The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor

The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.

Chan, Eugene↗

Scales of variability of bio-optical properties as observed from near-surface drifters

A drifter equipped with bio-optical sensors and an automated water sampler was deployed in the California Current as part of the coastal transition zone program to study the biological, chemical, and physical dynamics of the meandering filaments. During deployments in 1987 and 1988, measurements were made of fluorescence, downwelling irradiance, upwelling radiance, and beam attenuation using several bio-optical sensors. Samples were collected by an automated sampler for later analysis of nutrients and phytoplankton species compositon. Large-scale spatial and temporal changes in the bio-optical and biological properties of the region were driven by changes in phytoplankton species composition which, in turn, were associated with the meandering circulation. Variance spectra of the bio-optical paramenters revealed fluctuations on both diel and semidiurnal scales, perhaps associated with solar variations and internal tides, respectively. Offshore, inertial-scale fluctuations were apparent in the variance spectra of temperature, fluorescence, and beam attenuation. Although calibration samples can help remove some of these variations, these results suggest that the use of bio-optical data from unattended platforms such as moorings and drifters must be analyzed carefully. Characterization of the scaled of phytoplankton variability must account for the scales of variability in the algorithms used to convert bio-optical measurments into biological quantities.

Abbott, Mark R.↗

Let's Exploit Available Knowledge on Vegetation Fluorescence

The potential to measure vegetation fluorescence from space (1) and to derive from it direct information on the gross primary productivity (GPP) of terrestrial ecosystems is probably the most thrilling development in remote sensing and global ecology of recent years, as it moves Earth observation techniques from the detection of canopy biophysics (e.g., fraction of absorbed radiation) and biochemistry (chlorophyll and nitrogen content) to the realm of ecosystem function. The existence of a functional relationship between fluorescence and photosynthesis has been elucidated over the last decade by several laboratories, notably as part of the preliminary studies of the European Space Agency Fluorescence Explorer (FLEX) Earth Explorer Mission. The empirical observation presented by Guanter et al. (2) of a linear relationship between fluorescence radiance and GPP, however, provides the first experimental confirmation of the feasibility of the approach— already thoroughly tested at leaf level—at the desired scale, despite the confounding effects associated with the satellite detection of such a faint signal. A word of clarification is needed here. The use of fluorescence as a probe of leaf photochemistry has been a staple of plant ecophysiology for decades, rooted in a sound understanding of photosynthetic energy dissipation. However, most past studies had to rely for the interpretation of results on active (pulse-saturated) techniques, making them unsuitable for remote-sensing applications. Over recent years, however, novel process based models have been developed for the interpretation of steady-state, solar-induced fluorescence at the leaf to canopy scale (3). We are therefore in a position to move beyond the mere empirical observation of an association between GPP and fluorescence radiance. In particular, Guanter et al. (2) base their analysis on the assumption of a constant ratio between photosynthetic and fluorescence light use efficiencies (equation 3 in ref. 2).We know, however, that the ratio is not constant, but changes widely in response to light, CO2, stomatal limitations, and extreme stress (4, 5). What’s more, we can make sense of such changes, thus extracting valuable information from the very scatter that is apparent in their data. However, this process will require the availability of more tailored instruments, such as the one planned for the FLEX mission. As already stressed by Guanter et al. (2), the spatial resolution of the Global Ozone Monitoring Experiment-2 sensor (40 × 80 km) makes it difficult to compare meaningfully the fluorescence signal with ground measurements, when only 60–70% of the footprint consists of the desired land-cover type (table S1 in ref. 2), suggesting that this could be largely responsible for the low signals observed in European grasslands. Moreover, the overpass time of the MetOp-A satellite (9:30 AM) implies that fluorescence is generally measured under light-limiting conditions, when fluorescence is only marginally affected by stomatal closure even under stress conditions. This result could explain the seasonal mismatch with daily GPP observed in natural ecosystems in the absence of irrigation (figure 4 in ref. 2). We hope, therefore, that this welcome contribution to this fast-advancing field will help demonstrate the potential of the new technique, and pave the way for more refined studies under both a technological and scientific point of view.

