Search NASA⌕ Search

SEARCH · Search NASA

Results for “expandable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Push-pull tests for estimating effective porosity: expanded analytical solution and in situ application

The analytical solution describing the one-dimensional displacement of the center of mass of a tracer during an injection, drift, and extraction test (push-pull test) was expanded to account for displacement during the injection phase. The solution was expanded to improve the in situ estimation of effective porosity. The truncated equation assumed displacement during the injection phase was negligible, which may theoretically lead to an underestimation of the true value of effective porosity. To experimentally compare the expanded and truncated equations, single-well push-pull tests were conducted across six test wells located in a shallow, unconfined aquifer comprised of unconsolidated and heterogeneous silty and clayey fill materials. The push-pull tests were conducted by injection of bromide tracer, followed by a non-pumping period, and subsequent extraction of groundwater. The values of effective porosity from the expanded equation (0.6–5.0%) were substantially greater than from the truncated equation (0.1–1.3%). The expanded and truncated equations were compared to data from previous push-pull studies in the literature and demonstrated that displacement during the injection phase may or may not be negligible, depending on the aquifer properties and the push-pull test parameters. The results presented here also demonstrated the spatial variability of effective porosity within a relatively small study site can be substantial, and the error-propagated uncertainty of effective porosity can be mitigated to a reasonable level (< ± 0.5%). The tests presented here are also the first that the authors are aware of that estimate, in situ, the effective porosity of fine-grained fill material.

58 GEOSCIENCES↗

Measuring chronic liver disease mortality using an expanded cause of death definition and medical records in C onnecticut, 2004

Aim Chronic liver disease ( CLD ) is a leading cause of death and is defined based on a specific set of underlying cause‐of‐death codes on death certificates. This conventional approach to measuring CLD mortality underestimates the true mortality burden because it does not consider certain CLD conditions like viral hepatitis and hepatocellular carcinoma. We measured how much the conventional CLD mortality case definition will underestimate CLD mortality and described the distribution of CLD etiologies in C onnecticut. Methods We used 2004 Connecticut death certificates to estimate CLD mortality two ways. One way used the conventional definition and the other used an expanded definition that included more conditions suggestive of CLD . We compared the number of deaths identified using this expanded definition with the number identified using the conventional definition. Medical records were reviewed to confirm CLD deaths. Results Connecticut had 29 314 registered deaths in 2004. Of these, 282 (1.0%) were CLD deaths identified by the conventional CLD definition while 616 (2.1%) were CLD deaths defined by the expanded definition. Medical record review confirmed that most deaths identified by the expanded definition were CLD ‐related (550/616); this suggested a 15.8 deaths/100 000 population mortality rate. Among deaths for which hepatitis B , hepatitis C and alcoholic liver disease were identified during medical record review, only 8.6%, 45.4% and 36.5%, respectively, had that specific cause‐of‐death code cited on the death certificate. Conclusion An expanded CLD mortality case definition that incorporates multiple causes of death and additional CLD ‐related conditions will better estimate CLD mortality.

Ly, Kathleen N.↗

Development of a High-Efficiency Hot Gas Turbo-expander and Low-Cost Heat Exchangers for Optimized CSP Supercritical CO 2 Operation

Southwest Research Institute® (SwRI®) has developed a novel, high-efficiency, supercritical carbon dioxide (sCO 2 ), hot gas turbo-expander optimized for the highly-transient, solar-powerplant, duty-cycle profile. This MW-scale sCO 2 turbo-expander design advances the state-of-theart of sCO 2 turbo-expanders from a current Technology Readiness Level (TRL) of three (initial, small-scale, laboratory, size testing) to a full TRL6 (MW-scale prototype demonstration). A secondary objective of this project was to optimize novel compact heat exchangers for sCO 2 applications to drastically reduce their manufacturing costs. Significant learning was achieved on how to design and fabricate a more cost effective, high performance recuperator, at the MWt capacity. The sCO 2 turbo-expander and novel sCO 2 heat exchanger have been tested in a 1- MWe sCO 2 test loop, fabricated to demonstrate component performance and the performance of the optimized sCO 2 Brayton cycle over a wide range of part load conditions and during transient operations representative of a typical Concentrating Solar Power (CSP) duty cycle. The scalable sCO 2 expander design and improved heat exchanger address and close two critical technology gaps required for an optimized CSP sCO 2 power plant and provide a major stepping stone on the pathway to achieving CSP power at $\$ $0.06/kW-hr Levelized Cost of Electricity (LCOE), increasing energy conversion efficiency to greater than 50% and reducing total power block cost to below $\$ $1,200/kW installed. Construction of the facility and testing has been completed. Test targets of 1,320°F, 27,000 rpm, and 3,500 psi were reached during separate tests. Overall, the turbine saw 37.5 hours of operation with many other hours of testing and troubleshooting all of the loop components. All the test data and troubleshooting is useful and applicable for future tests and operations with not only this loop but in any sCO2 application.

