Search NASA⌕ Search

SEARCH · Search NASA

Results for “flash storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

FueL Additives for Solid Hydrogen (FLASH) Carriers for Electric Aviation

Most UAV technologies currently rely on (non-renewable) electric power. Fuel cells with material-based H2 storage addresses this limitation and can be cost effective. The goals of this project are to develop FLASH formulation that can deliver 6g H2/100g fuel, to design, build and test fuel cell cartridge compatible with FLASH, and to test FLASH with 600 W fuel cell system and quantify cartridge and system specific energy.

AMR↗

A Radiation-Tolerant, Low-Power Non-Volatile Memory Based on Silicon Nanocrystal Quantum Dots

Nanocrystal nonvolatile floating-gate memories are a good candidate for space applications - initial results suggest they are fast, more reliable and consume less power than conventional floating gate memories. In the nanocrystal based NVM device, charge is not stored on a continuous polysilicon layer (so-called floating gate), but instead on a layer of discrete nanocrystals. Charge injection and storage in dense arrays of silicon nanocrystals in SiO2 is a critical aspect of the performance of potential nanocrystal flash memory structures. The ultimate goal for this class of devices is few- or single-electron storage in a small number of nanocrystal elements. In addition, the nanocrystal layer fabrication technique should be simple, 8-inch wafer compatible and well controlled in program/erase threshold voltage swing was seen during 100,000 program and erase cycles. Additional near-term goals for this project include extensive testing for radiation hardness and the development of artificial layered tunnel barrier heterostructures which have the potential for large speed enhancements for read/write of nanocrystal memory elements, compared with conventional flash devices. Additional information is contained in the original extended abstract.

Bell, L. D.↗

A radiation - tolerant, low - power non - volatile memory based on silicon nanocrystal quantum dots.

Nanocrystal nonvolatile floating-gate memories are a good candidate for space applications - initial results suggest they are fast, more reliable and consume less power than conventional floating gate memories. In the nanocrystal based NVM device, charge is not stored on a continuous polysilicon layer (so-called floating gate), but instead on a layer of discrete nanocrystals. Charge injection and storage in dense arrays of silicon nanocrystals in Si02 is a critical aspect of the performance of potential nanocrystal flash memory structures. The ultimate goal for this class of devices is few- or single-electron storage in a small number of nanocrystal elements. In addition, the nanocrystal layer fabrication technique should be simple, 8-inch wafer compatible and well controlled.

Green, M. L.↗

ABSORPTION CHILLER AND STRATIFIED CHILLED-WATER STORAGE TANK CONFIGURATIONS FOR COUPLING TO A SMALL MODULAR REACTOR

Power maneuvers stemming from time-varying loads imposed on nuclear reactors from diurnal changes in demand and renewable intermittency can be detrimental to the life of the reactor. Temperature swings during power maneuvers result in thermal and mechanical stresses in fuel elements and other reactor components. Thermal Energy Storage (TES) reservoirs can be coupled to reactors to absorb these grid instabilities. Previous work has shown chilled-water storage can help shift cooling loads that contribute to the daily peak electric demand from on-peak to off-peak hours. The objective of this work is to evaluate a stratified chilled-water storage tank as a potential TES reservoir for a Small Modular Reactor (SMR) using absorption chillers for chilled-water production. Simulation results reveal absorption chiller performance is hindered when receiving steam from a tap on the low-pressure turbine. A better configuration involves integrating the absorption chillers into a flash vessel system that is thermally coupled to a sensible heat storage system. The sensible heat storage system maintains reactor thermal output at 100% and matches turbine output with demand while producing enough steam to power four large absorption chillers to charge a stratified chilled-water storage tank, which is used to offset cooling loads in an adjacent facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Architecture and performance of Perlmutter's 35 PB ClusterStor E1000 all-flash file system

NERSC's newest system, Perlmutter, features a 35 PB all-flash Lustre file system built on HPE Cray ClusterStor E1000. Here, we present its architecture, early performance figures, and performance considerations unique to this architecture. We demonstrate the performance of E1000 OSSes through low-level Lustre tests that achieve over 90% of the theoretical bandwidth of the SSDs at the OST and LNet levels. We also show end-to-end performance for both traditional dimensions of I/O performance (peak bulk-synchronous bandwidth) and nonoptimal workloads endemic to production computing (small, incoherent I/Os at random offsets) and compare them to NERSC's previous system, Cori, to illustrate that Perlmutter achieves the performance of a burst buffer and the resilience of a scratch file system. Finally, we discuss performance considerations unique to all-flash Lustre and present ways in which users and HPC facilities can adjust their I/O patterns and operations to make optimal use of such architectures.

