Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Time-temperature-stress superposition of PBX 9502 compressive creep data for lifetime predictions

The plastic-bonded explosive (PBX) 9502 is a viscoelastic, high-solids loaded polymer bound composite comprised of 95 weight% (wt%) TATB explosive crystals and 5 wt% FK-800 polymer binder. The uniaxial quasi-static mechanical properties have been studied and characterized extensively over 25+ years, including creep. Creep is the strain evolution over time as a result of an asymmetric load typically at temperatures above ambient. Creep measurements to failure can take excessively long periods of time depending on various factors including applied stress, temperature, and loading rate that render a single test to failure impossible. Using the principles of time-temperature-stress superposition (TTSSP), short-term creep tests at various applied stresses and temperatures can be used for long-term creep predictions. The TTSSP model shifts short-term test data using two factors, one for temperature and stress, creating a master curve at a reference test condition. The master curve can be shifted to predict the creep response at any desired test condition. PBX 9502 compression specimens were tested at three temperatures and various applied stresses. This work discusses the TTSSP analysis of PBX 9502 compressive creep data to create a single comprehensive master curve.

36 MATERIALS SCIENCE↗

Time-Temperature-Stress Superposition of PBX 9502 Compressive Creep Data for Lifetime Predictions

The plastic-bonded explosive (PBX) 9502 is a viscoelastic, high-solids loaded polymer bound composite comprised of 95 weight% (wt%) TATB explosive crystals and 5 wt% FK-800 polymer binder. The uniaxial quasi-static mechanical properties have been studied and characterized extensively over 25+ years, including creep. Creep is the strain evolution over time as a result of an asymmetric load typically at temperatures above ambient. Creep measurements to failure can take excessively long periods of time depending on various factors including applied stress, temperature, and loading rate that render a single test to failure impossible. Using the principles of time-temperature-stress superposition (TTSSP), short-term creep tests at various applied stresses and temperatures can be used for long-term creep predictions. The TTSSP model shifts short-term test data using two factors, one for temperature and stress, creating a master curve at a reference test condition. The master curve can be shifted to predict the creep response at any desired test condition. PBX 9502 compression specimens were tested at three temperatures and various applied stresses. This work discusses the TTSSP analysis of PBX 9502 compressive creep data to create a single comprehensive master curve.

36 MATERIALS SCIENCE↗

Predicting EBC Temperature Limits for Industrial Gas Turbines

Higher turbine inlet temperatures may require the use of ceramic matrix composites (CMC) such as SiC/SIC, which require environmental barrier coatings (EBCs) to protect them against the detrimental effect of water vapor. Here, the goal of this project is to determine the maximum bond coating temperature for EBCs for land-based turbines, where the minimum coating lifetime is 25,000 h. If the temperature exceeds the 1414°C melting point of the Si bond coating, then coatings without a bond coating also need to be evaluated. Thus, current Yb 2 Si 2 O 7 EBCs with a Si bond coating and next-generation EBCs without a Si bond coating are being evaluated in laboratory testing using 1-h cycles in air+90%H 2 O. For this initial work, coatings were deposited on CVD SiC coupons. Reaction kinetics at 1250°, 1300° and 1350°C have been evaluated by measuring the thickness of the thermally grown silica scale after 100–500 h exposures. For comparison, scale growth rates for uncoated SiC and Si specimens in dry and wet environments were included as minimum and maximum values, respectively. Based on a critical scale thickness failure criteria, estimated maximum temperatures were calculated for both EBC systems using this initial data.

42 ENGINEERING↗

Plastic deformation of single crystals of the equiatomic Cr-Mn-Fe-Co-Ni high-entropy alloy in tension and compression from 10 K to 1273 K

