Search NASA⌕ Search

SEARCH · Search NASA

Results for “flash point”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A study of the comparative performance of six lightning warning systems

An analysis of mining explosive accident reports indicates a need for clear and ample warning of approaching electrical storms to reduce injuries/fatalities due to lightning induced premature detonation. Six lightning warning devices were comparatively evaluated at three test sites. The devices tested were: (1) flash counter, (2) corona point, (3) radioactive probe, (4) field mill, (5) azimuth/range locator, and (6) triangulation locator. The test sites were chosen to provide system evaluation under varied thunderstorm conditions. The devices were tested at San Antonio, Texas, Kennedy Space Center, Florida and Langmuir Laboratory, New Mexico. Comparative performance is reviewed in terms of alarm reliability, false alarm, and failure to alarm probabilities. Lightning warning system requirements and methods of relating warning criteria to explosive hazard are discussed.

Johnson, R. L.↗

Lightning Strike Distance Distribution Beyond a Preexisting Lightning Area

The 45th Weather Squadron (45 WS) asked the Applied Meteorology Unit (AMU) to review the 30-year-old, lightning stand-off distances of 5 nautical miles (nmi) for applicability to today's operations. This was based on the realization that previous lightning strike distance studies did not match how 45 WS issues lightning warnings (Roeder, 2008). The previous lightning distance studies were from the point of origin of the lightning or the average starting location that would tend to be in the core of the thunderstorm. However, the 45 WS issues lightning warnings based on the edge of a preexisting lightning area. Before beginning the AMU project, it took several years to develop a method to calculate a distance distribution beyond a preexisting area (Roeder, 2015). The AMU pulled Lightning Detection and Ranging (LDAR) sensor data from 1/1/2013 to 12/31/2013. This dataset consisted of 37 million individual source data points from the LDAR sensors. Only sources within 50 km north, south, east or west of the LDAR grid center were included in the dataset. This limited the use of LDAR data to that with the greatest accuracy of source detection and increased data processing. Points were grouped into flashes based on spatial and temporal criteria. Based on the sensitivity analysis the AMU performed on the flash clustering algorithm, a time value of 0.3 seconds was found to model flashes adequately. Distance parameters were tested from 1,500 to 7,500 meters (m) in 500 m increments. Distance parameters of both 3,000 m and 4,000 m produced results in the plotting tool that were most representative of the physical behavior of lightning. Thus statistics were gathered for the most representative of these spatial and temporal criteria on the flash size and the polygon expansion distance in order to find the correct data distributions. The best fit curves for the LDAR polygon expansion frequency vs. distances for both the 3 kilometer (km) and 4 km distance threshold values were exponential decay functions and had R2 values of > 0.998, indicating good model fits. The equations of the best fit curves were then used to calculate a desired safety radius of 4 nmi for either 3 km or 4 km distance threshold criteria. The AMU analysis concludes the safe reduction of the 5 nmi lightning warning circles to 4 nmi should improve the operational impact by 36% if based on distance from the center of the property area being protected. If based on the edge of the property being protected, then the reduction is 4.5 nmi to 4 nmi and the operational impact is decreased by 21%. For the 6 nmi lightning warning circles, the recommended 4 nmi stand-off distance will result in a safe reduction of operational impact of 31% if based on the center of the area being protected, or 16% if based on the edge of the property.

Flash clustering algorithm↗

A Global LIS/OTD Climatology of Lightning Flash Extent Density

Previous lightning climatologies derived from Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) total lightning measurements have quantified lightning frequency as a Flash Rate Density (FRD). This approach assumes that lightning flashes can be represented as points and quantifies the frequency of lightning centered in each grid cell. However, lightning has a finite extent that can reach hundreds of kilometers. A new climatology based on Flash Extent Density (FED) is constructed for LIS (including ISS-LIS) and OTD that accounts for the horizontal dimension of lightning. The FED climatology documents the frequency that an observer can expect lightning to be visible overhead—regardless of where the flash began or ended. This new FED climatology confirms and elaborates on the previous global LIS/OTD FRD and Americas-only Geostationary Lightning Mapper (GLM) findings. The FED climatology maintains Lake Maracaibo as the global lightning hotspot with an average of 389 flashes/day but designates Karabre in the Democratic Republic of the Congo as the global thunderstorm duty (percent of the total viewtime where lightning is observed) hotspot at 7.29%. Meanwhile, Kuala Lumpur is the national capital city with the most lightning, and its airport (KUL) is the top major airport affected by lightning (in terms of duty). The FED seasonal cycle and month-to-month changes in the “center of lightning” for the three continental chimney regions are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Early-stage dynamics of chloride ion–pumping rhodopsin revealed by a femtosecond X-ray laser

