Search NASA⌕ Search

SEARCH · Search NASA

Results for “fan efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Aerodynamic Performance of an Over-the-Rotor Liner With Circumferential Grooves on a High Bypass Ratio Turbofan Rotor

While liners have been utilized throughout turbofan ducts to attenuate fan noise, additional attenuation is obtainable by placing an acoustic liner over-the-rotor. Previous experiments have shown significant fan performance losses when acoustic liners are installed over-the-rotor. The fan blades induce an oscillating flow in the acoustic liners which results in a performance loss near the blade tip. An over-the-rotor liner was designed with circumferential grooves between the fan blade tips and the acoustic liner to reduce the oscillating flow in the acoustic liner. An experiment was conducted in the W-8 Single-Stage Axial Compressor Facility at NASA Glenn Research Center on a 1.5 pressure ratio fan to evaluate the impact of this over-the-rotor treatment design on fan aerodynamic performance. The addition of a circumferentially grooved over-the-rotor design between the fan blades and the acoustic liner reduced the performance loss, in terms of fan adiabatic efficiency, to less than 1 percent which is within the repeatability of this experiment.

Bozak, Richard F.↗

The Aerodynamic Performance of an Over-The-Rotor Liner with Circumferential Grooves on a High Bypass Ratio Turbofan Rotor

While liners have been utilized throughout turbofan ducts to attenuate fan noise, additional attenuation is obtainable by placing an acoustic liner over-the-rotor. Previous experiments have shown significant fan performance losses when acoustic liners are installed over-the-rotor. The fan blades induce an oscillating flow in the acoustic liners which results in a performance loss near the blade tip. An over-the-rotor liner was designed with circumferential grooves between the fan blade tips and the acoustic liner to reduce the oscillating flow in the acoustic liner. An experiment was conducted in the W-8 Single-Stage Axial Compressor Facility at NASA Glenn Research Center on a 1.5 pressure ratio fan to evaluate the impact of this over-the-rotor treatment design on fan aerodynamic performance. The addition of a circumferentially grooved over-the-rotor design between the fan blades and the acoustic liner reduced the performance loss, in terms of fan adiabatic efficiency, to less than 1% which is within the repeatability of this experiment.

Bozak, Rick↗

Performance Calculations for a Boundary-Layer-Ingesting Fan Stage from Sparse Measurements

A test of the Boundary Layer Ingesting-Inlet / Distortion-Tolerant Fan was completed in NASA Glenn's 8-Foot by 6-Foot supersonic wind tunnel. Inlet and fan performance were measured by surveys using a set of rotating rake arrays upstream and downstream of the fan stage. Surveys were conducted along the 100 percent speed line and a constant exit corrected flow line passing through the aerodynamic design point. These surveys represented only a small fraction of the data collected during the test. For other operating points, data was recorded as snapshots without rotating the rakes which resulted in a sparser set of recorded data. This paper will discuss analysis of these additional, lower measurement density data points to expand our coverage of the fan map. Several techniques will be used to supplement the snapshot data at test conditions where survey data also exists. The supplemented snapshot data will be compared with survey results to assess the quality of the approach. Effective methods will be used to analyze the data set for which only snapshots exist.

fan efficiency↗

Large-Scale Boundary Layer Ingesting Propulsor Research

NASA’s Advanced Air Transport Technology (AATT) project is investigating boundary layer ingesting (BLI) propulsors for advanced subsonic commercial vehicle concepts to enable the reduction of fuel burn. A multidisciplinary team of researchers from NASA, United Technologies Research Center (UTRC), Virginia Polytechnic University, and the Air Force Arnold Engineering Development Complex developed and tested an embedded BLI inlet and distortion-tolerant fan (BLI2DTF) system in the NASA Glenn Research Center (GRC) 8- foot by 6-foot (8x6) transonic wind tunnel. The test demonstrated the component performance goals necessary for an overall fuel burn reduction of 3 to 5 percent on a large hybrid wing body (HWB) aircraft. Special test equipment, including a raised floor with flow effectors and a bleed system, was developed for use in the 8x6 to produce the appropriate incoming boundary layer representative of an HWB application. Detailed measurements were made to determine the inlet total pressure loss and distortion, fan stage efficiency, and aeromechanic performance including blade vibration stress and displacement response. Results from this test were used as input to a vehicle-level system study performed by the AATT project to assess the impact of BLI on an alternative advanced concept aircraft referred to as the NASA D8 (ND8), which is somewhat similar to the HWB in its integration of the propulsor. This paper will provide an overview of the project timeline, special test equipment needed in the wind tunnel to develop the appropriate incoming boundary layer, and the difficulties in designing a propulsor for the test. The paper will conclude with some representative aerodynamic and aeromechanic data from the test itself and conclude with how this data was used in the ND8 system study.