In this report the plastic deformation behavior of single crystals of the quinary, equiatomic Cr-Mn-Fe-Co-Ni high-entropy alloy (HEA) with the face-centered cubic structure has been investigated in tension and compression as a function of crystal orientation and temperature from 10 K to 1373 K. The critical resolved shear stress (CRSS) for {111}<110> slip at room temperature is 42-45 MPa. It does not depend much on crystal orientation (i.e., the Schmid law holds true) and the sense (tension vs. compression) of the applied load. The CRSS for {111}<110> slip increases with the decrease in temperature, without showing any significant inertia effects at cryogenic temperatures below 77 K. Extrapolation from the measured yield stresses down to 10 K yields a CRSS value at 0 K of 168 MPa. At cryogenic temperatures, the measured strain-rate sensitivity of flow stress is consistent with a very small activation volume. The concept of stress equivalence holds true both for the temperature dependence of CRSS and the stress dependence of activation volume, indicating that solid-solution hardening is the major strengthening mechanism. Deformation twinning occurs at 77 K but not at room temperature, resulting in higher tensile elongation to failure at 77 K than at room temperature. Deformation twinning at 77 K occurs at a shear stress of 378 MPa on conjugate ($\bar1\bar11$) planes in the form of Lüders deformation after large plastic strain (about 85%) achieved by the stage I (easy glide) and stage II (linear work-hardening) deformation.

36 MATERIALS SCIENCE↗

Report on FY 2023 Research and Development on Specially Designed Creep-fatigue Experiments on Alloy 617 in Support of Improving Creep-fatigue Evaluation Approaches

Experimental and numerical studies in support of developing the integrated Elastic–Perfectly Plastic (EPP) plus Simplified Model Test (SMT) design methodology, referred to as the EPP+SMT method, continued in FY 2023. This report focuses on the methods for extrapolating the EPP+SMT creep-fatigue life curves at long hold times and low strain ranges at elevated temperatures. In this work, the available uniaxial creep-fatigue failure data on Alloy 617 at temperatures of 950°C and 850°C were analyzed to provide a guidance on the development of the extrapolation method and the creep-fatigue failure criteria. A viscoplastic constitutive model for Alloy 617 was adopted to extrapolate the mechanical responses to low strain ranges and long hold times. A set of design curves of Alloy 617 at temperatures of 950°C, 850°C, and 800°C with tensile hold times of 1 hr, 100 hr, and 1,000 hr are developed. Furthermore, creep-fatigue testing on two notch specimen geometries, shallow-notch and sharp V-notch, on Alloy 617 was performed 950°C to understand the multiaxial stress relaxation behavior. The experimental and numerical results on the notch specimens were compared with those on the standard uniaxial smooth bar specimens. The effect of multi-axial stress state combined with elastic follow-up on the stress relaxation behavior was investigated in this report.

36 MATERIALS SCIENCE↗

Design of a 2 MW ZrC/W-based molten-salt-to-sCO 2 PCHE for concentrated solar power

To increase the power cycle efficiency and lower the levelized cost of electricity (LCOE) of concentrated solar power (CSP) plants, printed circuit heat exchangers (PCHEs) capable of operating above 700 °C with molten chloride salt and a sCO 2 -based fluid are needed. In this paper, the design of a high-pressure, high-temperature, 2 MW PCHE comprised of a thermomechanically-robust, zirconium carbide/tungsten (ZrC/W) composite is conducted for CSP plants. The ZrC/W composite is a material with high thermal conductivity, high stiffness, and high failure strength at high temperatures, along with excellent resistance to thermal cycling and thermal shock. In this work, a thermomechanical design analysis was conducted to select appropriate material thicknesses of the ZrC/W plates, and to determine the geometrical dimensions and the thermal performance of the PCHE. The influences of the plate number and heat exchanger length on power density and pressure drop have also been systematically investigated. Economic analyses were conducted to compare the cost of ZrC/W-based PCHEs to those comprised of IN740H (a state-of-the-art, nickel-based superalloy) and 316 stainless steel (316SS). Finally, at a sufficiently high plate production rate, the manufacturing cost of ZrC/W-based PCHEs can be significantly lower, while achieving a much higher power density, compared with state-of-the-art, nickel alloy-based and stainless steel-based PCHEs.

14 SOLAR ENERGY↗

Effects of Heat Pipe Failures in Microreactors

Microreactors provide new opportunities for nuclear reactor applications given their long-lived fuel source, compact size, portability, reliability as it relates to safety and their self-regulating nature. To take advantage of these opportunities there are technological challenges that need to be overcome. One advancing technology often used in conjunction with microreactor designs are heat pipes, which are used for heat removal from the reactor core to the power conversion system. Heat pipes are a substitute for the traditional system in which the same fluid used as coolant in the reactor is then used as the working fluid in the power conversion system. This document describes how heat pipes operate, what happens when a heat pipe fails, and what codes can be used to simulate the results. Our analyses show that a single/double heat pipe failure results in a temperature increase of 15-50°C respectively in surrounding heat pipes. Heat pipe microreactors could be easily designed such that this increase is within the maximum parameters allowable for safety and does not result in cascading heat pipe failure. Thus, such failures do not lead to severe degradation of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Temperature Optocoupler for 3D High Density Power Modules

