Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

System, algorithm, and method using short pulse interrogation with neutrons to detect and identify matter

A system, method, and algorithm for detecting and identifying special nuclear material (SNM) (including fissionable material), explosives, or drugs is disclosed. This material detection system relies on active interrogation of material using a short, intense neutron pulse, and characterization of the resulting prompt gamma response in two short time windows, the first concurrent with and the second immediately following the end of the neutron pulse, optionally subject to a total transit delay time of the neutrons from the neutron source to the target and from the target to the gamma detector. A high data rate analysis system implements data stream analysis and statistical correlations of the two short time window gamma responses to rapidly detect or identify SNM, explosives, or drugs. The duration of the neutron pulse is so short that minimal dose results. Various shields help to minimize the background signal falling on the gamma detector to improve sensitivity.

Derzon, Mark S.↗

Application of Hybrid K-Edge Densitometry in Reprocessing Facilities

During reprocessing operations, accurately determining the elemental concentrations of uranium and plutonium is critical for nuclear security. Reprocessing facilities processes hundreds of tons of nuclear material annually, requiring accurate measurements to ensure effective nuclear material control and accountability. Hybrid K-edge densitometry (HKED) system combines K-edge absorption densitometry with x-ray fluorescence to measure actinide elemental concentrations with a low uncertainty. This system uses high-purity germanium gamma-ray detectors and advanced signal processing equipment to detect x-ray accurately. This document provides guidance on how to achieve effective performance from an HKED system for measuring uranium and plutonium concentrations in reprocessing facilities. It includes best practices for the setup and operation of an HKED system, while highlighting factors influencing uncertainties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sealed position sensitive hard X-ray detector having large drift region for all sky camera with high angular resolution

A sealed position sensitive proportional counter filled with two atmospheres of 95% xenon and 5% methane, and containing a drift region of 24 atm cm, has operated in a stable manner for many months. The detector contains G-10 frames to support the anode and cathode wires. The detector was sealed successfully by a combination of vacuum baking the G-10 frames at 150 C for two weeks followed by assembly into the detector in an environment of dry nitrogen, and the use of passive internal getters. The counter is intended for use with a circumferential cylindrical collimator. Together they provide a very broad field of view detection system with the ability to locate cosmic hard X-ray and soft gamma ray sources to an angular precision of a minute of arc. A set of instruments based on this principle have been proposed for satellites to detect and precisely locate cosmic gamma ray bursts.

Gorenstein, P.↗

Real-Time Optical Flux Limits from Gamma-Ray Bursts Measured by the Gamma-Ray Optical Counterpart Search Experiment

The Gamma-Ray Optical Counterpart Search Experiment presents new experimental upper limits on the optical flux from gamma-ray bursts (GRBs). Our experiment consisted of a fully automated very wide-field opto-electronic detection system that imaged locations of GRBs within a few seconds of receiving trigger signals provided by BATSE's real-time burst coordinate distribution network. The experiment acquired 3800 observing hours, recording 22 gamma-ray burst triggers within approx. 30 s of the start of the burst event. Some of these bursts were imaged while gamma-ray radiation was being detected by BATSE. We identified no optical counterparts associated with gamma-ray bursts among these events at the mV approx. 7.0-8.3 sensitivity level. We find the ratio of the upper limit to the V-band optical flux, F nu, to the gamma-ray fluence, Phi gamma, from these data to be 1 x 10(exp-18) less than F nu Phi gamma less than 2 x 10(exp -16).

Park, H. S.↗

Questionnaire for Radioisotope Identification and Estimation from Gamma Spectra using PyRIID v2

Accurate targeting of radioisotope classifiers and estimators requires an understanding of the target problem space. In order to facilitate clear communication on expected model behavior and performance between practitioners and stakeholders on their problems, this questionnaire was created. Stakeholder responses form the basis of a trained model as well as the start of usage requirements for the model as it is integrated with analysis processes or detection systems. This questionnaire may also be useful to machine learning practitioners and gamma spectroscopists developing new algorithms as a starting point for characterizing their problem space, especially if they are using PyRIID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Bright Gamma-Ray Transient GRO J1838-0145: Multiwavelength Studies of X-Ray Novae

