Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluctuation diagnostic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison of Doppler back-scattering and charge exchange measurements of E × B plasma rotation in the DIII-D tokamak under varying torque conditions

Measurements of the E × B toroidal angular velocity, $\omega_{E \times B}\,=\,E_\mathrm{r}/RB_\theta$ ($E_\mathrm{r}$ is the radial electric field, B θ is the poloidal magnetic field), are made using the Doppler back-scattering (DBS) and charge-exchange recombination (CER) spectroscopy diagnostics. DBS uses the Doppler shift of wavenumber-resolved density fluctuations while CER uses the Doppler shift of impurity emission lines to independently measure plasma parameters for calculating the local radial electric field. DBS and CER profiles of $\omega_{E \times B}$ as a function of normalized toroidal flux (ρ) are compared at various levels of neutral beam applied torque on the plasma. Under standard neoclassical theory $\omega_{E\times B}$ is a flux surface quantity, making it appropriate to compare across diagnostics. DBS and CER generally show good agreement when comparing $\omega_{E \times B}$ profiles at different levels of neutral beam injection-applied torque. Furthermore, the DBS values have close to the same precision as CER values when averaged over a similar time-scale and effects, such as prompt-torque are considered. DBS is able to observe the rapid ($\lt$10 ms) modification of the $E_\mathrm{r}$ profile by the diagnostic neutral beam 'blips'. This modification is most pronounced when the blip applies a large relative change in torque on the plasma. Overall, these results could have implications on transport analysis and suggests using DBS and CER in conjunction to constrain values of the E × B-shear (sometimes called $\gamma_{E \times B}$).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic profile prediction and validation of a negative triangularity plasma in ASDEX Upgrade

In this work, gyrokinetic simulations are performed with the CGYRO code (Candy et al 2016 J. Comput. Phys. 324 73–93) for a negative triangularity H-mode plasma in ASDEX Upgrade, and compared with experimental measurements. The PORTALS framework (Rodriguez-Fernandez et al 2024 Nucl. Fusion 64 076034) is used to accelerate the prediction of kinetic profiles for this plasma, using surrogate modeling and Bayesian optimization. Ion heat flux, electron heat flux, and electron particle flux are simultaneously matched across the simulated radial regime of the plasma (normalized radius $r/a = 0.35-0.90$), and the resulting ion temperature, electron temperature, and electron density profiles match well with the experimental profile data within this radial range. A synthetic Correlation Electron Cyclotron Emission diagnostic is applied to find well-matched electron temperature fluctuation properties between simulation and experiment. The flux-matched profiles provide a basis for investigation of the turbulence nature across the plasma radius, revealing the dominance of Trapped Electron Mode turbulence at $r/a = 0.35$, the dominance of Ion Temperature Gradient turbulence at $r/a = 0.55$, 0.75, and 0.83, and an instability boundary at $r/a = 0.90$.

gyrokinetic simulation↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Reconstruction of magnetic island electron temperature in mixed second and third harmonic electron cyclotron emission conditions

Here we develop a method to use the mixed third and second harmonic electron cyclotron emission (ECE) signal in the DIII-D tokamak to reconstruct the electron temperature profile of a rotating magnetic island. The third harmonic ECE is removed by extracting the rotating-island-associated fluctuations in the mixed signal, and the extracted fluctuation is combined with the equilibrium temperature obtained from other diagnostics after correcting for the third harmonic reabsorption. The accuracy of the reconstruction is studied by considering a DIII-D shot where an unmixed signal from an island is available on the low field side of the plasma and a mixed signal from the same island is available from the high field side. It is found that the reconstruction method successfully reproduces the island shape and temperature perturbation magnitude without the distortion caused by third harmonic ECE mixing. However, the radial location of the reconstructed island is somewhat displaced relative to the location of the q = 2 surface in the axisymmetric equilibrium reconstruction, resulting in a corresponding inaccuracy in the absolute temperature of the island. It is conjectured that this may arise from an inaccuracy of the reconstructed axisymmetric equilibrium in this region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of radial interferometer–polarimeter for internal magnetic and density fluctuation measurements at multiple space–time scales in the National Spherical Torus Experiment-Upgrade (NSTX-U)

