Search NASASearch

SEARCH · Search NASA

Results for “fast detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Neural posterior unfolding

Differential cross section measurements are the currency of scientific exchange in particle and nuclear physics. A key challenge for these analyses is the correction for detector distortions, known as deconvolution or unfolding. Binned unfolding of cross section measurements traditionally rely on the regularized inversion of the response matrix that represents the detector response, mapping pre-detector (`particle level') observables to post-detector (`detector level') observables. In this paper we introduce Neural Posterior Unfolding, a modern, Bayesian approach that leverages normalizing flows for unfolding. By using normalizing flows for neural posterior estimation, NPU offers several key advantages including implicit regularization through the neural network architecture, fast amortized inference that eliminates the need for repeated retraining, and direct access to the full uncertainty in the unfolded result. In addition to introducing NPU, we implement a classical Bayesian unfolding method called Fully Bayesian Unfolding (FBU) in modern Python so it can also be studied. These tools are validated on simple Gaussian examples and then tested on simulated jet substructure examples from the Large Hadron Collider (LHC). We find that the Bayesian methods are effective and worth additional development to be analysis ready for cross section measurements at the LHC and beyond.

Analysis and statistical methods

Bayesian Exploration and Surrogate Emulation of Nonlinear Beam-Response Geometry in the LBNF Beamline

Next-generation long-baseline neutrino experiments aim to achieve multi-MW proton beam power while reducing accelerator-induced systematic uncertainties. At Fermilab, the LBNF beamline is designed for 1.2 MW operation with PIP-II and is upgradeable to 2.4 MW. DUNE will probe the three-flavor neutrino paradigm and search for CP violation, requiring precise neutrino-flux normalization and improved control of accelerator-related uncertainties. Within the LBNF beamline, the System for On-Axis Neutrino Detection (SAND) will constrain flux uncertainties using precision near-detector measurements, while the Muon Monitor System (MuMS) will provide beamline diagnostics sensitive to the proton beam, target, and horn configuration. However, the pion phase space relevant for DUNE depends simultaneously on many correlated parameters, including beam centroid, beam width, horn current and alignment, target position, optics shifts, and radiation-induced changes. Consequently, MuMS observables exhibit nonlinear and coupled responses that are difficult to characterize using traditional one-parameter scans. To address this challenge, we are developing a Bayesian Exploration framework coupled to physics-informed surrogate emulators trained on Geant4 beamline simulations. Gaussian-process emulators provide both fast predictions and uncertainty estimates, enabling adaptive selection of new simulation points in beam-parameter space. As an initial demonstration, we construct surrogate emulators for MuMS response observables using a verified simulation campaign spanning proton-beam steering conditions. The emulators reproduce the simulated dependence of MuMS centroid and gradient observables while providing predictive uncertainties, and serve as the foundation for future multidimensional exploration including beam width, horn current, and additional beamline parameters. This work establishes a framework for uncertainty-aware beam monitoring, adaptive simulation campaigns, and rapid beam-response inference for future DUNE operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA

Nuclear recoil detection with color centers in bulk lithium fluoride

We present initial results on the detection of nuclear recoils in lithium fluoride (LiF) through the fluorescence of color centers created by particle interactions in the crystal lattice. Using light-sheet fluorescence microscopy, we image nuclear recoil tracks from both fast and thermal neutron interactions deep within a cubic-centimeter-scale sample. Automated three-dimensional feature extraction based on machine-learning tools enables the identification and classification of individual events. We observe that the fluorescence response of LiF to gamma irradiation is strongly suppressed, by a factor of 30–50 compared to neutron exposure, demonstrating intrinsic insensitivity to electromagnetic backgrounds. The observed and simulated event characteristics are consistent, including their number, size, and topology. These results establish the feasibility of LiF as a scalable detection medium for rare nuclear-recoil events and constitute a first step toward 10–1000 g scale detectors with single-event sensitivity for applications in reactor-neutrino detection, neutron spectroscopy, and dark matter searches.

