Search NASASearch

SEARCH · Search NASA

Results for “flash”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A WRF-Chem Flash Rate Parameterization Scheme and LNOx Analysis of the 29-30 May 2012 Convective Event in Oklahoma During DC3

The Deep Convective Clouds and Chemistry (DC3) field campaign in 2012 provided a plethora of aircraft and ground-based observations (e.g., trace gases, lightning and radar) to study deep convective storms, their convective transport of trace gases, and associated lightning occurrence and production of nitrogen oxides (NOx). Based on the measurements taken of the 29-30 May 2012 Oklahoma thunderstorm, an analysis against a Weather Research and Forecasting Chemistry (WRF-Chem) model simulation of the same event at 3-km horizontal resolution was performed. One of the main objectives was to include various flash rate parameterization schemes (FRPSs) in the model and identify which scheme(s) best captured the flash rates observed by the National Lightning Detection Network (NLDN) and Oklahoma Lightning Mapping Array (LMA). The comparison indicates how well the schemes predicted the timing, location, and number of lightning flashes. The FRPSs implemented in the model were based on the simulated thunderstorms physical features, such as maximum vertical velocity, cloud top height, and updraft volume. Adjustment factors were applied to each FRPS to best capture the observed flash trend and a sensitivity study was performed to compare the range in model-simulated lightning-generated nitrogen oxides (LNOx) generated by each FRPS over the storms lifetime. Based on the best FRPS, model-simulated LNOx was compared against aircraft measured NOx. The trace gas analysis, along with the increased detail in the model specification of the vertical distribution of lightning flashes as suggested by the LMA data, provide guidance in determining the scenario of NO production per intracloud and cloud-to-ground flash that best matches the NOx mixing ratios observed by the aircraft.

Atmospheric chemistry

Normalized Temperature Contrast Processing in Infrared Flash Thermography

The paper presents further development in normalized contrast processing used in flash infrared thermography method. Method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided. Methods of converting image contrast to temperature contrast and vice versa are provided. Normalized contrast processing in flash thermography is useful in quantitative analysis of flash thermography data including flaw characterization and comparison of experimental results with simulation. Computation of normalized temperature contrast involves use of flash thermography data acquisition set-up with high reflectivity foil and high emissivity tape such that the foil, tape and test object are imaged simultaneously. Methods of assessing other quantitative parameters such as emissivity of object, afterglow heat flux, reflection temperature change and surface temperature during flash thermography are also provided. Temperature imaging and normalized temperature contrast processing provide certain advantages over normalized image contrast processing by reducing effect of reflected energy in images and measurements, therefore providing better quantitative data. Examples of incorporating afterglow heat-flux and reflection temperature evolution in flash thermography simulation are also discussed.

Koshti, Ajay M.

A Method to Measure and Estimate Normalized Contrast in Infrared Flash Thermography

The paper presents further development in normalized contrast processing used in flash infrared thermography method. Method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided. Methods of converting image contrast to temperature contrast and vice versa are provided. Normalized contrast processing in flash thermography is useful in quantitative analysis of flash thermography data including flaw characterization and comparison of experimental results with simulation. Computation of normalized temperature contrast involves use of flash thermography data acquisition set-up with high reflectivity foil and high emissivity tape such that the foil, tape and test object are imaged simultaneously. Methods of assessing other quantitative parameters such as emissivity of object, afterglow heat flux, reflection temperature change and surface temperature during flash thermography are also provided. Temperature imaging and normalized temperature contrast processing provide certain advantages over normalized image contrast processing by reducing effect of reflected energy in images and measurements, therefore providing better quantitative data. Examples of incorporating afterglow heat-flux and reflection temperature evolution in flash thermography simulation are also discussed.

Koshti, Ajay M.

