At least 73 records · Page 4

Floating Wind Array Ontology and Modeling Framework

While there are many tools for designing and modeling a single floating turbine, array level design and modeling has much more to consider. Designing floating wind arrays requires a coupled approach considering many variables, from bathymetry to installation and maintenance to failure and risk analysis. With all of these considerations, an array-level modeling tool is needed to quickly evaluate array designs. The Floating Array Model (FAModel) tool developed at the National Renewable Energy Laboratory was created to fill this gap in low-fidelity array modeling. FAModel is a python framework created to streamline holistic low-fidelity floating wind modeling for array-level analysis. FAModel integrates site data and models with a variety of open-source modeling tools developed by NREL, including FLORIS, RAFT, MoorPy, and anchor capacity models. The integration of these tools allows users to quickly and holistically design an array by considering forces, area analysis, visualization, annual energy production, failure modeling, and component costs.

17 WIND ENERGY↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗

Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure

Swings in pH can be achieved by electrically polarizing a bipolar membrane (BPM) to drive water dissociation at the BPM junction for electrochemical conversion and separation processes. BPM junction design is critical to tailor performance for specific applications; however, characterization techniques capable of resolving the nanometer scale physical structure of the junction are limited. We present sample preparation, imaging, and analysis workflows that are adaptable to a variety of BPM junction architectures. Atomic force microscopy produces BPM junction images with nanometer scale lateral resolution for samples with and without a graphene oxide water dissociation catalyst in the junction. Subsequent image segmentation and analysis quantify line edge roughness and catalyst layer thickness as descriptors of junction structure. Comparison of pre- and post-electrodialysis junctions suggests electric field-induced alignment of catalyst particles during electrodialysis. This characterization workflow can inform manufacturing protocols, computational modeling, and failure mode analysis for next-generation BPMs.

97 MATHEMATICS AND COMPUTING↗

Impact of metal diffusion, lattice distortions, native defects, and ambient on dielectric breakdown in Ni–Ga 2 O 3 Schottky diodes

Ga 2 O 3 unipolar devices are of high interest due to their ~8 MV/cm predicted breakdown fields, which have not yet been achieved due to premature device failure. Pre- and post-failure defect analysis of Ni–Ga 2 O 3 Schottky diodes in ultrahigh vacuum (UHV) and air were performed using depth-resolved cathodoluminescence, high angle annular dark field scanning transmission electron microscopy, and energy dispersive x-ray analysis to understand the physical mechanisms that precede premature breakdown. The breakdown voltage in UHV was dramatically reduced by nearly 40% compared with the breakdown in air. This reduction in the breakdown voltage correlated with post-breakdown differences in Ni distribution, indicating that the coordination and bonding of Ni contribute strongly to electrical behavior in Ni–Ga 2 O 3 Schottky diodes. Breakdown studies in UHV revealed that Ni diffuses away more from the metal–semiconductor interface than with air breakdown, where Ni localizes more near the interface, indicative of the preferential formation of a Ni oxide under O-poor conditions. These measurements also identified the formation of divacancy-interstitial complexes and their characteristic luminescence signature ~150 nm from the interface, the densities of which correlated with breakdown fields. These findings show that electric-field-induced degradation occurs via the rearrangement of native point defects, which act as an additional precursor to device failure. Macroscopically, they show the impact of both vacuum conditions and metal reactivity on Ga 2 O 3 device fabrication.

36 MATERIALS SCIENCE↗

NREL Validation of S3.2 and S3.3 (CRADA Final Report)

The scope of work for S3.2 and S3.3 validation includes cooperative planning, execution, and analysis of all recommended and agreed-upon test protocols to determine the suitability of the product for long-term deployment of the photovoltaic modules to a broad range of climates. The test plan will be established within two months of project initiation, and NREL will write monthly reports for the duration of the work.

14 SOLAR ENERGY↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational modeling of graphite degradation in molten salt reactors: Role of infiltration

