Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Light charged ion measurements and Monte Carlo calculations from thick targets bombarded by protons and heavy ions - 25435

The data presented in this work are from experiments performed in November 2016 and November 2017 at the National Aeronautics and Space Administration (NASA) Space Radiation Laboratory at Brookhaven National Laboratory (BNL). The secondary light charged ions (Z=1 and 2 ions) and neutrons produced by 400-, 800-, and 2500-AMeV protons and 400-, 800-, and 1500-AMeV He, C, Si, Fe ions bombarding thick targets (20, 40, and 60 g/cm{sup 2} aluminum and high-density polyethylene (HDPE), and 20 and 60 g/cm{sup 2} combination of aluminum and HDPE) were measured with organic liquid scintillators and sodium iodide (NaI) detectors. The organic liquid scintillators were positioned at 10 deg., 30 deg., 45 deg., 60 deg., 80 deg., and 135 deg. with respect to the beam direction, while NaI detectors were placed at 10 deg. and 30 deg. off the beam axis. The double-differential thick-target secondary light charged ion yields measured by organic liquid scintillators are of main interest here. In the analysis, after applying pulse shape discrimination to separate protons, deuterons, tritons, helium-3, and helium-4 particles, the time of flight technique was used to produce the secondary charged particle angular-energy spectra. Additionally, the spectra were compared with simulation results using the Monte Carlo simulation code, PHITS version 2.88. To obtain favorable statistics in PHITS calculations, ring-type detectors were modeled, which have the same distances and equivalent angles with the experimental setup. These experimental data will be integrated into the uncertainty analysis for NASA to optimize future GCR shielding design. (authors)

43 PARTICLE ACCELERATORS↗

Passive heat removal in horizontally oriented micro-HTGRs

There are novel, horizontally oriented high-temperature gas-cooled micro-reactor (HTGR) designs under consideration because of their portability, simplicity, and reliable operation. These features of the micro-HTGR design can meet the fission battery attributes, such as economic, standardize, installed, unattended and reliable. Although there have been HTGR related safety studies, micro-HTGRs when horizontally oriented are expected to exhibit significantly different thermal physics. During the unavailability of helium circulation, the internal reactor core is designed to cool by block-to-block conduction and radiation, and the reactor vessel surface is cooled by the ambient air. This scenario is anticipated during the transport of the micro-HTGR in a shipping container. The conduction and radiation between the prismatic micro-HTGR blocks in the core can be influenced by variances in the thermal contacts. This work investigated the conduction within a simulated horizontal HTGR core. An experimental setup was used to validate a numerical model. The experimental setup consisted of a hexagonal assembly with scaled prismatic blocks placed within a high-temperature vacuum environment. The gaps between the blocks were well controlled and monitored. The experimental setup was designed in such a way that the temperature variation in the axial direction was minimal, such that the experiment could be observed as a 2D (r, ) heat transfer problem. The pressurized tube was equipped with Infra-Red (IR) transparent windows, and an IR camera was used to capture the spatio-temporal temperature evolution in the hexagonal block assembly during the cooldown experiments. The experimental scenario was computationally modeled with a finite element analysis (FEA) program. Once validated, the computational model was used to investigate the impact of gap conductance on overall decay heat removal. Using a conservative estimate for gap conductance value (100 W/m 2 -K) between the prismatic blocks, there is a negligible increase in temperature observed during decay heat generation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance of the Versatile Array of Neutron Detectors at Low Energy (VANDLE)

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new, highly efficient plastic-scintillator array constructed for decay and transfer reaction experimental setups that require neutron detection. The versatile and modular design allows for customizable experimental setups including beta-delayed neutron spectroscopy and (d,n) transfer reactions in normal and inverse kinematics. The neutron energy and prompt-photon discrimination is determined through the time of flight technique. Fully digital data acquisition electronics and integrated triggering logic enables some VANDLE modules to achieve an intrinsic efficiency over 70% for 300-keV neutrons, measured through two different methods. A custom Geant4 simulation models aspects of the detector array and the experimental setups to determine efficiency and detector response. Lastly, a low detection threshold, due to the trigger logic and digitizing data acquisition, allowed us to measure the light-yield response curve from elastically scattered carbon nuclei inside the scintillating plastic from incident neutrons with kinetic energies below 2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Radar Imaging Technique Using a 2 Mev Linear Electron Accelerator

