It's About Time!

Everything we do in VLBI is connected to time. In this contribution, we review 28 orders of magnitude of the spectrum of time ranging from a few hundred femtoseconds (i.e. one degree of phase at X-band - Pi x 10(exp -13) seconds) upwards to tens of millions of years (i.e. ten million years Pi x 10(exp 14) seconds). In this discussion, we will pay special attention to the relation between the underlying oscillator (the frequency standard that defines a clock's rate) and the time kept by the clock (which counts the oscillations of the frequency standard). We will consider two different types of time - time kept by counting an atomic frequency standard (Hydrogen Maser or Cesium), and time reckoned by the rotation of the Earth underneath the stars and sun.

Clark, Tom↗

Four-Sector Cylindrical Radio-Frequency Ion Trap

Proposed linear radio-frequency ion trap consists of closed metal cylinder partitioned into four equal cylindrical-sector electrodes and two circular end electrodes. Features include relatively large ion-storage capacity and shielding against external fields. Used in frequency-standard laboratories to confine 199Hg+ ions electrodynamically in isolation from external environment. Similar to device described in "Linear Ion Trap for Atomic Clock" (NPO-17758).

Melbourne, Ruthann K.↗

Repetitive Interrogation of 2-Level Quantum Systems

Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

Rabi interrogation↗

An analytic technique for statistically modeling random atomic clock errors in estimation

Minimum variance estimation requires that the statistics of random observation errors be modeled properly. If measurements are derived through the use of atomic frequency standards, then one source of error affecting the observable is random fluctuation in frequency. This is the case, for example, with range and integrated Doppler measurements from satellites of the Global Positioning and baseline determination for geodynamic applications. An analytic method is presented which approximates the statistics of this random process. The procedure starts with a model of the Allan variance for a particular oscillator and develops the statistics of range and integrated Doppler measurements. A series of five first order Markov processes is used to approximate the power spectral density obtained from the Allan variance.

Fell, P. J.↗

Investigations of laser pumped gas cell atomic frequency standard

The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported.

Volk, C. H.↗

Stochastic models for atomic clocks

For the atomic clocks used in the National Bureau of Standards Time Scales, an adequate model is the superposition of white FM, random walk FM, and linear frequency drift for times longer than about one minute. The model was tested on several clocks using maximum likelihood techniques for parameter estimation and the residuals were acceptably random. Conventional diagnostics indicate that additional model elements contribute no significant improvement to the model even at the expense of the added model complexity.

Barnes, J. A.↗

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

A rubidium clock for SEEK-TALK

The development of a tactical rubidium frequency standard (TRFS) for the SEEK-TALK program is discussed. This effort, which is entering the prototype stage, is directed toward the establishment of a production capability for miniature rubidium clocks of medium stability capable of fast warmup and extreme ruggedness for military avionics applications. The overall unit consists of an ultraminiature physics package and four plug-in circuit boards inside a 2 1/2-inch square by 4-inch box. This size is achieved without the extensive use of hybrid microcircuitry, yet is believed to be the smallest atomic frequency standard yet developed.

Riley, W. J.↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Ultralight dark matter detection with mechanical quantum sensors

Abstract We consider the use of quantum-limited mechanical force sensors to detect ultralight (sub-meV) dark matter (DM) candidates which are weakly coupled to the standard model. We show that mechanical sensors with masses around or below the milligram scale, operating around the standard quantum limit, would enable novel searches for DM with natural frequencies around the kHz scale. This would complement existing strategies based on torsion balances, atom interferometers, and atomic clock systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

A high-performance Hg(+) trapped ion frequency standard

A high-performance frequency standard based on (199)Hg(+) ions confined in a hybrid radio frequency (RF)/dc linear ion trap is demonstrated. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. A 160-mHz-wide atomic resonance line for the 40.5-GHz clock transition is used to steer the output of a 5-mHz crystal oscillator to obtain a stability of 2 x 10(exp -15) for 24,000-second averaging times. Measurements with a 37-mHz line width for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is better than 1 x 10(exp -15) at 10,000-second averaging times.

Prestage, J. D.↗

Spaceborne clock system: Some alternatives for a proposed NASA experiment

A spaceborne clock experiment is proposed with the objectives of improving international time and frequency comparisons, studying precise one-way Doppler tracking and one-way ranging techniques, performing relativistic studies, and developing new atomic frequency standards technology. Various alternatives are considered for accomplishing these goals, including the use of existing satellite and earth-based time dissemination systems as well as the development of a new frequency standard for this specific application. One conclusion is that several attractive alternatives already exist for meeting the goal of improved time and frequency dissemination. However, to achieve all the other 4 goals at the NASA-stated levels of accuracy, a spaceborne atomic frequency standard may be required. An analysis of achievements to date with quartz oscillators, rubidium standards, cesium beam standards, hydrogen masers, and several other possibilities leads to the conclusion that cesium and rubidium standards offer the best choices for the experiment as proposed by NASA. The greatest obstacle to a spaceborne atomic standard appears to be its electrical power requirements.