Aerodynamic performance↗

Large-Scale Boundary Layer Ingesting Propulsor Research

_NASA's Advanced Air Transport Technology (AATT) project is investigating boundary layer ingesting (BLI) propulsors for advanced subsonic commercial vehicle concepts to enable the reduction of fuel burn. A multidisciplinary team of researchers from NASA, United Technologies Research Center (UTRC), Virginia Polytechnic University, and the Air Force Arnold Engineering Development Complex developed and tested an embedded BLI inlet and distortion-tolerant fan (BLI2DTF) system in the NASA Glenn Research Center (GRC) 8-foot by 6-foot (8x6) transonic wind tunnel. The test demonstrated the component performance goals necessary for an overall fuel burn reduction of 3 to 5 percent on a large hybrid wing body (HWB) aircraft. Special test equipment, including a raised floor with flow effectors and a bleed system, was developed for use in the 8x6 to produce the appropriate incoming boundary layer representative of an HWB application. Detailed measurements were made to determine the inlet total pressure loss and distortion, fan stage efficiency, and aeromechanic performance including blade vibration stress and displacement response. Results from this test were used as input to a vehicle-level system study performed by the AATT project to assess the impact of BLI on an alternative advanced concept aircraft referred to as the NASA D8 (ND8), which is somewhat similar to the HWB in its integration of the propulsor. This paper will provide an overview of the project timeline, special test equipment needed in the wind tunnel to develop the appropriate incoming boundary layer, and the difficulties in designing a propulsor for the test. The paper will conclude with some representative aerodynamic and aeromechanic data from the test itself and conclude with how this data was used in the ND8 system study.

Celestina, Mark L.↗

Two-stage fan. 4: Performance data for stator setting angle optimization

Stator setting angle optimization tests were conducted on a two-stage fan to improve efficiency at overspeed, stall margin at design speed, and both efficiency and stall margin at partspeed. The fan has a design pressure ratio of 2.8, a flow rate of 184.2 lb/sec (83.55 kg/sec) and a 1st-stage rotor tip speed of 1450 ft/sec (441.96 in/sec). Performance was obtained at 70,100, and 105 percent of design speed with different combinations of 1st-stage and 2nd-stage stator settings. One combination of settings, other than design, was common to all three speeds. At design speed, a 2.0 percentage point increase in stall margin was obtained at the expense of a 1.3 percentage point efficiency decrease. At 105 percent speed, efficiency was improved by 1.8 percentage points but stall margin decreased 4.7 percentage points. At 70 percent speed, no change in stall margin or operating line efficiency was obtained with stator resets although considerable speed-flow requlation occurred.

Burger, G. D.↗

Conceptual Design of a Counter-Rotating Fan System for Distributed Boundary Layer Ingesting Propulsion

The present paper details the design of the counter rotating fans for a Turboelectric Distributed Propulsion (TeDP) system. Sixteen propulsors installed in mail-slot-shape nacelles are embedded on an aerodynamically optimized hybrid wing-body configuration. The hybrid-wing/body (HWB) configuration which was previously designed to satisfy the conditions of trim, longitudinally static stability and specific cargo space is employed as the baseline configuration in pursuing an optimal distributed propulsion system. A set of distributed propulsors is conceptually designed and the collective performance is evaluated against the target thrust mandated by the mission requirements. The concept of the distributed propulsion allows the fan pressure ratio to be around 1.27~1.32 for the target thrust. In addition, further splitting of the fan pressure ratio by using the counter-rotating fans for each slot realizes the target pressure ratio with low tip speed. In the distributed propulsion system, the nature of the flow conditions and/or the thickness of the ingested boundary layer may differ and result in different propulsive reaction of each individual propulsor. The optimization is, thus, approached from both the propulsion system and individual propulsor perspectives. An optimal distribution of the thrust and power output is determined by how the system utilizes each passage's propulsive characteristics and its interaction with the airframe. These system level analysis and optimization are conducted using an actuator disk model to account for the propulsion-airframe integration numerically. With respect to the propulsor level, aerodynamic shape optimizations of the fan blades are performed in a sequential multi-objective optimization process for various design objectives, such as mass flow rate condition, fan pressure ratio, efficiency and the exit flow angle of the fan stage by using a genetic algorithm, NSGA-II. The radial chord distribution, and meanline distribution of the rotors are designed on the circumferentially averaged axi-symmetric inlet profiles and tested on the six inlet profiles from six divided sectors to reckon flow distortion. The performances of the counter rotating fans are, thus, evaluated accordingly for obtaining distortion tolerant fan. The performance of the distributed propulsion system is evaluated by two CFD tools, i.e., a multi-stage turbo-machinery CFD code and one propulsion-airframe integration flow solver coupled with a body-force model. The optimized boundary layer ingestion propulsion system of 16 distributed slots not only reaches the system target thrust, but also delivers a close to 20% fuel saving benefit against its counterpart 12 distributed clean inlet propulsion system.