X-ray radar imaging, patented in 2013 by James R. Wood, combines standard radar techniques with the penetration power of x-rays to image scenes. Our project strives to demonstrate the technique using a 2 MeV linear electron accelerator (linac) to generate the S-band–modulated x-ray signals. X-ray detectors such as photodiodes and scintillators are used to detect the signals in backscatter and transmission detection schemes. The S-band microstructure is imposed on the variable-width electron pulse, and this modulation carries over to the bremsstrahlung x-rays after the electron beam is incident upon a copper-tungsten alloy target. Using phase/distance calculations and a low-jitter timing system, we expect to detect different object distances by comparing the measured phase differences. The experimental setup, which meets strict jitter requirements, and preliminary experimental results are presented.

43 PARTICLE ACCELERATORS↗

WE-H-BRA-05: Investigation of LET Spectral Dependence of the Biological Effects of Therapeutic Protons

Purpose: To investigate the dependence of biologic effect (BE) of therapeutic protons on LET spectra by comparing BEs with equal dose-averaged LET (LETd) derived from different LET spectra using high-throughput in vitro clonogenic survival assays. Methods: We used Geant4 to design the relevant experimental setups and perform the dose, LETd, and LET spectra calculations for spot-scanning protons. The clonogenic assay was performed using the H460 lung cancer cell line cultured in 96-well plates. In the first experimental setup (S1), cells were irradiated using 127.4 MeV protons with a 93.22 mm Lucite buildup resulting in a LETd value of 3.4 keV/µm in the cell layer. In the second experimental setup (S2), cells were irradiated by a combination of 127.4 MeV and 136.4 MeV protons with a 96.61 mm Lucite buildup. The LETd values in the cell layer were 11.4 keV/µm and 1.5 keV/µm respectively, but an average LETd of 3.4 keV/µm was obtained by adjusting the relative fluence of each beam. Ten discrete dose levels with 0.5 Gy increments were delivered. Results: In the two setups, the energies or LET spectra were different but resulted in identical LETd values. We quantified the dose contributions from high-LET (≥10 keV/µm, threshold determined by previous experiments) events in the LET spectra separately for these two setups as 3.2% and 10.5%. The biologic effects at each identical dose level yielded statistically significant different survival curves (extra sum-of-squares F-test, P<0.0001). The second setup with a higher contribution from high-LET events exhibited the higher biologic effect with a dose enhancement factor of 1.17±0.03 at 0.10 surviving fraction. Conclusion: The dose-averaged LET may not be an accurate indicator of the biological effects of protons. Detailed LET spectra may need to be considered explicitly to accurately quantify the biologic effects of protons. Funding Support: U19 CA021239-35, R21 CA187484-01 and MDACC-IRG.