Chloride ion–pumping rhodopsin (ClR) in some marine bacteria utilizes light energy to actively transport Cl – into cells. How the ClR initiates the transport is elusive. Here, we show the dynamics of ion transport observed with time-resolved serial femtosecond (fs) crystallography using the Linac Coherent Light Source. X-ray pulses captured structural changes in ClR upon flash illumination with a 550 nm fs-pumping laser. High-resolution structures for five time points (dark to 100 ps after flashing) reveal complex and coordinated dynamics comprising retinal isomerization, water molecule rearrangement, and conformational changes of various residues. Combining data from time-resolved spectroscopy experiments and molecular dynamics simulations, this study reveals that the chloride ion close to the Schiff base undergoes a dissociation–diffusion process upon light-triggered retinal isomerization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge distribution in lightning flashes

Four VHF receivers about 10 km apart were used to detect three-dimensional lightning VHF sources during active thunderstorms. A computer implemented algorithm was used to determine the difference in the time of arrival (DTOA) between the VHF pulses. The three-dimensional source locations determined from the DTOA were correlated with ground electric field measurements (0.1 Hz to 1.5 MHz). Four cloud to ground (CG) and three intracloud (IC) flashes, selected randomly, were studied. A point charge model was used to determine the charge being removed during the different phases of CG and IC flashes. It was determined that return strokes lowered between 24.1 and 3.6 coulombs of negative charge to ground from heights between 10.5 and 5.8 km above MSL. The interstroke process after the first return stroke in a CG flash lowered between 3.4 and 0.9 coulombs of negative charge between the heights of 14.2 (near the cloud tops) to heights of 5.8 km (near the beginning of the leader-return stroke process).

Rustan, P. L.↗

SiC-Based Wireless Power Transformation for Data Centers & Medium Voltage Applications

Data centers have grown in physical size and their electrical power consumption has grown to levels of several 100kW and approaching 1 GW in large installations. The low voltage electrical distribution inside of Data Centers consists of several conversion stages and a lot of wiring to bring the power from medium voltage (MV) levels outside of the building to the low voltage levels that the servers and racks require. Energy losses during distribution and conversion and high incident arc flash energy levels at the point of use are significant. The electrical distribution system is complex and costly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Obtaining the Grobner Initialization for the Ground Flash Fraction Retrieval Algorithm

At optical wavelengths and from the vantage point of space, the multiple scattering cloud medium obscures one's view and prevents one from easily determining what flashes strike the ground. However, recent investigations have made some progress examining the (easier, but still difficult) problem of estimating the ground flash fraction in a set of N flashes observed from space In the study by Koshak, a Bayesian inversion method was introduced for retrieving the fraction of ground flashes in a set of flashes observed from a (low earth orbiting or geostationary) satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters, a scalar function of three variables (one of which is the ground flash fraction) was minimized by a numerical method. This method has formed the basis of a Ground Flash Fraction Retrieval Algorithm (GoFFRA) that is being tested as part of GOES-R GLM risk reduction.

Solakiewicz, R.↗

Megavolt bremsstrahlung measurements from linear induction accelerators demonstrate possible use as a FLASH radiotherapy source to reduce acute toxicity

