Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast solar wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental observations of detached bow shock formation in the interaction of a laser-produced plasma with a magnetized obstacle

The magnetic field produced by planets with active dynamos, like the Earth, can exert sufficient pressure to oppose supersonic stellar wind plasmas, leading to the formation of a standing bow shock upstream of the magnetopause, or pressure-balance surface. Scaled laboratory experiments studying the interaction of an inflowing solar wind analog with a strong, external magnetic field are a promising new way to study magnetospheric physics and to complement existing models, although reaching regimes favorable for magnetized shock formation is experimentally challenging. This paper presents experimental evidence of the formation of a magnetized bow shock in the interaction of a supersonic, super-Alfvenic plasma with a strongly magnetized obstacle at the OMEGA laser facility. The solar wind analog is generated by the collision and subsequent expansion of two counter- propagating, laser-driven plasma plumes. The magnetized obstacle is a thin wire, driven with strong electrical currents. Hydrodynamic simulations using the FLASH code predict that the colliding plasma source meets the criteria for bow shock formation. Spatially resolved, optical Thomson scat- tering measures the electron number density, and optical emission lines provide a measurement of the plasma temperature, from which we infer the presence of a fast magnetosonic shock far upstream of the obstacle. Proton images provide a measure of large-scale features in the magnetic field topology, and reconstructed path-integrated magnetic field maps from these images suggest the formation of a bow shock upstream of the wire and as a transient magnetopause. We compare features in the reconstructed fields to two-dimensional MHD simulations of the system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microphysically modified magnetosonic modes in collisionless, high-β plasmas

With the support of hybrid-kinetic simulations and analytic theory, we describe the nonlinear behaviour of long-wavelength non-propagating (NP) modes and fast magnetosonic waves in high-β collisionless plasmas, with particular attention to their excitation of and reaction to kinetic micro-instabilities. The perpendicularly pressure balanced polarization of NP modes produces an excess of perpendicular pressure over parallel pressure in regions where the plasma β is increased. For mode amplitudes |δB/B 0 |≳0.3, this excess excites the mirror instability. Particle scattering off these micro-scale mirrors frustrates the nonlinear saturation of transit-time damping, ensuring that large-amplitude NP modes continue their decay to small amplitudes. At asymptotically large wavelengths, we predict that the mirror-induced scattering will be large enough to interrupt transit-time damping entirely, isotropizing the pressure perturbations and morphing the collisionless NP mode into the magnetohydrodynamic (MHD) entropy mode. In fast waves, a fluctuating pressure anisotropy drives both mirror and firehose instabilities when the wave amplitude satisfies |δB/B 0 |≳2β -1 . The induced particle scattering leads to delayed shock formation and MHD-like wave dynamics. Taken alongside prior work on self-interrupting Alfvén waves and self-sustaining ion-acoustic waves, our results establish a foundation for new theories of electromagnetic turbulence in low-collisionality, high-β plasmas such as the intracluster medium, radiatively inefficient accretion flows and the near-Earth solar wind.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A drift kinetic model for the expander region of a magnetic mirror

Here, we present a drift kinetic model for the free expansion of a thermal plasma out of a magnetic nozzle. This problem relates to plasma space propulsion systems, natural environments such as the solar wind, and end losses from the expander region of mirror magnetically confined fusion concepts such as the gas dynamic trap. The model incorporates trapped and passing orbit types encountered in the mirror expander geometry and maps to an upstream thermal distribution. This boundary condition and quasineutrality require the generation of an ambipolar potential drop of ~5T e /e, forming a thermal barrier for the electrons. The model for the electron and ion velocity distributions and fluid moments is confirmed with data from a fully kinetic simulation. Finally, the model is extended to account for a population of fast sloshing ions arising from neutral beam heating within a magnetic mirror, again resulting in good agreement with a corresponding kinetic simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seasonal Performance Characterization of a Gen3 Particle-Based Concentrating Solar Plant With a Spatially Resolved Transient Thermal Storage Model

Particle-based Gen3 Concentrating Solar Power (CSP) can be paired with high-temperature power cycles (>700 °C) and can have built-in long duration (≥10 hours) thermal energy storage if the working particles are stored properly in thermal energy storage bins. Although high-temperature and long-duration thermal energy storage can mitigate daily intermittencies in solar irradiation, seasonal variability in local meteorological conditions can still have a significant impact on the overall performance of CSP systems. Aside from daily cloud coverage affecting incident solar radiation, wind speed and ambient temperature are also significant variables regarding system heat attenuation, component efficiency, and overall solar conversion efficiency. In this work, we present simulation results for a Gen3 CSP prototype system in operation over four weeks throughout the year in Albuquerque, NM. The meteorological conditions are taken directly from the TMY3 data at the Albuquerque International Sunport, where the hourly Direct Normal Irradiation (DNI), wind speed, and ambient temperature are of particular interest. An investigation of the sensitivity of individual components like storage and ducting to the local meteorological conditions is provided and extended to the overall performance of the CSP system. The results from this study show that the particle inlet temperature at the particle-to-sCO2 heat exchanger can change as fast as 30 °C/min under standard operation in a passive mode.

Plewe, Kaden (ORCID:0000000286826879)↗

Nature of transonic sub-Alfvénic turbulence and density fluctuations in the near-Sun solar wind

Context. Recent Parker Solar Probe (PSP) measurements have revealed that solar wind (SW) turbulence transits from a subsonic to a transonic regime near the Sun, while remaining sub-Alfvénic. These observations call for a revision of the existing SW models, where turbulence is considered to be both subsonic and sub-Alfvénic. Aims. In this work, we introduce a new magnetohydrodynamic (MHD) model of transonic sub-Alfvénic turbulence (TsAT). Methods. We used 3D MHD simulations initialized with parameters measured by PSP to investigate the properties of the new near-Sun SW transonic turbulent regime. We then derived a reduced set of MHD equations in the transonic sub-Alfvénic limit to interpret our numerical results. Results. Our TsAT model shows that turbulence is effectively nearly incompressible (NI) and has a 2D + slab (quasi-2D) geometry not only in the subsonic limit, but also in the transonic regime, as long as it remains sub-Alfvénic, a condition essentially enforced everywhere in the heliosphere by the strong local magnetic field. These predictions are consistent with 3D MHD simulations, showing that transonic turbulence is dominated by low-frequency quasi-2D incompressible structures, while compressible fluctuations are a minor component corresponding to low-frequency slow modes and high-frequency fast modes. Conclusions. Our new TsAT model extends existing NI theories of turbulence, and is potentially relevant for the theoretical and numerical modeling of space and astrophysical plasmas, including the near-Sun SW, the solar corona, and the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Assessment of Deploying Advanced Pumped Storage Hydropower Technology in U.S. Electricity Markets

Pumped storage hydropower (PSH) is a type of hydropower technology where energy can be stored and generated by moving water between two reservoirs of differing elevations. In addition to providing 97% of the total utility-scale hydropower storage in the United States, PSH plants have operational characteristics - such as high ramp rates and the ability to provide reserves - that contribute to greater flexibility and reliability of the power grid. New PSH technologies can provide additional flexibility beyond existing, fixed-speed units. With the emergence of high levels of variable renewable energy resources (e.g., wind and solar), energy storage is expected to be crucial to the reliability and reliance of the power grid in a low-carbon future. At diurnal and longer durations, PSH plants have some of the lowest costs per unit of energy, have been proven to be reliable and efficient, are not cycle-limited, and typically have long lives, often exceeding 50 years. The work presented here focuses on a new generation of PSH: ternary PSH and quaternary PSH (together referred to as T/Q-PSH). Given recent experience in Europe, grid operators in the United States and elsewhere are increasingly focusing their attention on T/Q-PSH as a proven, financeable technology that can offer utility-scale, long-duration, fast-acting energy storage capabilities and grid services. T/Q-PSH differs from conventional PSH in that it can provide fast-response ancillary services during both generating and pumping operations. This capability together with fast mode switching times are key attributes that make T/Q-PSH technologies attractive for managing and stabilizing electricity systems with high amounts of variable renewable energy.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Improvements in Reflected Target Non-intrusive Assessment (ReTNA)

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. In 2022, NREL presented a new indoor optical measurement system to measure fully assembled heliostats during development and on the assembly line for quality assurance purposes, which has undergone significant development in the last year, including the installation of a new, larger laboratory setup. This system, called ReTNA (Reflected Target Non-intrusive Assessment), uses a printed pattern as a deflectometry target. Using printed pattern features as deflectometry targets instead of fringes allows the software to measure the surface slope in two dimensions, eliminating the need to for changing, projected targets. In the last year, NREL's ReTNA tool has been adapted to use a tall, thin target, that only spans one dimension of the mirror, and a camera moving on an automatic track system. We will present these new developments, including the new setup, target patterns, software methodology for fast, automatic optical analysis, and important lessons learned throughout the process. ReTNA results will be compared to established tools, to establish the uncertainty of this new method. ReTNA leverages recent improvements in computer vision and photogrammetry to remove as much careful calibration from the setup process as possible, making the tool low cost, simple, and portable. While it will not achieve the resolution of a fringe deflectometry system, its advantages make it well suited for CSP evaluation, and allow it to fill a different industry need.

concentrating solar power↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Density and Magnetic Field Asymmetric Kelvin‐Helmholtz Instability

Abstract The Kelvin‐Helmholtz (KH) instability can transport mass, momentum, magnetic flux, and energy between the magnetosheath and magnetosphere, which plays an important role in the solar‐wind‐magnetosphere coupling process for different planets. Meanwhile, strong density and magnetic field asymmetry are often present between the magnetosheath (MSH) and magnetosphere (MSP), which could affect the transport processes driven by the KH instability. Our magnetohydrodynamics simulation shows that the KH growth rate is insensitive to the density ratio between the MSP and the MSH in the compressible regime, which is different than the prediction from linear incompressible theory. When the interplanetary magnetic field (IMF) is parallel to the planet's magnetic field, the nonlinear KH instability can drive a double mid‐latitude reconnection (DMLR) process. The total double reconnected flux depends on the KH wavelength and the strength of the lower magnetic field. When the IMF is anti‐parallel to the planet's magnetic field, the nonlinear interaction between magnetic reconnection and the KH instability leads to fast reconnection (i.e., close to Petschek reconnection even without including kinetic physics). However, the peak value of the reconnection rate still follows the asymmetric reconnection scaling laws. We also demonstrate that the DMLR process driven by the KH instability mixes the plasma from different regions and consequently generates different types of velocity distribution functions. We show that the counter‐streaming beams can be simply generated via the change of the flux tube connection and do not require parallel electric fields.

Astronomy & Astrophysics↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Progress of Nanotechnology for Lithium-Sulfur Batteries

Lithium-Sulfur (Li-S) battery has been proposed and investigated since the 1960s as an effective energy storage device via reversible electrochemical reactions. As the fast development and commercialization of Li-ion battery (LIB) technology kept moving forward, no breakthroughs have been attained to solve critical technical issues facing Li-S batteries during the following decades. In the year 2000s, Li-S batteries reattracted significant interests in the research field owing to their low-cost advantages, high theoretical specific energy of 2600 Wh kg -1 , which is at least 3 times higher than the current LIB technology. The low-cost and high abundance of sulfur (i.e., the cathode active material), make Li-S batteries more appealing than LIBs given the fact that the latter use critical materials such as cobalt and nickel in the manufacturing of the cathodes. Moreover, the high-energy and low-cost features make the Li-S battery a promising energy storage technology in practical applications such as portable devices, electric vehicles, and grid storage when coupled with the harvesting of solar or wind renewable energies. For example, since 2007, SION Power Corporation (Tucson, USA) and Oxis Energy (UK) made progress towards the commercialization of Li-S batteries with products showing specific energies over 350 Wh kg -1 for powering electric vehicles. To be on a par with the current LIB technology, the ultimate goal of achieving 500 Wh kg -1 for Li-S battery will make it more competitive for widespread commercialization.

Li, Mengya↗

Computational Approaches for Clean Energy Materials

Currently, 80% of the global final energy consumption occurs in form of fuels and only 20% as electricity. On the other hand, renewable energy additions come almost exclusively in the form of electricity (dominantly photovoltaics and wind). Thus, a successful energy transition will require enormous growth in renewables, sufficient to convert excess electricity into fuels, as well as the development of non-electricity based solar fuel technologies. As much as photovoltaic capacities have grown over the past 20 years, it is far from clear that current technologies and materials are up to the task to grow from here by yet another factor 100 until 2050. Therefore, sustained research efforts on emerging inorganic semiconductors for solar electricity and fuels are essential for facing the double challenge of climate change and energy security. Computational materials science can make important contributions, guiding and supporting research activities through both materials search and discovery and through detailed studies that help to develop a mechanistic understanding of materials performance and bottlenecks. This presentation will highlight three recent computational projects with relevance for photovoltaics and solar fuels (1) Defect graph neural networks (dGNN) for materials discovery in solar thermochemical hydrogen (STCH) [1]. The dGNN approach facilitates broad and fast materials screening for defect properties. (2) Modeling highly off-stoichiometric systems by evaluating the free energy of defect interaction [2]. This approach allows quantitative prediction of H2 production in complex STCH oxides. (3) First-principles atomic structure prediction for interfaces [3]. This work showed how an atomically thin CdCl2 interlayer phase enables in principle ideal electron transport across the incommensurate SnO2/CdTe interface. [1] M.D. Witman, A. Goyal, T. Ogitsu, A.H. McDaniel, S. Lany, Nat. Comput. Sci. (2023). https://doi.org/10.1038/s43588-023-00495-2. [2] A. Goyal, M.D. Sanders, R.P. O'Hayre, S. Lany, PRX Energy 3, 013008 (2024). https://doi.org/10.1103/PRXEnergy.3.013008. [3] A. Sharan, M. Nardone, D. Krasikov, N. Singh, S. Lany, Appl. Phys. Rev. 9, 041411 (2022). https://doi.org/10.1063/5.0104008.

density functional theory↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