At least 73 records · Page 4

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Personal and environmental predictors of polycyclic aromatic hydrocarbon exposure identified through repeated silicone wristband sampling

This study integrates quantitative data on personal exposure to polycyclic aromatic hydrocarbons (PAHs) in 162 silicone wristbands with demographics, behavioral information, and housing characteristics to explore contributions to residential exposure in a superfund-adjacent community over the course of a year. Forty-six residents completed questionnaires and wore silicone wristbands as personal passive samplers for seven consecutive days on up to four separate occasions in alternating months between November 2022 and June 2023. It was hypothesized that individual behaviors and housing characteristics are sources of dependence and correlation between personal PAH exposures. 50 PAHs were detected at least once, 17 of which were alkylated PAHs. Exposure to PAHs of similar molecular weight was often correlated, notably between naphthalenes (2-rings) and higher molecular weight PAHs (3 or more rings). Generalized linear mixed models identified flooring type, participant age, and sampling month as important predictors of increased PAH exposure, and flooring type, and use of wood stoves or heavy machinery as predictors of increased naphthalene exposure relative to higher molecular weight PAHs. Individual chemical models based on concentration data and detection frequencies corroborated these findings across multiple PAHs. We demonstrate that personal exposure is not static and the degree of variability in personal exposure is individual. Hence, identification of influential exposure factors through repeated measures of chemical exposure and characterization of variability in personal exposure as performed in this study, is important in the development of exposure mitigation strategies.

Bonner, Emily↗

A tutorial on the micro-trench technique for incident ion angle, material erosion, and impurity deposition measurements at plasma-facing surfaces

The micro-trench method is a new technique to measure polar and azimuthal incident ion angles, material erosion, and impurity deposition at plasma-facing surfaces, and has been applied in the DIII-D divertor. This article gives a tutorial of the micro-trench technique consisting of six steps: (1) micro-trench fabrication, (2) pre-exposure measurement of the fabricated micro-trench geometry, (3) tracer material deposition, (4) plasma exposure, (5) post-exposure observation of the tracer material, and (6) post-exposure measurement of the micro-trench geometry. Two criteria need to be satisfied to apply the micro-trench method successfully: (i) uniform impurity deposition on the micro-trench floor, and (ii) erosion dominated by the physical sputtering induced by the impinging ions. Furthermore, when those two criteria are satisfied, post-exposure analysis of the impurity deposition patterns on the micro-trench floor may be used to determine the polar and azimuthal incident ion directions (mean values of the ion angle directions), erosion rate, and impurity deposition rate during plasma exposure without computational interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Logistic classification for tool life modeling in machining

This paper describes the application of logistic classification for tool life modeling and prediction in an industrial setting using shop floor data. Tool life is treated as a classification problem since tool wear can only be measured at the time of tool replacement in a production environment. Laboratory tool wear experiments are used to simulate shop floor wear data by two states: not worn (class 0); and worn (class 1). To incorporate non-linearity in logistic classification, a log-transformation of input features is performed. The logistic classification approach, results, and interpretability of the logistic model are presented.

Karandikar, Jaydeep↗

A legacy of fire emerges from multiple disturbances to most shape microbial and nitrogen dynamics in a deciduous forest

Healthy forests are vital components of terrestrial ecosystems for their raw materials, high biodiversity, cycling of nutrients, and potential to sequester carbon. However, these ecosystems are sensitive to disturbances, and anthropogenic activities pose a serious threat to forest ecosystems globally. For example, human activities have dramatically altered multiple historical disturbance regimes in forests, including suppressing fire, increasing the density of large herbivores, and reducing the size of canopy gaps, among other disturbances. Such disturbances can have dramatic impacts on microbially-mediated forest soil functions, but more research is needed to determine the collective impacts of these disturbances. In this study, we investigated the interactive effects of disturbances, namely the legacies of fire, large herbivore densities, and canopy gap creation, in a deciduous forest soil. We determined that forest floor and mineral soil carbon and nitrogen pools were shaped by multiple disturbances, but fire was more influential than the other disturbances. The abundance of several functionally-relevant microbial taxa were significantly impacted by fire, and the effect was more pronounced in the mineral soil than in the forest floor. Together, these findings demonstrate that multiple disturbances, especially a legacy of fire, exerts long-term control over soil carbon, nitrogen and microbial dynamics in a deciduous forest system.