60 APPLIED LIFE SCIENCES↗

Hypernuclear spectroscopy with electron beam at JLab Hall C

Hypernuclear spectroscopy with electron beam at JLab Hall C has been studied since 2000. The first experiment, JLab E89-009, used Short Orbit Spectrometer (SOS) as a kaon arm and a split-pole type spectrometer (ENGE) as an electron arm. E89-009 employed zero-degree tagging method, which tags scattered electrons at zero-degree and the kaon arm also covered zero-degree. This method obtains maximum yield of hypernuclei but sufferers from high rate background of electrons from bremsstrahlung and positrons from pair-creation. Nevertheless, this experiment demonstrated the possibility of the (e,e' K{sup +}) reaction for hypernuclear spectroscopy by obtaining a hypernuclear mass spectrum with an energy resolution of better than 1 MeV (FWHM) [1][2]. However, poor signal to noise ratio and poor statistics requires us to improve the experimental setup. Therefore, E01-011 experiment was proposed based on the success of the JLab E01-011 experiment. Improvements of E01-011 from E09-009 can be summarized as: 1. Employed newly constructed high resolution kaon spectrometer (HKS) as a kaon arm. 2. Employed so-called 'tilt-method' for the electron arm. With the newly constructed HKS, having 2-10-4 momentum resolution, we expect an energy resolution of 400 keV (FWHM). The 'tilt-method' means the electron arm is tilted vertically to the splitter dispersive plane to avoid background electrons from bremsstrahlung and moeller scattering. The setup allowed us to use up to a few tens beam. The experiment was performed in 2005 and final result will be shown shortly. The third experiment, JLab E05-115 experiment was proposed as a natural extension of E01-011 experiment and will be performed in 2009. Improvements of experimental setup are, 1. Employed newly constructed high resolution electron spectrometer (HES) as a electron arm, 2. Employed a new charge-separation magnet (Splitter), fully customized for hypernuclear experiment at Hall C. With the third generation experimental setup, we can study variety of targets up to medium-heavy ones such as {sup 52}Cr. This talk mainly focuses on the current status of the E05-115 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of high-precision Λ hypernuclear spectroscopy via the (e,e&#x27;K + ) reaction

The study of Λ hypernuclear structure is very interesting in point of the understanding of the interaction between Λ and nucleon (Λ-N interaction) and its strange structure itself due to the containment of a Λ hyperon which has a strangeness as a new degree of freedom. In the several way to study the Lamda hypernuclei, the (e,e&#x27;K + ) reaction spectroscopy is a powerful tool for the precise investigation of Λ hypernuclear structure. The purpose of the preset thesis is the establishment of the experimental design with the efficient data analysis method for the (e,e&#x27;K + ) hypernuclear spectroscopic experiment in the wide mass region (from A=7 to A=52). It is very challenging to perform the (e,e&#x27;K + ) spectroscopic experiment with such a heavy target, because of the huge electron background due to the bremsstrahlung process. In the experiment, it is required to obtain the necessary hypernuclear yield, suppressing the background event ratio. We achieved these requirements by newly constructing the high resolution electron spectrometer (HES) and splitter magnet (SPL) dedicated to the (e,e&#x27;K + ) spectroscopic experiment. The HES consists of two quadrupole magnets and a dipole magnets (Q-Q-D) with a momentum resolution of dp/p = 3x10 -4 at p = 0.84 GeV/c. It was used being vertically tilted by 6.5 degree so as to optimize signal to noise ratio and hypernuclear yield. The SPL is a dipole magnet. The experimental target was placed at the entrance of this magnet. The role of the SPL is to separate four kind of particles; scattered kaons, photons created by the bremsstrahlung, the post beam and scattered electrons. In addition, since the SPL is a part of the kaon and electron spectrometers. We designed the magnet shape carefully considering these points. The experiment was performed with 2.344 GeV/c electron beam from CEBAF at Jefferson Lab. The experimental setup consists of the HES, SPL and HKS (high momentum resolution kaon spectrometer). The HKS is also a Q-Q-D type spectrometer with the momentum resolution of dp/p = 2x10 -4 at p = 1.2 GeV/c. In the data analysis, the particle momentum calibration was the most important procedure. At the initial point, the particle momentum was obtained from the calculated magnetic field map of the spectrometer whose accuracy is an order of 10 -2 . The initial momentum was calibrated by two step, the the magnetic field map improvement and the calibration with known masses of Λ/σ 0 which were observed by the CH 2 target data. As a result of the calibration, the momentum resolutions of HKS and HES were estimated as 4x10 -4 and 6x10 -4 , respectively. Though these values are the double of the designed value, it was achieved to obtain the Λ/σ 0 peaks with the same order of the designed energy from the original calculated magnetic field. The cross section was calculated with the several estimated factors. The averaged p(γ*, K + )Λ cross section in the HKS acceptance, (0.90 < cos(θ^CM_K + ) < 1.0) was calculated as 227 ± 12 ±26 [nb/sr], which is consistent within the error bar with the other experiment results of p(γ, K + )Λ. The obtained yield of the peak was almost same as the designed value with the considered detector efficiencies. The observed hypernuclear spectrum of 12 Λ B was also consistent with the other experimental results. These analysis result represents that the experimental setup including the newly constructed HES and SPL worked and the calibration procedure of this unique experimental setup is basically established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High efficiency beta-decay spectroscopy using a planar germanium double-sided strip detector