Abstract Recent studies indicate better efficacy and healthy tissue sparing with high dose-rate FLASH radiotherapy (FLASH-RT) cancer treatment. This technique delivers a prompt high radiation dose rather than fractional doses over time. While some suggest thresholds of > 40 Gy s −1 with a maximal effect at > 100 Gy s −1 , accumulated evidence shows that instantaneous dose-rate and irradiation time are critical. Mechanisms are still debated, but toxicity is minimized while inducing apoptosis in malignant tissue. Delivery technologies to date show that a capability gap exists with clinic scale, broad area, deep penetrating, high dose rate systems. Based on these trends, if FLASH-RT is adopted, it may become a dominant approach except in the least technologically advanced countries. The linear induction accelerator (LIA) developed for high instantaneous and high average dose-rate, species independent charged particle acceleration, has yet to be considered for this application. We review the status of LIA technology, explore the physics of bremsstrahlung-converter-target interactions and our work on stabilizing the electron beam. While the gradient of the LIA is low, we present our preliminary work to improve the gradient by an order of magnitude, presenting a point design for a multibeam FLASH-RT system using a single accelerator for application to conformal FLASH-RT.

42 ENGINEERING↗

A Multipole Expansion Method for Analyzing Lightning Field Changes

Changes in the surface electric field are frequently used to infer the locations and magnitudes of lightning-caused changes in thundercloud charge distributions. The traditional procedure is to assume that the charges that are effectively deposited by the flash can be modeled either as a single point charge (the Q model) or a point dipole (the P model). The Q model has four unknown parameters and provides a good description of many cloud-to-ground (CG) flashes. The P model has six unknown parameters and describes many intracloud (IC) discharges. In this paper we introduce a new analysis method that assumes that the change in the cloud charge can be described by a truncated multipole expansion, i.e., there are both monopole and dipole terms in the unknown source distribution, and both terms are applied simultaneously. This method can be used to analyze CG flashes that are accompanied by large changes in the cloud dipole moment and complex IC discharges. If there is enough information content in the measurements, the model can also be generalized to include quadrupole and higher order terms. The parameters of the charge moments are determined using a dme-dimensional grid search in combination with a linear inversion, and because of this, local minima in the error function and the associated solution ambiguities are avoided. The multipole method has been tested on computer-simulated sources and on natural lightning at the NASA Kennedy Space Center and U.S. Air Force Eastern Range.

Koshak, William J.↗

Florida Thunderstorms: A Faucet of Reactive Nitrogen to the Upper Troposphere

During the NASA Cirrus Regional Study of Tropical Anvils and Cirrus Layers-Florida Area Cirrus Experiment (CRYSTAL-FACE) enhanced mixing ratios of nitric oxide were measured in the anvils of thunderstorms and in clear air downwind of storm systems on flights of a Wl3-57F high-altitude aircraft. Mixing ratios greater than l0 - 20 times background were readily observed over distances of 25-120 km due to lightning activity. In many of the Florida storms deposition of NO occurred up to near the tropopause but major deposition usually occurred 1 - 2 km below the tropopause, or mostly within the visible anvil volume formed prior to storm decay. Observations from two storms of very different anvil size and electrical activity allowed estimates of the total mass of NO, vented to the middle and upper troposphere. Using the cloud-to ground (CG) flash accumulations from the National Lightning Detection Network, climatological intra-cloud (IC) to CG ratios, and assuming that CG and IC flashes were of equivalent efficiency for NO production, the ranges of production per flash for a moderate-sized and a large storm were (0.51 - 1.0) x l0(exp 26) and (2.3 - 3.1) x 10(exp 26) molecules NO/flash, respectively. Using the recently determined average global flash rate of 44 8, a gross extrapolation of these two storms to represent possible global annual production rates yield 1.6 - 3.2 and 7.3 - 9.9 Tg(N)/yr, respectively. If the more usual assumption is made that IC efficiency is l/l0th that of CG activity, the ranges of production for the moderate-sized and large storm were (1.3 - 2.7) x l0(exp 26) and (6.0 - 8.1) x l0(exp 26) molecules NO/CG flash, respectively. The estimates from the large storm may be high because there is indirect evidence that the IC/CG ratio was larger than would be derived from climatology. These two storms and others studied did not have flash rates that scaled as approx. H(sup 5) where H is the cloud top altitude. The observed CG flash accumulations and NO(x) mass production estimate for the month of July over the Florida area were compared with a representative 3D global Chemistry-Transport Model (CTMJ that uses the Price et al. lightning parameterization. For two land grid points representing the Florida peninsula the model compared well with the observations: CG flash rates were low by only a factor of approx. 2. When the model grid points included the coastal regions of Florida the flash accumulations were lower than observed by a factor of 3.4 - 4.6. It is recommended that models using the Price et al. parameterization allow any global coastal grid point to maintain the land rather than the marine flash rate parameterization. The convection in this CTM underestimated the actual cloud top heights over Florida by 1 - 2 km and thus the total lightning flash rates and the altitude range of reactive nitrogen deposition. Broad scale (20 - 120 km) median mixing ratios of NO within anvils over Florida were significantly larger than in storms previously investigated over Colorado and New Mexico.

