Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow induced vibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Vibration exciting mechanisms induced by flow in turbomachine stages

The quasisteady computer analysis of the perturbated centrifugal impeller passage flow was reviewed. A total of 115 stage calculations were used to define the fluid damping coefficient, delta sub fluid. Results indicate that the average total damping coefficient per stage needed for stability is delta sub total 1.85.

Thompson, W. E.↗

On the Computation of Structural Vibrations Induced by a Low-speed Turbulent Flow

A method for numerical evaluation of the vibrations of a cylindrical shell structure induced by a low speed external turbulent flow is discussed. The direction of flow is along the axis of revolution of the shell, and the source of excitation is the pressure fluctuations in the turbulent boundary layer. For the investigation of vibration and noise problems it is usually more desirable to utilize the modal expansion approach. The axisymmetric shell structure can be modeled by the assemblage of conical-shell finite-elements. This modeling allows the eigenfunction psi sub mn (x,theta) to be represented in a rectangular product of a longitudinal modal function f sub mn (x) and a circular harmonic function cos m theta (or sin m theta).

Hwang, Y. F.↗

Role of Vibration-Induced Streaming in Float-Zone Crystal Growth

This presentation will examine in detail the role of vibration-induced streaming flow in the context of float-zone crystal growth. It is very well known that during float-zone materials processing, the naturally occurring temperature gradients along the zone surface impose a thermocapillary flow in the zone. Under certain processing conditions, the thermocapillary flow can also become nonsteady (oscillatory). The presence of thermocapillary flow is detrimental to crystal quality, for it can promote non-uniform dopant distribution and crystal striations. To null this effect we have imposed a counter streaming flow in the zone, via end-wall vibration. This technique has been adapted to float-zone processing of Sodium Nitrate-Barium Nitrate eutectic alloys, under both steady and nonsteady thermocapillary flow conditions. The beneficial effects of counter streaming flow have been clearly brought out through the before and after comparisons of the crystal microstructure. In addition, we are also examining the theoretical underpinnings of the balancing of thermocapillary flows with vibration-driven counter flows in float-zones.

Anilkumar, A. V.↗

Role of Vibration-Induced Streaming in Float-Zone Crystal Growth

This presentation will examine in detail the role of vibration-induced streaming flow in the context of float-zone crystal growth. It is very well known that during float-zone materials processing, the naturally occurring temperature gradients along the zone surface impose a thermocapillary flow in the zone. Under certain processing conditions, the thermocapillary flow can also become nonsteady (oscillatory). The presence of thermocapillary flow is detrimental to crystal quality, for it can promote non-uniform dopant distribution and crystal striations. To null this effect we have imposed a counter streaming flow in the zone, via end-wall vibration. This technique has been adapted to float-zone processing of Sodium Nitrate-Barium Nitrate eutectic alloys, under both steady and nonsteady thermocapillary flow conditions. The beneficial effects of counter streaming flow have been clearly brought out through the before and after comparisons of the crystal microstructure. In addition, we are also examining the theoretical underpinnings of the balancing of thermocapillary flows with vibration-driven counter flows in float-zones.

Anikumar, A. V.↗

Evaluation of RANS vs. LES simulation of fluid flow through 3 × 3 rod bundle with a simple spacer grid as a precursor to coupled fluid–structure interaction simulations

The research literature on Computational Fluid Dynamics (CFD) of coolant flow through rod bundles with spacer-grids and mixing vanes is replete, ranging from high fidelity Large Eddy Simulation (LES)/Direct Numerical Simulation (DNS) simulations to Reynolds-Averaged Navier–Stokes (RANS) modeled studies. The mixing of flow between subchannels and the pressure drop through the bundle are fundamental quantities useful for comparing and evaluating CFD methods. Less commonly observed and compared are the forces exerted onto the structure by the fluid. The present study seeks to evaluate the use of RANS simulations for predicting the structural response to fluid flow. Wall resolved RANS simulations are benchmarked against LES simulations of fluid flow at a Reynolds number of 15,000 through a 3 × 3 fuel rod bundle with a simple spacer grid. Velocity line-plots are compared showing good agreement between RANS and LES results, ascertaining that the former is capable of capturing the essential time-averaged velocity profile. Additionally, the distribution of forces on the spacer grid and fuel rods are collected as a function of time and space. The RANS methods are evaluated using the frequency and magnitude of the fluctuating forces on various portions of the structure as compared to LES. In conclusion, the power spectral density evaluation of the models reveal underprediction of force amplitude on the rod walls by RANS and also discrepancy in the prediction of high frequency spectra, especially in the immediate vicinity of spacer-grid structure, which may be attributed to the lack of random turbulence fluctuation or insufficient modeling of small-scale eddies in RANS simulation.