Space↗

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi↗

Development of Carbon Flux Model Using ABI Data Over the Conterminous US

The satellite-driven carbon flux estimation has been playing important role to estimate continental-scale carbon budget. One of the biggest recent advances in the satellite-driven carbon flux modeling is utilization of high-frequent geostationary satellites to estimate diurnal cycle in carbon fluxes. The satellite based carbon flux estimation used the polar orbiting satellite sensors (e.g., Moderate Resolution Imaging Spectroradiometer (MODIS)), which allow us to observe target regions only once during the day. The new generation of geostationary satellite sensors provide frequent observations, often less than every 10 minutes. Here, we use GOES Advanced Baseline Imager (ABI) data to estimate hourly NEE over the conterminous US. We used the Terrestrial Observation Prediction System (TOPS) model for estimating hourly NEE. TOPS is a diagnostic ecosystem process model that simulates the fluxes of carbon and water through vegetation in response to climate variability. For the climate input, we developed hourly climate data using the same algorithm with NASA Earth Exchange Gridded Daily Meteorology (NEX-GDM) datasets based on machine learning techniques. The hourly climate data includes precipitation, maximum temperature, minimum temperature, dew point temperature, and solar radiation were derived from the Geostationary observations. The spatial patterns of ecosystem parameters used in TOPS are optimized using satellite Solar Induced Fluorescence (SIF) data. The high frequency GPP estimations from geostationary satellite sensors make it comparable to the instantaneous SIF data than daily GPP. We also used Ameriflux data for optimization of model parameters and the validation of the output. The derived data addresses the diurnal dynamics of carbon cycling at large scales and should help in reducing the uncertainties in carbon budget studies.

geostationary satellite↗

Hourly Carbon Fluxes Estimation Using the GOES Advanced Baseline Imager (ABI) Data Over the Conterminous USA

Tremendous efforts by Fluxnet scientists over the past few decades have made thousands of site-years of carbon flux observations available for advancing our understanding of carbon cycling in terrestrial ecosystems. One of key Fluxnet measurements is net ecosystem exchange (NEE) as it is directly related to carbon budget of terrestrial ecosystems. However, carbon flux estimation studies using satellite remote sensing have focused mainly on daily Gross Primary Production (GPP). The satellite based carbon flux estimation used the polar orbiting satellite sensors (e.g., Moderate Resolution Imaging Spectroradiometer (MODIS)), which allow us to observe target regions only once during the day. Because daily NEE is close to zero value, the carbon flux models using the polar orbiting satellite data have not been well used for NEE estimation. The new generation of geostationary satellite sensors (e.g., GOES Advanced Baesline Imager (ABI) and Himawari Advanced Himawari Imager (AHI)) provide frequent observations, often less than every 10 minutes. Here, we use GOES ABI data to estimate hourly NEE over the conterminous USA. We used the Terrestrial Observation Prediction System (TOPS) model for estimating hourly NEE. TOPS is a diagnostic ecosystem process model that simulates the fluxes of carbon and water through vegetation in response to climate variability. For the climate input, we developed hourly climate data using the same algorithm with NASA Earth Exchange Gridded Daily Meteorology (NEX-GDM) datasets based on machine learning techniques. The hourly climate data includes precipitation, maximum temperature, minimum temperature, dew point temperature, and, in particular, solar radiation that is directly derived from the Geostationary observations. The spatial patterns of ecosystem parameters used in TOPS are optimized using satellite Solar Induced Fluorescence (SIF) data. The high frequency GPP estimations from geostationary satellite sensors make it comparable to the instantaneous SIF data than daily GPP. We also used Fluxnet data for optimization of model parameters and the validation of the output. The derived data addresses the diurnal dynamics of carbon cycling at large scales and should help in reducing the uncertainties in carbon budget studies.