Beta-decay spectroscopy experiments are limited by the detection efficiency of ions and electrons in the experimental setup. While there is a variety of different experimental setups in use for beta-decay spectroscopy, one popular choice is silicon double-sided strip detectors (DSSD). The higher Z of Ge and greater availability of thicker detectors as compared to Si potentially offer dramatic increases in the detection efficiency for beta-decay electrons. In this work, a planar GeDSSD has been commissioned for use in beta-decay spectroscopy experiments at the National Superconducting Cyclotron Laboratory (NSCL). The implantation response of the detector and its beta-decay detection efficiency is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Spouted Bed Reactor for Chemical Looping Combustion

We have investigated a novel gas/solid contacting configuration for chemical looping combustion (CLC) with potential operating benefits. CLC configurations are typically able to achieve high fuel conversion efficiencies at the expense of high operating costs and low system reliability. The spouted fluid bed (SB) was identified as an improved reactor configuration for CLC, since it typically exhibits high heat transfer rates and offers the ability to use lower gas flows for material movement compared to bubbling beds (BB). Multiphase Flow with Interphase eXchanges (MFIX) software was used to establish a spouted fluid bed reactor design. An experimental setup was built to supplement the model. The experimental setup was also modified for testing under high temperature, reacting conditions (1073–1273 K). The setup was operated in either a spouted fluid bed or a bubbling bed regime to compare the performance attributes of each. Results for the reactor configurations are presented for CLC using a mixture of carbon monoxide and hydrogen as fuel. Compared to the bubbling bed, the spouted fluid bed reactor achieved an equivalent or better fuel conversion at a lower pressure drop over the material bed. The spouted fluid bed design represents a viable configuration to improve gas/solid contacting for efficient fuel conversion, lower energy requirements for material movement and increase operational robustness for CLC. The research laid the groundwork for future research into a multi-phase reacting flow CLC system. The system will be developed from computational fluid dynamic modeling and pilot-scale testing to expedite the development of CLC technologies.

Energy & Fuels↗

Study of Influence of Electrode Geometry on Impedance Spectroscopy

Electrochemical Impedance Spectroscopy (EIS) is a powerful and proven tool for analyzing AC impedance response. A conventional three electrode EIS method was used to perform the investigation in the present study. Saturated potassium chloride solution was used as the electrolyte and three different material rods were used as working electrodes. Different configurations of electrode area were exposed to the electrolyte as an active area to investigate electrode geometry effects. Counter to working electrode distance was also altered while keeping the working electrode effective area constant to explore the AC response dependence on the variation of ion travel distance. Some controlled experiments were done to validate the experimental setup and to provide a control condition for comparison with experimental results. A frequency range of 100 mHz to 1 MHz was used for all experiments. In our analysis, we have found a noteworthy influence of electrode geometry on AC impedance response. For all electrodes, impedance decreases with the increase of effective area of the electrolyte. High frequency impedance is not as dependent on geometry as low frequency response. The observed phase shift angle drops in the high frequency region with increased working electrode area, whereas at low frequency the reverse is true. Resistance and capacitive reactance both decrease with an increase of area, but resistance response is more pronounce than reactance. For lower frequencies, small changes in working area produce very distinctive EIS variations. Electrode material as well as geometry was systematically varied in the present study. From these and other studies, we hope to develop a fundamental foundation for understanding specific changes in local geometry in fuel cell (and other) electrodes as a method of designing local morphology for specific performance.

