Search NASA⌕ Search

SEARCH · Search NASA

Results for “flaw”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A New Merit Function for Evaluating the Flaw Tolerance of Composite Laminates: Arbitrary Size Holes and Center Cracks - Part 2

In a previous paper, a new merit function for determining the strength performance of flawed composite laminates was presented. This previous analysis was restricted to circular hole flaws that were large enough that failure could be predicted using the laminate stress concentration factor. In this paper, the merit function is expanded to include the flaw cases of an arbitrary size circular hole or center crack. Failure prediction for these cases is determined using the point stress criterion. An example application of the merit function is included for a wide range of graphite/epoxy laminates.

Martin, Mikulas M., Jr.↗

Flaw Tolerance in Lap Shear Brazed Joints

Vacuum brazing is a viable process to achieve strong permanent and hermetic joints in space. As in any joining process, brazed Joints have various imperfections and defects. It is important to understand the impact that flaws have on the load carrying capacity and performance of the brazed joints. This study focuses on the behavior of lap shear joints due to their engineering importance in brazed aerospace structures. In Part 1 an average shear strength capabilitY and failure modes of the single lap joints are explored. Specimens comprised of 0.090 inch thick 347 stainless steel sheet brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the measured loads and average shear stresses at failure with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap lengths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. In Part 2, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify if behavior of ductile ]appoints containing flaws is similar to the joints with the reduced braze area. Finally, in Part 3, the results obtained in Part 1 and 2 will be applied to the brazed assembly to evaluate a load carrying capability of the structural lap joint containing defects.

Flom, Yury↗

Flaw Tolerance In Lap Shear Brazed Joints

This paper presents results of the second part of an on-going effort to gain better understanding of defect tolerance in braze joints. In the first part of this three-part series, we mechanically tested and modeled the strength of the lap joints as a function of the overlap distance. A failure criterion was established based on the zone damage theory, which predicts the dependence of the lap joint shear strength on the overlap distance, based on the critical size of a finite damage zone or an overloaded region in the joint. In this second part of the study, we experimentally verified the applicability of the damage zone criterion on prediction of the shear strength of the lap joint and introduced controlled flaws into the lap joints. The purpose of the study was to evaluate the lap joint strength as a function of flaw size and its location through mechanical testing and nonlinear finite element analysis (FEA) employing damage zone criterion for definition of failure. The results obtained from the second part of the investigation confirmed that the failure of the ductile lap shear brazed joints occurs when the damage zone reaches approximately 10% of the overlap width. The same failure criterion was applicable to the lap joints containing flaws.

Wang, Len↗

Deep Flaw Detection with Giant Magnetoresistive (GMR) Based Self-Nulling Probe

In this paper a design modification to the Very-Low Frequency GMR Based Self-Nulling Probe has been presented to enable improved signal to noise ratio for deeply buried flaws. The design change consists of incorporating a feedback coil in the center of the flux focusing lens. The use of the feedback coil enables cancellation of the leakage fields in the center of the probe and biasing of the GMR sensor to a location of high magnetic field sensitivity. The effect of the feedback on the probe output was examined, and experimental results for deep flaw detection were presented. The experimental results show that the modified probe is capable of clearly identifying flaws up to 1 cm deep in aluminum alloy structures.

Wincheski, Buzz↗

Characteristics of Ferromagnetic Flux Focusing Lens in the Development of Surface/Subsurface Flaw Detector

Electromagnetic NDE techniques have in the past steered away from the use of ferromagnetic materials. Although their high permeabilities lead to increased field levels, the properties of ferrous elements in the presence of alternating magnetic fields are difficult to determine. In addition, their use leads to losses which can be minimized through the use of low conductivity ferrites. In fact, the eddy current probes which do incorporate ferromagnetic materials have focused on these losses and the shielding which can be obtained by surrounding a probe with a high permeability, conducting material. Eddy current probes enclosed in conducting and magnetic shields have been used to prevent the generated fields from interacting with materials in the vicinity of the probe, such as when testing near material boundaries. A recent invention has used ferromagnetic shielding to magnetically separate individual concentric eddy current probes in order to eliminate cross-talk between the probes so that simultaneous detection of different types of flaws at different depths can be achieved. In contrast to the previous uses of ferromagnetic materials purely as magnetic shields, an electromagnetic flaw detector recently developed at NASA Langley Research Center takes advantage of the flux focusing properties of a ferromagnetic mild steel in order to produce a simple, effective device for the non-destructive evaluation of conducting materials. The Flux Focusing Eddy Current Probe has been shown to accurately measure material thickness and fatigue damage. The straight forward flaw response of the probe makes the device ideal for rapid inspection of large structures, and has lead to its incorporation in a computer controlled search routine to locate fatigue crack tips and monitor experimental fatigue crack growth experiments.

Wincheski, Buzz↗

Magnetoresistive Flux Focusing Eddy Current Flaw Detection

A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil s longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multi-layer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

Russell A Wincheski↗

Magnetoresistive flux focusing eddy current flaw detection

A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil's longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multilayer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

Wincheski, Russell A.↗

Improved Flaw Detection and Characterization with Difference Thermography

Flaw detection and characterization with thermographic techniques in graphite polymer composites is often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, variations in fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These variations result in a noise floor that increases the difficulty of detecting and characterizing deeper flaws. The paper investigates comparing thermographic responses taken before and after a change in state in a composite to improve the detection of subsurface flaws. A method is presented for registration of the responses before finding the difference. A significant improvement in the detectability is achieved by comparing the differences in response. Examples of changes in state due to application of a load and impact are presented.