Boundary-Layer-Ingestion Propulsion↗

Investigation of Pneumatic Inlet and Diffuser Blowing on a Ducted Fan Propulsor in Static Thrust Operation

Tilting ducted fans present a solution for the lifting and forward flight propulsion requirements of VTOL aircraft. However, the geometry of the duct enshrouding the propeller has great a effect on the efficiency of the fan in various flight modes. Shroud geometry controls the velocity and pressure at the face of the fan, while maintaining a finite loading out at the tips of the fan blades. A duct tailored for most efficient generation of static lifting thrust will generally suffer from performance deficiencies in forward flight. The converse is true as well, leaving the designer with a difficult trade affecting the overall performance and sizing of the aircraft. Ideally, the shroud of a vertical lifting fan features a generous bell mouth inlet promoting acceleration of flow into the face of the fan, and terminating in a converging nozzle at the exit. Flow entering the inlet is accelerated into the fan by the circulation about the shroud, resulting in an overall increase in thrust compared to an open propeller operating under the same conditions . The accelerating shroud design is often employed in lifting ducted fans to benefit from the thrust augmentation; however, such shroud designs produce significant drag penalties in axial flight, thus are unsuitable for efficient forward flight applications. Decelerating, or diffusing, duct designs are employed for higher speed forward flight configurations. The lower circulation on the shroud tends to decelerate the flow into the face of the fan, which is detrimental to static thrust development; however, net thrust is developed on the shroud while the benefits of finite blade loading are retained. With judicious shroud design for intended flight speeds, a net increase in efficiency can be obtained over an open propeller. In this experiment, conducted under contract to NASA LaRC (contract NAG-1-02093) circulation control is being applied to a mildly diffusing shroud design, intended for improved forward flight performance, to generate circulation in the sense of an accelerating duct design. The intent is to improve static thrust performance of a ducted fan tailored for high speed axial flight, while at the same time significantly reduce the pressure signature on the ground plane. Circulation control on the fan shroud is achieved by the Coanda effect.

Kondor, Shayne↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Laboratory Testing of Portable Air Cleaner Products for Energy Efficiency and Clean Air Performance at Various Fan Settings [Slides]

This document contains the results of a product review and laboratory testing experiment of portable air cleaning devices (PACs). Thirty-four commercially available PACs were reviewed, and from those, 7 products were purchased and underwent AHAM AC-7 clean air delivery rate (CADR) testing. The following research questions were explored: 1) What is the relationship between clean air delivery rate (CADR) and energy across a range of products and what is the general decrement in CADR as a result of operating at lower fan speeds? 2) How might the multiple units at lower power compare to fewer, larger units at full power in terms of energy efficiency and total cost? 3) How do the measured CADR, power, and efficiency compare to the manufacturer specs? 4) Are there product attributes that can be identified that might contribute to better CADR/W performance?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fan and pump noise control

The development is described of improved, low noise level fan and pump concepts for the space shuttle. In addition, a set of noise design criteria for small fans and pumps was derived. The concepts and criteria were created by obtaining Apollo hardware test data to correlate and modify existing noise estimating procedures. A set of space shuttle selection criteria was used to determine preliminary fan and pump concepts. These concepts were tested and modified to obtain noise sources and characteristics which yield the design criteria and quiet, efficient space shuttle fan and pump concepts.

Misoda, J.↗

Quiet Spacecraft Cabin Ventilation Fan Development: Motivation and Context

It is important to control acoustical noise aboard crewed space vehicles and space habitats to provide a satisfactory environment for voice communications, alarm audibility, and restful sleep, and to minimize the risk for hearing loss and annoyance. As with most noise control efforts, it is best to control the noise at the source, and for spaceflight vehicles these are typically the fans associated with the Environmental Control and Life Support system. These include cabin ventilation fans and intermodule ventilation fans, among others. Throughout the history of crewed spaceflight, there have been issues with noise from ventilation fans, going back to Apollo. And, with the spaceflight vehicles and habitats currently being developed, there are again concerns with noise from ventilation fans. To address this problem, NASA is working to leverage the technology developed in its Aeronautics Research Mission Directorate, specifically at the Glenn Research Center, to design highly efficient and quiet fans for reducing community noise levels from civilian aircraft. This paper will discuss the need for transfer of this technology to spaceflight use, and will discuss the potential benefits, which are significant and will be crucial for the successful development and operations of future spaceflight vehicles, space suits, and habitats.