59 BASIC BIOLOGICAL SCIENCES↗

The Short Life of Upvalley Wind in a High‐Altitude Valley in the Colorado Rocky Mountains

Thermally driven upvalley (UV) wind in the upper East River Valley in the Colorado Rocky Mountains often unexpectedly stops in midmorning and reverses back to downvalley (DV) wind. We use a comprehensive observational data set for a nearly two‐year long period to analyze the wind system and boundary layer evolution in this high‐altitude valley and determine the reason for this early wind reversal. Days with short UV wind predominantly occur during the warm season when the valley floor is free of snow and the convective boundary layer (CBL) grows well above the height of the surrounding ridges. UV wind persists throughout the day only on a few days during the warm season. We link differences in valley wind evolution to wind direction at upper levels at and above ridge height and propose forced channeling mechanisms to describe coupling between valley and upper‐level wind when the CBL grows above ridge height. The frequency distribution of upper‐level wind direction is such that channeling in the DV direction is favored, which explains the predominance of days with short UV wind. The deep CBL is supported by the presence of a deep weakly stably stratified residual layer with high aerosol content, which is regularly present over the mountain range during the warm season. On days when the CBL does not grow above ridge height, for example, when the valley floor is covered by snow, thermally driven UV wind is able to persist throughout the day independent of upper‐level wind direction.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the Passive Cooling Potential of Thermal Mass Inherent in Medium to Large Commercial Buildings

Typical commercial construction inherently contains large surface areas of relatively thin mass located in the floor slabs. This research asks how effective this mass could be for passive cooling, relative to other mass depths, if it were to be exposed and used as thermal mass. Although much of the rich literature on thermal mass has been conducted with far greater mass depths, a more limited amount of research suggests that because the surface heat transfer rate is limited, the focus should be on the surface area of exposed mass, not its depth. This presents an opportunity for more buildings to behave more thermally massively, if the mass inherent in typical floor slabs contains utility, particularly over diurnal cycles. In all climates analyzed, it was found that there is a pronounced shoulder where energy savings from passive cooling of increasing mass depths was steep until roughly 7.5–10 cm, and beyond this point the achieved energy savings diminished rapidly. When considering the embodied energy of concrete, the incremental benefit of added mass beyond a typical topping slab of 10 cm does not justify the incremental embodied energy cost from a total energy standpoint alone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Characteristics of Multistory Buildings

In order to evaluate unit stresses or to estimate possible damage in multistory buildings from earthquake or ground motion from underground nuclear explosion it is essential to determine how much of the dynamic response at any level is due to various types of freedom. The effects of shear deformation between floors, joint rotation, over-all flexure, and ground compliance are considered. Joint rotation and over-all flexure are evaluated over a wide range of building characteristics with simply determined indices. Further, a period synthesis concept and a pseudo-stiffness procedure are proposed to enable the determination of periods, mode shapes and stiffnesses with consideration of joint rotation, over-all flexure and ground compliance while performing simple labor-saving analyses for assumed rigid-floor shear buildings. The first three modes of vibration are considered in elastic free vibration. The buildings and models are symmetric in plan without torsional coupling.

42 ENGINEERING↗

Alcove formation in dissolving cliffs driven by density inversion instability

We demonstrate conditions that give rise to cave-like features commonly found in dissolving cliffsides with a minimal two-phase physical model. Alcoves that are wider at the top and tapered at the bottom, with sharp-edged ceilings and sloping floors, are shown to develop on vertical solid surfaces dissolving in aqueous solvents. As evident from descending plumes, sufficiently large indentations evolve into alcoves as a result of the faster dissolution of the ceiling due to a solutal Rayleigh–Bénard density inversion instability. In contrast, defects of size below the boundary layer thickness set by the critical Rayleigh number smooth out, leading to stable planar interfaces. Furthermore, the ceiling recession rate and the alcove opening area evolution are shown to be given to first-order by the critical Rayleigh number. By tracking passive tracers in the fluid phase, we show that the alcoves are shaped by the detachment of the boundary layer flow and the appearance of a pinned vortex at the leading edge of the indentations. The attached boundary layer past the developing alcove is then found to lead to rounding of the other sides and the gradual sloping of the floor.

58 GEOSCIENCES↗

Demonstration of a two-dimensional divertor Thomson scattering system on DIII-D

Recent upgrades providing two-dimensional divertor Thomson scattering (DTS-2D) measurements of T e and n e during a DIII-D plasma shot and a thorough description of system components and their functionality are presented. This system expands the capabilities of the existing single divertor Floor measurement location by introducing seven additional laser beam path options in the poloidal plane, spanning major radii from 1.062 to 1.335 m. The system redirects ~1 J, 50 Hz Nd:YAG laser pulses to the new beam paths within 20 ms, stepping through each path on the divertor Floor every 200 ms during a plasma shot. The laser is redirected using an ex-vessel, fast-steering mirror to one of eight in-vessel beam paths oriented underneath the vessel tiles. Up to eleven measurement positions per beam path, from –1.35 to –1.13 m below the machine midplane, are available by dynamically refocusing the ex-vessel collection fiber array using a high-speed linear stage. As a result, current measurement positions above the divertor Shelf are retained via a hole in the fixed, in-vessel mirror, allowing laser pass through.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the LCLS-II Cryogenic Distribution System