A Faraday-effect radial interferometer–polarimeter is designed for the National Spherical Torus Experiment-Upgrade (NSTX-U) to measure multiscale magnetic and density fluctuations critical to understanding fusion plasma confinement and stability, including those originating from magnetohydrodynamic instabilities, energetic particle-driven modes, and turbulence. The diagnostic will utilize the three-wave technique with 5 MHz bandwidth to simultaneously measure line-integrated magnetic and density fluctuations up to the ion-cyclotron frequency. Probe beams will be launched radially from the low-field side at the NSTX-U midplane, where the measured Faraday fluctuations mainly correspond to radial magnetic fluctuations that directly link to magnetic transport. A correlation technique will be employed to reduce the measurement noise to below 0.01° enabling detection of small amplitude fluctuations. Two toroidally displaced chords with 7° separation will be installed to measure toroidal mode numbers up to n = 25 for mode identification. Finally, solid-state microwave sources operating at 321 μm (935 GHz) will be used to minimize the impact of the Cotton–Mouton effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Wendelstein 7-X phase contrast imaging diagnostic

We report a phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. The PCI diagnostic provides a line-integrated measurement of turbulent electron density fluctuations, which is essential for understanding high performance scenarios that can lead to improved confinement at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, which arise from Alfvén eigenmodes or other MHD activity. This paper provides an overview of the hardware and the optical system and presents an example PCI measurement from the W7-X OP1.2b experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full-wave model for the lower hybrid wave electric field vector with synthetic turbulence on Alcator C-Mod

The effects of synthetic turbulence on lower hybrid (LH) wave field magnitude and polarization are studied on Alcator C-Mod. Three synthetic turbulence models are evaluated to assess the impact of filaments, holes, and periodic fluctuations on the LH wave electric fields. For all three cases, the synthetic turbulence can greatly impact the LH wave magnitude and polarization. Back scattering, interference and edge/SOL absorption of the LH wave is observed. This impact is shown to depend on the wavelength and amplitude of the fluctuations. The strongest effect appears for fluctuations at high amplitudes and wavelengths comparable to the LH wavelength. This synthetic turbulence model can be used as inputs into a synthetic diagnostic to calculate the lower hybrid wave field magnitude and direction measured by dynamic Stark effect spectroscopy. It will be shown that fluctuations at these high amplitudes and wavelengths may explain the experimentally measured results. Here, the effect of fluctuations on modifying LH polarization are also shown to be anti-correlated with SOL power losses, similar to recently observed experimental trends on Alcator C-Mod. These SOL losses may have detrimental impact on LHCD efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applicability of alkali beam emission spectroscopy on NSTX-U

Understanding fast pedestal dynamics and turbulent transport in the edge and scrape-off layer (SOL) plasma of spherical tokamaks is crucial for the design and operation of future fusion reactors. The alkali beam emission spectroscopy diagnostic technique offers a means to measure the absolute electron density radial profile and fluctuation amplitude in these regions. Here, in this study, we demonstrate that injecting a sodium neutral beam radially into the plasma and analyzing the light emission from its 3p–3s atomic transition using near-orthogonal viewing angles allows for accurate measurement of the electron density profile and fluctuations in the National Spherical Torus Experiment (NSTX) Upgrade spherical tokamak. Our findings indicate a peak signal-to-noise ratio of 118 in the pedestal and 12 in the SOL under typical NSTX plasma conditions. The spatial resolution for the electron density profile is estimated to be between 2 and 8 mm, while for fluctuation measurements, it ranges from 12 to 15 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

Experimental study of high-k turbulence during an energy confinement degradation phase in EAST ohmic plasmas

