Search NASA⌕ Search

SEARCH · Search NASA

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Groups and the Entropy Floor: XMM-Newton Observations of Two Groups

Using XMM-Newton spatially resolved X-ray imaging spectroscopy we obtain the temperature, density, entropy, gas mass, and total mass profiles for two groups of galaxies out to approximately 0.3 R(sub vir)(R(sub vir), the virial radius). Our density profiles agree well with those derived previously, and the temperature data are broadly consistent with previous results but are considerably more precise. Both of these groups are at the mass scale of 2x10(exp 13) M(solar mass), but have rather different properties. Both have considerably lower gas mass fractions at r < 0.3 R(sub vir), than the rich clusters. NGC2563, one of the least luminous groups for its X-ray temperature, has a very low gas mass fraction of approximately 0.004 inside 0.1 R(sub vir), which increases with radius. NGC4325, one of the most luminous groups at the same average temperature, has a higher gas mass fraction of 0.02. The entropy profiles and the absolute values of the entropy as a function of virial radius also differ, with NGC4325 having a value of approximately 100 keV cm(exp -2) and NGC2563 a value of approximately 300 keV cm(exp -2) at r approximately 0.1 R(sub vir). For both groups the profiles rise monotonically with radius and there is no sign of an entropy 'floor'. These results are inconsistent with pre-heating scenarios that have been developed to explain a possible entropy floor in groups, but are broadly consistent with models of structure formation that include the effects of heating and/or the cooling of the gas. The total entropy in these systems provides a strong constraint on all models of galaxy and group formation, and on the poorly defined feedback process that controls the transformation of gas into stars and thus the formation of structure in the universe.

Mushotzky, R. F.↗

Validating Ancient Age of the Buried Floor of the Northern Lowlands, Mars

Hesperian and Amazonian plains units cover the northern lowlands but little is known about what this surface covers. Models for the creation of the lowlands and the dichotomy boundary implement mechanisms which vary from internal processes, such as plate tectonics or first-order mantle convection, to external processes, such as a single large impact or multiple impacts. Different models require different time scales for low-land formation; determining the age of the buried low-land surface would help constrain the formation models. The Mars Orbiting Laser Altimeter (MOLA) has yielded a high-precision, topographic gridded data set that reveals the presence of Quasi-Circular Depressions (QCDs) in both the southern highlands and the northern lowlands. Most of these roughly circular depressions have no corresponding visible structural feature on the surface. It is proposed that these QCDs are the surface representation of buried impact craters. Based on this assumption, cumulative number vs. diameter curves were constructed, which placed the age of the buried surface of the northern lowlands in the Early or pre-Noachian. A Noachian basement is supported by the remnants of large craters and multi-ring basins discovered in earlier research, but the QCDs provide the first evidence of this for the entire lowland. Constraining the age of the basement floor to the earliest Noachian, however, would require that the process that formed the northern lowlands either occurred in the early Noachian or involves removal of material from the bottom of the crust without destroying the previously formed craters to achieve the modeled crustal thinning. But can we establish that the QCDs do in fact represent buried impact craters, and thus validate an Early Noachian age for the buried lowland floor?

Buczkowski, D. L.↗

Finite Element Models and Properties of a Stiffened Floor-Equipped Composite Cylinder

Finite element models were developed of a floor-equipped, frame and stringer stiffened composite cylinder including a coarse finite element model of the structural components, a coarse finite element model of the acoustic cavities above and below the beam-supported plywood floor, and two dense models consisting of only the structural components. The report summarizes the geometry, the element properties, the material and mechanical properties, the beam cross-section characteristics, the beam element representations and the boundary conditions of the composite cylinder models. The expressions used to calculate the group speeds for the cylinder components are presented.

Grosveld, Ferdinand W.↗

The Walk on Floor Eyes Closed Tandem Step Test as a Quantitative Measure of Ataxia After Space Flight