FIV↗

Wind-tunnel study of an observatory dome with a circular aperture

Results are presented from wind tunnel tests of the novel, 'fixed shutter' observatory dome concept, which is intended to minimize wind shake effects. In order to enclose larger telescopic apertures, this design allows an upper spherical segment to rotate under a shell of slightly larger diameter which is fixed to a lower rotatable segment. A side-by-side wind tunnel test comparison of this and a conventional dome shows that the mean and fluctuating velocity through the aperture and in the center of the new dome are lower than those of conventional domes, thereby lowering the likelihood of flow-induced telescope vibration.

Zilliac, Gregory G.↗

Effects of G-Jitter on Interfacial Dynamics of Two Miscible Liquids: Application of MIM

We designed an experiment to examine the effects of g-jitter on mixing of two miscible liquids using the Microgravity Vibration Isolation Mount (MIM). The global bifurcation of the interface was observed with the MIM operating alternatively to either transmit the g-jitter, isolate from the g-jitter or to provide controlled vibration levels with well defined amplitude and frequency content. With the MIM in isolation mode, the interface remains stationary indicating buoyancy induced convection is negligibly small such that mixing occurs via intrinsic mass diffusion without the masking effect of vibration driven convection. Analytical and computational results are in agreement with the experimental findings. Operation of the MIM in forced mode with conditions typical of g-jitter shows that vibration induced convective flows can excite instability mechanisms such as Kelvin-Helmholtz to generate large amplitude quasi-stationary waves oriented vertically for various cases with Stokes-Reynolds number in the range of 0.003 to 0.5. The two and four mode quasi-stationary waves are also predicted with a mathematical model. Though unplanned, the effect of a primary thruster filing was captured and shown to cause a catastrophic bifurcation, enhancing local mass transport. In light of the findings, experiments planned for the International Space Station should consider the potential effects of g-jitter.

Duval, Walter M. B.↗

The acoustic characteristics of turbomachinery cavities

Internal fluid flows are subject not only to self-sustained oscillations of the purely hydrodynamic type but also to the coupling of the instability with the acoustic mode of the surrounding cavity. This situation is common to turbomachinery, since flow instabilities are confined within a flow path where the acoustic wavelength is typically smaller than the dimensions of the cavity and flow speeds are low enough to allow resonances. When acoustic coupling occurs, the fluctuations can become so severe in amplitude that it may induce structural failure of engine components. The potential for catastrophic failure makes identifying flow-induced noise and vibration sources a priority. In view of the complexity of these types of flows, this report was written with the purpose of presenting many of the methods used to compute frequencies for self-sustained oscillations. The report also presents the engineering formulae needed to calculate the acoustic resonant modes for ducts and cavities. Although the report is not a replacement for more complex numerical or experimental modeling techniques, it is intended to be used on general types of flow configurations that are known to produce self-sustained oscillations. This report provides a complete collection of these models under one cover.

Lucas, M. J.↗

Low frequency vibrational stirring - A new method for rapidly mixing solutions and melts during growth

A new method for rapidly stirring liquids has been developed which may be useful in crystal growth applications. The method involves the introduction of orthogonally coupled low frequency vibrations to fluids contained in cylindrical crucibles. A mathematical model has been developed to describe the influence of this vibrational stirring method on fluid flow. The optimum sloshing frequencies calculated for a specific system geometry were very close to those observed experimentally. A systematic study of the fluid flow induced by the vibrational motion was carried out at room temperature using aqueous solutions containing glycerine. Preliminary experiments were carried out to study the effect of vibrational stirring on interface shape and position during the Bridgman growth of CsCdCl3, a model system.

