Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Soil temperature extrema recovery rates after precipitation cooling

From a one dimensional view of temperature alone variations at the Earth's surface manifest themselves in two cyclic patterns of diurnal and annual periods, due principally to the effects of diurnal and seasonal changes in solar heating as well as gains and losses of available moisture. Beside these two well known cyclic patterns, a third cycle has been identified which occurs in values of diurnal maxima and minima soil temperature extrema at 10 cm depth usually over a mesoscale period of roughly 3 to 14 days. This mesoscale period cycle starts with precipitation cooling of soil and is followed by a power curve temperature recovery. The temperature recovery clearly depends on solar heating of the soil with an increased soil moisture content from precipitation combined with evaporation cooling at soil temperatures lowered by precipitation cooling, but is quite regular and universal for vastly different geographical locations, and soil types and structures. The regularity of the power curve recovery allows a predictive model approach over the recovery period. Multivariable linear regression models alloy predictions of both the power of the temperature recovery curve as well as the total temperature recovery amplitude of the mesoscale temperature recovery, from data available one day after the temperature recovery begins.

Welker, J. E.↗

Potential Impact of Land Use Change on Future Regional Climate in the Southeastern U.S.: Reforestation and Crop Land Conversion

The impact of future land use and land cover changes (LULCC) on regional and global climate is one of the most challenging aspects of understanding anthropogenic climate change. We study the impacts of LULCC on regional climate in the southeastern U.S. by downscaling the NASA Goddard Institute for Space Studies global climate model E to the regional scale using a spectral nudging technique with the Weather Research and Forecasting Model. Climate-relevant meteorological fields are compared for two southeastern U.S. LULCC scenarios to the current land use/cover for four seasons of the year 2050. In this work it is shown that reforestation of cropland in the southeastern U.S. tends to warm surface air by up to 0.5 K, while replacing forested land with cropland tends to cool the surface air by 0.5 K. Processes leading to this response are investigated and sensitivity analyses conducted. The sensitivity analysis shows that results are most sensitive to changes in albedo and the stomatal resistance. Evaporative cooling of croplands also plays an important role in regional climate. Implications of LULCC on air quality are discussed. Summertime warming associated with reforestation of croplands could increase the production of some secondary pollutants, while a higher boundary layer will decrease pollutant concentrations; wintertime warming may decrease emissions from biomass burning from wood stoves

Regional climate change↗

Heat transfer from a row of impinging jets to concave cylindrical surfaces

Starting from the first principles, and with one experimentally obtained parameter, an expression for stagnation heat transfer is derived, applicable to round, impinging jets. The results obtained with a row of air jets impinging on an electrically-heated surface in a small-scale setup characteristic of a typical turbine blade have been found compatible with the average heat transfer from a geometrically similar, steam-heated surface scaled up ten times, and comparable with the results of other investigators. These findings were linked to the flow fields likely to exist in the gas turbine blades, internally cooled by a row of round jets or a single jet of equivalent width. The magnitude of heat-transfer coefficients obtained here with impinging jets approaches that normally associated with forced convection of water and evaporative cooling.

Hrycak, P.↗

Evaporation of ice in planetary atmospheres - Ice-covered rivers on Mars

The existence of ice covered rivers on Mars is considered. It is noted that the evaporation rate of water ice on the surface of a planet with an atmosphere involves an equilibrium between solar heating and radiative and evaporative cooling of the ice layer. It is determined that even with a mean Martian insolation rate above the ice of approximately 10 to the -8th g per sq cm/sec, a flowing channel of liquid water will be covered by ice which evaporates sufficiently slowly that the water below can flow for hundreds of kilometers even with modest discharges. Evaporation rates are calculated for a range of frictional velocities, atmospheric pressures, and insolations and it is suggested that some subset of observed Martian channels may have formed as ice-choked rivers. Finally, the exobiological implications of ice covered channels or lakes on Mars are discussed.