The goal of this proposed research is to develop a reliable high-temperature optocouplers, which can operate at 250°C with at least ten-year lifetime, and replace isolation transforms as the galvanic isolation solution for the 3D integration of high density power modules. The electrification of future transportations (i.e., electric vehicles) will continuously drive the demand for high density power modules. Optocouplers (i.e., packaged light emitter and detector) as a promising candidate to replace bulky isolation transformers are highly desirable to facilitate the continuous scale-down of gate driver circuitry that will lead to 3D high density power modules and achieve disruptive performance in terms of thermal management, power density, power efficiency, reliability and operating environments. However, regular semiconductor optoelectronic materials and devices have significant difficulty functioning in the harsh environments designated for high density power module usage (such as operation at high temperatures). Ultimately, it is not the intrinsic properties of power devices that prevent their use at higher temperatures, but rather the low voltage electronics needed to drive them and the packaging that surrounds them. The typical operating temperature for optocouplers is only up to 100°C, due to the limitations of light emitting diode (LED) devices inside and packaging materials. A systematic characterization methodology will be developed to analyze the performance, lifetime and reliability of LED devices and distinguish multiple failure mechanisms at high temperatures. An original methodology of “design for reliability” will be developed to design the optoelectronic devices with high reliability and long lifetime at high temperatures. A new architecture of high temperature high reliable optocouplers will be developed, fabricated and demonstrated with continuous operating at 250°C. The development of efficient, reliable high density 3D power modules is the foundation for energy efficiency and energy reliability. Enabled with advanced 3D integration and packaging technologies, high density power module solutions can achieve much more superior performance over the conventional discrete solutions in terms of efficiency, thermal management and power density. The proposed concept of high temperature optocouplers as the galvanic isolation solution for high density power modules will bring together interdisciplinary research involving the wide bandgap materials, optoelectronics, high reliable device design, electronics packaging and power modules. A streamline of skilled personnel would be trained including graduate and undergraduate students, local engineers and scientists which are in great demand to both academia and optoelectronics industry. The proposed research topics, such as, solid state lighting and high temperature device reliability, are currently of major interest at the Department of Energy, in particular, Sandia National Laboratories. This project can enhance collaborations between the University of Arkansas (UA) and Sandia National Laboratories. The findings of the proposed research are expected to be integrated into high density 3-D power modules at the Engineering Research Center for Power Optimization for Electro-Thermal Systems (POETS).

42 ENGINEERING↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

LANL Phase 3 Container Loading in Support of the Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers

The PCV/SCV/3013 Thermal Test Program is intended to determine the pressure response of packaged 3013 containers when exposed to a facility fire in the K-Area Complex (KAC) at the Savannah River Site. The fire tests support the KAC safety basis and must be bounding of the maximum pressure that would result from any 3013 container exposed to a KAC facility fire. The testing program has the following objectives: “To increase understanding of the pressure and temperature conditions at which failure occurs; To determine the allowable moisture for which failure will not occur under specified fire conditions, and; To increase understanding regarding the effects of salts on the pressurization, corrosion, and potential failure of the container.”

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal-hydraulics capabilities in predicting the post-CHF conditions

Developing research in a time-at-temperature limit for fuel failure requires assessing both the material modeling and the thermal-hydraulic modeling capabilities. Predictions of post-CHF conditions have areas for development leveraging experiments, code coupling, and general model improvement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temperature and radiation effects on brittle versus ductile fracture behavior in miscible phase boundaries: insight from atomistic simulations