In this paper, we present experimental studies of both high-k(r) ( cm(-1), and , respectively; ) and high- ( cm(-1), and , respectively; ) turbulence behavior during an ohmic energy confinement degradation phase in experimental advanced superconducting tokamak (EAST). High-k(r) turbulence from density fluctuation at and high- turbulence from density fluctuation at -0.97 were measured by tangential and poloidal CO2 laser collective scattering diagnostics, respectively. Note that k(r), , and are radial wavenumber, poloidal wavenumber, perpendicular wavenumber and ion gyroradius at electron temperature, respectively. Both high-k(r)/ turbulence power and energy confinement time are found to be temporally correlated to line-averaged electron density n(e) in the plasma current flat-top phase (I-p = 0.4 MA): when the n(e) shows continuous increase/decrease, the high-k(r)/ turbulence power increases/decreases correspondingly and the shows corresponding decrease/increase; the stable n(e) is related to stable both and high-k(r)/ turbulence power. Statistical results of high-k(r)/ turbulence power versus further imply that high-k(r)/ turbulence shows a strong correlation with plasma energy confinement degradation in high line-averaged n(e) condition, but high-k(r) and high- turbulence have relatively weak and no dependence on the transition between linear range in low-n(e) condition and energy confinement degradation in the high-n(e) condition, respectively. Moreover, profiles of electron temperature T-e and n(e) as well as their normalized gradients in a part of high- density fluctuation measurement region also have been given to qualitatively explain the enhancement of turbulence power with the increase of line-averaged n(e).

EAST tokamak↗

Simultaneous reproduction of experimental profiles, fluxes, transport coefficients, and turbulence characteristics via nonlinear gyrokinetic profile predictions in a DIII-D ITER similar shape plasma

Experimental conditions obtained on the DIII-D tokamak in the ITER Similar Shape (ISS) have been compared extensively with nonlinear gyrokinetic simulation using the CGYRO code [Candy et al., J. Comput. Phys. 324, 73–93 (2016)] with comparisons spanning ion and electron heat fluxes, electron and impurity particle transport, and turbulent fluctuation levels and characteristics. Bayesian optimization techniques [Rodriguez-Fernandez et al., Nucl. Fusion 62(7), 076036 (2022)], combined with nonlinear gyrokinetics, have been used to obtain simultaneously Qi, Qe, and Γe flux-matched profiles that are found to be in good agreement with experimental profile measurements. Synthetic diagnostics were used to compare measured beam emission spectroscopy and correlation electron cyclotron emission turbulent fluctuations with nonlinear simulation. Although some disagreements exist, nonlinear simulations are found to be in generally good agreement with measured fluctuation levels, spectral shapes, and measured radial trends in low-k δne/ne and δTe/Te. Low (Li and C) and mid-Z (Ca) impurity transport was also compared with these flux-matched simulations. Fully stripped, low-Z impurities are well reproduced by the gyrokinetic modeling while clear disagreement exists in comparisons with mid-Z impurities. Nonlinear gyrokinetic investigation into the Z dependence of impurity transport in the ISS conditions is also performed, demonstrating clear trends of impurity diffusion with impurity Z (both D∝Z and D∝1/Z) that vary with the radial location studied. These trends are shown to result from the local dominance of ion temperature gradient or ∇n driven trapped electron mode turbulence and may contribute to the disagreement between simulation and experiment in mid-Z impurity transport. The results of this work represent one of the most complete validation studies of the gyrokinetic model performed to date and provide an example of new capabilities for predicting performance in future fusion devices.

Physics↗

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗

Examination of synthetic gas puff imaging diagnostic data from a gyrokinetic turbulence code

A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density wavenumber spectrum measurements, synthetic diagnostic development, and tests of quasilinear turbulence modeling in the core of electron-heated DIII-D H-mode plasmas