Wallace, D.↗

Roles of drizzle in a one-dimensional third-order turbulence closure model of the nocturnal stratus-topped marine boundary layer

This study focuses on the effects of drizzle in a one-dimensional third-order turbulence closure model of the nocturnal stratus-topped marine boundary layer. When the simulated drizzle rate is relatively small (maximum approximately equal to 0.6 mm/day), steady-state solutions are obtained. The boundary layer stabilizes essentially because drizzle causes evaporative cooling of the subcloud layer. This stabilization considerably reduces the buoyancy flux and turbulence kinetic energy below the stratus cloud. Thus, drizzle tends to decouple the cloud from the subcloud layer in the model, as suggested by many observational studies. In addition, the evaporation of drizzle in the subcloud layer creates small scattered clouds, which are likely to represent cumulus clouds, below the solid stratus cloud in the model. The sensitivity experiments show that these scattered clouds help maintain a coupled boundary layer. When the drizzle rate is relatively large (maximum approximately equal to 0.9 mm/day), the response of the model becomes transient with bursts in turbulent fluxes. This phenomenon is related to the formation of the scattered cloud layer below the solid stratus cloud. It appears that the model is inadequate to represent the heat and moisture transport by strong updrafts covering a small fractional area in cumulus convection.

Wang, Shouping↗

Water Quality Contamination Sources and Controls for the Exploration Extra-vehicular Mobility Unit (xEMU)

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. The xEMU uses controlled evaporative cooling through a membrane to reject waste heat from the crewmember, avionics, and environmental in-leak during autonomous operation. Given the unique mass and volume constraints imposed by the spacesuit application and the opportunities presented by the selection of a given membrane, the xEMU does not possess a separate feedwater loop to feed the evaporation process, rather the feedwater for the evaporation process is fed directly from the transport loop which collects heat from the sources within the suit. This has many benefits including mass/volume reductions from a lower component count within the system but does pose some additional potential constraints on water quality within the system in order to provide a working fluid that can be pumped, filtered, and used in contact with the remainder of the system while both avoiding fouling of the membrane as well as other deleterious effects such as creating conditions for corrosion of wetted surfaces within the transport loop. The discussion will seek to address the main sources of contamination and the applied controls. Sources considered will include: self-generated via materials selection and processes applied, influent working fluid, contamination of the influent working fluid via Ground Support Equipment (GSE) or processing equipment, microbial activity, and environmental influences such as elevated ambient CO2.

Colin Campbell↗

Modeling Commercial Turbofan Engine Icing Risk With Ice Crystal Ingestion

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that have been attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was degraded engine performance, and one or more of the following: loss of thrust control (roll back), compressor surge or stall, and flameout of the combustor. As ice crystals are ingested into the fan and low pressure compression system, the increase in air temperature causes a portion of the ice crystals to melt. It is hypothesized that this allows the ice-water mixture to cover the metal surfaces of the compressor stationary components which leads to ice accretion through evaporative cooling. Ice accretion causes a blockage which subsequently results in the deterioration in performance of the compressor and engine. The focus of this research is to apply an engine icing computational tool to simulate the flow through a turbofan engine and assess the risk of ice accretion. The tool is comprised of an engine system thermodynamic cycle code, a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor flow path, without modeling the actual ice accretion. A commercial turbofan engine which has previously experienced icing events during operation in a high altitude ice crystal environment has been tested in the Propulsion Systems Laboratory (PSL) altitude test facility at NASA Glenn Research Center. The PSL has the capability to produce a continuous ice cloud which are ingested by the engine during operation over a range of altitude conditions. The PSL test results confirmed that there was ice accretion in the engine due to ice crystal ingestion, at the same simulated altitude operating conditions as experienced previously in flight. The computational tool was utilized to help guide a portion of the PSL testing, and was used to predict ice accretion could also occur at significantly lower altitudes. The predictions were qualitatively verified by subsequent testing of the engine in the PSL. The PSL test has helped to calibrate the engine icing computational tool to assess the risk of ice accretion. The results from the computer simulation identified prevalent trends in wet bulb temperature, ice particle melt ratio, and engine inlet temperature as a function of altitude for predicting engine icing risk due to ice crystal ingestion.