97 MATHEMATICS AND COMPUTING↗

Conceptual Basis and Techno-Economic Modeling for Integrated Algal Biorefinery Conversion of Microalgae to Fuels and Products (2019 NREL TEA Update: Highlighting Paths to Future Cost Goals via a New Pathway for Combined Algal Processing)

The report documents the conceptual basis for a new potential Combined Algal Processing design strategy which may allow more flexibility in accommodating different algal biomass feedstock compositions, by enabling upgrading of both protein and carbohydrates in a single step, without a strict requirement for either component to be in soluble or monomeric form, while maintaining effective wet lipid extraction techniques to enable high lipid recoveries. In light of previously-established constraints around algal biomass costs (which are significantly higher than lignocellulosic terrestrial biomass), the present CAP processing strategy reflects an integrated biorefinery concept producing both fuels and value-added chemical coproducts as a means to improve profitability and generate coproduct revenues to help drive down the minimum fuel selling price (MFSP) towards economically viable levels. Namely, this report highlights an integrated CAP biorefinery process and associated technical targets that would be required to achieve U.S. Department of Energy target MFSP goals of $2.5/gallon gasoline equivalent by 2030. This is accomplished by a process involving low-cost seasonal storage of algal biomass during high-growth seasons, rapid flash hydrolysis pretreatment of the biomass, solvent extraction of pretreated biomass, cleanup and fractionation of lipids into triglyceride and free fatty acid fractions, and a series of thermochemical conversion steps to upgrade carbohydrates and protein to hydrocarbon fuels. These steps include mild oxidative treatment (MOT), a process originally investigated at NREL for upgrading lignin, followed by catalytic ketonization and hydrotreating of MOT products to fuels. Isolated triglycerides are sent to a coproduct train, with the base case focused on upgrading to polyurethane foams as a high-value, high-market-volume coproduct.

09 BIOMASS FUELS↗

Geologic Thermal Energy Storage of Solar Heat to Provide a Source of Dispatchable Renewable Power and Seasonal Energy Storage Capacity

This paper concludes that there is a cost-effective strategy for seasonal storage of heat that will provide firm, but dispatchable, electrical generating capacity in times when other renewable energy is not available to meet demand. Deployment of the technology appears to require no new technology, but instead combines solar, geothermal, and conventional oil and gas drilling technologies in a novel way. The study basis is the use of sedimentary geologic formations as a medium for thermal energy storage (TES), specifically for heat collected in concentrating solar collectors.

40 EE - Geothermal Technologies Office (EE-4G)↗

Vacuum drying of spent fuel storage canisters/casks - 'just how much water could be left in there, anyway?' - 15233