30 DIRECT ENERGY CONVERSION↗

Charged pion form factor between Q{sup 2}=0.60 and 2.45 GeV{sup 2}. I. Measurements of the cross section for the {sup 1}H(e,e{sup '}{pi}{sup +})n reaction

Cross sections for the reaction {sup 1}H(e,e{sup '}{pi}{sup +})n were measured in Hall C at Thomas Jefferson National Accelerator Facility (JLab) using the high-intensity Continuous Electron Beam Accelerator Facility (CEBAF) to determine the charged pion form factor. Data were taken for central four-momentum transfers ranging from Q{sup 2}=0.60 to 2.45 GeV{sup 2} at an invariant mass of the virtual photon-nucleon system of W=1.95 and 2.22 GeV. The measured cross sections were separated into the four structure functions {sigma}{sub L},{sigma}{sub T},{sigma}{sub LT}, and {sigma}{sub TT}. The various parts of the experimental setup and the analysis steps are described in detail, including the calibrations and systematic studies, which were needed to obtain high-precision results. The different types of systematic uncertainties are also discussed. The results for the separated cross sections as a function of the Mandelstam variable t at the different values of Q{sup 2} are presented. Some global features of the data are discussed, and the data are compared with the results of some model calculations for the reaction {sup 1}H(e,e{sup '}{pi}{sup +})n.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental study of the A(e,e'{pi}{sup +}) reaction on {sup 1}H, {sup 2}H, {sup 12}C, {sup 27}Al, {sup 63}Cu and {sup 197}Au.

Cross sections for the {sup 1}H(e,e'{pi}{sup +})n process on {sup 1}H, {sup 2}H, {sup 12}C, {sup 27}Al, {sup 63}Cu, and {sup 197}Au targets were measured at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) to extract nuclear transparencies. Data were taken from Q{sup 2}=1.1-4.7 GeV{sup 2} for a fixed center-of-mass energy of W=2.14 GeV. The ratio of {sigma}{sub L} and {sigma}{sub T} was extracted from the measured cross sections for {sup 1}H, {sup 2}H, {sup 12}C, and {sup 63}Cu targets at Q{sup 2}=2.15 and 4.0 GeV{sup 2}, allowing for additional studies of the reaction mechanism. In this article, we present the experimental setup and the analysis of the data in detail, including systematic uncertainty studies. Differential cross sections and nuclear transparencies as a function of the pion momentum at different values of Q{sup 2} are presented. Our results are consistent with the predicted early onset of color transparency in mesons. Global features of the data are discussed and the data are compared with model calculations for the {sup 1}H(e,e'{pi}{sup +})n reaction from nuclear targets.

43 PARTICLE ACCELERATORS↗

Experimental scheme for unambiguous discrimination of linearly independent symmetric states

We propose an experimental setup for discriminating four linearly independent nonorthogonal symmetric quantum states. The setup is based on linear optics only and can be configured to implement both optimal unambiguous state discrimination [Chefles and Barnett, Phys. Lett. A 250, 223 (1998)] and minimum error discrimination. In both cases, the setup is characterized by an optimal success probability. The experimental setup can be generalized to the case of discrimination among N linearly nonorthogonal symmetric quantum states. We also study the discrimination between two incoherent superpositions of symmetric states. In this case, the setup also achieves an optimal success probability in the case of unambiguous discrimination as well as minimum error discrimination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Tropical Basin Interaction Model Intercomparison Project (TBIMIP)