Winfree, William P.↗

Determination of Flaw Size and Depth From Temporal Evolution of Thermal Response

Simple methods for reducing the pulsed thermographic responses of flaws have tended to be based on either the spatial or temporal response. This independent assessment limits the accuracy of characterization. A variational approach is presented for reducing the thermographic data to produce an estimated size for a flaw that incorporates both the temporal and spatial response to improve the characterization. The size and depth are determined from both the temporal and spatial thermal response of the exterior surface above a flaw and constraints on the length of the contour surrounding the delamination. Examples of the application of the technique to simulation and experimental data acquired are presented to investigate the limitations of the technique.

Winfree, William P.↗

Electronic flaw simulator for eddy current probe calibration

Electronic flaw simulator cycled into the eddy current system eliminates errors in probe calibration. A discrimination level reference established in the probe permits recognition of those flaws in materials with an equivalent volume equal to or greater than the reference.

Almasy, L. J.↗

Investigation of flaw geometry and loading effects on plane strain fracture in metallic structures

The effects on fracture and flaw growth of weld-induced residual stresses, combined bending and tension stresses, and stress fields adjacent to circular holes in 2219-T87 aluminum and 5AI-2.5Sn(ELI) titanium alloys were evaluated. Static fracture tests were conducted in liquid nitrogen; fatigue tests were performed in room air, liquid nitrogen, and liquid hydrogen. Evaluation of results was based on linear elastic fracture mechanics concepts and was directed to improving existing methods of estimating minimum fracture strength and fatigue lives for pressurized structure in spacecraft and booster systems. Effects of specimen design in plane-strain fracture toughness testing were investigated. Four different specimen types were tested in room air, liquid nitrogen and liquid hydrogen environments using the aluminum and titanium alloys. Interferometry and holograph were used to measure crack-opening displacements in surface-flawed plexiglass test specimens. Comparisons were made between stress intensities calculated using displacement measurements, and approximate analytical solutions.

Hall, L. R.↗

Bonded panel, flaw detection standards

With optical holography or ultrasonic equipment, process prepares standards for use in detection of flaws in bonded panels. Metal-to-metal, composite-to-metal, and composite-to-composite flaw standards have been produced by this process, and all have been used and tested successfully.

Platt, R. J., Jr.↗

Acoustic-emission signal-processing analog unit for locating flaws in large tanks

Technique monitors structural flaws in 105-in. diameter tanks. Tank surface is divided into many areas and each area is sectioned into 20 equilateral triangles that form icosahedron. Twelve transducers are equally positioned on tank surface at vertex of each triangle. Transducers monitor area for flaws by detecting any increase in acoustical activity.

Moskal, F. J.↗

Flaw growth behavior in thick welded plates of 2219-T87 aluminum at room and cryogenic temperatures

Axial load fatigue and fracture tests were conducted on thick welded plates of 2219-T87 aluminum alloy to determine the tensile strength properties and the flaw growth behavior in electron beam, gas metal arc, and pulse current gas tungsten arc welds for plates 6.35 centimeters (2.5 in.) thick. The tests were conducted in room temperature air and in liquid nitrogen environments. Specimens were tested in both the as-welded and the aged after welding conditions. The experimental crack growth rate were correlated with theoretical crack growth rate predictions for semielliptical surface flaws.

Forman, R. G.↗

Fracture initiation and propagation in a cylindrical shell containing an initial surface flaw

An attempt is made to provide the necessary analytical tools for the application of two different types of fracture criteria to shell structures. Of particular interest is the problem of fracture propagation and arrest in a cylindrical pressure vessel containing an initial surface flaw. It is assumed that the flaw has the most unfavorable geometry and orientation, namely, it is a crack lying on a meridional plane. Stress intensity factor for a part-through crack, and a surface or internal crack with a fully yielded net ligament are considered. Attention is given to constant delta curves for depressurization studies and to depressurization and crack arrest in pressure vessels.

Erdogan, F.↗

The effect of initial flaw configuration on leak critical pressure vessel design

The effect of initial flaw shape and depth on the cycles required to produce a pressure leak condition in parent and welded 2219-T87 aluminum was examined for thicknesses from 0.04 to 0.3 inch. Initial flaw aspect ratios of 0.5, 0.3, and 0.15 were examined for tests conducted at a frequency of 4 Hz at room temperature and at 300 F. A computer program developed by Forman was used to predict the cycles to leak curve as a function of initial crack aspect ratio, material thickness, and specimen type and the results compared with the experimental data. Sources of error in the crack propagation analysis and the interface with NDI capabilities are discussed.

Pettit, D. E.↗

Analysis and Test of Deep Flaws in Thin Sheets of Aluminum and Titanium. Volume 1: Program Summary and Data Analysis

Six thicknesses of 2219-T87 aluminum base metal surface flaw and center crack specimens ranging from 9.53 to 0.635 mm (0.375 to 0.025 inch) were tested at temperatures ranging from 295K to 20K. Additionally, 6A1-4V STA titanium base metal specimens were tested in three thicknesses 3.18, 2.03, and 1.02 mm (0.125, 0.080 and 0.040 inch) at room temperature. All tests were conducted on uniaxial specimens. Results were analyzed and compared with previously developed data to establish a criterion for proof testing thin walled pressure vessels. The data analysis and exact flaw size dimensions are presented.

Finger, R. W.↗