiBe by Kairos Power using their Rotating Cage Loop (RCL) system. Accounting for iron deposition during these tests, the new alloys displayed very low net mass change showing excellent corrosion performance in molten salt. Creep properties evaluated at ORNL were found to be better than that of Hastelloy®N and 316 stainless steel. Long-term stabilities of the alloys evaluated by Haynes International showed that these alloys have excellent thermal stability in the temperature range 704.4-815.6°C, with the change in strength and ductility being less than 10-15% after a 4000-hour exposure at 815.6°C. Autogenously Gas Tungsten Arc Welding (GTAW) welded samples showed less than 10% change in yield strength / ultimate tensile strength / total elongation compared to the basemetal, indicating that the alloys have excellent weldability. Three parts were successfully investment-cast using one alloy with very little voiding showing feasibility of fabricating parts using the casting process. This project enabled extensive interaction between the material producer Haynes International, casting supplier MetalTek, and reactor developer Kairos Power. This facilitated testing of materials and components produced using the newly developed alloys by the end-user. This allowed the generation of critical dataset required for down-selection of a few promising alloys for further development. This data is also currently being shared with other reactor designers for them to evaluate the suitability of this alloy for their reactor design. The availability of this alloy will ultimately enable the design and development and deployment of MSRs with increased temperature of operation and thus, improved efficiencies.

36 MATERIALS SCIENCE↗

The role of moisture in MgCl 2 salt: A multiscale approach to TES performance

This study presents a comprehensive multiscale analysis to evaluate the influence of moisture on the thermal performance of thermal energy storage systems using magnesium chloride (MgCl 2 ) as the phase-changing material. The system uses graphite foam with 90% relative density to enhance thermal conductivity. The analysis includes thermal conductivity calculations and specific heat capacity for different hydrate phases of MgCl 2 : Anhydrous, Mono, Di, Tetra, and Hexa. These properties were evaluated for the first time using the phonon density of states from Density Functional Theory simulations. Results showed that thermal conductivity decreased, while specific heat capacity increased by a factor of two as the phase changed from anhydrous to hexahydrate. Meso-scale models were created to account for the anisotropy of graphite foam and property variations of the MgCl 2 hydrate phases. Asymptotic Expansion homogenization simulations determined the anisotropic thermal conductivity for all phases. This unique methodology improved simulation accuracy, which matched experimental data for anhydrous MgCl 2 . A parametric study examined various operating conditions and their effect on TES performance. It revealed that higher charging temperatures did not enhance exergy efficiency, but increased discharge mass flow rates improved it due to better heat transfer. Thermal performance evaluated by the exergy efficiency remained consistent across hydrate systems under the tested conditions. Furthermore, the study suggests that this uniformity is linked to missing key data, particularly latent heat and melting point for different hydrates. Overall, it highlights the importance of multiscale effects and accurate material properties in designing and optimizing TES systems.

Molten salt degradation↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Feature Based Qualification (FBQ) of Wire Arc Additively Manufactured (WAAM) 17-4PH Martensitic Stainless Steels

The Department of Defense (DOD) programs of records desire to reduce the time and cost of the development and delivery loop in metal additive manufacturing (AM), including establishing forwarded AM capabilities. The success of these efforts relies on a robust and qualified process. To achieve this, the United States Army Combat Capabilities Development Command Ground Vehicle Systems Center Materials Engineering (GVME) needs to be able to quickly evaluate, test, and develop feedstocks, processes, and parts. This report is directed towards demonstrating the need for a framework for metal AM processes, defining and exploring geometries for metal AM process qualification, testing resultant deposition, and delivering actionable data.

36 MATERIALS SCIENCE↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