Molten salt reactors (MSRs) often employ graphite as a moderator and reflector. An important challenge for deploying graphite in these reactors is that, due to limited experimental data, our understanding of graphite’s structural integrity in molten salt environments remains incomplete. Here, this study addresses heat generation from fuel-bearing salt that has infiltrated open pores in the graphite, driven primarily by pressure differentials. This is one of multiple identified physical and chemical mechanisms through which molten salt could potentially degrade graphite. Thermally driven stresses are quantified using the Molten-Salt Reactor Experiment (MSRE) graphite moderator elements as a case study. Finite element simulations predict stress distributions at varying infiltration levels, indicating that thermal stresses increase with higher infiltration. Rare-event simulations using the parallel subset simulation framework identify the combinations and corresponding ranges of input parameters that lead to stresses above a specified threshold. In particular, combinations involving high infiltration amounts, high power density, and low thermal conductivity tend to induce the highest stresses. Under the inputs and assumptions considered in this work, the magnitudes of the thermally driven stresses are quite low, with a very low likelihood of causing failure due to exceeding the graphite’s tensile strength. Additionally, rare-event simulations were performed for two more scenarios: a scaled-up moderator geometry and a localized hotspot in the original geometry. Both cases resulted in increased susceptibility to failure, though not to a detrimental extent. Furthermore, the combined effects of irradiation and infiltration-induced thermal stresses were evaluated. The results showed that thermal stresses from infiltration were negligible compared to those caused by irradiation. The findings of such a study are inherently component-specific, but the methodology presented here could be used for similar assessments of salt-infiltration effects in other graphite components.

36 - MATERIALS SCIENCE↗

Evidence of non-isentropic release from high residual temperatures in shocked metals measured with ultrafast x-ray diffraction

Shock experiments are widely used to understand the mechanical and electronic properties of matter under extreme conditions. However, after shock loading to a Hugoniot state, a clear description of the post-shock thermal state and its impacts on materials is still lacking. We used diffraction patterns from 100-fs x-ray pulses to investigate the temperature evolution of laser-shocked Al–Zr metal film composites at time delays ranging from 5 to 75 ns driven by a 120-ps short-pulse laser. We found significant heating of both Al and Zr after shock release, which can be attributed to heat generated by inelastic deformation. A conventional hydrodynamic model that employs (i) typical descriptions of Al and Zr mechanical strength and (ii) elevated strength responses (which might be attributed to an unknown strain rate dependence) did not fully account for the measured temperature increase, which suggests that other strength-related mechanisms (such as fine-scale void growth) could play an important role in thermal responses under shock wave loading/unloading cycles. Our results suggest that a significant portion of the total shock energy delivered by lasers becomes heat due to defect-facilitated plastic work, leaving less converted to kinetic energy. This heating effect may be common in laser-shocked experiments but has not been well acknowledged. High post-shock temperatures may induce phase transformation of materials during shock release. Another implication for the study is the preservability of magnetic records from planetary surfaces that have a shock history from frequent impact events.

42 ENGINEERING↗

Dynamic response of 17-4 stainless steel as a function of manufacturing method and heat treatment

We present a series of plate-impact experiments on 17-4 stainless steel to study the effect of manufacturing method and heat treatment on the Hugoniot elastic limit (HEL), Hugoniot, phase transformation stress, and spallation strength. Two traditional manufacturing methods were considered, wrought processing and casting, as well as two additive manufacturing methods, laser powder-bed fusion (LPBF) and wire-fed electron beam (EBAM). For both LPBF and EBAM 17-4 stainless steel variants, two billets were printed, enabling the application of two unique heat treatments. The HEL stress depended heavily on the thermal history, with the HEL increasing after the formation of Cu-rich precipitates via heat treatment. The Hugoniot response both below and above the phase transition was unaffected by the manufacturing method or heat treatment. The phase transition stress depended heavily on the thermal history, with its variation being attributed to the presence of various microstructural features. This is supported by a marked increase in the phase transition stress after precipitation hardening. These results suggest that the notion of the phase transition stress being dictated by bulk composition is an oversimplification and the stress fields generated by the meso-scale structure are a dominant force. The spallation strength was lower in the cast material compared to all other 17-4 stainless steel variants due to the presence of brittle δ-ferrite inclusions. Additionally, a drop in the tensile strain-rate was observed in the spallation response above the phase transition stress, which was hypothesized to stem from the kinetics of the reversion to the low-pressure phase during spall.

Compressive stress↗

Accelerated Lifetime Testing of Main Shaft Seals for Tidal Turbine Rotors

This document will briefly discuss the observations and results from an NREL conducted accelerated lifetime testing of the main shaft seal for the Verdant Power fifth generation Gen5 underwater Tidal Energy Converter (TEC) turbine, which successfully performed at the RITE project in 2020-2021. In order to evaluate a 5-year Service Interval ( SI) for this component, testing at NREL operated the main shaft seal nearly continuously for over 135 (text says 130 days on page 5 and 125 days on page 7 and 137 days on page 11) days at a rotational velocity of 160 rpm while the test stand recorded water pressure, barrier fluid pressure, temperature, and number of cycles., representing ~ 40% of the SI. An additional separate test was conducted to measure the aging behavior of the rubber drive rings. The water pressure reservoir was held constant as 29 psi. Barrier fluid pressure remained relatively constant throughout the duration of the test but was seen to sink to as low as 10.1 psi. No barrier fluid leakage was observed throughout the test. A sudden failure occurred within the seal after the power to test machine was interrupted for a scheduled building maintenance procedure. Upon restarting, the main shaft seal lost all ability to prevent water ingress. The exact cause is not known but is believed to be either a seal assembly issue or a change in the alignment of the seal components during or following the power outage. Following seal disassembly, significant wear was seen on one of the graphite sealing rings. Based on these results it is recommended that a follow-on TEAMER be conducted to rectify protocol and assembly issues to further evaluate SI of this component. The support and participation of Verdant Power Inc, Dovetail Solutions LLC and Garlock Manufacturing Inc were instrumental in understanding the results. NREL thanks them for their significant effort.