The LINAC Coherent Light Source II (LCLS-II) located at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA, is a U.S. Department of Energy project tasked to design and build a world-class x-ray free-electron laser facility for scientific research. The Linac has superconducting radio frequency cryomodules that are connected to the cryogenic plant by the Cryogenic Distribution System (CDS), which consists of distribution boxes with heat exchangers and reliefs, feed caps, end caps, and surface, vertical, and bypass transfer lines. The CDS components were designed and built to specification by industry. The components have been delivered and their installation at SLAC will be discussed. The as-built relief system design will be presented, showing minimization of relief inlet pressure drops while meeting capacity requirements. The relieving flow pressure drops along the lengths of the CDS to centrally located reliefs at the distribution box were analysed to satisfy Pressure Vessel and Process Piping Code criteria to ensure relief performance. The sub-atmospheric 2 K circuit relieving approach will be discussed, which includes a three-way diverter isolation valve suitable for sub-atmospheric service. The component anchoring load design approach and installation into concrete floor will be discussed. This addresses loading, including seismic loading, along the component’s load path to floor anchoring system.

43 PARTICLE ACCELERATORS↗

Effect of quasiperiodic and random noise on many-body dynamical decoupling protocols

Symmetries (and their spontaneous rupturing) can be used to protect and engender novel quantum phases and lead to interesting collective phenomena. In the work of K. Agarwal and I. Martin, the authors described a general dynamical decoupling (polyfractal) protocol that can be used to engineer multiple discrete symmetries in many-body systems. This work expands on the former by studying the effect of quasiperiodic and random noise on such a dynamical scheme. We find generally that relaxation of engineered symmetry generators proceeds by (i) an initial relaxation on microscopic timescales to a prethermal plateau whose height is independent of noise, (ii) a linear relaxation regime with a noise-dependent rate, followed by (iii) a slow logarithmic relaxation regime that is only present for quasiperiodic noise. We glean the essential features of these regimes via scaling collapses and show that they can be generally explained by the spectral properties of the various noise waveforms considered. In particular, the quasiperiodic noise is characterized by highly time-dependent spectrum with a noise floor that mimics white noise, and peaks that grow sharper with time. We argue that both the noise floor and peaks contribute to the initial linear-in-time relaxation while the logarithmic regime is initiated when the peaks become sufficiently well resolved and cease to contribute to further relaxation. Here, we provide numerical evidence to justify these findings.

74 ATOMIC AND MOLECULAR PHYSICS↗

Numerical Improvements in Magnetohydrodynamic, Pulsed Power Simulations of Near-Target Plasmas

Magnetohydrodynamic (MHD) simulations of pulsed power experiments frequently result in unphysical runaway heating when extended to low values of mass density. Traditionally, this has been addressed by the use of conductivity floors below which the plasma is given an arbitrarily low conductivity value. Here, a low-density treatment is presented that allows for low-density material to carry current while maintaining a stable temperature. This treatment is implemented in the Ares multiphysics code. Numerical modifications to the conventional vacuum treatment include an energy-conserving density floor, a modified averaging procedure to determine the thermal conductivity at the edge of adjacent zones, and a modified averaging procedure for determining the thermal conductivity in mixed zones that contain material from differing regions. Additionally, anomalous resistivity and Bohm diffusion models are implemented as simplified models for microphysics-induced enhancement of collisional transport. Importantly, the advantage of these various improvements are illustrated in a simple 1-D pulsed power target where the combined changes result in stable temperatures within the lower density regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared thermography NDT for in-situ defect detection in sandwich composite panel manufacturing

Composite manufacturing presents numerous challenges, as defects can arise from various sources throughout the process. In sandwich composite structures, the integration of a foam core introduces additional complexity and increases the likelihood of defect formation like delamination. To mitigate these issues and reduce the risk of future structural failures, in-situ monitoring during manufacturing is essential. This study investigates infrared (IR) thermography as a non-destructive technique for detecting manufacturing defects in foam-core sandwich composite panels under thermally excited conditions representative of in-situ processing. A stationary FLIR A8590 IR camera (640 × 512 pixels, 30Hz, 17mm lens, 9 ft stand-off distance) was used to monitor prefabricated panels subjected to controlled external heating simulating compression molding and resin cure exotherm. Interlaminar delamination defects with characteristic sizes ranging from 0.25 × 0.25in² to 5 × 5in² produced measurable surface temperature depressions of approximately 4–10°C during transient cooling, exceeding the effective noise floor of the camera by more than two standard deviations. Thicker laminates exhibited prolonged defect detectability windows due to increased thermal diffusion time. In contrast, embedded Teflon inclusions generated weak thermal contrasts of ≤ 3°C, approaching the measurement noise floor, due to limited thermal property contrast with the surrounding glass fiber composite. These results establish quantitative detectability limits for stationary thermographic inspection of sandwich composite panels under manufacturing-representative thermal cycles.