Flash Drought as Captured by Reanalysis Data: Disentangling the Contributions of Precipitation Deficit and Excess Evapotranspiration

Flash droughts – uncharacteristically rapid dryings of the land system – are naturally associated with extreme precipitation deficits. Such precipitation deficits, however, do not tell the whole story, for land surface drying can be exacerbated by anomalously high evapotranspiration (ET) rates driven by anomalously high temperatures (e.g., during heatwaves), anomalously high incoming radiation (e.g., from reduced cloudiness), and other meteorological anomalies. In this study, the relative contributions of precipitation and ET anomalies to flash drought generation in the Northern Hemisphere are quantified through the analysis of diagnostic fields contained within the MERRA-2 reanalysis product. Unique to the approach is the explicit treatment of soil moisture impacts on ET through relationships diagnosed from the reanalysis data; under this treatment, an ET anomaly that is negative relative to the local long-term climatological mean is still considered positive in terms of its contribution to a flash drought if it is high for the concurrent value of soil moisture. Maps produced in the analysis show the fraction of flash drought production stemming specifically from ET anomalies and illustrate how ET anomalies for some droughts are related to temperature and radiation anomalies. While ET is found to have an important impact on flash drought production in the central US and in parts of Russia known from past studies to be prone to heatwave-related drought, and while this impact does appear stronger during the onset (first several days) of flash droughts, overall the contribution of ET to these droughts is small relative to the contribution of precipitation deficit.

R D Koster

Ohio River Basin Water Resources: Monitoring Flash Drought Potential and Quantifying the Hydrologic Impacts in the Ohio River Basin

Flash drought conditions emerge in a matter of weeks following persistent weather anomalies, such as high temperatures or large vapor pressure deficits, that drive increased evaporative demand. Vegetation response rapidly depletes soil moisture, threatening surface water supplies, triggering significant crop loss, and increasing wildfire risk. Drought indices sensitive to flash drought are currently not included in drought forecast models in the Ohio River Basin (ORB). The team assessed and compared drought indices, gauge-based data, and satellite measurements over the course of the September 2019 flash drought event in the Ohio River Basin to investigate environmental fingerprints throughout flash drought evolution. Potential leading flash drought indicators were compared to the Standardized Precipitation Index (SPI) to aid the National Weather Service (NWS) Ohio River Forecast Center and Kentucky Climate Center in producing early warning flash drought forecasts. These drought indices included Evaporative Demand Drought Index (EDDI), Standardized Precipitation Evapotranspiration Index (SPEI), and Landscape Evaporative Response Index (LERI) (derived from Terra Moderate Resolution Imaging Spectroradiometer (MODIS)). Drought index behavior inherently varies based on parameters incorporated - EDDI measures evaporative demand through potential evapotranspiration, and demonstrates more variations due to sensitivity to seasonal changes in evaporative demand throughout the 2010-2019 study period. Conversely, LERI measures evaporative response through actual evapotranspiration, representing different environmental changes. Soil moisture response was evaluated using Soil Moisture Active Passive (SMAP) L-band radiometer data and Kentucky Mesonet gauge-based measurements. This analysis enables climatologists and weather forecasters to keep decision-makers and stakeholders better informed about drought risks, and to implement the appropriate actions for preparation of drought onset.

Adelaide Schmid

Ohio River Basin Water Resources: Monitoring Flash Drought Potential and Quantifying the Hydrologic Impacts in the Ohio River Basin Utilizing NASA Earth Observations

Flash drought conditions emerge in a matter of weeks following persistent weather anomalies, such as high temperatures or large vapor pressure deficits, that drive increased evaporative demand. Vegetation response rapidly depletes soil moisture, threatening surface water supplies, triggering significant crop loss, and increasing wildfire risk. Drought indices sensitive to flash drought are currently not included in drought forecast models in the Ohio River Basin (ORB). The team assessed and compared drought indices, gauge-based data, and satellite measurements over the course of the September 2019 flash drought event in the Ohio River Basin to investigate environmental fingerprints throughout flash drought evolution. Potential leading flash drought indicators were compared to the Standardized Precipitation Index (SPI) to aid the National Weather Service (NWS) Ohio River Forecast Center and Kentucky Climate Center in producing early warning flash drought forecasts. These drought indices included Evaporative Demand Drought Index (EDDI), Standardized Precipitation Evapotranspiration Index (SPEI), and Landscape Evaporative Response Index (LERI) (derived from Terra Moderate Resolution Imaging Spectroradiometer (MODIS)). Drought index behavior inherently varies based on parameters incorporated -EDDI measures evaporative demand through potential evapotranspiration, and and demonstrates more variations due to sensitivity to seasonal changes in evaporative demand throughout the 2010-2019 study period. Conversely, LERI measures evaporative response through actual evapotranspiration, representing different environmental changes. Soil moisture response was evaluated using Soil Moisture Active Passive (SMAP) L-band radiometer data and Kentucky Mesonet gauge-based measurements. This analysis enables climatologists and weather forecasters to keep decision-makers and stakeholders better informed about drought risks to implement the appropriate actions for preparation of drought onset.

