Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a forced advection sampling technique (FAST) for quantification of methane emissions from orphaned wells

Abstract. Orphaned wells, meaning unplugged and non-producing wells lacking responsible owners, pose a significant and undersampled environmental challenge due to their vast number and unknown associated emissions. We propose, develop and test an alternative method for estimating emissions from orphaned wells using a forced advection sampling technique (FAST) that can overcome many of the limitations in current methods (cost, accuracy, safety). In contrast to existing ambient Gaussian plume methods, our approach uses a fan-generated flow to force advection between the emission source and a point methane (CH4) sensor. The fan flow field is characterized using a colocated sonic anemometer to measure the 3D wind profile generated by the fan. Using time-series measurements of CH4 concentration and wind, a simple estimate of the CH4 emission rate of the source can be inferred. The method was calibrated using outdoor controlled-release experiments and then tested on four orphaned wells in Lufkin, TX, and Osage County, OK. Our results suggest that the FAST method can provide a low-cost, portable, fast and safe alternative to existing methods with reasonable estimates of orphaned well emissions over a range of leak rates below 40 g h−1 and within certain geometric and atmospheric constraints.

Dubey, Mohit L↗

Particulate matter sensor

Microfabricated PM sensors measure concentrations of particulate matter (PM) in air. Some sensors improve the accuracy of measurements by accounting for the effect of ambient conditions (e.g., temperature or humidity) on mass-sensitive elements employed to determine a mass of the PM in a stream of air. Some sensors improve the accuracy of measurements by controlling humidity in the stream of air measured by mass-sensitive elements. Some sensors employ a plurality of mass-sensitive elements to extend the useful life of the PM sensor. Some sensors employ one or more mass-sensitive elements and heating elements to cause deposition and allow measurement of different sizes of PM. Some sensors can measure mass concentration of coarse PM in addition to fine PM in a stream of air. Some sensors control the flow rate of a stream of air measured by mass-sensitive elements. Some sensors include features to mitigate electromagnetic interference or electromagnetic signal loss.

Paprotny, Igor↗

Impact of Flow Configurations on Response Time and Data Quality in Real-Time, In-Line Fourier Transform Infrared (FTIR) Monitoring of Viscous Flows

The real-time, in-line monitoring of continuous flow concentrations is widely conducted via infrared (IR) spectrometry by using a flow cell connected to a reactive flow stream. For protective purposes, the IR sensor tip is typically offset from the flow. This offset can cause the formation of a stagnant boundary layer above the sensor, especially when dealing with high-viscosity fluids. As a result, the IR signal response time is often controlled by the slow diffusional exchange of fluid in the boundary layer, as confirmed via 2D computational fluid dynamics (CFD) simulations. We evaluated several flow configuration modifications in a typical IR flow cell in order to identify the changes to the flow dynamics that enable improved response times with minimal changes to the cell configuration: the use of (i) vertical flow, where the standard horizontal flow over the sensor is redirected to contact vertically with the sensor, (ii) a static mixer to create radial flow momentum above the IR sensor, and (iii) horizontal or vertical nozzles to direct the flow toward the IR sensor. The vertical flow configuration did not show any significant improvement over the standard horizontal flow configuration. However, the static mixer, horizontal nozzle, and vertical nozzle configurations all resulted in markedly improved response times and signal quality, albeit at the expense of a higher pressure drop across the flow cell. These results point toward straightforward, user-accessible modifications of in-line IR flow cells that result in significant improvements in signal stability and acquisition times.

42 ENGINEERING↗

Scalable graphene sensor array for real-time toxins monitoring in flowing water

Abstract Risk management for drinking water often requires continuous monitoring of various toxins in flowing water. While they can be readily integrated with existing water infrastructure, two-dimensional (2D) electronic sensors often suffer from device-to-device variations due to the lack of an effective strategy for identifying faulty devices from preselected uniform devices based on electronic properties alone, resulting in sensor inaccuracy and thus slowing down their real-world applications. Here, we report the combination of wet transfer, impedance and noise measurements, and machine learning to facilitate the scalable nanofabrication of graphene-based field-effect transistor (GFET) sensor arrays and the efficient identification of faulty devices. Our sensors were able to perform real-time detection of heavy-metal ions (lead and mercury) and E. coli bacteria simultaneously in flowing tap water. This study offers a reliable quality control protocol to increase the potential of electronic sensors for monitoring pollutants in flowing water.