INTRODUCTION Posture and locomotion are among the functions most affected by space flight. Postflight ataxia can be quantified easily by using the walk on the floor line test with the eyes closed (WOFEC). Data from a modified WOFEC were obtained as part of an ongoing interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate both postflight functional performance of astronauts and related physiological changes. METHODS Five astronauts with flight durations of 12 to 16 days participated in this study. Performance measurements were obtained in 2 preflight sessions, on landing day, and 1, 6, and 30 days after landing. The WOFEC test consisted of walking with the feet placed heel to toe in tandem, arms folded across the chest and eyes closed, for 10 steps. A trial was initiated after the eyes were closed and the front foot was aligned with the rear foot. The performance metric was the average percentage of correct steps completed over 3 trials. A step was not counted as correct if the crewmember sidestepped, opened eyes, or paused for more than 3 seconds between steps. Step accuracy was scored independently by 3 examiners. RESULTS Immediately after landing subjects seemed to be unaware of their foot position relative to their body or the floor. The percentage of correct steps was significantly decreased on landing day. Partial recovery was observed the next day, and full recovery to baseline on the sixth day post landing. CONCLUSION These data clearly demonstrate the sensorimotor challenges facing crewmembers after they return from space flight. Although this simple test is intended to complement the FTT battery of tests, it has some stand-alone value as it provides investigators with a means to quantify vestibular ataxia as well as provide instant feedback on postural stability without the use of complex test equipment.

Fisher, E. A.↗

Walk on Floor Eyes Closed Test as a Measure of Postflight Ataxia

INTRODUCTION: Astronauts returning from space flight universally exhibit impaired posture and locomotion. Measurement of this impairment is an evolving process. The walk on the floor line test with the eyes closed (WOFEC) provides a unique procedure for quantifying postflight ataxia. Data from a modified WOFEC were obtained as part of an ongoing NASA interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate astronaut postflight functional performance. METHODS: Seven astronauts (5 short duration with flights of 12-16 days; 2 long duration crewmembers with flights of 6 months) were tested twice before flight, on landing day (short duration only), and 1, 6, and 30 days after flight. The WOFEC consisted of walking for 10 steps (repeated twice) with the feet heel to toe in tandem, arms folded across the chest and the eyes closed. The performance metric (scored by three examiners from video) was the percentage of correct steps completed over the three trials. A step was not counted as correct if the crewmember sidestepped, opened their eyes, or paused for more than three seconds between steps. RESULTS/ CONCLUSIONS: There was a significant decrease in percentage of correct steps on landing day (short duration crew) and on first day following landing (long duration) with partial recovery the following day, and full recovery beginning on day sixth after flight. Both short and long duration fliers appeared to be unaware of foot position relative to their bodies or the floor. Postflight, deviation from a straight path was common, and the test for two crewmembers elicited motion sickness symptoms. These data clearly demonstrate the sensorimotor challenges facing crewmembers after returning from spaceflight. The WOFEC test has value providing the investigator or crew surgeon with a simple method to quantify vestibular ataxia, as well as providing instant feedback of postural ataxia without the use of complex test equipment.

Reschke, M. F.↗

Walk on Floor Eyes Closed Test: A Unique Test of Spaceflight Induced Ataxia

Measurement and quantification of posture and locomotion following spaceflight is an evolving process. Based on the data obtained from the current investigation we believe that the walk on the floor line test with the eyes closed (WOFEC) provides a unique procedure for quantifying postflight ataxia. As a part of an ongoing investigation designed to look at functional changes in astronauts returning from spaceflight seven astronauts (5 short duration with flights of 12-16 days; 2 long duration crewmembers with flights of 6 months) were tested twice before flight, on landing day (short duration only), and 1, 6, and 30 days after flight. The WOFEC consisted of walking for 10 steps (repeated twice) with the feet heel to toe in tandem, arms folded across the chest and the eyes closed. The performance metric (scored by three examiners from video) was the percentage of correct steps completed over the three trials. A step was not counted as correct if the crewmember side-stepped, opened their eyes, or paused for more than three seconds between steps. The data reveled a significant decrease in percentage of correct steps on landing day (short duration crew) and on the first day following landing (long duration) with partial recovery the following day, and full recovery beginning on day sixth after flight. Both short and long duration fliers appeared to be unaware of foot position relative to their bodies or the floor. Postflight, deviation from a straight path was common, and seemed to be determined by the angle of foot placement relative to their body. While deviation from a straight line could be either left or right, primary deviations were observed to occur to the right. Furthermore, the test for two crewmembers elicited motion sickness symptoms. These data clearly demonstrate the sensorimotor challenges facing crewmembers after returning from spaceflight. The WOFEC test has value providing the investigator or crew surgeon with a simple method to quantify vestibular ataxia, as well as providing instant feedback of postural ataxia without the use of complex test equipment.

Reschke, M. F.↗

Pyroclastic Deposits in Floor-Fractured Craters: A Unique Style or Lunar Basaltic Volcanism?

