Search NASA⌕ Search

SEARCH · Search NASA

Results for “force sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Practical Considerations using Weighted-Acceleration Compensation Techniques for Dynamic Force Measurements in Wind Tunnels

Most wind tunnel force measurement systems are designed and calibrated for high-accuracy static measurements, but may have limited ability to sense dynamic forces and moments. As a means to improve the measurement bandwidth of dynamic forces, researchers have proposed using a weighted-acceleration technique, which uses accelerometer data to compensate and correct for system dynamics. The sum of weighted-accelerations method is attractive as the acceleration data applies a correction to the traditional static measurements. The focus of this paper is on practical aspects of implementing a weighted-acceleration technique in an experimental arrangement. A formulation of the weighted-acceleration methodology is validated on a reduced-order model and demonstrated on a tabletop experiment that serves as a proxy to a wind tunnel force measurement system. As part of this system, a two component normal force and pitching moment balance was designed and fabricated. A static and dynamic calibration of the system was performed, and the weighted-acceleration technique was used to reconstruct impact forces acting on the system. Practical considerations of the experimental design that improve the success of the methodology are discussed.

Dynamic force measurement↗

Practical Considerations using Weighted-Acceleration Compensation Techniques for Dynamic Force Measurements in Wind Tunnels

Most wind tunnel force measurement systems are designed and calibrated for high-accuracy static measurements, but may have limited ability to sense dynamic forces and moments. As a means to improve the measurement bandwidth of dynamic forces, researchers have proposed using a weighted-acceleration technique, which uses accelerometer data to compensate and correct for system dynamics. The sum of weighted-accelerations method is attractive as the acceleration data applies a correction to the traditional static measurements. The focus of this paper is on practical aspects of implementing a weighted-acceleration technique in an experimental arrangement. A formulation of the weighted-acceleration methodology is validated on a reduced-order model and demonstrated on a tabletop experiment that serves as a proxy to a wind tunnel force measurement system. As part of this system, a two component normal force and pitching moment balance was designed and fabricated. A static and dynamic calibration of the system was performed, and the weighted-acceleration technique was used to reconstruct impact forces acting on the system. Practical considerations of the experimental design that improve the success of the methodology are discussed.

Dynamic force measurement↗

A new active virtual pivot six-degree-of-freedom hand controller for aerospace applications

During 1989 a new six-degree-of-freedom (6-DOF) active hand controller concept was designed and constructed based on the concept of a virtual pivot. This concept, labeled VPHC, was first demonstrated in a 1985 study and a patent was issued in 1990. Operator control input occurs via a force/torque sensor rigidly mounted to the handgrip. Sensed force/torque signals are used by microprocessors to generate motor drive control for each of six independently controlled motors mounted on the three-legged mechanism. The control microprocessor uses input biasing and rate-feedback motor controllers to generate the sensed feel of virtual springs and deadbands found in more conventional designs. An important advantage of this design is that the location of the virtual pivots, reflective forces and torques, breakout force levels, sensed spring rates, and operating modes, can be changed simply by changing the software. This approach yields an autonomous VPHC that can easily adapt itself to an individual operator (by software extension). A proof-of-concept version has been demonstrated, and further improvements are currently being studied and implemented.

Marshall, William C.↗

Flexible tactile sensing arrays for robotics: Architectural robustness and yield considerations

No tactile sensor array developed to date fills all, nor even most, of the requirements of: (1) many sensor elements to minimize tactile imaging time, (2) close spacing of small sensing elements for fine spatial discrimination, (3) ability to be molded to a convex fingertip surface for taction on concave surfaces, (4) ability to sense both force and temperature in order to fully mimic biological touch, (5) tolerance to overscale forces without damage, and (6) graceful failure in use, i.e., functional survival of most of the array when part of it is damaged, well. Several investigators have recently developed tactile sensing arrays suitable for imaging shapes on hard flat surfaces, but not well suited for taction on curved surfaces. Others have developed single tactile sensors suitable for incorporation into arrays, which will probably prove uneconomical when large numbers of sensors are needed. Still others have developed flexible capacitive arrays suitable for use on curved surfaces but incapable of obtaining temperature or proximity data. A technology is being developed herein suitable to the achievement of all of the above goals, and to incrementally demonstrate useful steps toward those goals.