Ridley, B.↗

A Multipole Expansion Method for Analyzing Lightning Field Changes

Changes in the surface electric field are frequently used to infer the locations and magnitudes of lightning-caused changes in thundercloud charge distributions. The traditional procedure is to assume that the charges that are effectively deposited by the flash can be modeled either as a single point charge (the Q-model) or a point dipole (the P-model). The Q-model has 4 unknown parameters and provides a good description of many cloud-to-ground (CG) flashes. The P-model has 6 unknown parameters and describes many intracloud (IC) discharges. In this paper, we introduce a new analysis method that assumes that the change in the cloud charge can be described by a truncated multipole expansion, i.e., there are both monopole and dipole terms in the unknown source distribution, and both terms are applied simultaneously. This method can be used to analyze CG flashes that are accompanied by large changes in the cloud dipole moment and complex IC discharges. If there is enough information content in the measurements, the model can also be generalized to include quadrupole and higher order terms. The parameters of the charge moments are determined using a 3-dimensional grid search in combination with a linear inversion, and because of this, local minima in the error function and the associated solution ambiguities are avoided. The multipole method has been tested on computer simulated sources and on natural lightning at the NASA Kennedy Space Center and USAF Eastern Range.

Koshak, William J.↗

The photochemical cycle of bacteriorhodopsin

The reaction cycle of bacteriorhodopsin in the purple membrane isolated from Halobacterium halobium has been studied by optical absorption spectroscopy using low-temperature and flash kinetic techniques. After absorption of light, bacteriorhodopsin passes through at least five distinct intermediates. The temperature and pH dependence of the absorbance changes suggests that branch points and/or reversible steps exist in this cycle. Flash spectroscopy in the presence of a pH-indicating dye shows that the transient release of a proton accompanies the photoreaction cycle. The proton release occurs from the exterior and the uptake is on the cytoplasmic side of the membrane, as required by the function of bacteriorhodopsin as a light-driven proton pump. Proton translocating steps connecting release and uptake are indicated by deuterium isotope effects on the kinetics of the cycle. The rapid decay of a light-induced linear dichroism shows that a chromophore orientation change occurs during the reaction cycle.

Lozier, R. H.↗

Flash Neutron Imaging [Poster]

The NNSS has extensive historical experience with high-fidelity flash neutron imaging which may be applicable to the needs of NA-22. In recent neutron imaging tests, a dense plasma focus (DPF) discharges a capacitor bank across a hydrogen-filled diode to create a flash of fusion neutrons emitted from a point, which can be used for active interrogation. Object inspection may include both radiography transmission imaging as well as emission imaging of the subject via an aperture. A scintillator screen (coupled to a low-Z converter when necessary) converts deposited energy to visible light, which is relayed through optics to an ultra-sensitive visible imager contained in a light-tight box. Flash photon imaging, utilizing bremsstrahlung emission instead of fusion neutrons, is also available and is more mature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Saturn's central flash from the 3 July 1989 occultation of 28 Sgr