47 OTHER INSTRUMENTATION↗

Development of a Test-Bed for Testing and Refining EarthEn’s Supercritical CO 2 Based Energy Storage System

EarthEn’s energy storage concept leverages supercritical carbon dioxide (sCO 2 ) as a working fluid and relies on compact, high-performance components operating at elevated pressures and temperatures. To accelerate component development and reduce technical risk prior to larger-scale demonstrations, Oak Ridge National Laboratory (ORNL) developed a 100 kW-scale sCO 2 test-bed under a Cooperative Research and Development Agreement with EarthEn (CRADA NO. NFE-24-10050). The objective of the work was to design and construct a flexible experimental facility capable of reproducing key thermodynamic state points and heat-transfer conditions relevant to EarthEn’s thermal energy storage (TES) cycle, with particular emphasis on enabling development and evaluation of next-generation heat exchangers and TES concepts. The test-bed consists of a closed-loop sCO 2 circulation system housed within an open-topped enclosure. In its as-installed configuration, dense-phase sCO 2 is recirculated through a printed circuit recuperator, an electrically heated section, a throttling device used to simulate turbine expansion, and a water-cooled printed circuit heat exchanger that rejects heat to the building chilled-water system before returning to the pump. The pump is driven by a variable frequency drive, enabling controlled adjustment of flow and operating point. A comprehensive instrumentation suite was integrated to support both safe operation and high-quality data collection. Installed sensors include Coriolis flow meters for sCO 2 flow rate and density, resistance temperature detectors and thermocouples distributed throughout the loop (including the heated section and key heat exchanger ports), and pressure transducers for absolute and differential pressure measurements. The facility was designed to support high-pressure (19 MPa nominal) and high-temperature (575°C nominal) operation with credited overpressure protection provided by a rupture disk. Nominal operating conditions were selected to support 100 kW-class testing while maintaining flexibility for non-heated and heated shakedown, control development, and future integration of advanced TES test sections. In parallel with facility development, a system-level thermal-hydraulic model was created using Modelica-based tools to support component sizing, anticipate performance over targeted test conditions, and establish a framework for future model calibration against experimental data. At the conclusion of the project performance period, the facility was in final assembly, and the pressure boundary was nearly completed. However, several practical challenges associated with high-pressure/high-temperature systems and specialized component procurement impacted schedule and prevented initial pump-driven operation and full commissioning within the available resources. This report documents the as-built design, operating capabilities, and instrumentation, and it summarizes key lessons learned related to heater fabrication and testing, first-of-a-kind assembly factors, specialty flange supply constraints, and fill pump corrective actions. Finally, it outlines a phased plan for future commissioning and experimental campaigns, including control and instrumentation shakedown, heater characterization, model calibration, and testing at state points representative of EarthEn’s TES cycle.

25 ENERGY STORAGE↗

Optimal sensor network design for multi-scale, time-varying differential algebraic equation systems: Application to an entrained-flow gasifier refractory brick

An algorithm for optimal sensor network design for multi-scale, time-varying differential algebraic equation systems with non-separable dynamics is presented. As the process is time-varying, an integral normalized posterior error covariance of a multi-scale filter is minimized to obtain the optimal sensor locations. For reducing the computational cost, an adaptive sampling rate approach is considered for the slowly-varying variables. The algorithm is applied to a smart refractory brick with embedded sensors as part of an entrained-flow gasifier. Thermistors and interdigital capacitors are considered as candidate measurement technologies for estimating temperature and slag penetration profile along the gasifier wall. Finally, when the optimal set of sensors obtained from the algorithm is used for estimating temperature and slag penetration profiles in a multi-scale Kalman filter framework, satisfactory estimates are obtained despite high measurement noise and model mismatch.