The process of moving spent fuel assemblies from wet storage in the spent fuel pool to dry storage in an inert gas environment within a canister or cask typically involves two main stages. In the first stage, the bulk of the water is removed by a draining or siphoning operation, conducted with pressure inside the canister maintained at 1.3 to 2 atm. This process removes most of the water in the cask cavity, but residual water can be left behind, in three main regions. The largest region, typically, is the bottom of the cavity below the end of the siphon tube. A second general class of locations, also located at the bottom of the cask cavity, consists of the 'dashpots' at the ends of the various non-fuel tubular structures within the fuel assemblies. For PWR assemblies, these are the control rod guide sleeve tubes and instrumentation thimbles. For BWR assemblies, these are the water rods of various designs and control blade ends in some configurations. A third class of locations consists of porous material within the cavity that can absorb water, such as thin ceramic neutron poison plates, and ostensibly intact fuel rods that nevertheless might have pinholes or fine cracks in the cladding that could allow pool water to creep inside the fuel rod. To remove residual water from these locations, the second stage of drying operations utilizes vacuum drying, by reducing the pressure sufficiently to convert the water to vapor that can then be pumped out of the canister cavity. In this operation, the cask cavity pressure is slowly reduced from the nominal condition of (1.3-2.0 atm (1000-1520 torr), to a final target pressure below 3 torr (0.004 atm). This is typically accomplished in three to five stages, with prescribed 'hold' points defined in procedures or in the Technical Specifications, to preclude sudden pressure spikes due to flashing of water to steam, or development of large local temperature gradients in the fuel rods or other cask internal components. This paper discusses the various locations in the system where residual water may 'hang up' in the cask, and presents a discussion of the physical basis for the effectiveness of vacuum drying for removing it. Results and conclusions based on realistic qualitative and quantitative evaluations of the transient heat transfer behavior of the system are presented, based on detailed modeling of a range of spent fuel canister designs and decay heat loads, most notably the 24P Dry Shielded Canisters (DSCs) stored at the Rancho Seco Independent Spent Fuel Storage Installation (ISFSI), the NAC-MPC modules at Maine Yankee, the 24P DSCs stored at Calvert Cliffs, and the Holtec HI-STORM modules at Hope Creek. The evaluations presented here show that ice formation within a spent fuel canister is highly unlikely, due to the availability of a large thermal source term in the form of the decay heat load of the spent fuel. The formation of ice is an operational concern, since it mainly affects operation of equipment external to the canister (i.e., the hoses, valves, and fittings of the vacuum drying equipment.) Evaluations are presented for quantifying the amount of residual water that could remain in the cask cavity, even after successful drying operations, since vacuum drying is a limit process, and by definition, cannot remove all of the water from the cavity, no matter how long the operation goes on, even if all of it is in vapor form. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Movement Dominates: Final Report

Over the past three years in this project, what we have observed is that the primary reason for data movement in large-scale systems is that the per-node capacity is not large enough—i.e., one of the solutions to the data-movement problem (certainly not the only solution that is required, but a significant one nonetheless) is to increase per-node capacity so that inter-node traffic is reduced. This unfortunately is not as simple as it sounds. Today’s main memory systems for datacenters, enterprise computing systems, and supercomputers, fail to provide high per-socket capacity [Dirik & Jacob 2009; Cooper-Balis et al. 2012], except at extremely high price points (factors of 10–100x the cost/bit of consumer main-memory systems) [Stokes 2008]. The reason is that our choice of technology for today’s main memory systems—i.e., DRAM, which we have used as a main-memory technology since the 1970s [Jacob et al. 2007]—can no longer keep up with our needs for density and price per bit. Main memory systems have always been built from the cheapest, densest, lowest-power memory technology available, and DRAM is no longer the cheapest, the densest, nor the lowest-power storage technology out there. It is now time for DRAM to go the way that SRAM went: move out of the way for a cheaper, slower, denser storage technology, and become a cache instead. This inflection point has happened before, in the context of SRAM yielding to DRAM. There was once a time that SRAM was the storage technology of choice for all main memories [Tomasulo 1967; Thornton 1970; Kidder 1981]. However, once DRAM hit volume production in the 1970s and 80s, it supplanted SRAM as a main memory technology because it was cheaper, and it was denser. It also happened to be lower power, but that was not the primary consideration of the day. At the time, it was recognized that DRAM was much slower than SRAM, but it was only at the supercomputer level (For instance the Cray X-MP in the 1980s and its follow-on, the Cray Y-MP, in the 1990s) that could one afford to build ever- larger main memories out of SRAM—the reasoning for moving to DRAM was that an appropriately designed memory hierarchy, built of DRAM as main memory and SRAM as a cache, would approach the performance of SRAM, at the price-per-bit of DRAM [Mashey 1999]. Today it is quite clear that, were one to build an entire multi-gigabyte main memory out of SRAM instead of DRAM, one could improve the performance of almost any computer system by up to an order of magnitude—but this option is not even considered, because to build that system would be prohibitively expensive. It is now time to revisit the same design choice in the context of modern technologies and modern systems. For reasons both technical and economic, we can no longer afford to build ever-larger main memory systems out of DRAM. Flash memory, on the other hand, is significantly cheaper and denser than DRAM and therefore should take its place. While it is true that flash is significantly slower than DRAM, one can afford to build much larger main memories out of flash than out of DRAM, and we show that an appropriately designed memory hierarchy, built of flash as main memory and DRAM as a cache, will approach the performance of DRAM, at the price-per-bit of flash. In our studies as part of this project, we have investigated Non-Volatile Main Memory (NVMM), a new main-memory architecture for large-scale computing systems, one that is specifically designed to address the weaknesses described previously. In particular, it provides the following features: non-volatility: The bulk of the storage is comprised of NAND flash, and in this organization DRAM is used only as a cache, not as main memory. Furthermore, the flash is journaled, which means that operations such as checkpoint/restore are already built into the system. 1+ terabytes of storage per socket: SSDs and DRAM DIMMs have roughly the same form factor (several square inches of PCB surface area), and terabyte SSDs are now commonplace. performance approaching that of DRAM: DRAM is used as a cache to the flash system. price-per-bit approaching that of NAND: Flash is currently well under $0.50 per gigabyte; DDR3 SDRAM is currently just over $10 per gigabyte [Newegg 2014]. Even today, one can build an easily affordable main memory system with a terabyte or more of NAND storage per CPU socket (which would be extremely expensive were one to use DRAM), and our cycle- accurate, full-system experiments show that this can be done at a performance point that lies within a factor of two of DRAM.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Pressure tunes electrical resistivity by four orders of magnitude in amorphous Ge[subscript 2]Sb[subscript 2]Te[subscript 5] phase-change memory alloy