Abstract Measurements of the turbulent density wavenumber spectrum, δ n ˆ e ( k ⊥ ) , using the Doppler Back-Scattering (DBS) diagnostic are reported from DIII-D H-mode plasmas with electron cyclotron heating as the only auxiliary heating method. These electron-heated plasmas have low collisionality, ν e ∗ < 1 , T e / T i > 1 , and zero injected torque—a regime expected to be relevant for future fusion devices. We probe density fluctuations in the core ( ρ ≈ 0.7) over a broad wavenumber range, 0.5 ⩽ k ⊥ ⩽ 16 cm −1 ( 0.1 ⩽ k ⊥ ρ s ⩽ 5 ), to characterize plasma instabilities and compare with theoretical predictions. We present a novel synthetic DBS diagnostic to relate the back-scattered power spectrum, P s ( k ⊥ ) —which is directly measured by DBS—to the underlying electron density fluctuation spectrum, δ n ˆ e ( k ⊥ ) . The synthetic DBS P s ( k ⊥ ) spectrum is calculated by combining the SCOTTY beam-tracing code with a model δ n ˆ e ( k ⊥ ) predicted either analytically or numerically. In this work we use the quasi-linear code Trapped Gyro-Landau Fluid (TGLF) to approximate the δ n ˆ e ( k ⊥ ) spectrum. We find that TGLF, using the experimental profiles, is capable of closely reproducing the DBS measurements. Both the DBS measurements and the TGLF-DBS synthetic diagnostic show a wavenumber spectrum with variable decay. The measurements show weak decay ( k −0.6 ) for k < 3.5 cm −1 , with k −2.6 at intermediate- k ( 3.5 ⩽ k ⩽ 8.5 cm −1 ), and rapid decay ( k −9.4 ) for k > 8.5 cm −1 . Scans of physics parameters using TGLF suggest that the normalized ∇ T e scale-length, R / L T e , is an important factor for distinguishing microturbulence regimes in these plasmas. A combination of DBS observations and TGLF simulations indicate that fluctuations remain peaked at ITG-scales (low k ) while R / L T e -driven TEM/ETG-type modes (intermediate/high k ) are marginally sub-dominant.

synthetic diagnostics↗

Outlier classification using autoencoders: application for fluctuation driven flows in fusion plasmas

Understanding the statistics of fluctuation driven flows in the boundary layer of magnetically confined plasmas is desired to accurately model the lifetime of the vacuum vessel components. Mirror Langmuir probes (MLPs) are a novel diagnostic that uniquely allow us to sample the plasma parameters on a time scale shorter than the characteristic time scale of their fluctuations. Sudden large-amplitude fluctuations in the plasma degrade the precision and accuracy of the plasma parameters reported by MLPs for cases in which the probe bias range is of insufficient amplitude. While some data samples can readily be classified as valid and invalid, we find that such a classification may be ambiguous for up to 40% of data sampled for the plasma parameters and bias voltages considered in this study. In this contribution, we employ an autoencoder (AE) to learn a low-dimensional representation of valid data samples. By definition, the coordinates in this space are the features that mostly characterize valid data. Ambiguous data samples are classified in this space using standard classifiers for vectorial data. In this way, we avoid defining complicated threshold rules to identify outliers, which require strong assumptions and introduce biases in the analysis. By removing the outliers that are identified in the latent low-dimensional space of the AE, we find that the average conductive and convective radial heat fluxes are between approximately 5% and 15% lower as when removing outliers identified by threshold values. For contributions to the radial heat flux due to triple correlations, the difference is up to 40%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

The fluctuation–dissipation measurement instrument at the Linac Coherent Light Source

The development of new modes at x-ray free electron lasers has inspired novel methods for studying fluctuations at different energies and timescales. For closely spaced x-ray pulses that can be varied on ultrafast time scales, we have constructed a pair of advanced instruments to conduct studies targeting quantum materials. We first describe a prototype instrument built to test the proof-of-principle of resonant magnetic scattering using ultrafast pulse pairs. This is followed by a description of a new endstation, the so-called fluctuation–dissipation measurement instrument, which was used to carry out studies with a fast area detector. In addition, we describe various types of diagnostics for single-shot contrast measurements, which can be used to normalize data on a pulse-by-pulse basis and calibrate pulse amplitude ratios, both of which are important for the study of fluctuations in materials. Furthermore, we present some new results using the instrument that demonstrates access to higher momentum resolution.

Assefa, T. A.↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