Liu, W.-S.↗

The application of laser induced predissociation fluorescence to the measurement of vibrational temperatures in a shock layer flow

Single shot spatially and spectrally resolved laser induced predissociation fluorescence measurements in a shock layer around a cylinder in a pulsed supersonic free stream are presented. Fluorescence signals were produced using the tuned output of an argon fluoride excimer laser to excite a mixture of rovibrational transitions in molecular oxygen. The signals produced along a line inside the shock layer were focussed onto a two dimensional detector coupled to a spectrometer, thus allowing spectral and spatial resolution of the fluorescence. In this way, it was possible to detect two fluorescence signals from two different transitions simultaneously, allowing the determination of vibrational temperatures without the need for calibration. However, to minimize problems associated with low signal to noise ratios, background subtraction and spatial averaging was required. The experimental measurements are compared with theoretical inviscid shock layer calculations for nonequilibrium air. A description of the strategies employed in these calculations is also provided.

Sutton, D. J.↗

Effects of End-Wall Vibration on Oscillatory Thermocapillary Flow

Our previous float zone experiments 1,2 with NaNO3 revealed that steady thermocapillary flow (TC flow) can be balanced/offset by the controlled surface streaming flow (CSS flow), induced by end-wall vibration. In the current experiments, we are examining the effects of surface streaming flow on steadying/stabilizing oscillatory thermocapillary flow. To this effect, we have set up a controlled NaNO3 half-zone experiment, where the processing parameters like zone dimensions and temperature gradients scan be easily varied to achieve oscillatory TC flow. In the present paper, we discuss the thermal signature of the TC flow, and how it is affected by imposition of CSS flow. The results will also include a comparison of the microstructure of a NaNO3- BaNO3 eutectic, processed under oscillatory TC conditions, with and without imposed CSS flow.

Bhowmick, J.↗

Hydrokinetic energy harvesting from slow currents using flow-induced oscillations

To harness marine hydrokinetic energy from slow flows, which constitute the majority of currents, tides, and rivers, new Passive Turbulence Control (PTC), consisting of large turbulence stimulators, is tested experimentally on circular cylinders on springs. Here, this study experimentally investigates the effect of PTC on the onset of Flow-Induced Oscillations (FIO) and particularly the relative onset of Vortex-Induced Vibrations (VIV) and galloping. Experiments are conducted in the Low Turbulence Free Surface Water Channel, University of Michigan. Fixed are: mass ratio m* = 1.48, aspect ratio l/D = 10.29, and total damping ratio ζ = 0.04. Parameters are: cylinder diameter D, spring stiffness K, PTC location and height, and flow speed U$\in$[0.36 m/s-1.45 m/s]. Placing the leading edge of PTC at 40–60° induces high amplitude FIO while placement at 10–20° suppresses FIO. As PTC height increases, VIV and galloping initiate earlier and exhibit higher amplitude with a steeper slope. Lower spring stiffness initiates VIV earlier by reducing the oscillator natural frequency in water. Even though large PTC maintained its effectiveness in initiating galloping early, it has no effect on the earlier initiation of VIV, which starts at a nearly fixed reduced velocity. Lower spring stiffness and large PTC enable power generation at low current speed (0.2 m/s).

16 TIDAL AND WAVE POWER↗

Utilizing Controlled Vibrations in a Microgravity Environment to Understand and Promote Microstructural Homogeneity During Float-Zone Crystal Growth

Our previous experiments with NaNO3 float-zones revealed that steady thermocapillary flow can be balanced/offset by the controlled surface streaming flow induced by end-wall vibration. In the current experiments we are examining the effects of streaming flow on steadying/stabilizing nonsteady thermocapillary flow in such zones. To this effect we have set up a controlled NaNO3 half-zone experiment, where the processing parameters, like zone dimensions and temperature gradients, can be easily varied to generate nonsteady thermocapillary flows. In the present paper we present preliminary results of our investigations into stabilizing such flows by employing end-wall vibration.