14 SOLAR ENERGY↗

The helical screw expander evaluation project

A positive-displacement helical-screw expander of the Lysholm type has been adapted for geothermal service and successfully demonstrated in a 50 kW prototype power system. Evaluation of the expander by tests of a new model in a 1 MW power system under wellhead conditions in selected liquid-dominated geothermal fields is proposed. The objectives are to determine the performance characteristics of the expander and power system over a broad range of operating conditions and also to examine the concept of wellhead power plants. Throttling and fractionation of the fluids from the test wells is planned to simulate a wide range of wellhead pressures and steam fractions. Variation in the expander exhaust pressure is also planned. The investigation will include expander efficiency, corrosion, erosion, scale formation and control, and endurance testing. Interaction studies with the wells and an electric grid are also proposed.

Mckay, R. A.↗

Expanded interleaved solid-state memory for a wide bandwidth transient waveform recorder

An interleaved, solid state expanded memory for a 100 MHz bandwidth waveform recorder is described. The memory development resulted in a significant increase in the storage capacity of a commercially available recorder. The motivation for the memory expansion of the waveform recorder, which is used to support in-flight measurement of the electromagnetic characteristics of lightning discharges, was the need for a significantly longer data window than that provided by the commercially available unit. The expanded recorder provides a data window that is 128 times longer than the commercial unit, while maintaining the same time resolution, by increasing the storage capacity from 1024 to 131 072 data samples. The expanded unit operates at sample periods as small as 10 ns. Sampling once every 10 ns, the commercial unit records for about 10 microseconds before the memory is filled, whereas, the expanded unit records for about 1300 microseconds. A photo of the expanded waveform recorder is shown.

Thomas, R. M., Jr.↗

Screw expander for light duty diesel engines

Preliminary selection and sizing of a positive displacement screw compressor-expander subsystem for a light-duty adiabatic diesel engine; development of a mathematical model to describe overall efficiencies for the screw compressor and expander; simulation of operation to establish overall efficiency for a range of design parameters and at given engine operating points; simulation to establish potential net power output at light-duty diesel operating points; analytical determination of mass moments of inertia for the rotors and inertia of the compressor-expander subsystem; and preparation of engineering layout drawings of the compressor and expander are discussed. As a result of this work, it was concluded that the screw compressor and expander designed for light-duty diesel engine applications are viable alternatives to turbo-compound systems, with acceptable efficiencies for both units, and only a moderate effect on the transient response.

Source record↗

International test and demonstration of a 1-MW wellhead generator: Helical screw expander power plant

A 1-MW wellhead generator was tested in 1980, 1981, and 1982 by Mexico, Italy, and New Zealand at Cerro Prieto, Cesano, and Broadlands, respectively. The total flow helical screw expander portable power plant, Model 76-1, had been built for the U.S. Government and field-tested in Utah, USA, in 1978 and 1979. The expander had oversized internal clearances designed for self-cleaning operation on fluids that deposit adherent scale normally detrimental to the utiliation of liquid dominated fields. Conditions with which the expander was tested included inlet pressures of 64 to 220 psia, inlet qualities of 0% to 100%, exhaust pressures of 3.1 to 40 psia, electrial loads of idle and 110 to 933 kW, electrical frequencies of 50 and 60 Hz, male rotor speeds of 2500 to 4000 rpm, and fluid characteristics to 310,000 ppm total dissolved solids and noncondensables to 38 wt % of the vapor. Some testing was done on-grid. Typical expander isentropic efficiency was 40% to 50% with the clearances not closed, and 5 percentage points or more higher with the clearances partly closed. The expander efficiency increased approximately logarithmically with shaft power for most operations, while inlet quality, speed, and pressure ratio across the machine had only small effects. These findings are all in agreement with the Utah test results.

Mckay, R. A.↗

Intelligent Flexible Materials for Space Structures: Expandable Habitat Engineering Development Unit

Expandable habitable elements are an enabling technology for human exploration in space and on planetary surfaces. Large geometries can be deployed from a small launch volume, allowing greater mission capability while reducing mass and improving robustness over traditional rigid shells. This report describes research performed by ILC Dover under the Intelligent Flexible Materials for Space Structures program on the design and manufacture of softgoods for LaRC's Expandable Habitat Engineering Development Unit (EDU). The EDU is a full-scale structural test article of an expandable hybrid habitat, integrating an expandable softgoods center section with two rigid end caps. The design of the bladder, restraint layer and a mock-up Thermal Micrometeoroid Cover is detailed together with the design of the interface hardware used to attach them to the end caps. The integration and design of two windows and a floor are also covered. Analysis was performed to study the effects of the open weave design, and to determine the correct webbing and fabric configuration. Stress analyses were also carried out on the interfaces between the softgoods and the end caps and windows. Testing experimentally determined the strength of the fabric and straps, and component testing was used to proof several critical parts of the design. This program established new manufacturing and design techniques that can be applied to future applications in expandable structures.