Geostationary satellite↗

Chlorophyll pigment concentration using spectral curvature algorithms - An evaluation of present and proposed satellite ocean color sensor bands

During the past several years symmetric three-band (460-, 490-, 520-nm) spectral curvature algorithm (SCA) has demonstrated rather accurate determination of chlorophyll pigment concentration using low-altitude airborne ocean color data. It is shown herein that the in-water asymmetric SCA, when applied to certain recently proposed OCI (NOAA-K and SPOT-3) and OCM (ERS-1) satellite ocean color bands, can adequately recover chlorophyll-like pigments. These airborne findings suggest that the proposed new ocean color sensor bands are in general satisfactorily, but not necessarily optimally, positioned to allow space evaluation of the SCA using high-precision atmospherically corrected satellite radiances. The pigment concentration recovery is not as good when existing Coastal Zone Color Scanner bands are used in the SCA. The in-water asymmetric SCA chlorophyll pigment recovery evaluations were performed using (1) airborne laser-induced chlorophyll fluorescence and (2) concurrent passive upwelled radiances. Data from a separate ocean color sensor aboard the aircraft were further used to validate the findings.

Hoge, Frank E.↗

Sounding rocket flight report, MUMP 9 and MUMP 10

The results of the launching of two-Marshall-University of Michigan Probes (MUMP 9 and MUMP 10), Nike-Tomahawk sounding rocket payloads, are summarized. The MUMP is similar to the thermosphere probe, an ejectable instrument package for studying the variability of the earth's atmospheric parameters. The MUMP 9 payload included an omegatron mass analyzer, a molecular fluorescence densitometer, a mini-tilty filter, and a lunar position sensor. This complement of instruments permitted the determination of the molecular nitrogen density and temperature in the altitude range from approximately 143 to 297 km over Wallops Island, Virginia, during January 1971. The MUMP 10 payload included an omegatron mass analyzer, an electron temperature probe, a cryogenic densitometer, and a solar position sensor. These instruments permitted the determination of the molecular nitrogen density and temperature and the charged particle density and temperature in the altitude range from approximately 145 to 290 km over Wallops Island during the afternoon preceding the MUMP 9 launch.

Grassl, H. J.↗

Sounding rocket flight report: MUMP 9 and MUMP 10

The results of the launching of two Marshall-University of Michigan Probes (MUMP 9 and MUMP 10), Nike-Tomahawk sounding rocket payloads, are summarized. The MUMP 9 paylaod included an omegatron mass analyzer, a molecular fluorescence densitometer, a mini-tilty filter, and a lunar position sensor. This complement of instruments permitted the determination of the molecular nitrogen density and temperature in the altitude range from approximately 143 to 297 km over Wallops Island, Virginia, during January 1971. The MUMP 10 payload included an omegatron mass analyzer, an electron temperature probe (Spencer, Brace, and Carignan, 1962), a cryogenic densitometer, and a solar position sensor. This complement of instruments permitted the determination of the molecular nitrogen density and temperature and the charged particle density and temperature in the altitude range from approximately 145 to 290 km over Wallops Island, Virginia, during the afternoon preceding the MUMP 9 launch in January 1971. A general description of the payload kinematics, orientation analysis, and the technique for the reduction and analysis of the data is given.

Grassl, H. J.↗

Ground-Based Measurements and Validation Protocols for Flex

The upcoming ESA Fluorescence Explorer (FLEX) mission will incorporate ground-based validations for fluorescence parameters and reflectance indices, drawing on an international network of sensors located at eddy covariance tower sites. A program has been initiated by the OPTIMISE program to develop methods and protocols for this network. A sensor system suite under evaluation by OPTIMISE includes the FLoX hyperspectral spectroradiometers. The NASA team at GSFC is participating in this experiment and we report first results from the 2017 summer measurements made above the canopy at the USDA/ARS Beltsville cornfield using the DFLoX and two other leaf-level measurement systems, the MONI-PAM and the FluoWat.