Barth, Phillip W.↗

Method and Apparatus for Characterizing Pressure Sensors using Modulated Light Beam Pressure

Embodiments of apparatuses and methods are provided that use light sources instead of sound sources for characterizing and calibrating sensors for measuring small pressures to mitigate many of the problems with using sound sources. In one embodiment an apparatus has a light source for directing a beam of light on a sensing surface of a pressure sensor for exerting a force on the sensing surface. The pressure sensor generates an electrical signal indicative of the force exerted on the sensing surface. A modulator modulates the beam of light. A signal processor is electrically coupled to the pressure sensor for receiving the electrical signal.

Robert C Youngquist↗

Using the Space Glove to Teach Spatial Thinking

The challenge of extending students' skills in spatial thinking to astronomical scales was the central focus of our K-8 curriculum development. When the project's lead teacher requested a curriculum that cumulatively built on each prior year's learning in a spiral fashion, I knew exactly what the school was asking for. Second and third graders began by noticing the cyclical patters that the sun, moon, and stars make in the sky. Fourth graders explored the phases of the moon by taking turns modeling and sketching them in their classroom and then comparing them to the real sky. Sixth !graders used real telescopes to observe a moving model of our solar system and walked a scale model of the planets' orbits. The curriculum is designed to expand students' capacity to visualize space in a hierarchical fashion that asks them to imagine themselves from a broader number of spatial perspectives through hands-on activities. The "situational awareness" Peter's story describes is a hallmark of high-performance engineering and innovation. Keeping in mind the potential outcomes of multiple paths of pursuit from multiple perspectives while keeping track of their relative merits and performance requirements is a demanding spatial task. What made it possible for Peter to transform the failure of his first glove into triumph was the mental space in which that failure provided exactly the information needed for a new breakthrough. In at least two cases, Peter could immediately "see" the full implications of what his hands were telling him. He tells the story of how putting his hands in a Phase VI astronaut glove instantly transformed his understanding of the glove challenge. Six months into his development, the failure of circumferentially wrapped cords to produce a sufficiently flexible glove again forced him to abandon his assumptions. His situational awareness was so clear and compelling it became a gut-level response. Peter's finely developed spatial skills enabled him to almost instinctively focus his full energy on a carefully constructed set of experiments. The finger's ability to sense pressure, force, and work gave him the immediate feedback required to solve this one central problem. Once properly understood, his failure quickly led to the magical "Aha!" moment of discovery; the rest is history. Just as children need opportunities to develop hands-on understanding, engineers need to explore new possibilities through incremental hands-on failure. High-performance innovation is all about learning to make maximum use of thinking spatially to direct this process. Peter Homer's glove also reminds us that efficient engineering decisions need to be made as close to the hardware as possible. Whether we're doing hands-on education or hands-on engineering, it is when we trust in our ability to "feel our way" through failure that we reach our highest potential.

Lord, Peter↗

Hall devices improve electric motor efficiency

Efficiency of electric motors and generators is reduced by radial magnetic forces created by symmetric fields within device. Forces are sensed and counteracted by Hall devices on excitation or control windings. Hall generators directly measure and provide compensating control of anu asymmetry, eliminating additional measurements needed for calibration feedback control loop.

Haeussermann, W.↗

System and method for moving a probe to follow movements of tissue

An apparatus is described for moving a probe that engages moving living tissue such as a heart or an artery that is penetrated by the probe, which moves the probe in synchronism with the tissue to maintain the probe at a constant location with respect to the tissue. The apparatus includes a servo positioner which moves a servo member to maintain a constant distance from a sensed object while applying very little force to the sensed object, and a follower having a stirrup at one end resting on a surface of the living tissue and another end carrying a sensed object adjacent to the servo member. A probe holder has one end mounted on the servo member and another end which holds the probe.

Feldstein, C.↗

Large-gap magnetic positioning system having advantageous configuration

A magnetic configuration was devised in which the positioned object is maintained in a stable orientation and position on one side of an opaque plane surface entirely by means of magnetic components on the other side of the plane. The system is effective with or without gravity, and can operate in any orientation. In this system, the positioned object need only contain a simple dipole magnet. The positioning components consist of a group of permanent magnets creating a magnetic field configuration which stabilizes the levitated dipole in all but one degree of freedom, and a magnetic position sensing and force feedback system to actively stabilize the object in the one unstable direction. The system utilizes very low power at equilibrium and can maintain gaps of 50 mm.