We present observations of Saturn's central flash obtained from Palomar and McDonald Observatories during the 3 July 1989 occultation of 28 Sgr. As the star passed close to the geometric center of Saturn's shadow, the focusing of the incident starlight by the planet's atmosphere formed multiple stellar images along the limb which were detected in infrared images obtained at wavelengths of 3.9 (Palomar) and 2.1 microns (McDonald). These are the first reported observations of a central flash due to Saturn, and the first of any planet in which the signal flash from each stellar image could be determined separately, permitting a comparison of both intensity and position for each image with model predictions. Four separate flashes were observed from each observatory, corresponding to points on the limb where the starlight passed through the Cassini Division and the relatively transparent C Ring, with maximum brightness reaching 1-2% of the unocculted stellar intensity. The timing of the flashes is quite sensitive to the shape of Saturn's limb, which depends in turn on the planet's zonal gravity harmonics and on the zonal wind profile in the lower stratosphere, near the 2.5-mbar pressure level. The locations of the images along the limb, as well as the timing, shapes, and amplitudes of the individual flash light curves, are well matched by a smoothed model based on a tropospheric zonal wind profile obtained from tracking cloud features in Voyager images and the Saturn ring optical depth profile obtained from the Voyager Photopolarimeter experiment. The smoothing required to give the best match to the data exceeds that attributable to the finite angular extent of the occulted star and may be due to refractive scattering by turbulence or wave structure in Saturn's atmosphere. There is no evidence of significant atmospheric absorption at the observed wavelengths, which correspond to spectral regions of weak methane absorption.

Nicholson, Philip D.↗

Spatial Structure of Precipitation and Lightning in the Vicinity of Wildfire Ignitions in the United States

The horizontal storm structure surrounding 92512 lightning ignited wildfires is examined in the mid to eastern sections of the United States from 2003-2015 using Vaisala’s National Lightning Detection Network (NLDN), NCEP’s Stage IV gauge corrected radar precipitation mosaic, and the US Forest Service’s Fire Occurrence Database. Though lightning flash density peaks strongly around fire ignitions on the instantaneous 1 km scale, on the hourly 10 km scale both the lightning and precipitation peaks are typically offset from fire ignitions. As expected, lightning density is higher and precipitation lower around ignition points compared to non-ignition points. The average spatial distribution of total lightning flashes around fire ignitions is symmetrical, while that of precipitation and positive flashes is not. The results of regressing positive and negative currents against ignition efficiency are ambiguous. These results can aid in modeling storms that are likely to produce the "dry lightning" associated with wildfire ignitions.

Brian Vant-Hull↗

Super Resolution Image Enhancement for a Flash Lidar: Back Projection Method

In this paper a new image processing technique for flash LIDAR data is presented as a potential tool to enable safe and precise spacecraft landings in future robotic or crewed lunar and planetary missions. Flash LIDARs can generate, in real-time, range data that can be interpreted as a 3-dimensional (3-D) image and transformed into a corresponding digital elevation map (DEM). The NASA Autonomous Landing and Hazard Avoidance (ALHAT) project is capitalizing on this new technology by developing, testing and analyzing flash LIDARs to detect hazardous terrain features such as craters, rocks, and slopes during the descent phase of spacecraft landings. Using a flash LIDAR for this application looks very promising, however through theoretical and simulation analysis the ALHAT team has determined that a single frame, or mosaic, of flash LIDAR data may not be sufficient to build a landing site DEM with acceptable spatial resolution, precision, size, or for a mosaic, in time, to meet current system requirements. One way to overcome this potential limitation is by enhancing the flash LIDAR output images. We propose a new super-resolution algorithm applicable to flash LIDAR range data that will create a DEM with sufficient accuracy, precision and size to meet current ALHAT requirements. The performance of our super-resolution algorithm is analyzed by processing data generated during a series of simulation runs by a high fidelity model of a flash LIDAR imaging a high resolution synthetic lunar elevation map. The flash LIDAR model is attached to a simulated spacecraft by a gimbal that points the LIDAR to a target landing site. For each simulation run, a sequence of flash LIDAR frames is recorded and processed as the spacecraft descends toward the landing site. Each run has a different trajectory profile with varying LIDAR look angles of the terrain. We process the output LIDAR frames using our SR algorithm and the results show that the achieved level of accuracy and precision of the SR generated landing site DEM is more than adequate for detecting hazardous terrain features and identifying safe areas.

Bulyshev, Alexander↗

A computer code for performance of spur gears

In spur gears both performance and failure predictions are known to be strongly dependent on the variation of load, lubricant film thickness, and total flash or contact temperature of the contacting point as it moves along the contact path. The need of an accurate tool for predicting these variables has prompted the development of a computer code based on recent findings in EHL and on finite element methods. The analyses and some typical results which to illustrate effects of gear geometry, velocity, load, lubricant viscosity, and surface convective heat transfer coefficient on the performance of spur gears are analyzed.

Wang, K. L.↗