42 ENGINEERING↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wellbore Fracture Imaging Using Inflow Detection Measurements

One of the most striking measurements taken during DOE’s EGS Collab project at the 4850-foot depth location was the so-called ‘sewer cam’, which enabled direct visualization of the flow of water into the production well through fractures during the stimulation. The ability to see directly which fractures were flowing and (roughly) how much was a breakthrough in understanding the topology of the created fracture network. Achieving this kind of fracture flow imaging at FORGE would be more challenging because of the 225°C temperature, but equally or even more valuable if it could be achieved. In 2017, a joint project between Sandia and Stanford developed a downhole tool concept to measure the enthalpy of multiphase fluid entering a geothermal well from individual fractures (Gao et al., 2017). For the FORGE project, measuring enthalpy is of less interest because the fluid is expected to be single-phase liquid water. However, the foundation of the device was the measurement of chloride ion concentration, which could form the basis for a direct measurement of inflow from fractures. During the 2017 project, this novel chloride sensing system was implemented into a laboratory test instrument, and we confirmed the capability of the system to measure the ion concentration of fluid entering a model wellbore through a small entry port. The wellbore was a 6-inch diameter model well, and the port was approximately 0.08 inch (2mm) in diameter. The device could measure the chloride concentration accurately even when the well was flowing in a bubbly flow. Given its accuracy, the tool should be able to identify locations of water entering the wellbore even if the ion concentration differs only slightly from that of the water in the well. It is likely that different fractures may flow slightly different chloride concentrations, which would make it feasible to detect individual fractures as well as to estimate the volume of their flow. Ultimately, we could also recognize different fractures flowing back significantly different ion concentrations after fracturing in the FORGE wells. This could be realized by adding different ions in the fracturing fluids in different fractures created at different stages of stimulation (and modifying the tool to include different ion specificity). Sandia’s tool was shown during the study to have the capability to withstand the 225°C temperature, and the electrochemical sensing elements were tested in the laboratory to 225°C at 1500 psia for 24 hours. An early implementation of the fully integrated downhole electrochemical tool, including high-temperature electronics, robust housing, and wireline truck interface, had previously been constructed and tested successfully at Sandia; thus, hardware development tasks focused on advancing the technology readiness level (TRL) of this promising technology for FORGE deployment, rather than on developing a new scientific basis for its operation. The data collection electronics in this tool allowed for several other sensors (pressure, temperature, flow spinner) to be implemented in parallel as well. The research was a new collaboration between Stanford and Sandia to modify and refine the tool for FORGE deployment, to make the downhole measurements, and to characterize the evolving fractures.

15 GEOTHERMAL ENERGY↗

Multivariate environmental and trait-based controls of transpiration in the Central Amazon Rainforest

Tropical forest tree mortality is increasing due to more severe droughts, yet our understanding of how tree traits and life strategies are linked to drought stress has been limited by measurement scarcity. The BIONTE (BIOmass and NuTrient Experiment) near Manaus, Brazil hosts one of the world’s largest sap flow installations, with sensors in 90 canopy trees across a wood density gradient monitored since June 2022. The 2023 El Niño drought provided a unique opportunity to evaluate how water availability impacts tree transpiration. An interpretable machine learning framework was used to study the complex interactions between transpiration and multiple environmental variables such as soil water availability and vapor pressure deficit (VPD), and how these interactions vary with wood density and individual trees. We found varying responses of transpiration from different trees during the El Niño drought. Transpiration generally increased with temperature, with stronger effects in wetter areas and in trees with low to medium wood density. However, this response was modulated by stomatal sensitivity to VPD, which constrained transpiration under high atmospheric demand, particularly in intermediate-moisture area. The inflection in transpiration rate at high temperatures (>32°C) underscores the role of stomatal and hydraulic regulation in limiting water loss and protecting trees from excessive evaporative demand. Analysis of soil water contribution to transpiration revealed unimodal patterns in wetter area, with peak contributions near 0.45 cm 3 cm -3 of surface soil water and declining or flat responses beyond that threshold, suggesting a shift from water- to energy-limited transpiration. In contrast, drier areas exhibited limited transpiration sensitivity to soil water conditions and minimal trait-based variation in VPD responses, indicating supply-limited conditions. Despite higher wood density trees being generally more resilient, this study shows diverse tree drought resilience, prompting further investigation into the specific traits and dynamics between environmental variables in regulating transpiration and other physiological processes in trees.