Chong, Paul↗

Effects of cockpit lateral stick characteristics on handling qualities and pilot dynamics

This report presents the results of analysis of cockpit lateral control feel-system studies. Variations in feel-system natural frequency, damping, and command sensing reference (force and position) were investigated, in combination with variations in the aircraft response characteristics. The primary data for the report were obtained from a flight investigation conducted with a variable-stability airplane, with additional information taken from other flight experiments and ground-based simulations for both airplanes and helicopters . The study consisted of analysis of handling qualities ratings and extraction of open-loop, pilot-vehicle describing functions from sum-of-sines tracking data, including, for a limited subset of these data, the development of pilot models. The study confirms the findings of other investigators that the effects on pilot opinion of cockpit feel-system dynamics are not equivalent to a comparable level of added time delay, and until a more comprehensive set of criteria are developed, it is recommended that feel-system dynamics be considered a delay-inducing element in the aircraft response. The best correlation with time-delay requirements was found when the feel-system dynamics were included in the delay measurements, regardless of the command reference. This is a radical departure from past approaches.

Mitchell, David G.↗

Power assist EVA glove development

Structural modeling of the EVA glove indicates that flexibility in the metacarpophalangeal (MCP) joint can be improved by selectively lowering the elasticity of the glove fabric. Two strategies are used to accomplish this. One method uses coil springs on the back of the glove to carry the tension in the glove skin due to pressurization. These springs carry the loads normally borne by the glove fabric, but are more easily deformed. An active system was also designed for the same purpose and uses gas filled bladders attached to the back of the EVA glove that change the dimensions of the back of the glove and allow the glove to bend at the MCP joint, thus providing greater flexibility at this joint. A threshold control scheme was devised to control the action of the joint actuators. Input to the controller was provided by thin resistive pressure sensors placed between the hand and the pressurized glove. The pressure sensors consist of a layer of polyester film that has a thin layer of ink screened on the surface. The resistivity of the ink is pressure dependent, so an extremely thin pressure sensor can be fabricated by covering the ink patch with another layer of polyester film and measuring the changing resistance of the ink with a bridge circuit. In order to sense the force between the hand and the glove at the MCP joint, a sensor was placed on the palmar face of the middle finger. The resultant signal was used by the controller to decide whether to fill or exhaust the bladder actuators on the back of the glove. The information from the sensor can also be used to evaluate the effectiveness of a given control scheme or glove design since the magnitude of the measured pressures gives some idea of the torque required to bend a glove finger at the MCP joint. Tests of this actuator, sensor, and control system were conducted in an 57.2 kPa glove box by performing a series of 90 degree finger bends with a glove without an MCP joint assembly, a glove with the coil spring assembly, and with the four fingered actuated glove. The tests of these three glove designs confirm the validity of the model.

Main, John A.↗

Closed-Loop Control System for Friction Stir Welding Retractable Pin Tool

NASA invention disclosure, NASA Case No. MFS-31413, entitled "System for Controlling the Stirring Pin of a Friction Stir Welding Apparatus", (Patent Pending) authored by Jeff Ding, Dr Peter Romine and Pete Oelgoetz, addresses the precision control of the friction stir welding process. The closed-loop control system automatically adjusts the spinning welding pin, real-time, to maintain a precise penetration ligament (i.e., distance between pin-tip and weld panel backside surface). A specific pin length can be maintained while welding constant thickness or tapered material thickness weld panels. The closed-loop control system provides operator data and information relative to the exact position of the welding pin inside the weld joint. This paper presents the closed-loop RPT control system that operates using the auto-feedback of force signals sensed by the tip and shoulder of the welding pin. Significance: The FSW process can be successfully used in a production environment only if there is a method or technique that informs the FSW operator the precise location of the welding pin inside the weld joint. This is essential for applications in aerospace, automotive, pressure vessel, commercial aircraft and other industries.