Ge-Sb-Te-based phase-change memory is one of the most promising candidates to succeed the current flash memories. The application of phase-change materials for data storage and memory devices takes advantage of the fast phase transition (on the order of nanoseconds) and the large property contrasts (e.g., several orders of magnitude difference in electrical resistivity) between the amorphous and the crystalline states. Despite the importance of Ge-Sb-Te alloys and the intense research they have received, the possible phases in the temperature-pressure diagram, as well as the corresponding structure-property correlations, remain to be systematically explored. In this study, by subjecting the amorphous Ge{sub 2}Sb{sub 2}Te{sub 5} (a-GST) to hydrostatic-like pressure (P), the thermodynamic variable alternative to temperature, we are able to tune its electrical resistivity by several orders of magnitude, similar to the resistivity contrast corresponding to the usually investigated amorphous-to-crystalline (a-GST to rock-salt GST) transition used in current phase-change memories. In particular, the electrical resistivity drops precipitously in the P = 0 to 8 GPa regime. A prominent structural signature representing the underlying evolution in atomic arrangements and bonding in this pressure regime, as revealed by the ab initio molecular dynamics simulations, is the reduction of low-electron-density regions, which contributes to the narrowing of band gap and delocalization of trapped electrons. At P > 8 GPa, we have observed major changes of the average local structures (bond angle and coordination numbers), gradually transforming the a-GST into a high-density, metallic-like state. This high-pressure glass is characterized by local motifs that bear similarities to the body-centered-cubic GST (bcc-GST) it eventually crystallizes into at 28 GPa, and hence represents a bcc-type polyamorph of a-GST.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HybridStore: A Cost-Efficient, High-Performance Storage System Combining SSDs and HDDs

Unlike the use of DRAM for caching or buffering, certain idiosyncrasies of NAND Flash-based solid-state drives (SSDs) make their integration into existing systems non-trivial. Flash memory suffers from limits on its reliability, is an order of magnitude more expensive than the magnetic hard disk drives (HDDs), and can sometimes be as slow as the HDD (due to excessive garbage collection (GC) induced by high intensity of random writes). Given these trade-offs between HDDs and SSDs in terms of cost, performance, and lifetime, the current consensus among several storage experts is to view SSDs not as a replacement for HDD but rather as a complementary device within the high-performance storage hierarchy. We design and evaluate such a hybrid system called HybridStore to provide: (a) HybridPlan: improved capacity planning technique to administrators with the overall goal of operating within cost-budgets and (b) HybridDyn: improved performance/lifetime guarantees during episodes of deviations from expected workloads through two novel mechanisms: write-regulation and fragmentation busting. As an illustrative example of HybridStore s ef cacy, HybridPlan is able to nd the most cost-effective storage con guration for a large scale workload of Microsoft Research and suggest one MLC SSD with ten 7.2K RPM HDDs instead of fourteen 7.2K RPM HDDs only. HybridDyn is able to reduce the average response time for an enterprise scale random-write dominant workload by about 71% as compared to a HDD-based system.