Christopher S. Allen↗

Aerodynamic Design and Optimization of Fan Stage for Boundary Layer Ingestion Propulsion System

The present paper addresses the process of preliminary design of a low-pressure fan and outlet guide vane (OGV) of a boundary layer ingestion (BLI) propulsion system. The tail-cone thruster systems of NASA's STARC_ABL (Single-aisle Turboelectric Aircraft with an Aft Boundary-Layer propulsor) adopts an axi-symmetric BLI type inlet as opposed to other embedded engine systems. Thus, the focus of the present work is placed on maximizing the efficiency of the fan and OGV stages under a significant radial distortion. A parameterization with B-spline function for camber line angles, metal chord, thickness distribution and stacking axis of blades is presented. The flowpath lines are also parameterized by B-spline function and aggregated in the design system of blades. The design optimization with evolutionary algorithm is performed with constraints of fan pressure ratio, OGV exit swirl angle and nozzle exit properties. The inlet conditions for the turbo-machinery CFD (Computational Fluid Dynamics) domain and the design goal of the fan stage are driven by a propulsion airframe integration (PAI) model that uses a 3-D unstructured RANS (Reynolds Average Navier Stokes) solver and actuator disk model. The expected power saving of the BLI propulsor is quantified via PAI analysis and the resulting preliminary design of the fan stages is compared with a clean-inlet flow propulsor.

Turbo-machinery↗

High-loading low-speed fan study. 4: Data and performance with redesign stator and including a rotor tip casing treatment

A single stage fan with a rotor tip speed of 1000 ft/sec(304.8 m/sec) and a hub-to-tip ratio of 0.392 was retested with a redesigned stator. Tests were conducted with uniform inlet, tip-radial, hub-radial, and circumferential inlet distortions. With uniform inlet flow, stall margin was improved 12 percentage points above that with the original stator. The fan demonstrated an efficiency of 0.883 and a stall margin of 15 percent at a pressure ratio of 1.488 and a specific flow of 41.17 lb/sec/sq ft. Tests were also made with a redesigned casing treatment consisting of skewed slots over the rotor blade tips. This casing treatment gave a 7 percentage point improvement in stall margin when tested with tip radial distortion (when the rotor tip initiated stall). Noise measurements at the fan inlet and exit indicate no effect from closing the stator 10 degrees, nor were there measurable effects from adding skewed slots over the blade tips.

Harley, K. G.↗

NASA Glenn's Single-Stage Axial Compressor Facility Upgraded

NASA Glenn Research Center's Single-Stage Axial Compressor Facility was upgraded in fiscal year 2003 to expand and improve its research capabilities for testing high-speed fans and compressors. The old 3000-hp drive motor and gearbox were removed and replaced with a refurbished 7000-hp drive motor and gearbox, with a maximum output speed of 21,240 rpm. The higher horsepower rating permits testing of fans and compressors with higher pressure ratio or higher flow. A new inline torquemeter was installed to provide an alternate measurement of fan and compressor efficiency, along with the standard pressure and temperature measurements. A refurbished compressor bearing housing was also installed with bidirectional rotation capability, so that a variety of existing hardware could be tested. Four new lubrication modules with backup capability were installed for the motor, gearbox, torquemeter, and compressor bearing housing, so that in case the primary pump fails, the backup will prevent damage to the rotating hardware. The combustion air supply line for the facility inlet air system was activated to provide dry air for repeatable inlet conditions. New flow conditioning hardware was installed in the facility inlet plenum tank, which greatly reduced the inlet turbulence. The new inlet can also be easily modified to accommodate 20- or 22-in.-diameter fans and compressors, so a variety of existing hardware from other facilities (such as Glenn's 9- by 15-Foot Low-Speed Wind Tunnel) can be tested in the Single-Stage Axial Compressor Facility. An exhaust line was also installed to provide bleed capability to remove the inlet boundary layer. To improve the operation and control of the facility, a new programmable logic controller (PLC) was installed to upgrade from hardwired relay logic to software logic. The PLC also enabled the usage of human-machine interface software to allow for easier operation of the facility and easier reconfiguration of the facility controls when necessary. Finally, a new health-monitoring system was installed to measure shaft speed, shaft movement, and machine vibration on all of the rotating equipment. The system also provides automatic alarms and shutdown of the equipment when required. An integrated systems test for checkout of the facility was completed on June 17, 2003. Research testing resumed on June 30 with data obtained in support of the Ultra-Efficient Engine Technology Project's Compressor Casing Treatment Project.

Brokopp, Richard A.↗