DEVELOP Project Summary

Prediction skill of the 2012 U.S. Great Plains flash drought in Subseasonal Experiment (SubX) models

Rapid-onset droughts, known as flash droughts, can have devastating impacts on agriculture, water resources, and ecosystems. The ability to predict flash droughts in advance would greatly enhance our preparation for them and potentially mitigate their impacts. Here, we investigate the prediction skill of the extreme 2012 flash drought over the U.S. Great Plains at subseasonal lead times (3 weeks or more in advance) in global forecast systems participating in the Subseasonal Experiment (SubX). An additional comprehensive set of subseasonal hindcasts with NASA’s GEOS model, a SubX model with relatively high prediction skill, was performed to investigate the separate contributions of atmospheric and land initial conditions to flash drought prediction skill. The results show that the prediction skill of the SubX models is quite variable. While skillful predictions are restricted to within the first two forecast weeks in most models, skill is considerably better (3-4 weeks or more) for certain models and initialization dates. The enhanced prediction skill is found to originate from two robust sources: 1) accurate soil moisture initialization once dry soil conditions are established, and 2) the satisfactory representation of quasi-stationary cross-Pacific Rossby wave trains that lead to the rapid intensification of flash droughts. Evidence is provided that the importance of soil moisture initialization applies more generally to central U.S. summer flash droughts. Our results corroborate earlier findings that accurate soil moisture initialization is important for skillful subseasonal forecasts and highlight the need for additional research on the sources and predictability of drought-inducing quasi-stationary atmospheric circulation anomalies.

Anthony M DeAngelis

NAND flash screening and qualification guideline for space application

All space missions have a need for nonvolatile memory (NVM), which maintains data integrity when unpowered. Types of NVM include PROM, EEPROM, NOR Flash, and NAND Flash. PROMs, NOR Flash, and EEPROMs are good choices for storing smaller file size data such as boot code or FPGA configurations. These products have excellent data retention characteristics and can reliably store data for years, unpowered, without any data corruption. They can also be read many times without disturbing the data. Another application of NVM is storage of science and engineering data, which requires large of amounts of memory. The highest density memories available today are SDRAM and NAND Flash. However, the power required to operate and store data in NAND Flash is far less than SDRAM. Wherever high density and low power is required, NAND Flash is very attractive.

Heidecker, Jason

Relating Lightning Flash Characteristics to Convective Structure in Tropical Cyclones

For decades, lightning has been used with some success as an indicator of tropical cyclone (TC) intensity change. An increase in inner-core lightning is usually associated with TC intensification, but this is not always the case. Significant lightning outbreaks have been observed in weakening storms, and hurricanes can rapidly intensify in the total absence of inner-core lightning. These conflicting results arise because lightning production depends on convective and microphysical characteristics that can arise during both intensification and weakening phases in TCs. Recent work using flash size and energy metrics provided by the Geostationary Lightning Mapper (GLM) aboard the GOES-R series of satellites shows some promise in distinguishing between lightning outbreaks that correspond to intensification and those that correspond to weakening. If a hurricane is rapidly intensifying in the presence of inner-core lightning, the size and optical energy of the flashes generally increases as intensification proceeds. It is hypothesized that this relationship is governed by changes in the TC-scale circulation that produce enhanced upper-level outflow and large, strongly helical convective updrafts in the inner core. These changes increase the quantity and spatial extent of charged upper-level ice, which allows large intracloud flashes to occur when electric field breakdown occurs. This presentation will present objective diagnostics of convective asymmetry using azimuthal wavenumber decomposition of GOES-R Advanced Baseline Imager brightness temperatures. The degree of symmetry will be related to GLM flash characteristics to better understand how changes in the symmetry of TC inner-core convection relates to flash rate, size, and energy. It will also show how the evolution of inner-core asymmetries relates to the spatial distribution and characteristics of lightning flashes in the inner core.