The lunar maria were formed by effusive fissure flows of low-viscosity basalt. Regional pyroclastic deposits were formed by deep-sourced fire-fountain eruptions dominated by basaltic glass. Basaltic material is also erupted from small vents within floor-fractured impact craters. These craters are characterized by shallow, flat floors cut by radial, concentric and/or polygonal fractures. Schultz [1] identified and classified over 200 examples. Low albedo pyroclastic deposits originate from depressions along the fractures in many of these craters.

Allen, Carlton C.↗

Frequency comparisons via GPS carrier-phase: jump processing, temperature compensation and zero/short-baseline noise-floors

GPS carrier-phase receivers have been used to produce high quality time/frequency comparisons between clocks and frequency standards. Current ways of processing the carrier-phase data, however, result in phase jumps and data gaps that make the data difficult to use effectively and repeatedly for long datasets. In addition, temperature fluctuations generally perturb receiver output detrimentally. We describe the steps of a simple but effective automated algorithm for comparing frequencies that can compensate for data gaps, day boundary jumps, and other phase jumps as well as for temperature disturbances. We describe process features and focus on zero-baseline noise-floors, measuring Allan deviations of the Deep Space Atomic Clock mission’s receiver down to 1x10-17 at 5x105 seconds, with an upper confidence level of 3x10-17. The zero-baseline noise floors we present give confidence in our algorithm and temperature compensation’s robustness.

Diener, William A.↗

Full Scale Flat Floor Testing of a 500-M2-Class Solar Sail Deployer

Solar sailing missions rely on deployable systemsfor large area to mass ratios once in space, whilestill being small enough for launcher envelopes inthe stowed configuration. Many of thesedeployable systems feature booms that areflattened and subsequently coiled onto aspool/hub. As part of a collaborative deployablespace structures research effort of NASA and DLR,a boom deployment mechanism for a future 500 m²solar sail has been developed since 2017. To achieve the respective solar sail size goal, 16.5m long booms produced by NASA were integratedinto a DLR-designed deployer mechanism. Thisconsiderable size, as well as the lightweightconstruction of the booms and respectivedeployable systems makes ground testing asignificant challenge. Some systems for gravitycompensation and boom alignment will bepresented in the paper. However, the main focus isthe functional flat floor testing of the integratedboom-deployment mechanism system, as well asits challenges. The testing performed includes full deployment aswell as stowage of the booms. Both have beenperformed multiple times. The latter is one of thekey parameters determining packaging efficiency,which in turn confirms design assumptions. Duringsystem development, small scale tests and modelshave been used in preparation of flat floor testingof the 33 m span cross of the full-scale booms anddeployment mechanism. Hence a small chapter isalso devoted to analysing the differences inbehaviour between small- and full-scaledeployment systems. More parameters that are vital to design decisionshave been determined this way, such as drivingbelt force or hub brake torque. This paper alsofocuses on development goals and needs forfuture steps to achieve higher levels of technologyreadiness, such as the balancing of driving motorforce, synchronisation of its transmission and thecountering hub brake torque

Deployment mechanism↗

ResStock Measure Documentation: Attic Floor Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Attic Floor Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimation of Moisture Content of Forest Canopy and Floor from SAR Data Part I: Volume Scattering Case

To understand and predict the functioning of forest biomes, their interaction with the atmosphere, and their growth rates, the knowledge of moisture content of their canopy and the floor soil is essential. The synthetic aperture radar on airborne and spaceborne platforms has proven to be a flexible tool for measuring electromagnetic back- scattering properties of vegetation related to their moisture content.

Forest Canopy moisture content forest floor synthe↗

Floor and ceiling effects in the EORTC QLQ-C30 Physical Functioning subscale among patients with advanced or metastatic breast cancer