Aroujo, G R [University of Zurich]

Radiation-Hard Smart-Pixel Detector ASIC ReadOut with Digital AI in 28nm

Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout channels. With event rates as high as 40 MHz, these detectors will generate petabytes of data per second. To enable discovery within strict bandwidth and latency constraints, future trackers must be capable of fast, power efficient, and radiation hard data-reduction at the source. This effort is pursuing the co-design development of high-performance readout smart pixel ASICs for a future Phase III High Luminosity upgrade of the Large Hadron Collider. A 1.6mm2 ASIC prototype was designed by Fermilab in CMOS 28 nm bulk process and submitted for manufacturing in February 2024. It leverages the analog front-end pixel design of a previous prototype fabricated and tested in 2023, which achieved a simulated detection level of ~400e- with 30fF input capacitance. The ROIC consists of two matrices of 16×16 smart pixels, each 25×25 μm2 in size. Each smart pixel contains a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. There is digital space for the integration of our fully combinatorial AI that performs momentum classification at the bunch crossing rate. The total power consumption is ∼6μW per pixel, which corresponds to ~1mW/cm2. The ASIC incorporates programmable front-end charge injection circuitry to generate pixel cluster charges during characterization. The cluster profile will be generated to duplicate hit characteristics of various momentum (pT). We will present early results from chip testing.

Parpillon, Benjamin

A study of the temporal and spectral characteristics of gamma ray bursts

Gamma-ray burst data obtained from the ISEE-3 Gamma Ray Burst Spectrometer and the Solar Maximum Mission's Hard X-ray Burst Spectrometer (HXRBS) were analyzed to yield information on burst temporal and spectral characteristics. A Monte Carlo approach was used to simulate the HXRBS response to candidate spectral models. At energies above about 100 keV, the spectra are well fit by exponential forms. At lower energies, 30 keV to 60 keV, depressions below the model continua are apparent in some bursts. The depressions are not instrumental or data-reduction artifacts. The event selection criterion of the ISEE-3 experiment is based on the time to accumulate a present number of photons rather than the photon count per unit time and is consequently independent of event duration for a given burst intensity, unlike most conventional systems. As a result, a significantly greater percentage of fast, narrow events have been detected. The ratio of count rates from two ISEE-3 detectors indicates that bursts with durations or approx. one second have much softer spectra than longer bursts.

Norris, J.

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape

Evolution of a localized Langmuir packet in the solar wind and on auroral field lines

Langmuir emissions in space are reported to be clumpy and intermittent. The high-frequency wave power appears concentrated in spatial packets, whether amidst the solar wind or on auroral field lines. Due to the plasma motion relative to the spacecraft, determining the source for the wave free energy in the three-dimensional electron distribution function has always been difficult, since the unstable features pass by the detector in presumably too short time to be measured. The range of unstable phase velocities and growth rates have generally been estimated rather than determined by unequivocal measurements. The analysis of wave-particle interactions in a space environment has taken recently a new turn with the development of wave correlators on board rockets and satellites. Such instruments seek to identify correlations between the phase of the wave-field and the fluxes of energetic particles. The data interpretation is complex, however, it must be backed by a detailed theoretical understanding of the wave-particle interaction, including the phase relation for inhomogeneous packets. To this end Langmuir packets interacting with fast electrons can be studied in the appropriate regime by means of particle-in-cell simulations, provided that one succeeds in reducing the level of the fluctuations, enhancing the signal-to-noise ratio, and incorporating the appropriate boundary conditions. The first results of such simulations are presented here as a test and expansion of previous analysis.

Roth, I.

NASA Tech Briefs, March 2005

Topics covered include: Scheme for Entering Binary Data Into a Quantum Computer; Encryption for Remote Control via Internet or Intranet; Coupled Receiver/Decoders for Low-Rate Turbo Codes; Processing GPS Occultation Data To Characterize Atmosphere; Displacing Unpredictable Nulls in Antenna Radiation Patterns; Integrated Pointing and Signal Detector for Optical Receiver; Adaptive Thresholding and Parameter Estimation for PPM; Data-Driven Software Framework for Web-Based ISS Telescience; Software for Secondary-School Learning About Robotics; Fuzzy Logic Engine; Telephone-Directory Program; Simulating a Direction-Finder Search for an ELT; Formulating Precursors for Coating Metals and Ceramics; Making Macroscopic Assemblies of Aligned Carbon Nanotubes; Ball Bearings Equipped for In Situ Lubrication on Demand; Synthetic Bursae for Robots; Robot Forearm and Dexterous Hand; Making a Metal-Lined Composite-Overwrapped Pressure Vessel; Ex Vivo Growth of Bioengineered Ligaments and Other Tissues; Stroboscopic Goggles for Reduction of Motion Sickness; Articulating Support for Horizontal Resistive Exercise; Modified Penning-Malmberg Trap for Storing Antiprotons; Tumbleweed Rovers; Two-Photon Fluorescence Microscope for Microgravity Research; Biased Randomized Algorithm for Fast Model-Based Diagnosis; Fast Algorithms for Model-Based Diagnosis; Simulations of Evaporating Multicomponent Fuel Drops; Formation Flying of Tethered and Nontethered Spacecraft; and Two Methods for Efficient Solution of the Hitting- Set Problem.