Drought↗

Efficient and Flexible Sensitivity Matrix Computation for Adaptive Electrical Capacitance Volume Tomography

Electrical capacitance tomography is a widely used sensor modality for flow imaging in many industrial settings. Adaptive Electrical Capacitance Volume Tomography (AECVT) extends the capabilities of traditional ECT by enabling direct volumetric imaging and an improved resolution. Construction of the sensitivity matrix is a necessary step to obtain flow images. This step requires computation of the electric field inside the sensing domain, which is done via a typical field solver such as the finite element method. In this work, we present an efficient and flexible method to construct the sensitivity matrix for Adaptive Electrical Capacitance Volume Tomography (AECVT) based on individual electrode segment excitations and their judicious combination to form desired matrix elements. We illustrate how the proposed method yields the same sensitivity matrix as the traditional method but at a much lower computational cost. Once all segment contributions are obtained, we also indicate how the proposed method, unlike the traditional approach, can generate the sensitivity matrix on demand for an arbitrary combination of synthetic electrodes and obviating the need for any additional field computations. Finally, we present image reconstruction results for two different experimental scenarios where the mutual capacitance data and the corresponding sensitivity vectors are obtained through the proposed measurement combination scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the Electromechanical Sensitivity of Carbon-Nanotube-Coated Microfibers

The piezoresistance of carbon nanotube (CNT)-coated microfibers is examined using diametric compression. Diverse CNT forest morphologies were studied by changing the CNT length, diameter, and areal density via synthesis time and fiber surface treatment prior to CNT synthesis. Large-diameter (30–60 nm) and relatively low-density CNTs were synthesized on as-received glass fibers. Small-diameter (5–30 nm) and-high density CNTs were synthesized on glass fibers coated with 10 nm of alumina. The CNT length was controlled by adjusting synthesis time. Electromechanical compression was performed by measuring the electrical resistance in the axial direction during diametric compression. Gauge factors exceeding three were measured for small-diameter (<25 μm) coated fibers, corresponding to as much as 35% resistance change per micrometer of compression. The gauge factor for high-density, small-diameter CNT forests was generally greater than those for low-density, large-diameter forests. A finite element simulation shows that the piezoresistive response originates from both the contact resistance and intrinsic resistance of the forest itself. The change in contact and intrinsic resistance are balanced for relatively short CNT forests, while the response is dominated by CNT electrode contact resistance for taller CNT forests. These results are expected to guide the design of piezoresistive flow and tactile sensors.

36 MATERIALS SCIENCE↗

Incineration system and process

An incineration system includes an inlet channel supplying an inlet stream comprising a waste gas containing at least one volatile organic compound, a waste gas sensor measuring at least one property of the waste gas, an oxidizing gas supply controllably providing oxidizing gas to the inlet channel, an incinerator receiving the inlet stream from the inlet channel, an ignitor initiating combustion of the inlet stream in the reaction zone of the incinerator, and a controller receiving data from the waste gas sensor and controlling flow of oxidizing gas from the oxidizing gas supply into the inlet channel. The spiral heat exchanger defines a reaction zone, an incoming path from the inlet channels to the reaction zone, and an outgoing path from the reaction zone to an exhaust channel. The incoming path and the outgoing path extend in alternating concentric spirals with the incoming path being countercurrent to the outgoing path.