Ding, R. Jeffrey↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher-frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

The effect of acute microgravity on mechanically-induced membrane damage and membrane-membrane fusion events

Although it is unclear how a living cell senses gravitational forces there is no doubt that perturbation of the gravitational environment results in profound alterations in cellular function. In the present study, we have focused our attention on how acute microgravity exposure during parabolic flight affects the skeletal muscle cell plasma membrane (i.e. sarcolemma), with specific reference to a mechanically-reactive signaling mechanism known as mechanically-induced membrane disruption or "wounding". Both membrane rupture and membrane resealing events mediated by membrane-membrane fusion characterize this response. We here present experimental evidence that acute microgravity exposure can inhibit membrane-membrane fusion events essential for the resealing of sarcolemmal wounds in individual human myoblasts. Additional evidence to support this contention comes from experimental studies that demonstrate acute microgravity exposure also inhibits secretagogue-stimulated intracellular vesicle fusion with the plasma membrane in HL-60 cells. Based on our own observations and those of other investigators in a variety of ground-based models of membrane wounding and membrane-membrane fusion, we suggest that the disruption in the membrane resealing process observed during acute microgravity is consistent with a microgravity-induced decrease in membrane order.

Parabolic Flight↗

The Effect of Acute Microgravity on Mechanically-Induced Membrane Damage and Membrane-Membrane Fusion Events

Although it is unclear how a living cell senses gravitational forces there is no doubt that perturbation of the gravitational environment results in profound alterations in cellular function. In the present study, we have focused our attention on how acute microgravity exposure during parabolic flight affects the skeletal muscle cell plasma membrane (i.e. sarcolemma), with specific reference to a mechanically-reactive signaling mechanism known as mechanically-induced membrane disruption or "wounding". This response is characterized by both membrane rupture and membrane resealing events mediated by membrane-membrane fusion. We here present experimental evidence that acute microgravity exposure can inhibit membrane-membrane fusion events essential for the resealing of sarcolemmal wounds in individual human myoblasts. Additional evidence to support this contention comes from experimental studies that demonstrate acute microgravity exposure also inhibits secretagogue-stimulated intracellular vesicle fusion with the plasma membrane in HL-60 cells. Based on our own observations and those of other investigators in a variety of ground-based models of membrane wounding and membrane-membrane fusion, we suggest that the disruption in the membrane resealing process observed during acute microgravity is consistent with a microgravity-induced decrease in membrane order.

Clarke, Mark, S. F.↗

Mid-Air Helicopter Delivery at Mars Using a Jetpack

Mid-Air Helicopter Delivery (MAHD) is a new Entry, Descent and Landing (EDL) architecture to enable in situ mobility for Mars science at lower cost than previous rover missions. It uses a jetpack to slow down a Mars Science Helicopter (MSH) after separation from the backshell, and reach aerodynamic conditions suitable for helicopter take-off in mid air. MAHD's lander-free approach leaves enough room in the aeroshell to accommodate larger rotors. This drastically improves flight performance compared to heritage EDL approaches, notably +60\% science payload mass. MAHD also brings cost savings, a simpler architecture, improved surface access and can reach higher elevations on Mars. This paper introduces a design for the MAHD system architecture and operations. We present a mechanical configuration which fits both MSH and the jetpack within the 2.65-m Mars heritage aeroshell, and a jetpack control architecture which fully leverages the available helicopter avionics. We discuss preliminary numerical models of the flow dynamics resulting from the interaction between the jets, the rotors and the side winds. We define a force-torque sensing architecture capable of handling the wind and trimming the rotors to prepare for safe take-off. Finally, we analyze the dynamic environment and closed-loop control simulation results to demonstrate the preliminary feasibility of MAHD.

Balaram, J.↗

Remote Sensing of Aerosol and Aerosol Radiative Forcing of Climate from EOS Terra MODIS Instrument

The recent launch of EOS-Terra into polar orbit has begun to revolutionize remote sensing of aerosol and their effect on climate. Terra has five instruments, two of them,Moderate Resolution Imaging Spectroradiometer (MODIS) and Multiangle Imaging Spectro-Radiometer (MISR) are designed to monitor global aerosol in two different complementary ways. Here we shall discuss the use of the multispectral measurements of MODIS to derive: (1) the global distribution of aerosol load (and optical thickness) over ocean and land; (2) to measure the impact of aerosol on reflection of sunlight to space; and (3) to measure the ability of aerosol to absorb solar radiation. These measurements have direct applications on the understanding of the effect of aerosol on climate, the ability to predict climate change, and on the monitoring of dust episodes and man-made pollution. Principles of remote sensing of aerosol from MODIS will be discussed and first examples of measurements from MODIS will be provided.

Kaufman, Yoram↗