Source record

Laboratory scaled simulation of lidar cloud sounding experiments

The results of lidar measurements carried out on laboratory scale models of clouds are presented. Measurements on laboratory scale models are important since one has the knowledge of the relevant parameters of the diffusing medium, such as: scattering and absorption coefficients, phase function, homogeneity, shape, etc. Knowledge of these parameters enables one to use the results to test the reliability of theoretical and numerical investigations. To obtain a laboratory scaled model of a lidar system sounding a cloud, it is necessary to scale down all the geometrical quantities by the same factor to reduce distances of the order of kilometers to the order of meters, keeping the size and the optical depth of the diffusers unchanged. If a time resolution of the order of nanoseconds is necessary for a lidar sounding actual clouds, the corresponding time resolution for the laboratory model should be of the order of picoseconds. It is possible to obtain this resolution by using picosecond laser systems and fast electrooptical detectors like the streak camera. The results of the laboratory measurements showed that the multiple scattering effect strongly depends on the size of the diffusers, as well as on the concentration. The experimental results were compared with the numerical results of a Monte Carlo code. A generally good agreement was obtained.

Zaccanti, G.

Scientific Objectives of the Mars Surveyor 2001 Gamma-Ray Spectrometer

The Gamma-Ray Spectrometer (GRS) is one of the instruments on the Mars Surveyor 2001 Orbiter, which is part of NASA's Mars-Surveyor program. The GRS is really an instrument suite consisting of the GRS, a neutron spectrometer (NS), and a high-energy neutron detector (FIEND). Each of these instruments/sensors are remotely mounted at different locations on the spacecraft and connect to a central electronics box. The GRS will achieve global mapping of the elemental composition of the surface and the abundance of hydrogen in the shallow subsurface. It is an updated design using the same technology as the lost Mars Observer mission. The Martian surface is continuously bombarded by cosmic ray particles; their interactions with the constituents of the soil produces nuclear reaction cascades with fast neutrons being the main secondaries. Those neutrons interact in turn with the nuclei of the elements that make up the soil and they eventually get slowed to thermal energies. In this process they leave the nuclei in an excited state that decays via the emission of characteristic gamma rays. All these processes are precisely known and have been simulated by means of numerical models. Thus, remote gamma-ray spectroscopy is a useful method for quantitatively measuring the geochemical composition of the surface down to a few tens of g/sq cm. Additional information is contained in original extended abstract.

Boynton, W. V.

Digital implementation of the TF30-P-3 turbofan engine control

The standard hydromechanical control modes for TF30-P-3 engine were implemented on a digital process control computer. Programming methods are described, and a method is presented to solve stability problems associated with fast response dynamic loops contained within the exhaust nozzle control. A modification of the exhaust nozzle control to provide for either velocity or position servoactuation systems is discussed. Transient response of the digital control was evaluated by tests on a real time hybrid simulation of the TF30-P-3 engine. It is shown that the deadtime produced by the calculation time delay between sampling and final output is more significant to transient response than the effects associated with sampling rate alone. For the main fuel control, extended update and calculation times resulted in a lengthened transient response to throttle bursts from idle to intermediate with an increase in high pressure compressor stall margin. Extremely long update intervals of 250 msec could be achieved without instability. Update extension for the exhaust nozzle control resulted in a delayed response of the afterburner light-off detector and exhaust nozzle overshoot with resulting fan oversuppression. Long update times of 150 msec caused failure of the control due to a false indication by the blowout detector.

Cwynar, D. S.