13 HYDRO ENERGY↗

An Operations and Maintenance Roadmap for U.S. Offshore Wind: Enabling a Cost-Effective and Sustainable U.S. Offshore Wind Energy Industry Through Innovative Operations and Maintenance

The United States is currently targeting 30GW of offshore wind to be installed by 2030, and 150GW by 2050. Even considering future turbine sizes, this represents thousands of new turbines installed in a diverse set of environments, each with their unique design, installation, and maintenance challenges. While much can be learned from European and Asian experience with offshore wind over the past two decades, it is important to understand the unique circumstances of the U.S. This document explores operations and maintenance of offshore wind energy, specific to the U.S. and attempts to lay out a roadmap for needed activities to ensure reliability of future installations. The roadmap was informed through dozens of interviews with a wide cross-section of the industry, including representatives from OEMs, owner/operators, service companies, certification agencies, service providers, and researchers. The roadmap first describes the problem by component - blades, drivetrain and nacelle, structures and foundations, and electrical systems - through a look at current practices and opportunities for improvement in the areas of Failure Mode Analysis and Mitigation; Monitoring, Sensing, and Inspection; and Maintenance Execution. Crosscutting areas of Digitalization, Robotics and Automation, Prognostics and Health Management and O&M Optimization, Experimentation and Demonstration, Standardization, and Design Optimization Considering Reliability and O&M are then discussed. Finally, the roadmap summarizes all of these topics with recommendations for short (1-3 years), medium (4-7 years), and long term (8-12 years) activities, with a description of needed public and private sector contributions.

17 WIND ENERGY↗

Engineering in Cyber Resilience with Cyber-Informed Engineering

Engineers have super powers to provide cybersecurity resilience with deterministic engineering solutions and to protect systems from the most catastrophic consequences that a cyber saboteur could cause. Come to this session to learn how to use engineering risk management skills to harden your engineered systems from cyberattacks. Objective 1 Identify what system functions could be digitally induced to cause undesired high-impact consequences. Objective 2 Analyze how loss or instability of digital controls in a subsystem could lead to high-impact consequences. Objective 3 Analyze how loss or instability in the digital connectivity between systems could lead to high-impact consequences. Objective 4 Identify engineering controls which could build resilience by eliminating digital loss or instability pathways or reduce the impact of digital loss or instability. This presentation will introduce Cyber-Informed Engineering, described below, and walk participants through specific engineering use cases to show how engineers can consider the potential for cyber sabotage in their existing system designs and enact deterministic engineering-based controls which eliminate pathways for attack or mitigate specific consequences. A wide variety of application use cases will be considered so that audience members can align the material with familiar engineering applications. CIE is an engineering approach that integrates cyber resilience into the conception, design, build, and operation of any physical system that has digital connectivity, sensors, monitoring, or control. CIE offers the opportunity to use engineering to eliminate or mitigate avenues for cyber attack—starting from the earliest stage of design and continuing throughout the system’s lifecycle. Today, engineers and industrial control system (ICS) technicians build engineered systems with specific goals for safety, reliability, and functionality. While systems engineering includes considerable safety and failure mode analysis, cybersecurity risks are often not specifically addressed—particularly the risks of intentional cyber compromise, exploitation, and misuse. Cyber-Informed Engineering pairs well with traditional cyber defenses and offers an extra designed-in protection to eliminate the most catastrophic consequences which can be realized by an adversary should traditional cyber defenses fail.

42 ENGINEERING↗

Hydrogen Component Reliability Database (HyCReD)

The Hydrogen Component Reliability Database (HyCReD) is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety reliability for hydrogen facilities by integrating risk reduction methodologies and component reliability data taxonomies that support hydrogen infrastructure failure rate analysis.

availability↗

Addressing Failures in Molten Salt Thermal Energy Storage Tank for Central Receiver Concentrating Solar Power Plants

The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.

concentrating solar power↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