Barakat, Abdallah [ORNL] (ORCID:0000000296141398)↗

Compositionally and density stratified igneous terrain in Jezero crater, Mars

Before Perseverance, Jezero crater’s floor was variably hypothesized to have a lacustrine, lava, volcanic airfall, or aeolian origin. SuperCam observations in the first 286 Mars days on Mars revealed a volcanic and intrusive terrain with compositional and density stratification. The dominant lithology along the traverse is basaltic, with plagioclase enrichment in stratigraphically higher locations. Stratigraphically lower, layered rocks are richer in normative pyroxene. The lowest observed unit has the highest inferred density and is olivine-rich with coarse (1.5 millimeters) euhedral, relatively unweathered grains, suggesting a cumulate origin. This is the first martian cumulate and shows similarities to martian meteorites, which also express olivine disequilibrium. Alteration materials including carbonates, sulfates, perchlorates, hydrated silicates, and iron oxides are pervasive but low in abundance, suggesting relatively brief lacustrine conditions. Orbital observations link the Jezero floor lithology to the broader Nili-Syrtis region, suggesting that density-driven compositional stratification is a regional characteristic.

79 ASTRONOMY AND ASTROPHYSICS↗

Research on Deformation Law of Deep Foundation Pit of Station in Core Region of Saturated Soft Loess Based on Monitoring

Saturated soft loess has a large pore structure, high compressibility, low strength, fluid plastic state, and poor engineering properties. It is still one of the key problems that engineering needs to solve. In order to study the influence of deep foundation pit excavation in the saturated soft loess area on the deformation of foundation pits, the deformation laws of ground settlement, enclosure structure, and supporting axial force were clarified based on the field tests on the deformation characteristics of deep foundation pits in areas with the high-water level in saturated soft loess, combined with geological conditions and on-site construction procedures. The results indicate the following: water supply and construction process were found to be the main factor in changing the surface settlement curve of deep foundation pits in saturated soft loess; increasing the construction speed of the pit bottom floor, inverted braces, floor frame beams, and sidewall frame beams to close the structure, which is conducive to restraining the deformation of the continuous underground wall and foundation pits in similar areas. In the initial stage of support layout, the axial force of steel support tends to increase too fast or even exceed the standard control value. Therefore, a reasonable preadding axial force is an effective means to control the deformation of the continuous underground wall and the axial force of the steel support. The current research results may provide a reference for constructing deep foundation pits in similar areas.

Wang, Xueyan↗

Model America - data and models of every U.S. building

The 5-year goal of the 'Model America' concept was to generate a model of every building in the United States. This data repository delivers on that goal. Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM). There were 125,714,640 buildings detected in the United States and this dataset contains 122,930,327 (97.8%) buildings which resulted in a successful simulation. Future, annual updates have been proposed that may include additional buildings, data improvements, or other algorithmic enhancements. This dataset of 122.9 million buildings includes: Models (state_county.zip) - OpenStudio (v3.1.0) and EnergyPlus (v9.4) building energy models. Please note that the download requires the free Globus Connect Personal (https://www.globus.org/globus-connect-personal); Each model has approximately 3,000 building input descriptors that can be extracted. Please see the EnergyPlus(v9.4) 2,784-page Input/Output Reference Guide (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.4.0/InputOutputReference.pdf) for everything that can be retrieved or simulated from these models. These models were derived from the following metadata, which is not included in this dataset: 1. ID - unique building ID 2. County - county name 3. State - state name 4. CZ - ASHRAE Climate Zone designation 5. Clim_Zone - text label of climate zone 6. est_year - estimated year of construction 7. est_commercial - estimated building type (0=residential, 1=commercial) 8. Centroid - building center location in latitude/longitude (from Footprint2D) 9. Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) 10. Height - building height (meters) 11. Area2D - footprint area (ft2) 12. BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards 13. WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) 14. NumFloors - number of floors (above-grade) 15. Area - estimate of total conditioned floor area (ft2) 16. Standard - building vintage. These models are made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD), U.S. Dept. of Energy's (DOE) Building Technologies Office (BTO), Office of Electricity (OE), Biological and Environmental Research (BER), and National Nuclear Security Administration (NNSA). This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. Please cite as: New, Joshua R., Adams, Mark, Bass, Brett, Berres, Anne, and Clinton, Nicholas (2021). 'Model America - data and models of every U.S. building. [Data set].' Constellation, doi.ccs.ornl.gov/ui/doi/339, April 14, 2021

24 POWER TRANSMISSION AND DISTRIBUTION↗