The European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire Core 30 Physical Functioning subscale is a widely used patient-reported outcome measure that quantifies cancer patients' physical functioning. Strong floor/ceiling effects can affect a scale's sensitivity to change. The aim of this study was to characterize floor/ceiling effects of the physical functioning domain in patients with advanced/metastatic breast cancer enrolled in commercial clinical trials and a community-based trial. The clinical trial cohort comprised patients from 5 registrational trials submitted to the Food and Drug Administration for review (2010-2017). The community cohort comprised a subgroup of patients from the Alliance Patient Reported Outcomes to Enhance Cancer Treatment (PRO-TECT) trial. The distribution of patient responses to Physical Functioning items and the summed score were assessed at the baseline and 3-month follow-up for both cohorts. Descriptive statistics were used to determine floor/ceiling effects at the item and scale levels. The clinical trial cohort and the community cohort consisted of 2407 and 178 patients, respectively. Twenty-four percent or more of the respondents reported “not at all” for having trouble/needing help with each Physical Functioning item across both cohorts and measurement time points. Fourteen to twenty percent of the patients scored perfectly (100 of 100) on the Physical Functioning subscale summary measure (where higher scores indicated better physical functioning) across both cohorts and time points. Minor floor effects and notable ceiling effects were found at the item and scale levels of the Physical Functioning subscale, regardless of cohort, and this creates some uncertainty about its ability to detect changes in physical functioning among high-functioning patients. In conclusion, investigators may consider adding additional high-functioning items from the EORTC's item library to more accurately describe the impact of anticancer treatment on patients' physical functioning.

60 APPLIED LIFE SCIENCES↗

Servomotor-driven leveling elements for machine tool frame-to-floor alignment

This paper presents the results of aligning the frame to concrete floor of a large 5-axis machine tool by leveling element adjustments using servomotors instead of manual operation. The machine tool leveling elements used in this study are mechanical devices that attach the machine tool frame to the concrete foundation. These leveling elements are also adjustable so that each location along the machine tool can be uniquely adjusted such that the geometric errors of the frame are minimized, and the accuracy of the machine tool is improved. Off-the-shelf servomotors and connection equipment were installed at each of 12 leveling element locations for a precision 5-axis machine tool at Oak Ridge National Laboratory. The servomotors allow a technician to align the machine tool frame remotely, instead of crawling under the machine tool to iteratively manually adjust each of the 12 leveling elements. The open-loop servomotor-leveling element system design is presented in this paper as well as machine tool frame alignment results. The servomotor system significantly reduces leveling element adjustment time, eliminates the need for under-machine access, reduces technician physical strain, and significantly improves the adjustment repeatability.

Honeycutt, Andrew [ORNL]↗

Portable Tank Storage Pit Technical Documents and Associated Flooring Documents

The work performed under this section includes the surface preparation and application of protective floor coatings; furnishing all labor, materials, and equipment necessary to perform all operations in connection with the application required for satisfactory completion in accordance with the standards and practices set forth herein.

99 GENERAL AND MISCELLANEOUS↗

Impact of intense sanitization procedures on bacterial communities recovered from floor drains in pork processing plants

Pork processing plants in the United States (US) cease operations for 24–48 h every six or twelve months to perform intense sanitization (IS) using fogging, foaming, and further antimicrobial treatments to disrupt natural biofilms that may harbor pathogens and spoilage organisms. The impact such treatments have on short-term changes in environmental microorganisms is not well understood, nor is the rate at which bacterial communities return. Swab samples were collected from floor drains to provide representative environmental microorganisms at two US pork processing plants before, during, and after an IS procedure. Samples were collected from four coolers where finished carcasses were chilled and from four locations near cutting tables. Each sample was characterized by total mesophile count (TMC), total psychrophile count (TPC), and other indicator bacteria; their biofilm-forming ability, tolerance of the formed biofilm to a quaternary ammonium compound (300 ppm, QAC), and ability to protect co-inoculated Salmonella enterica. In addition, bacterial community composition was determined using shotgun metagenomic sequencing. IS procedures disrupted bacteria present but to different extents depending on the plant and the area of the plant. IS reduced TPC and TMC, by up to 1.5 Log 10 CFU only to return to pre-IS levels within 2–3 days. The impact of IS on microorganisms in coolers was varied, with reductions of 2–4 Log 10 , and required 2 to 4 weeks to return to pre-IS levels. The results near fabrication lines were mixed, with little to no significant changes at one plant, while at the other, two processing lines showed 4 to 6 Log 10 reductions. Resistance to QAC and the protection of Salmonella by the biofilms varied between plants and between areas of the plants as well. Community profiling of bacteria at the genus level showed that IS reduced species diversity and the disruption led to new community compositions that in some cases did not return to the pre-IS state even after 15 to 16 weeks. The results found here reveal the impact of using IS to disrupt the presence of pathogen or spoilage microorganisms in US pork processing facilities may not have the intended effect.

59 BASIC BIOLOGICAL SCIENCES↗