Beehler, R. E.↗

GPS Monitor Station Upgrade Program at the Naval Research Laboratory

One of the measurements made by the Global Positioning System (GPS) monitor stations is to measure the continuous pseudo-range of all the passing GPS satellites. The pseudo-range contains GPS and monitor station clock errors as well as GPS satellite navigation errors. Currently the time at the GPS monitor station is obtained from the GPS constellation and has an inherent inaccuracy as a result. Improved timing accuracy at the GPS monitoring stations will improve GPS performance. The US Naval Research Laboratory (NRL) is developing hardware and software for the GPS monitor station upgrade program to improve the monitor station clock accuracy. This upgrade will allow a method independent of the GPS satellite constellation of measuring and correcting monitor station time to US Naval Observatory (USNO) time. THe hardware consists of a high performance atomic cesium frequency standard (CFS) and a computer which is used to ensemble the CFS with the two CFS's currently located at the monitor station by use of a dual-mixer system. The dual-mixer system achieves phase measurements between the high-performance CFS and the existing monitor station CFS's to within 400 femtoseconds. Time transfer between USNO and a given monitor station is achieved via a two way satellite time transfer modem. The computer at the monitor station disciplines the CFS based on a comparison of one pulse per second sent from the master site at USNO. The monitor station computer is also used to perform housekeeping functions, as well as recording the health status of all three CFS's. This information is sent to the USNO through the time transfer modem. Laboratory time synchronization results in the sub nanosecond range have been observed and the ability to maintain the monitor station CFS frequency to within 3.0 x 10 (sup minus 14) of the master site at USNO.

Galysh, Ivan J.↗

UTC Dissemination to the Real-Time User

The current definition of Coordinated Universal Time (UTC) dates from 1972. The duration of a UTC second is defined in terms of the frequency of a hyperfine transition in the ground state of cesium. This standard frequency is realized in a number of different laboratories using ensembles of commercial cesium clocks and a few primary frequency standards. The data from all of these devices are transmitted periodically to the Bureau International des Poids et Mesures (BIPM) in Sevres, France, where they are combined in a statistical procedure to produce International Atomic Time (TAI). The time of this scale is adjusted as needed ('coordinated') by adding or dropping integer seconds so as to keep it within plus or minus 0.9 s of UT1, a time scale based on the observation of the transit times of stars and corrected for the predicted seasonal variations in these observations. When the leap seconds are included into TAI, the result is called UTC. The difference between TAI and UTC is therefore an exact integer number of seconds. This difference is currently 29 s and will become 30 s at 0 UTC on 1 January 1996.

Levine, Judah↗

Atomic Coherence of 2 Minutes and Instability of 1.5 × 10 −18 at 1 s in a Wannier-Stark Lattice Clock

We explore the limits of atomic coherence and measurement precision in a 87 Sr optical lattice clock. We perform a detailed characterization of key effects, including lattice Raman scattering and atomic collisions in a shallow lattice configuration, determining a 174(28) s 3 𝑃 0 clock state lifetime. Investigation of atomic coherence across a range of lattice depths and atomic densities reveals decoherence mechanisms related to photon scattering and atomic interaction. At a reduced density, we observe a coherence time of 118(9) s, approaching the fundamental limit set by spontaneous emission. Guided by this coherence understanding, we demonstrate a clock instability for an atomic ensemble of 1.5 × 10 −18 at 1 s in fractional frequency units. Our results are important for further advancing the state of the art of an optical lattice clock for fundamental physics applications.

atomic, optical, & lattice clocks↗

The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements

Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

Wang, H. T.↗

Frequency comparisons via GPS carrier-phase: jump processing, temperature compensation and zero/short-baseline noise-floors

GPS carrier-phase receivers have been used to produce high quality time/frequency comparisons between clocks and frequency standards. Current ways of processing the carrier-phase data, however, result in phase jumps and data gaps that make the data difficult to use effectively and repeatedly for long datasets. In addition, temperature fluctuations generally perturb receiver output detrimentally. We describe the steps of a simple but effective automated algorithm for comparing frequencies that can compensate for data gaps, day boundary jumps, and other phase jumps as well as for temperature disturbances. We describe process features and focus on zero-baseline noise-floors, measuring Allan deviations of the Deep Space Atomic Clock mission’s receiver down to 1x10-17 at 5x105 seconds, with an upper confidence level of 3x10-17. The zero-baseline noise floors we present give confidence in our algorithm and temperature compensation’s robustness.

Diener, William A.↗