Hinkle, Jon↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

59 BASIC BIOLOGICAL SCIENCES↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

Wilson, Thomas S.↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

Wilson, Thomas S.↗

Compressed Expanded Natural Graphite (CENG) Processing for PCM Composites

The use of phase change materials (PCMs) in thermal energy storage applications has received considerable attention in recent decades. Organic PCMs are popular due to their high latent heat of fusion, noncorrosive properties, and relative stability over many charge and discharge cycles. A primary limitation of these materials is their low thermal conductivity. This has led researchers to develop various methods to increase thermal conductivity by seeding PCM with or impregnating them into more conductive materials. One method is to impregnate PCMs into compressed expanded natural graphite (CENG) matrices, which can improve thermal conductivity by a factor of 100. CENG matrices have received particular interest due to their low cost, high porosity, small (nano/micro) pore size, high pore density, high thermal conductivity, and ability to be compressed into many geometries. PCM/CENG matrix composites have been extensively studied; however, the effect that CENG processing has on PCM saturation and the overall matrix thermal conductivity has not been well investigated. This processing includes four major steps including graphite intercalation, thermal shock, compression, and PCM saturation. Intercalation involves soaking graphite flakes in sulfuric and/or nitric acid to intercalate the acids between the graphene layers. The graphite flakes are then subjected to a high-temperature thermal shock, during which the intercalated acid is gasified rapidly, pushing the graphene layers apart, resulting in accordion-shaped graphite "worms". The "worms" are then compacted to a desired bulk density and then soaked with molten PCM until fully saturated. The properties of the produced CENG matrix, and its ability to allow PCM permeation, are sensitive to the processing parameters, namely, the thermal shock temperature and exposure time, as well as the matrix apparent density or porosity. Here, we study the effect of the thermal shock conditions necessary to expand intercalated graphite flakes on PCM saturation and the expanded graphite's thermal conductivity and morphology. We found that the thermal shock temperature exhibits the greatest influence. At greater shock temperatures, SEM images showed that expanded graphite worms exhibited greater density of pores, thus increasing total surface area within the matrices. Increasing thermal shock temperature yielded greater overall PCM saturation, as well as an increased rate of saturation. Improvements in PCM saturation rate and overall saturation are obtained as the shock temperature is increased. Longer exposure to thermal shock also improves initial saturation rates and is beneficial if a shortened impregnation time is needed. Thermal shock conditions did not impact thermal conductivity; however, conductivity was largely affected by matrix porosity. A local maximum in axial thermal conductivity was observed at around 83% porosity, which is similar to that observed in previous studies.

compressed expanded natural graphite↗

Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5-6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into 'normal-sized' (stent-to-artery-ratio < 1.4, n = 12) and 'oversized' (stent-to-artery-ratio {>=} 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mastectomy With Immediate Expander-Implant Reconstruction, Adjuvant Chemotherapy, and Radiation for Stage II-III Breast Cancer: Treatment Intervals and Clinical Outcomes

Purpose: To determine intervals between surgery and adjuvant chemotherapy and radiation in patients treated with mastectomy with immediate expander-implant reconstruction, and to evaluate locoregional and distant control and overall survival in these patients. Methods and Materials: Between May 1996 and March 2004, 104 patients with Stage II-III breast cancer were routinely treated at our institution under the following algorithm: (1) definitive mastectomy with axillary lymph node dissection and immediate tissue expander placement, (2) tissue expansion during chemotherapy, (3) exchange of tissue expander for permanent implant, (4) radiation. Patient, disease, and treatment characteristics and clinical outcomes were retrospectively evaluated. Results: Median age was 45 years. Twenty-six percent of patients were Stage II and 74% Stage III. All received adjuvant chemotherapy. Estrogen receptor staining was positive in 77%, and 78% received hormone therapy. Radiation was delivered to the chest wall with daily 0.5-cm bolus and to the supraclavicular fossa. Median dose was 5040 cGy. Median interval from surgery to chemotherapy was 5 weeks, from completion of chemotherapy to exchange 4 weeks, and from exchange to radiation 4 weeks. Median interval from completion of chemotherapy to start of radiation was 8 weeks. Median follow-up was 64 months from date of mastectomy. The 5-year rate for locoregional disease control was 100%, for distant metastasis-free survival 90%, and for overall survival 96%. Conclusions: Mastectomy with immediate expander-implant reconstruction, adjuvant chemotherapy, and radiation results in a median interval of 8 weeks from completion of chemotherapy to initiation of radiation and seems to be associated with acceptable 5-year locoregional control, distant metastasis-free survival, and overall survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamically Chiral Expanded Helicenes