Temperature- and irradiation-assisted failure mechanisms in miscible phase boundaries are clarified via atomistic calculations. We first establish the temperature-dependent brittle-to-ductile transition in U–Zr miscible phase boundaries. Our results confirm that these boundaries are mostly brittle at low temperatures and ductile at elevated temperatures. We then investigate the changes induced by irradiation on the fracture mechanisms in such phase boundaries. The irradiation-induced defect accumulation follows a multi-stage process that starts with the accumulation of isolated small dislocation loops before transitioning to the saturation and growth of larger dislocation loops and end up with a reorganization into forest dislocations. The accumulation of loops is the primary feature to participate in the delineation between brittle and ductile interfacial fracture in irradiated phase boundaries. At low damage levels, radiation defect interactions with the crack tip are limited and U–Zr miscible boundaries fail through the emission of dislocations ahead of the crack tip followed by brittle cleavage in agreement with the classical Griffith’s criterion for crack stability. At higher damage levels, the failure mode transitions from brittle crack growth to ductile void growth. In this case, the microcrack tip is blunted by the high density of pre-existing, radiation-induced defects in the vicinity of the crack. This interaction leads to the development and growth of a cavity at the interface as opposed to interfacial cleavage.

36 MATERIALS SCIENCE↗

Anharmonic Origin of the Giant Thermal Expansion of NaBr

ll phonons in a single crystal of NaBr are measured by inelastic neutron scattering at temperatures of 10, 300, and 700 K. Even at 300 K, the phonons, especially the longitudinal-optical phonons, show large shifts in frequencies and show large broadenings in energy owing to anharmonicity. Ab initio computations are first performed with the quasiharmonic approximation (QHA) in which the phonon frequencies depend only on V and on T only insofar as it alters V by thermal expansion. This QHA is an unqualified failure for predicting the temperature dependence of phonon frequencies, even 300 K, and the thermal expansion is in error by a factor of 4. Ab initio computations that include both anharmonicity and quasiharmonicity successfully predict both the temperature dependence of phonons and the large thermal expansion of NaBr. The frequencies of longitudinal-optical phonon modes decrease significantly with temperature owing to the real part of the phonon self-energy from explicit anharmonicity originating from the cubic anharmonicity of nearest-neighbor NaBr bonds. Anharmonicity is not a correction to the QHA predictions of thermal expansion and thermal phonon shifts but dominates the behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The deformation and burst behavior of Zircaloy-4 cladding tubes with hydride rim features subject to internal pressure loads

This study is motivated by the desire to conduct a separate effects test replicating specific aspects of an in-pile pulse reactor test on high exposure light water reactor (LWR) fuel rods. The principal purpose of the tests was to determine whether temperature and or hydrogen concentration thresholds exist in assessing the vulnerability of a stress relieved zirconium alloy cladding tubes to low strain ruptures. A secondary objective was to determine whether observations of the cladding stress during deformation could aid in the understanding of the crack formation and propagation in cladding tubes with hydride rim features. Here, the study utilized artificially hydrided Zircaloy-4 cladding tubes and an isothermal, internal pressure test that was controlled with an in-situ strain measurement. The test results show a clear transition in failure vulnerability between room temperature and 150 °C. Below 150 °C, cladding tubes rupture at very low uniform plastic strain—even at relatively modest cladding hydrogen levels. At and above 150 °C, cladding tubes only rupture at low uniform plastic strain if the cladding hydrogen content is greater than 500 ppm and usually experience at least some modest amount of plastic deformation prior to rupture. Post-test metallographs from non-ruptured cladding tubes show numerous primary cracks forming in the hydride rim and arresting at the metal/hydride interface. This observation combined with the decrease in bulk yielding of hydrided cladding tubes when compared to fresh non-hydrided tubes leads to the conclusion that the fracture stress of the hydride rims is related to and bounded by the yield stress of the zirconium metal. Some evidence is presented for a change in crack propagation mechanism from one of void formation on hydride plates and linkage at temperatures below 150 °C to more classical ductile shearing beneath the primary crack tip at temperatures above 150 °C. This apparent change in crack propagation mechanism may help explain the observed temperature and hydrogen concentration thresholds.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photovoltaic Inverter Failure Mechanism Estimation Using Unsupervised Machine Learning and Reliability Assessment

This article introduces a data-driven approach to assessing failure mechanisms and reliability degradation in outdoor photovoltaic (PV) string inverters. The manufacturer's stated PV inverter lifetime can vary due to the impact of operating site conditions. To address limitations in degradation estimation through accelerated testing, condition monitoring, or degradation modeling, we propose a machine learning (ML) oriented approach. Utilizing data from a 1.4 MW PV power plant operational since 2016, with 46 string PV inverters tied to the grid, we employ the unsupervised one-class support vector machine ML technique to analyze inverter and sensor data, capable of classifying humidity cycling and temperature fluctuations as dominant failure mechanisms. Utilizing the anomaly alert relationship and alert details specific to the inverter, the level of PV inverter output is considered as its availability or available reliability. Subsequently, a continuous Markov model is applied to six-month alert data, revealing an average stated reliability of 20% after 20 years of continuous operation. These results support recommendations for time-bound preventive measures to enhance PV inverter reliability under diverse outdoor conditions. Furthermore, the approach provides a nondestructive, top–down, and generalized method for analyzing any commercial PV inverter exposed to outdoor conditions, contingent on the availability of relevant data.