Jorgenson, Philip C. E.↗

Modeling of Commercial Turbofan Engine With Ice Crystal Ingestion: Follow-On

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that have been attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was degraded engine performance, and one or more of the following: loss of thrust control (roll back), compressor surge or stall, and flameout of the combustor. As ice crystals are ingested into the fan and low pressure compression system, the increase in air temperature causes a portion of the ice crystals to melt. It is hypothesized that this allows the ice-water mixture to cover the metal surfaces of the compressor stationary components which leads to ice accretion through evaporative cooling. Ice accretion causes a blockage which subsequently results in the deterioration in performance of the compressor and engine. The focus of this research is to apply an engine icing computational tool to simulate the flow through a turbofan engine and assess the risk of ice accretion. The tool is comprised of an engine system thermodynamic cycle code, a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor flow path, without modeling the actual ice accretion. A commercial turbofan engine which has previously experienced icing events during operation in a high altitude ice crystal environment has been tested in the Propulsion Systems Laboratory (PSL) altitude test facility at NASA Glenn Research Center. The PSL has the capability to produce a continuous ice cloud which is ingested by the engine during operation over a range of altitude conditions. The PSL test results confirmed that there was ice accretion in the engine due to ice crystal ingestion, at the same simulated altitude operating conditions as experienced previously in flight. The computational tool was utilized to help guide a portion of the PSL testing, and was used to predict ice accretion could also occur at significantly lower altitudes. The predictions were qualitatively verified by subsequent testing of the engine in the PSL. In a previous study, analysis of select PSL test data points helped to calibrate the engine icing computational tool to assess the risk of ice accretion. This current study is a continuation of that data analysis effort. The study focused on tracking the variations in wet bulb temperature and ice particle melt ratio through the engine core flow path. The results from this study have identified trends, while also identifying gaps in understanding as to how the local wet bulb temperature and melt ratio affects the risk of ice accretion and subsequent engine behavior.

Jorgenson, Philip C. E.↗

Modeling of Commercial Turbofan Engine with Ice Crystal Ingestion; Follow-On

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that have been attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was degraded engine performance, and one or more of the following: loss of thrust control (roll back), compressor surge or stall, and flameout of the combustor. As ice crystals are ingested into the fan and low pressure compression system, the increase in air temperature causes a portion of the ice crystals to melt. It is hypothesized that this allows the ice-water mixture to cover the metal surfaces of the compressor stationary components which leads to ice accretion through evaporative cooling. Ice accretion causes a blockage which subsequently results in the deterioration in performance of the compressor and engine. The focus of this research is to apply an engine icing computational tool to simulate the flow through a turbofan engine and assess the risk of ice accretion. The tool is comprised of an engine system thermodynamic cycle code, a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor flow path, without modeling the actual ice accretion. A commercial turbofan engine which has previously experienced icing events during operation in a high altitude ice crystal environment has been tested in the Propulsion Systems Laboratory (PSL) altitude test facility at NASA Glenn Research Center. The PSL has the capability to produce a continuous ice cloud which is ingested by the engine during operation over a range of altitude conditions. The PSL test results confirmed that there was ice accretion in the engine due to ice crystal ingestion, at the same simulated altitude operating conditions as experienced previously in flight. The computational tool was utilized to help guide a portion of the PSL testing, and was used to predict ice accretion could also occur at significantly lower altitudes. The predictions were qualitatively verified by subsequent testing of the engine in the PSL. In a previous study, analysis of select PSL test data points helped to calibrate the engine icing computational tool to assess the risk of ice accretion. This current study is a continuation of that data analysis effort. The study focused on tracking the variations in wet bulb temperature and ice particle melt ratio through the engine core flow path. The results from this study have identified trends, while also identifying gaps in understanding as to how the local wet bulb temperature and melt ratio affects the risk of ice accretion and subsequent engine behavior.

Jorgenson, Philip C. E.↗

Thrust Augmentation of a Turbojet Engine at Simulated Flight Conditions by Introduction of a Water-Alcohol Mixture into the Compressor