Patrick Duran

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

data retention

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

Data Retention

Environmental Effects on Data Retention in Flash Cells

Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Antifuse technology, prevalent in non-volatile field programmable gate arrays (FPGAs), will eventually be phased out as new devices have not been developed for approximately a decade. The reliance on flash technology presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. This paper will present the results of our on-going tests: long-term storage at 150 C for a small population of devices, neutron radiation exposure, electrostatic discharge (ESD) testing, and the trends of large populations (over 300 devices for each condition) exposed to three difference temperatures: 25 C, 125 C, and 150 C.

Flash

Intern Deliverable Poster; Arc Flash Analysis; Landon Palmer

This poster describes what arc flash is, and what causes it. The importance of arc flash analysis is discussed, including what incident energy/working distance mean. SKM Power*Tools is discussed as a means for performing an arc flash analysis and breaker coordination. Arc flash warning labels are explained, including why it is important that up to date information is present with any changes made to an electrical system. An example arc flash label is described to give readers a better understanding of key components.

99 - GENERAL AND MISCELLANEOUS

Visual light flash phenomenon, part C

The Apollo 16 mission provided the opportunity to obtain additional data on the characteristics and frequency of the light flashes and also provided the first opportunity to obtain a direct physical record of incident cosmic ray particles with the Apollo light flash moving emulsion detector (ALFMED). The ALFMED is an electromechanical device that is worn on the head like a helmet and supports cosmic radiation-sensitive emulsions around the head of the test subject. Two light flash observation sessions were conducted during the mission: one during translunar coast and the second during transearth coast. Characteristics of the light flashes observed and reported by the Apollo crew members were generally similar to those reported on previous missions. Analyses of the ALFMED emulsion plates are proceeding as scheduled, although results are not yet available. The ALFMED results should provide conclusive evidence establishing the correlation, if any, between the incident cosmic ray particles and the perception of light flashes as reported by Apollo crew members.

Richard E. Benson

Atomization and combustion properties of flashing injectors

Flashing injection involves expanding a fluid through an injector until a supersaturated state is reached, causing a portion of the fluid to flash to a vapor. This investigation considered the flow, atomization and spreading properties of flashing injectors flowing liquids containing dissolved gases (Jet A/air) as well as superheated liquids (Freon 11). The use of a two stage expansion process, separated by an expansion chamber, was found to be beneficial for good atomization properties of flashing injection - particularly for dissolved gas systems. Both locally homogeneous and separated flow models provided good predictions of injector flow properties. Conventional correlations for drop sizes from pressure atomized and airblast injectors were successfully modified, using the separated flow model to prescribe injector exit conditions, to correlate drop size measurements. Additional experimental results are provided for spray angle and combustion properties of sprays from flashing injectors.

Solomon, A. S. P.

Flow and atomization in flashing injectors

Flashing injection involves expanding a fluid through an injector until a supersaturated state is reached, causing a portion of the fluid to flash to a vapor. This investigation considered the flow, atomization and spreading properties of flashing injectors with flowing liquids containing dissolved gases (Jet A/air) as well as superheated liquids (Freon-11). The use of a two-stage expansion process, separated by an expansion chamber, was found to be beneficial for good atomization properties of flashing injection - particularly for dissolved gas systems. Both locally homogeneous and separated flow models provided good predictions of injector flow properties. Conventional correlations for drop sizes from pressure and airblast injectors were successfully modified, using the separated flow model to prescribe injector exit conditions, and to correlate drop size measurements. Additional experimental results are provided for spray angles of sprays from flashing injectors.

Solomon, A. S. P.

Optical flash background rates

Flash background rates are measured from August 18-September 5, 1985 using the Lowell 0.61-m telescope at CTIO and the 28-cm f/10 Schmidt-Cassegrain telescope at ESO. During 230.1 hours of observing 40 flash events were detected, and it was observed that the background events were dominated by meteors and satellites passing through the field-of-view. The measured flash rate is compared with that of Pedersen et al. (1984), and it is determined that the background flash rate that is applicable to the data of Pedersen et al. for February 8, 1984 is 0.023 events/hr. The morphology of that flash, which appears to be controlled by a gamma-ray burster, is examined.

Schaefer, B. E.