Kim, Youngjae↗

Management and dewatering of brines extracted from geologic carbon storage sites

Subsurface pressure management is a significant challenge in geologic CO 2 storage. Elevated pressure generated from the injection of supercritical CO 2 can be managed by the withdrawal of brine from saline formations before or during CO 2 injection; however, management of the extracted brines is non-trivial because they may have high concentrations of dissolved solids and other contaminants. Dewatering a brine can reduce the volume needing disposal; in addition, water separated from the brine can be a source of usable low salinity water. This review will summarize the composition of brines extracted from select domestic geologic CO 2 storage sites, will calculate the minimum of work of dewatering, and will provide a critical review of developed and developing desalination/dewatering technologies that could be applied to brines extracted from saline formations before or during geologic CO 2 storage operations. Herein are also highlighted, when appropriate, the similarities and the differences between dewatering brines produced from oil/gas operations and brines extracted from geologic CO 2 storage. Since a source of steam or natural gas is likely unavailable/unsuitable for dewatering brines extracted during CO 2 storage, the ideal treatment processes should have a high electrical efficiency and, if possible, should be able to take advantage of the inherent elevated temperature of these brines.

42 ENGINEERING↗

DOE Zero Energy Ready Home Case Study: Weiss Building & Development, Downers Grove, Illinois

This single-family home built in a peat bog has underground storage tanks and drainage tanks, blown fiberglass insulation, coated rigid polyisocyanurate, and flashing. The 3,600-square-foot custom home built by Weiss Building & Development LLC is the first home in Illinois certified to the DOE Challenge Home criteria, which requires that homes meet the EPA Indoor airPlus guidelines.The builder won a 2013 Housing Innovation Award in the custom builder category.

Building America↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers'’ for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field's Metal eutectic alloy with a melting point of 62°C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions. It is recommended that glass vessels of various volumes ranging from 125 mL to 1 gallon with modified tops containing the specified Field's Metal eutectic alloy which are appropriately designed to avoid flashing spray material releases be added to the DSA container list. These vessels will be utilized in the Shielded Cells for the storage of radioactive liquid samples of sludge slurries. Use of these vessels will also be advantageous for other liquid samples containing accountable amounts of nuclear material throughout other SRNL laboratories. Similarly constructed paraffin vessel lids could also potentially be added to the approved list, though additional testing would be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Substrate Engineered Interconnected Graphene Electrodes with Ultrahigh Energy and Power Densities for Energy Storage Applications

Supercapacitors combine the advantages of electrochemical storage technologies like high energy density batteries and high power density capacitors. At 5-10 W h Kg -1 , the energy densities of current supercapacitors are still significantly lower than energy densities of lead acid (20-35 W h Kg -1 ), Ni-metal hydride (40-100 W h Kg -1 ) and Li-ion (120-170 W h Kg -1 ) batteries. Recently, graphene based supercapacitors have shown energy density of 40-80 W h kg -1 . However, their performance is mainly limited due to the reversible agglomeration and restacking of individual graphene layers caused by π-π interactions. The restacking of graphene layers leads to significant decrease of ion-accessible surface area and the low capacitance of graphene based supercapacitors. Here, we introduce a microstructure substrate based method to produce fully delaminated and stable interconnected graphene structure using flash reduction of GO in a few seconds. With this structure, here we achieve the highest amount of volumetric capacitance obtained so far by any type of pure carbon based material. The affordable and scalable production method is capable of producing electrodes with energy density of 0.37 Wh cm -3 and power density of 416.6 W cm -3 . This electrode maintained more than 91 % of its initial capacitance after 5000 cycles. Moreover, combining with ionic liquid, this solvent free graphene electrode material is highly promising for on-chip electronics, micro supercapacitors as well as high power applications.

25 ENERGY STORAGE↗

Flash drive memory apparatus and method

A memory apparatus includes a non-volatile computer memory, a USB mass storage controller connected to the non-volatile computer memory, the USB mass storage controller including a daisy chain component, a male USB interface connected to the USB mass storage controller, and at least one other interface for a memory device, other than a USB interface, the at least one other interface being connected to the USB mass storage controller.

Hinchey, Michael G.↗