Anilkumar, A. V.↗

Utilizing Controlled Vibrations in a Microgravity Environment to Understand and Promote Microstructural Homogeneity During Floating-Zone Crystal Growth

Our previous experiments with NaNO3 float-zones revealed that steady thermocapillary flow can be balanced/offset by the controlled surface streaming flow induced by end-wall vibration. In the current experiments we are examining the effects of streaming flow on steadying/stabilizing nonsteady thermocapillary flow in such zones. To this effect we have set up a controlled NaNO3 half-zone experiment, where the processing parameters, like zone dimensions and temperature gradients, can be easily varied to generate nonsteady thermocapillary flows. In the present paper we present preliminary results of our investigations into stabilizing such flows by employing endwall vibration.

Anilkumar, A. V.↗

Hydrokinetic Energy Conversion by Flow-Induced Oscillation of Two Tandem Cylinders of Different Stiffness

Abstract The vortex-induced vibration for aquatic clean energy (VIVACE) converter harnesses hydrokinetic energy by enhancing flow-induced oscillations (FIOs) of elastically supported rigid cylinders in a river, tide, or ocean current. The harnessing power depends on the intensity of the oscillation, which is a consequence of the flow–structure interaction. The inflow condition for the downstream (second) cylinder is slowed down and perturbed by the upstream (first) cylinder, due to the shielding effect. Therefore, the optimal structural parameters, i.e., stiffness and damping ratio, for the second cylinder may be different from the first cylinder, in terms of energy harnessing. To improve the performance of the VIVACE converter, a series of experiments are conducted in a recirculating water channel, with various stiffness combinations of two cylinders in tandem. Results show that the stiffness of the second cylinder, K2, does not affect the energy harnessing power in vortex-induced vibration (VIV) occurring at low speeds, because the oscillation of the downstream cylinder in this velocity range is completely dominated by the wake of the upstream cylinder. K2 has a great influence on the harnessing power at higher velocities in the transition region from VIV to galloping and in galloping. Changing K2 onsets and enhances galloping at lower flow velocity and harnesses up to 110% more energy than the case of K1 = K2.

Engineering↗

A fast multi-fidelity method with uncertainty quantification for complex data correlations: Application to vortex-induced vibrations of marine risers

Here we develop a fast multi-fidelity modeling method for very complex correlations between high- and low-fidelity data by working in modal space to extract the proper correlation function. We apply this method to infer the amplitude of motion of a flexible marine riser in cross-flow, subject to vortex-induced vibrations (VIV). VIV are driven by an absolute instability in the flow, which imposes a frequency (Strouhal) law that requires a matching with the impedance of the structure; this matching is easily achieved because of the rapid parametric variation of the added mass force. As a result, the wavenumber of the riser spatial response is within narrow bands of uncertainty. Hence, an error in wavenumber prediction can cause significant phase-related errors in the shape of the amplitude of response along the riser, rendering correlation between low- and high-fidelity data very complex. Working in modal space as outlined herein, dense data from low-fidelity data, provided by the semi-empirical computer code VIVA, can correlate in modal space with few high-fidelity data, obtained from experiments or fully-resolved CFD simulations, to correct both phase and amplitude and provide predictions that agree very well overall with the correct shape of the amplitude response. We also quantify the uncertainty in the prediction using Bayesian modeling and exploit this uncertainty to formulate an active learning strategy for the best possible location of the sensors providing the high fidelity measurements.

42 ENGINEERING↗

Centrifugal Size-Separation Sieve for Granular Materials

A centrifugal sieve and method utilizes centrifugal force in rapidly-rotated cylindrical or conical screens as the primary body force contributing to size segregation. Within the centrifugal acceleration field, vibration and/or shearing flows are induced to facilitate size segregation and eventual separation of the fines from the coarse material. Inside a rotating cylindrical or conical screen, a separately-rotated screw auger blade can be used to transport material along the rotating cylinder or conical wall and to induce shearing in the material.

Walton, Otis↗