14 SOLAR ENERGY↗

Impact of Heaters on Molten Salt Reactors Dynamics

Recently, there has been renewed interest in the Molten Salt Reactor (MSR) concept. This interest is mainly due to its advantages over Light Water Reactors (LWRs). Among these advantages are the flexibility in the fuel choice and the possibility to burn actinides [1]. Currently, two molten research reactors are under development. A 2 MW molten salt experimental reactor has been constructed and is planned for operation in China. A 1 MW Molten Salt Research Reactor is under construction in the United States [2]. Thus, Research and Development (R&D) programs are needed for the MSR technology. Reactor dynamics studies are crucial safety evaluation studies. The development of reactor dynamics tools for MSRs started during the Molten Salt Reactor Program (MSRP) at ORNL, focusing on the Molten Salt Reactor Experiment (MSRE) [3]. Although various dynamic simulation tools are available, R&D efforts to develop specialized tools for MSRs are still ongoing [4]. The primary motivation for this interest is the goal of commercializing MSRs. Developing a dynamics tool for MSRs is crucial for analyzing their safety and supporting their demonstration efforts. A crucial safety issue in MSRs is ensuring that the fuel salt in the primary loop remains molten. This concern becomes particularly important when the reactor operates at lower power levels. Most chloride and fluoride salts used as fuel have a melting point of approximately 450 °C [5]. Therefore, maintaining fuel salt temperatures above this melting point is essential to prevent it from freezing. Freezing of the fuel salt can lead to volume expansion, potentially causing damage to reactor components [6]. Moreover, it can create local blockages within fuel salt channels, reducing cooling efficiency and resulting in hot spots [7]. Various methods can prevent fuel salt from freezing at low power levels. These include reducing the fuel mass flow rate in the primary loop, decreasing heat exchange between the primary and secondary loops in the reactor, and using electric fuel salt heaters. Reducing the mass flow rate of fuel salt in the primary loop can increase the fuel salt transit time in the core, enhancing heat production and increasing temperature. However, it can potentially lead to challenges. These include increasing the potential for fuel salt deposition on the reactor channel walls [8], affecting the overall heat transfer processes. Thus, alternative methods should be used [9]. This research investigates the effects of fuel salt heaters on the dynamics and stability during MSR operation. The investigation includes studying the reactor stability with the fuel salt heaters on and off. In addition, the reactor response to transients is compared with and without the operation of fuel salt heaters. These transients include reactivity insertion, primary and secondary pump failure, and heat sink temperature increase. The results of the reactivity insertion transient are presented in the summary.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Novel Concentrating Solar Weathering Apparatus for Experimental Validation of Multi-Modal Degradation Models

High-performance coatings for Concentrating Solar Power (CSP) receivers are subjected to remarkable environmental stressors during normal operations. Applied to the receiver tubes, these coatings serve to maximize the solar absorptivity of the receiver, transferring as much heat as possible from the solar collectors into the heat-transfer fluid (HTF). The lifecycle of these coatings is not well-defined, and the harsh operational conditions make them difficult to test. NREL has designed, built, and tested an apparatus to expose these samples to design levels of environmental stress and well beyond, into accelerated and destructive conditions. The chamber is actively cooled, monitored, and has the capability to supply humidification for cycling tests, allowing us to test multi-modal degradation and failure conditions at high temperature, high flux, and high humidity conditions. These conditions can catalyze high-temperature oxidation, mechanical degradation, and other modes of absorptivity loss seen in selective solar receiver coatings. The experimental data can feed lifecycle models for expensive and necessarily resilient materials, offering insights to aid maintenance schedules, technoeconomic analysis, and material industry performance benchmarks. This presentation will demonstrate the apparatus design and performance, as well as initial results for aging on a selective receiver coating.

14 SOLAR ENERGY↗