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi

Real-Time Xenon Sensor Analysis Report

Radiotracer release experiments were performed at the Nevada National Security Site in October 2022. The overall experiment was called the RElease ACTivity (REACT) experiment. Twenty-two real-time xenon sensors were deployed for each of four releases. Initial, quick-look analysis results were reported in December 2022. This report reviews the more comprehensive offline analysis effort that was conducted during the remainder of fiscal year 2023 by the Dynamic Networks venture. Improved energy stabilization routines were implemented along with an improved background subtraction routine compared to the original quicklook calculations. The relative detection efficiencies of all real-time sensors were examined. Finally, simulated detector response functions were coupled to two different meteorological models using the measured conditions for the final release (REACT-04) to compare simulated detections with measurements. While there is some agreement between the models and measured data on the detection locations and timing, there is less agreement on the magnitude of those detections. Future sensor and meteorological modeling work will be needed to improve the agreement and to examine the additional releases (REACT-01 through REACT-03).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

MAS-CCD: New technique for measuring low-level charge content based on the multiple amplifier architecture

Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device (MAS-CCD) emerges as a promising technology for future scientific instruments. A critical parameter affecting the performance of these devices is spurious charge, produced by the clocking of the gates. Its measurement is typically challenging with existing methods. In practice, the optimization of this parameter often relies on empirical procedures that require significant time and careful consideration of the trade-off with full-well capacity. In this work, we present a new technique to estimate spurious charge based on covariance analysis of the output amplifiers of the MAS-CCD, which measures the same charge packet in different amplifiers at different times. The method enables fast and precise measurements of spurious charge under operating conditions where conventional approaches are difficult to apply. We develop the theoretical framework of the method and validate the model through simulations. The results demonstrate the feasibility of this approach and suggest that it could serve as a basis for reliable large-scale characterization of sensor performance.

Gamero, Miqueas E. [Buenos Aires, CONICET; Fermila

Intelligent Experiments through Real-Time AI: Fast Data Processing and Autonomous Detector Control for High-Energy Nuclear Experiments

The aim of this project is to develop software and hardware for fast real-time data processing and autonomous detector control and calibration for the sPHENIX and the future EIC experiments. Below summarizes Georgia Tech team efforts in the past year: 1. We developed a real-time clustering algorithm and FPGA-based pipeline architecture for processing fired pixel data from ALPIDE sensors in sPHENIX experiments. Our Columnar Clustering Co-Design introduces a hardware-aware, stream-friendly approach that segments pixel data by column pairs using a Column Pair Clustering (CPC) strategy, followed by Cluster Stitching to merge adjacent subclusters. Implemented in Vitis HLS, the pipeline comprises five stages—read-in, subclustering, stitching, analysis, and write-out—connected by tagged HLS streams with custom end-of-event signaling for robust synchronization. We designed a pipelined dataflow model optimized for throughput, low latency, and minimal buffering, enabling scalable clustering across events of arbitrary size. Our system maintains spatial precision via center-of-mass and shape key extraction and efficiently handles edge cases such as fragmented or nested clusters. Compared against DBSCAN in both software and hardware, our approach demonstrates competitive performance under FPGA constraints. 2. We also conducted a comprehensive algorithm-to-hardware co-design of connected component analysis tailored for sPHENIX experiments, focusing on real-time, low-latency processing using FPGAs and High-Level Synthesis (HLS). Starting from a Python-based particle tracking pipeline, the team translated the core logic—graph traversal via DFS and Union-Find—into an HLS-compatible C++ model, replacing dynamic memory and recursion with static arrays and pipelined control flow. The final design includes a fully streamed and dataflow-compatible Union-Find kernel optimized across five iterations, incorporating loop pipelining, array partitioning, AXI/FIFO interface tuning, and function flattening. Experimental results show up to 14.8× speedup over the CPU baseline, reducing per-graph latency to 1.58 μs and demonstrating strong resource efficiency with only ~7k LUTs and zero BRAM usage. The design maintains functional correctness against the Python reference using a Python-based C-simulation framework and Mean Squared Error metrics. This work validates the potential of HLS-driven FPGA designs for edge-level HEP data acquisition, laying a scalable foundation for future integration with real-time detector pipelines and multi-graph processing systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION