Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault classification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Unified Taxonomy for HVAC System Faults

Detecting and diagnosing HVAC faults is critical for maintaining building operation performance, reducing energy waste, and ensuring indoor comfort. An increasing deployment of commercial fault detection and diagnostics (FDD) software tools in commercial buildings in the past decade has significantly increased buildings’ operational reliability and reduced energy consumption. A massive amount of data has been generated by the FDD software tools. However, efficiently utilizing FDD data for ‘big data’ analytics, algorithm improvement, and other data-driven applications is challenging because the format and naming conventions of those data are very customized, unstructured, and hard to interpret. This paper presents the development of a unified taxonomy for HVAC faults. A taxonomy is an orderly classification of HVAC faults according to their characteristics and causal relations. The taxonomy includes fault categorization, physical hierarchy, fault library, relation model, and naming/tagging scheme. The taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model to reveal the root causes of faults in HVAC systems. A structured and standardized vocabulary library is developed to increase data representability and interpretability. The developed fault taxonomy can be used for HVAC system ‘big data’ analytics such as HVAC system fault prevalence analysis or the development of an HVAC FDD software standard. A common type of HVAC equipment-packaged rooftop unit (RTU) is used as an example to demonstrate the application of the developed fault taxonomy. Two RTU FDD software tools are used to show that after mapping FDD data according to the taxonomy, the meta-analysis of the multiple FDD reports is possible and efficient.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Convolution Neural Network for Fault Identification in Distribution Feeder with High Penetration Solar PV

Identification and zonal classification of the faults is a decisive factor in the relay’s decision to trip or not. Different types of fault like three-phase, line-to-line-to-ground and single-line-to-ground can occur at various locations in the feeder. These faults are seen as the variation in the instantaneous values of three-phase voltages and currents, i.e., waveforms, that are measured at the relay location. The objective of this work is to develop a machine learning model that can identify a fault and classify it to various protection zones based on measured waveforms. In this work, a data-driven relay based on Convolutional Neural Network (CNN) is proposed for fault identification in distribution feeders with high penetration solar PV. The proposed CNN model takes local current and voltage waveforms as input and classify it into fault, no-fault or a capacitor switching. Further, the CNN also attempts to identify fault zones based on the images of waveforms. The overall testing accuracy of the trained model exceeds 95%.

Ramesh, Meghana↗

Characteristics and selection of near-fault simulated earthquake ground motions for nonlinear analysis of buildings

Earthquake-induced ground shaking near rupturing faults is highly sensitive to the rupture characteristics, seismic wave propagation patterns and site conditions, and field recordings of near-fault shaking are relatively sparse. These challenges complicate the assessment of the seismic performance of near-fault structures. A common approach to representing near-fault ground motion in engineering analysis is to explicitly consider and select records with strong directivity pulses (pulse records). We use three-dimensional high-resolution physics-based earthquake simulations to test this approach in the context of scenario-based ground motion record selection, and to study the important characteristics of near-fault ground shaking. We highlight the deficiencies associated with classifying near-fault simulated records as “pulse” or “non-pulse,” based on the presence of a single dominating pulse in the velocity time history. We show that this approach is inadequate for characterizing near-fault shaking on soft soils which can be dominated by both forward rupture directivity and basin amplification effects. We conduct ground motion selection experiments for the analysis of near-fault structures with and without explicit classification of the pulse features in the records, and evaluate the bias in the predicted structural demands. We find that the maximum interstory drift demands on building structures imposed by unscaled site-specific simulated ground motion records selected based on relevant spectral shape features are not sensitive to the classification of records as pulse/non-pulse. Therefore, with regard to predicting the maximum interstory drifts in near-fault buildings, we do not find justification for the binary pulse classification of near-fault records.

42 ENGINEERING↗

Rotor blade imbalance fault detection for variable-speed marine current turbines via generator power signal analysis

Marine hydrokinetic (MHK) turbines extract renewable energy from oceanic environments. However, due to the harsh conditions that these turbines operate in, system performance naturally degrades over time. Thus, ensuring efficient condition-based maintenance is imperative towards guaranteeing reliable operation and reduced costs for marine hydrokinetic power. This work proposes a novel framework aimed at identifying and classifying the severity of rotor blade pitch imbalance faults experienced by marine current turbines (MCTs). In the framework, a Continuous Morlet Wavelet Transform (CMWT) is first utilized to acquire the wavelet coefficients encompassed within the 1P frequency range of the turbine's rotor shaft. From these coefficients, several statistical indices are tabulated into a six-dimensional feature space. Next, Principle Component Analysis (PCA) is employed on the resulting feature space for dimensionality reduction, and then the application of a K-Nearest Neighbor (KNN) machine learning algorithm is utilized for fault detection and severity classification. The effectiveness of the proposed framework is validated using a high-fidelity MCT numerical simulation platform, where results demonstrate that the presence of a pitch imbalance fault can be accurately detected 100% of the time and correctly classified based upon severity more than 97% of the time.

42 ENGINEERING↗

Multivariate Time Series Intermittent Fault Detectionin Controller Area Network CAN

Fault detection in Controller Area Network (CAN) systems is crucial for ensuring the reliability and safety of automotive and industrial applications. This study investigates and compares the effectiveness of time series classification models for supervised fault detection in CAN data. This repository contains the code and data for our benchmarking experiment aimed at detecting intermittent faults in automotive Controller Area Network (CAN) data. The goal of this project is to compare various machine learning (ML) and deep learning (DL) models using different Time Series Cross-Validation (TSCV) techniques to evaluate their effectiveness in a streaming environment for fault detection.

Hespeler, Steven [Oak Ridge National Laboratory (O↗

Photovoltaic System Health-State Architecture for Data-Driven Failure Detection

The timely detection of photovoltaic (PV) system failures is important for maintaining optimal performance and lifetime reliability. A main challenge remains the lack of a unified health-state architecture for the uninterrupted monitoring and predictive performance of PV systems. To this end, existing failure detection models are strongly dependent on the availability and quality of site-specific historic data. The scope of this work is to address these fundamental challenges by presenting a health-state architecture for advanced PV system monitoring. The proposed architecture comprises of a machine learning model for PV performance modeling and accurate failure diagnosis. The predictive model is optimally trained on low amounts of on-site data using minimal features and coupled to functional routines for data quality verification, whereas the classifier is trained under an enhanced supervised learning regime. The results demonstrated high accuracies for the implemented predictive model, exhibiting normalized root mean square errors lower than 3.40% even when trained with low data shares. The classification results provided evidence that fault conditions can be detected with a sensitivity of 83.91% for synthetic power-loss events (power reduction of 5%) and of 97.99% for field-emulated failures in the test-bench PV system. Finally, this work provides insights on how to construct an accurate PV system with predictive and classification models for the timely detection of faults and uninterrupted monitoring of PV systems, regardless of historic data availability and quality. Such guidelines and insights on the development of accurate health-state architectures for PV plants can have positive implications in operation and maintenance and monitoring strategies, thus improving the system’s performance.

photovoltaics↗

LCOE reduction through proactively optimized monitoring of PV Systems (Final Technical Report)

The project demonstrates the value proposition for a high-resolution monitoring system (HRMS) with diagnostic-prognostic capability and determine its impact on LCOE. The HRMS differs from conventional monitoring systems in a number of ways. First it will include the capability to automatically measure IV curves at the string and module levels. This provides a much richer view into the DC performance of the PV system and allows classification of many typical failure and degradation modes. Second, it will incorporate software capable of quantifying power and energy losses in the field as well as define the location and mechanism of the power and energy loss. Moreover, we aimed to deliver a prognostic system that is capable of predicting certain failures before they occur and giving system operators the opportunity to more efficiently plan operations and maintenance (O&M) activity in order to lower costs and increase yield over the life of the system. The research identifies cost targets required for different monitoring stages, including at the string combiner, at the individual string, and at the module level, to lower the levelized cost of energy (LCOE). Finally, a comprehensive guide determines the value PV monitoring brings to PV field operations. The guide assists plant operators in maximizing value from existing plants and identify the trade-offs of different monitoring solutions for future plants depending on the size, location, and expected system lifetime.

14 SOLAR ENERGY↗

Fault Detection Utilizing Convolution Neural Network on Timeseries Synchrophasor Data From Phasor Measurement Units

An end-to-end supervised learning method is proposed for fault detection in the electric grid using Big Data from multiple Phasor Measurement Units (PMUs). The approach consists of preprocessing steps aimed at reducing data noise and dimensionality, followed by utilization of six classification models considered for detecting faults. Three of the models were variants of Convolutional Neural Network (CNN) architectures that consider a single type of measurement (voltage, current or frequency) at all PMUs or all types together also at all PMUs. CNN based models were compared to traditional methods of Logistic Regression (LR), Multi-layer Perceptron (MLP) and Support Vector Machine (SVM). Evaluation was conducted on two-year data measured by PMUs at 37 locations in a large electric grid. Here, the response variable for classification were extracted from the grid-wide outage event log. Experiments show that CNN-based models outperformed traditional methods on one year out-of-sample outage detection over the entire grid.

42 ENGINEERING↗

Series and parallel arc-fault circuit interrupter tests.

While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by opening the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.

Johnson, Jay Dean↗

Power System Event Classification and Localization Using a Convolutional Neural Network

Detection and timely identification of power system disturbances are essential for situation awareness and reliable electricity grid operation. Because records of actual events in the system are limited, ensemble simulation-based events are needed to provide adequate data for building event-detection models through deep learning; e.g., a convolutional neural network (CNN). An ensemble numerical simulation-based training data set have been generated through dynamic simulations performed on the Polish system with various types of faults in different locations. Such data augmentation is proven to be able to provide adequate data for deep learning. The synchronous generators’ frequency signals are used and encoded into images for developing and evaluating CNN models for classification of fault types and locations. With a time-domain stacked image set as the benchmark, two different time-series encoding approaches, i.e., wavelet decomposition-based frequency-domain stacking and polar coordinate system-based Gramian Angular Field (GAF) stacking, are also adopted to evaluate and compare the CNN model performance and applicability. The various encoding approaches are suitable for different fault types and spatial zonation. With optimized settings of the developed CNN models, the classification and localization accuracies can go beyond 84 and 91%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-Submodule Open-Circuit Fault Diagnosis for a Modular Multi-level Converter Using Artificial Intelligent-based Techniques

Modular multi-level converters (MMCs) are one of the promising topologies in recent years for medium or high voltage applications. They are considered as the next generation DC/AC converters for medium/high voltage (MV/HV) motor drive applications due to their transform-less structures, high efficiency and modularity. Reliability is one of the most important challenges in MMCs, since a large number of power switching devices are used and each of these devices can be considered as a potential failure point. It is significant to detect and locate the fault accurately and apply appropriate protections in a timely manner. This paper investigates the behavior of the failure submodules and healthy submodules and use artificial neural network (ANN) classification algorithms for singlesubmodule open-circuit fault diagnosis. The ANN algorithm is implemented in field programmable gate array (FPGA) and the ANN parameters training is completed offline in Matlab. Experimental results of the proposed fault diagnosis for a singlemodule open-circuit fault are presented in this paper.

artificial intelligent↗

Coherency-Based Detection Algorithm for Synchrophasor Cyberattacks

The wide area monitoring system (WAMS) is critical for power system situational awareness, but represents a growing cybersecurity vulnerability. Malicious adversaries may seek to compromise one or more PMUs in order to effect control decisions that unnecessarily disrupt typical grid operations. One example of a particularly pernicious attack vector is the spoofing or replaying of a fault event using one or more compromised PMUs. This work documents the development and validation of a coherency-based cyberattack detection algorithm that integrates a sliding-window singular value decomposition (SVD) with physics-based partitioning analysis to achieve accurate classification of events. Special consideration is given to discerning a sophisticated fault-replay or fault spoofing attack from actual faults. A software-based cybersecurity testbed has been developed for rigorous testing of the algorithm. The algorithm is further validated using simulated synchrophasor datasets obtained from a MinniWECC 63-bus test system. Results show that the algorithm can successfully detect fault-replay attacks even when over half of the PMUs are compromised.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