Abstract. Large-scale interaction between the three tropical ocean basins is an area of intense research that is often conducted through experimentation with numerical models. A common problem is that modeling groups use different experimental setups, which makes it difficult to compare results and delineate the role of model biases from differences in experimental setups. To address this issue, an experimental protocol for examining interaction between the tropical basins is introduced. The Tropical Basin Interaction Model Intercomparison Project (TBIMIP) consists of experiments in which sea surface temperatures (SSTs) are prescribed to follow observed values in selected basins. There are two types of experiments. One type, called standard pacemaker, consists of simulations in which SSTs are restored to observations in selected basins during a historical simulation. The other type, called pacemaker hindcast, consists of seasonal hindcast simulations in which SSTs are restored to observations during 12-month forecast periods. TBIMIP is coordinated by the Climate and Ocean – Variability, Predictability, and Change (CLIVAR) Research Focus on Tropical Basin Interaction. The datasets from the model simulations will be made available to the community to facilitate and stimulate research on tropical basin interaction and its role in seasonal-to-decadal variability and climate change.

Richter, Ingo↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

Dense cold baryonic matter

A possibility of studying cold nuclear matter on the Nuclotron-NICA facility at baryonic densities characteristic of and higher than at the center of a neutron star is considered based on the data from cumulative processes. A special rare-event kinematic trigger for collisions of relativistic ions is proposed for effective selection of events accompanied by production of dense baryonic systems. Possible manifestations of new matter states under these unusual conditions and an experimental program for their study are discussed. Various experimental setups are proposed for these studies, and a possibility of using experimental setups at the Nuclotron-NICA facility for this purpose is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IR Laser Control of the Clustering of CF{sub 3}Br Molecules during the Gas-Dynamic Expansion of a CF{sub 3}Br/Ar Mixture: Bromine Isotope Selectivity

The infrared (IR) laser radiation control of the clustering of CF3Br molecules during the gas-dynamic expansion of a CF{sub 3}Br/Ar mixture at the exit from a nozzle is investigated. Prominence is given to studying the possibility of bromine-isotope-selective suppression of the clustering of CF{sub 3}Br molecules due to their resonance vibrational excitation in the gas-dynamic expansion zone near the nozzle. A continuous CO{sub 2} laser is used in experiments to excite molecules and clusters in a beam, and a quadrupole mass spectrometer is used to detect them. The experimental setup and the experimental technique are described. The dependences of the efficiency of molecule clustering suppression on the exciting laser radiation parameters, the gas parameters (composition, pressure) above the nozzle, and the distance from the nozzle exit section to a molecule irradiation zone are obtained. Bromine-isotope-selective suppression of molecule clustering is shown to occur at the exit from the nozzle due to the resonance vibrational excitation of gas-dynamically cooled CF{sub 3}Br molecules. When CF{sub 3}Br/Ar mixtures are used at pressure ratios p(CF{sub 3}Br): p(Ar) = 1: 10 and 1: 30, the enrichment of a cluster beam by bromine isotopes are K{sub enr}({sup 81}Br) ≈ 1.18 ± 0.09 and 1.12 ± 0.07 during the 9R(30) laser line (1084.635 cm{sup –1}) irradiation of a jet. The clustering suppression selectivity is α ≈ 1.18 when the mixture at the pressure ratio p(CF{sub 3}Br): p(Ar) = 1: 10 is used. These results suggest that the proposed method can selectively control the clustering of the molecules containing the heavy element isotopes that have a small isotope shift in IR absorption spectra (OsO{sub 4}, WF{sub 6}, UF{sub 6}).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of spray coated cathodes for RITS-6.

This report documents work conducted in FY13 to conduct a feasibility study on thermal spray coated cathodes to be used in the RITS-6 accelerator in an attempt to improve surface uniformity and repeatability. Currently, the cathodes are coated with colloidal silver by means of painting by hand. It is believed that improving the cathode coating process could simplify experimental setup and improve flash x-ray radiographic performance. This report documents the experimental setup and summarizes the results of our feasibility study. Lastly, it describes the path forward and potential challenges that must be overcome in order to improve the process for creating uniform and repeatable silver coatings for cathodes.

Simpson, Sean↗