DFLOX↗

Integrated Optoelectronics for Parallel Microbioanalysis

Miniature, relatively inexpensive microbioanalytical systems ("laboratory-on-achip" devices) have been proposed for the detection of hazardous microbes and toxic chemicals. Each system of this type would include optoelectronic sensors and sensor-output-processing circuitry that would simultaneously look for the optical change, fluorescence, delayed fluorescence, or phosphorescence signatures from multiple redundant sites that have interacted with the test biomolecules in order to detect which one(s) was present in a given situation. These systems could be used in a variety of settings that could include doctors offices, hospitals, hazardous-material laboratories, biological-research laboratories, military operations, and chemical-processing plants.

Stirbl, Robert↗

Integrated-Optic Oxygen Sensors

Compact optical oxygen sensors with self-calibration capabilities are undergoing development. A sensor of this type features a single-chip, integrated-optic design implemented by photolithographic fabrication of optical waveguides in a photosensitive porous glass. The porosity serves as both a matrix for retention of an oxygen-sensitive fluorescent indicator chemical and a medium for diffusion of oxygen to the chemical from the ambient air to be monitored. Each sensor includes at least one such waveguide exposed to the atmosphere and at least one covered with metal for isolation from the atmosphere. The covered one serves as a reference channel. In operation, the concentration of oxygen is deduced from the intensity and lifetime of the fluorescence in the exposed channel, with the help of calibration data acquired via the reference channel. Because the sensory chemical is placed directly in and throughout the cross section of the light path, approximately 99 percent of the light in the waveguide is available for interaction with the chemical, in contradistinction to only about 1 percent of the light in an optical sensor that utilizes evanescentwave coupling. Hence, a sensor of this type is significantly more sensitive.

Mendoza, Edgar A.↗

Semiselective Optoelectronic Sensors for Monitoring Microbes

Sensor systems are under development for use in real-time detection and quantitation of microbes in water without need for sampling. These systems include arrays of optical sensors; miniature, portable electronic data-acquisition circuits; and optoelectronic interfaces between the sensor arrays and data-acquisition circuits. These systems are intended for original use in long-term, inline monitoring of waterborne micro-organisms in water-reclamation systems aboard future spacecraft. They could also be adapted to similar terrestrial uses with respect to municipal water supplies, stored drinking water, and swimming water; for detecting low-level biological contamination in biotechnological, semiconductor, and pharmaceutical process streams; and in verifying the safety of foods and beverages. In addition, they could be adapted to monitoring of airborne microbes and of surfaces (e.g., to detect and/or quantitate biofilms). The designs of the sensors in these systems are based partly on those of sensors developed previously for monitoring airborne biological materials. The designs exploit molecular- recognition and fluorescence-spectroscopy techniques, such that in the presence of micro-organisms of interest, fluorescence signals change and the changes can be measured. These systems are characterized as semiselective because they respond to classes of micro-organisms and can be used to discriminate among the classes. This semiselectivity is a major aspect of the design: It is important to distinguish between (1) the principle of detection and quantitation of classes of micro-organisms by use of these sensors and (2) the principle of detection and quantitation of individual microbiological species by means of prior immuno-diagnostic and/or molecular-biology techniques. Detection of classes (in contradistinction to species) is particularly valuable when the exact nature of a contaminant is unknown.

Tabacco, Mary Beth↗

High-Temperature Surface-Acoustic-Wave Transducer

Aircraft-engine rotating equipment usually operates at high temperature and stress. Non-invasive inspection of microcracks in those components poses a challenge for the non-destructive evaluation community. A low-profile ultrasonic guided wave sensor can detect cracks in situ. The key feature of the sensor is that it should withstand high temperatures and excite strong surface wave energy to inspect surface/subsurface cracks. As far as the innovators know at the time of this reporting, there is no existing sensor that is mounted to the rotor disks for crack inspection; the most often used technology includes fluorescent penetrant inspection or eddy-current probes for disassembled part inspection. An efficient, high-temperature, low-profile surface acoustic wave transducer design has been identified and tested for nondestructive evaluation of structures or materials. The development is a Sol-Gel bismuth titanate-based surface-acoustic-wave (SAW) sensor that can generate efficient surface acoustic waves for crack inspection. The produced sensor is very thin (submillimeter), and can generate surface waves up to 540 C. Finite element analysis of the SAW transducer design was performed to predict the sensor behavior, and experimental studies confirmed the results. One major uniqueness of the Sol-Gel bismuth titanate SAW sensor is that it is easy to implement to structures of various shapes. With a spray coating process, the sensor can be applied to surfaces of large curvatures. Second, the sensor is very thin (as a coating) and has very minimal effect on airflow or rotating equipment imbalance. Third, it can withstand temperatures up to 530 C, which is very useful for engine applications where high temperature is an issue.