An investigation was conducted at simulated high-altitude flight conditions to evaluate the use of compressor evaporative cooling as a means of turbojet-engine thrust augmentation. Comparison of the performance of the engine with water-alcohol injection at the compressor inlet, at the sixth stage of the compressor, and at the sixth and ninth stages was made. From consideration of the thrust increases achieved, the interstage injection of the coolant was considered more desirable preferred over the combined sixth- and ninth-stage injection because of its relative simplicity. A maximum augmented net-thrust ratio of 1.106 and a maximum augmented jet-thrust ratio of 1.062 were obtained at an augmented liquid ratio of 2.98 and an engine-inlet temperature of 80 F. At lower inlet temperatures (-40 to 40 F), the maximum augmented net-thrust ratios ranged from 1.040 to 1.076 and the maximum augmented jet-thrust ratios ranged from 1.027 to 1.048, depending upon the inlet temperature. The relatively small increase in performance at the lower inlet-air temperatures can be partially attributed to the inadequate evaporation of the water-alcohol mixture, but the more significant limitation was believed to be caused by the negative influence of the liquid coolant on engine- component performance. In general, it is concluded that the effectiveness of the injection of a coolant into the compressor as a means of thrust augmentation is considerably influenced by the design characteristics of the components of the engine being used.

Useller, James W.↗

Development of advanced fuel cell system

Weight, life and performance characteristics optimization of hydrogen-oxygen fuel cell power systems were considered. A promising gold alloy cathode catalyst was identified and tested in a cell for 5,000 hours. The compatibility characteristics of candidate polymer structural materials were measured after exposure to electrolyte and water vapor for 8,000 hours. Lightweight cell designs were prepared and fabrication techniques to produce them were developed. Testing demonstrated that predicted performance was achieved. Lightweight components for passive product water removal and evaporative cooling of cells were demonstrated. Systems studies identified fuel cell powerplant concepts for meeting the requirements of advanced spacecraft.

Grevstad, P. E.↗

A numerical investigation of severe thunderstorm gust fronts

A numerical model was developed to simulate the evolution and structure of severe thunderstorm gust fronts. The model is a non-hydrostatic, fine resolution, cross-sectional primitive equation model. Two-dimensional horizontal and vertical equations of motion, the continuity equation, and the thermodynamic energy equation were utilized. It was shown that two dominant factors influencing gust front configuration are surface friction and the solenoidal field coincident with the front. It is suggested that solenoidal accelerations oppose the deceleration of surface friction. After a downdraft is initiated in the model, these opposing tendencies soon reach a balance and the gust front achieves a quasi-steady configuration. Thus, the experiments indicate that surface friction does not induce a cycle of front formation and collapse. In addition, the effect of evaporative cooling in producing a vigorous downdraft was parameterized by a local cooling function. Greater cooling in the downdraft results in a more intense gust front that exhibits stronger wind maximums and greater shears. The ambient air stability was shown to be an important factor influencing the depth of the cold outflow.

Mitchell, K. E.↗

The response of selected terrestrial organisms to the Martian environment - A modeling study

An energy balance model has been developed to investigate how the Martian atmospheric environment could influence a community of photosynthetic microorganisms with properties similar to those of a cyanophyte (blue-green algal mat) and a lichen. Surface moisture and soil nutrients are assumed to be available. The model was developed to approximate equatorial equinox conditions and includes parameters for solar and thermal radiation, convective and conductive energy transport, and evaporative cooling. Calculations include the diurnal variation of organism temperature and transpiration and photosynthetic rates. The influences of different wind speeds and organism size and resistivity are also studied. The temperature of organisms in mats less than a few millimeters thick will not differ from the ground temperature by more than 10 K. Water loss is actually retarded at higher wind speeds, since the organism temperature is lowered, thus reducing the saturation vapor pressure. Typical photosynthetic rates lead to the production of 1 millionth to 100 billionths mole O2 per sq cm/day.

Kuhn, W. R.↗

A fundamental study of liquid spray evaporation at a heated surface

The influence of feedwater temperature and the influence of pulsing nozzle flow on the heat transfer characteristics in the spray evaporative cooling process were investigated. A commercial water circulation heater was installed in the feedwater line between the supply reservoir and the nozzle. A pass through the heater provided water at temperatures up to 50 C at the nozzle; higher temperatures were obtained by multiple heater passes. A thermocouple installed in the water line just upstream of the nozzle provided a measure of the feedwater temperature. Initial tests were run with belljar exhaust orifice number two which provided a pressure in a range about 7mm Hg abs. The feedwater temperature was heated to a temperature of 45 C. Results indicate that for a given system operating pressure, there is an upper limit on the feedwater temperature above which the spray will flash to vapor before hitting the surface to be cooled.