42 ENGINEERING↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

High spatial resolution temperature profile measurements of solid-oxide fuel cells

Temperature gradients resulting from local electrochemical reactions, current distribution and geometry of gas flow channels in solid oxide fuel cells (SOFCs) create thermal stresses, localized thermophysical property gradients and uneven property evolution, contributing to SOFC degradation. This paper presents a new method to perform temperature measurements (up to 800°C) at high spatial resolutions to monitor the operation of SOFCs. Using femtosecond laser irradiation, distributed fiber sensors were hardened for high temperature environment applications. Distributed fiber sensors were embedded in interconnected plates using an additive manufacturing method to perform temperature measurements with 4-mm spatial resolution during the operation of a planar fuel cell. The measurement revealed the impact of various H 2 fuel concentrations and current loads have on temperature profiles of the SOFC tested. Temperature variation on the anode side was found to be less than 5°C, and 3°C on the cathode side. The measurements were compared to results from a multiphysics fuel cell performance model simulating similar conditions. These simulations predicted similar temperature gradients, indicating the experimental data obtained is reasonable. The model also predicts that the effect of the embedded sensor has on the local temperature will be minimal and that the gradient of temperature in the gas channels will be captured despite the separation between the sensor and the gas flow. Finally, the high spatial resolution data harnessed by these distributed fiber sensors provides experimental support for model-based design and optimization to improve the operational efficiency and longevity of solid oxide fuel cells and fuel cell assemblies.

25 ENERGY STORAGE↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Savannah River Site H-Canyon Advancing Technologies for Remote Inspections - 20345

In 2017, the DOE Environmental Management Office of Technology Development (DOE-EM TD) sponsored the H-Canyon Advanced Technology Demonstration (ATD) to demonstrate to DOE facilities the value of using new commercial-off-the-shelf (COTS) and near-ready technologies to solve difficult problems and enhance worker safety. The DOE Savannah River Site (SRS) H-Canyon Air Exhaust Tunnel (HCAEX) inspection task was identified as representative of the hazardous, human denied environments which could benefit from advanced technologies. The HCAEX underground concrete tunnel is visually inspected biannually using a camera mounted on a remotely operated vehicle (ROV) designed and built by SRNL. While tunnel images have provided valuable visual information, it is desirable to have a higher order of understanding of the environment to support a more thorough structural integrity (SI) analysis and for long term planning purposes. As part of the ATD, the Concrete Integrated Product Team (CIPT) was formed to identify and evaluate available sensors and methods mature enough to remotely obtain tunnel concrete characterization data of high value and with a high probability of success. The team included SMEs and H-Canyon stakeholders in the field of concrete, nondestructive examination (NDE), structural integrity, sensors and remote systems from SRNL, SRNS, LANL, DOE-SR and the Army Corps of Engineering. The CIPT completed an in-depth identification of customer concrete inspection needs and potential technology solutions. Sensors and methods were evaluated on performance, data usefulness, cost and the feasibility of a successful deployment given the unique tunnel access challenges and environment. Two technologies were identified as promising by the CIPT for near term demonstration and evaluation: Lidar (Light Detection and Ranging) 3-dimensional (3D) mapping and remote robotic deployment of NDE instrumentation. Laser spectroscopy to characterize tunnel surface chemical changes was also of interest, but presently cost prohibitive. This paper will include a discussion of the two efforts underway to evaluate and implement the CIPT recommendations. First, the status of the November 2019 deployment of Lidar at a single location into the tunnel is presented. This initial deployment provided the team a learning curve and lessons learned on the challenges of tunnel deployment to include remote operation and data collection, stabilization of the sensor in high air flow (∼30 mph), ability to achieve a tolerance accuracy of 0.25-inches, and the probability to identify change in tunnel dimensions over time. Secondly, a discussion on the development of the Robotic Arm Concrete Inspection Test Bed capable of deploying NDE instruments to examine custom concrete forms will be presented. Concrete forms simulating the rough concrete surfaces, strength, composition and potential structural defects that can be found at our DOE EM facilities have been designed and built for the test bed. Two state-of-the art concrete NDE instruments have been identified as having potential to work on rough concrete walls, they are being tested and characterized as to their ability to provide desired structural integrity data to include wall thickness and defect identification on the developed test beams. Lastly, lessons learned, and the path forward will be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