Expanded helicenes are a class of chiral nanographenes with a screw-shaped skeleton and a larger diameter than their classical ortho-fused counterparts. The flexibility of this internal cavity results in helicenes that are often difficult to isolate as single enantiomers. Expanded helicenes are therefore an intriguing target for exploration of dynamic chirality, a phenomenon resulting from introduction of chiral auxiliaries to control structure in a racemic system. This contribution describes installation of chiral amine substituents into the cavity of a diformyl expanded [11]-helicene by mild, efficient, and reversible imine condensations. The resulting helicenes display strong molar circular dichroism up to |Δε| = 300 M -1 cm -1 and absorption dissymmetry factors of |g abs | = 0.010. The magnitude of circular dichroism can be varied by using different chiral amine substituents, which is correlated to the diastereomeric ratios of the helicenes. In conclusion, this is the first instance of dynamic chirality being used to observe a chiroptic response in expanded helicenes and is a significant synthetic improvement over methods which require conventional enantiomer resolution.

Rothenberger, August J. [University of California,↗

Unlocking expanded flagellin perception through rational receptor engineering

Abstract The surface-localized receptor kinase FLS2 detects the flg22 epitope from bacterial flagella. FLS2 is conserved across land plants, but bacterial pathogens exhibit polymorphic flg22 epitopes. Most FLS2 homologues possess narrow perception ranges, but four with expanded perception have been identified. Using diversity analyses, AlphaFold modelling and amino acid properties, key residues enabling expanded recognition were mapped to FLS2’s concave surface, interacting with the co-receptor and polymorphic flg22 residues. Synthetic biology enabled engineering of expanded recognition from QvFLS2 (Quercus variabilis) into a homologue with canonical perception. A similar approach enabled transfer ofAgrobacteriumperception from FLS2 XL (Vitis riparia) into VrFLS2. Evolutionary analyses across three plant orders showed residues under positive selection aligning with those binding the co-receptor and flg22’s C terminus, suggesting more alleles with expanded perception exist. Our experimental data enabled the identification of specific receptor amino acid properties and AlphaFold3 metrics that facilitate predicting FLS2–flg22 recognition. This study provides a framework for rational receptor engineering to enhance pathogen restriction.

Plant Sciences↗

Waves in expanding electronegative plasmas containing double layers

Expanding electronegative (EN) plasmas have been previously observed, experimentally, to generate wave activity. Using a particle-in-cell (PIC) code we have investigated these waves in expanding EN plasmas containing a double layer (DL) between an upstream source region and an expanded downstream region. Oxygen reaction rates were used but modified to correspond more closely to experimental conditions. Under a subset of pressures, for which a DL existed, waves were observed traveling upstream in the expanded region, and growing in amplitude in the direction of travel. Both slow and fast waves were observed. The fast wave existed only over part of the slow wave pressure range. The PIC results were compared to both fluid and kinetic theory, both of which assumed axial uniformity. The results of a somewhat simplified fluid theory, ignoring fast wave coupling and collisions with the background gas, gave a remarkable result: if the theory predicted a slow wave instability for any axial parameters in the downstream region, the instability was observed in the simulation. Conversely, if no instability was predicted at any axial position, no instability was observed. More accurate kinetic calculations, including electron and ion Landau damping, and also collisional damping against the background gas, gave wavelengths and growth rates that were consistent with the PIC simulations, and with the fluid results. The kinetic theory also indicated that the fast waves were always stable but became weakly damped for conditions of unstable slow waves. We postulate that nonlinear and nonuniformity effects excite the fast waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nitrogen expander cycles for large capacity liquefaction of natural gas

Thermodynamic study is performed on nitrogen expander cycles for large capacity liquefaction of natural gas. In order to substantially increase the capacity, a Brayton refrigeration cycle with nitrogen expander was recently added to the cold end of the reputable propane pre-cooled mixed-refrigerant (C3-MR) process. Similar modifications with a nitrogen expander cycle are extensively investigated on a variety of cycle configurations. The existing and modified cycles are simulated with commercial process software (Aspen HYSYS) based on selected specifications. The results are compared in terms of thermodynamic efficiency, liquefaction capacity, and estimated size of heat exchangers. The combination of C3-MR with partial regeneration and pre-cooling of nitrogen expander cycle is recommended to have a great potential for high efficiency and large capacity.

42 ENGINEERING↗