Wierum, F. A.↗

A numerical study of a marine subtropical stratus cloud layer and its stability

A model for numerical simulation of stratus cloud layers is constructed by combining a second-order closure, turbulent transfer model with a thermal radiative transfer model. The turbulent transfer model allows water vapor saturation. The combined turbulence-radiation model is applied to both a horizontally uniform one-dimensional case and a horizontally nonuniform two-dimensional case. In the latter, the dynamics of mesoscale circulations are also incorporated. Results of the two-dimensional simulation show that the layer cloud instability occurs where the sea surface temperature is high and the large-scale subsidence is weak. The simulated instability is analyzed in view of an instability criterion, the eddy kinetic energy budget, and evaporative cooling near the cloud top.

Moeng, C.-H.↗

Automotive absorption air conditioner utilizing solar and motor waste heat

In combination with the ground vehicles powered by a waste heat generating electric motor, a cooling system including a generator for driving off refrigerant vapor from a strong refrigerant absorbant solution is described. A solar collector, an air-cooled condenser connected with the generator for converting the refrigerant vapor to its liquid state, an air cooled evaporator connected with the condenser for returning the liquid refrigerant to its vapor state, and an absorber is connected to the generator and to the evaporator for dissolving the refrigerant vapor in the weak refrigerant absorbant solution, for providing a strong refrigerant solution. A pump is used to establish a pressurized flow of strong refrigerant absorbant solution from the absorber through the electric motor, and to the collector.

Popinski, Z.↗

The feasibility of thermal inertia mapping for detection of perched water tables in semi-arid irrigated lands

The thermal inertia mapping remote sensing technique is evaluated as a potential method for delineating areas of shallow perched water tables and related salinization problems on a regional basis. This method for detecting shallow water tables is based on the existence of significant differences in soil thermal properties between wet and dry soil profiles. Ground observations were conducted at two different test sites in California along the flight line, with one site located in a perched water table area and the other site in a well drained area. Measurements were taken hourly during a four day period (two days before and two days after the flight) for variables such as radiometric, meteorologic, soil moisture and temperature profiles, and surface characteristics. Results indicate that it is not feasible using present apparent thermal inertia remote sensing techniques to reliably delineate regional patterns of very shallow water tables due to the complex environmental system. However, some features within specific fields which may be directly related to the local presence of shallow water tables, such as differences in evaporative cooling due to soil moisture effects between and within fields, can be detected using the thermal inertia technique.

Ezra, C. E.↗

Doppler-radar observation of the evolution of downdrafts in convective clouds

A detailed analysis of the 20 July 1977 thunderstorm complex which formed and evolve over the South Park region in Central Colorado is presented. The storm was extensively analyzed using multiple Doppler radar and surface mesonet data, developed within an environment having very weak wind shear. The storm owed its intensification to the strength of the downdraft, which was nearly coincident with the region where the cloud had grown. The noteworthy features of this storm were its motion to the right of the cloud-level winds, its multicellular nature and discrete propagation, its north-south orientation, and its relatively large storm size and high reflectivity factor (55 dBZ). This scenario accounts for the observed mesoscale and cloud-scale event. A line of convergence was generated at the interface between the easterly upslope winds and westerly winds. During stage II, the convergence line subsequently propagated down the slopes of the Mosquito Range, and was the main forcing mechanism for the development of updraft on the west flank of the storm. The formation of downdraft on the eastern side of updraft blacked surface inflow, and created a detectable gust front. As the original downdraft intensified, the accumulation of evaporatively-chilled air caused the intensification of the mesohigh, which likely destroyed the earlier convergence line and created a stronger convergence line to the east, which forced up-lifting of the moist, westerly inflow and caused the formation of updraft to the east. An organized downdraft circulation, apparently maintained by precipitation drag and evaporational cooling, was responsible in sustaining a well-defined gust front. The storm attained its highest intensity as a consequence of merging with a neighboring cloud. The interaction of downdrafts or gust fronts from two intense cells appeared to be the primary mechanism of this merging process as suggested by Simpson et al. (1980). The merging process coincided with more rain than occurred in unmerged echoes.

Motallebi, N.↗