Zhao, Xiaoliang↗

The measurement of atomic oxygen in the mesosphere and lower thermosphere

A discussion of the laboratory calibration, calibration simulation, and accuracy of a resonance fluorescence instrument for measuring oxygen atoms is presented. The discussion demonstrates that a sensor can be calibrated with good accuracy to obtain in situ measurements of the oxygen density in the mesosphere/lower thermosphere. Oxygen data are reported from six rocket flights. These data represent four midlatitude flights and two auroral flights. There are two night and two day profiles for the midlatitude experiments. The maximum densities found from these sets of data in the 90-100 km regions are between 1.5 x 10 to the 11th/cu cm and 3.5 x 10 to the 11th/cu cm. Agreement with the MSIS-86 model predictions is obtained for altitudes above 120 km for midlatitude flights. The auroral data are less than the model prediction by about a factor of 2. The data show structure that is probably indicative of gravity wave effects of a nominal 5-km vertical wavelength.

Sharp, William E.↗

Validation of Ocean Color Satellite Data Products in Under Sampled Marine Areas

The planktonic marine cyanobacterium, Trichodesmium sp., is broadly distributed throughout the oligotrophic marine tropical and sub-tropical oceans. Trichodesmium, which typically occurs in macroscopic bundles or colonies, is noteworthy for its ability to form large surface aggregations and to fix dinitrogen gas. The latter is important because primary production supported by N2 fixation can result in a net export of carbon from the surface waters to deep ocean and may therefore play a significant role in the global carbon cycle. However, information on the distribution and density of Trichodesmium from shipboard measurements through the oligotrophic oceans is very sparse. Such estimates are required to quantitatively estimate total global rates of N2 fixation. As a result current global rate estimates are highly uncertain. Thus in order to understand the broader biogeochemical importance of Trichodesmium and N2 fixation in the oceans, we need better methods to estimate the global temporal and spatial variability of this organism. One approach that holds great promise is satellite remote sensing. Satellite ocean color sensors are ideal instruments for estimating global phytoplankton biomass, especially that due to episodic blooms, because they provide relatively high frequency synoptic information over large areas. Trichodesmium has a combination of specific ultrastructural and biochemical features that lend themselves to identification of this organism by remote sensing. Specifically, these features are high backscatter due to the presence of gas vesicles, and absorption and fluorescence of phycoerythrin. The resulting optical signature is relatively unique and should be detectable with satellite ocean color sensors such as the Sea-Viewing Wide Field-of-view Sensor (SeaWiFS).

Subramaniam, Ajit↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

Rohit Bhartia↗

The fluorescence of chlorophyll and yellow substances in natural waters: A note on the problems of measurement and the importance of their remote sensing

There are two chromophylls which, if sensed remotely from high altitude, would revolutionize the ability to survey large areas of the world's oceans. The chromophylls of importance are: the photosynthetic pigments of plankton algae and a group of organic materials frequently termed dissolved yellow substances. These are derived from plants and carried into the ocean by fresh water inflow. The attenuation of light by phytoplankton is characterized by two distinctive bands (450, 675 nm) which represent absorption by chloroplastic pigments. Yellow substances are characterized by a strong ultraviolet absorption which tails over into the visible region. It is emphasized that chlorophyll determination could be a unique technique for estimating the extent of eutrophication in coastal waters, and that a high altitude observer equipped with temperature, chlorophyll and yellow substance sensors has the possibility of detecting the magnitude of eutrophication and its sources by using laser induced fluorescent devices.