We completed the observational work regarding the bright gamma-ray transient GRO J1838-014 that might be a representative of a new class of gamma-ray sources in our Galaxy. A bright gamma-ray flare was detected by EGRET in June 1996. Its time variability (approx. weeks) and the absence of a clearly identified radio-loud (-approx. 1 Jy) blazar in its error box are crucial for our interpretation of GRO J1838-014 as an object different from gamma-ray blazars or isolated pulsars. We also observed the error box with ASCA and SAX pointings without identifying obvious candidate counterparts. The X-ray flux in quiescence, if any, is quite low, and canonical X-ray binary systems are also excluded. GRO J1838-014 is not the only non-blazar gamma-ray transients detected by EGRET in the Galactic plane. An analysis of CGRO Cycle 4 data is being completed in collaboration with R. Mukherjee and J. Mattox with the discussion of other interesting unidentified sources. Pulsars embedded in transient gaseous surroundings (maybe in binary systems) or compact objects in special systems are plausible candidates. A theoretical analysis is being developed. We also continued the study of Galactic X-ray novae, in particular of systems producing radio jets such as GRS 1915+10. The use of Green Bank Interferometer data (of which the MT is the chair of the executive committee) has been of great use to GRO and other satellite missions. We completed a study of X-ray/radio outbursts of GRS 1915+10 with BSAX and Ryle radiotelescope data and CGRO/BATSE simultaneous data. We also continued our theoretical work on gamma-ray bursts.

Tavani, Marco↗

Fixed-Energy Response-Function Analysis with Multi-Efficiency (FRAM) Software, Version 6

Researchers at Los Alamos National Laboratory have developed FixedEnergy Response- Function Analysis with Multiple Efficiency (FRAM), a powerful software tool for gamma-ray spectrometry isotopic analysis. This tool leverages Los Alamos expertise in nuclear safeguards, radiation detection systems, and related analysis techniques. A household name in the non-destructive assay community for over two decades, FRAM determines a special nuclear material source's isotopic composition by analyzing gamma-ray spectra. Los Alamos researchers have released the latest version of FRAM that incorporates several updates to the 2013 major release of FRAM, Version 5.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Energy Emission From Millisecond Pulsars

Emission at X-ray and gamma-ray energies has been detected from millisecond pulsars, both isolated and in binary systems. Although these pulsars have low surface magnetic fields, their short periods allow them to have large magnetospheric potential drops, so that high-energy emission from these sources is not unexpected. In fact, several nearby energetic millisecond pulsars that have been detected in X-rays could easily have been detected in gamma-rays by EGRET, but they were not. The reason for this may lie in a high-energy spectrum that is very different in these sources from that of normal pulsars. Both polar cap and outer gap models predict a two-component spectrum, one component peaking in hard X-rays and the other peaking above 1 GeV, with a gap at EGRET peak sensitivity. I will discuss the models for high-energy emission from millisecond pulsars, highlighting the differences between polar cap and outer gap models in spectrum and geometry of the emission.

Harding, Alice K.↗

Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory

For this study, ultra-low-level measurements of radionuclides in air have been conducted at the Savannah River National Laboratory (SRNL) to determine the atmospheric concentration of fission products released following the Fukushima Daiichi reactor accident on March 11, 2011. Air filter samples were acquired from two high-volume collection systems (a traditional filter-based system and an electrostatic precipitator-based system) to monitor airborne radionuclide concentrations in the period covering from 2 weeks to 3 years after the disaster. The world-wide spread of low-level concentrations of airborne fission products from the Fukushima event provided a unique opportunity to demonstrate SRNL's electrostatic particle collection technology and other improvements in environmental monitoring developed at the Savannah River Site (SRS). Detecting and analyzing the release allowed a comprehensive test of SRS systems for monitoring environmental radioactivity. Gamma-ray-emitting fission products ( 131,132 I, 134,136,137 Cs, and 129,132 Te) and cosmogenic isotopes ( 7 Be and 22 Na) in air were detected and quantified by high-resolution gamma-ray spectroscopy at concentrations as low as 0.07 μBq per standard cubic meter (SCM) (50 mBq total 137 Cs), while plutonium content was quantified by thermal ionization mass spectrometry (TIMS) at concentrations as low as 6.5 × 10 –21 g/SCM (3.0 fg 239+240 Pu). Isotope concentrations measured at SRNL from gamma-ray spectroscopy were compared to independent measurements from Chapel Hill, NC, located approximately 370 km (230 mi) NE of SRNL. Meteorological modeling was also used to predict radionuclide transport from the location of release to both measurement locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Mixed Material Scintillator Systems for Neutron Detection

Scintillators are a fundamental technology that enables radiation detection. Their use has historically enabled the detection of incoming gamma radiation, with recent advances in plastic scintillator development enabling detection and discrimination of neutron and gamma radiation through pulse shape discrimination. However, scintillators have so far consisted of a single material, typically one primary dye and one secondary dye embedded in a plastic matrix. Based on the simulation studies described previously, mixed material scintillator systems with multiple secondary dyes arranged in alternating, periodic micro-sized regions opens the door for scintillators with a wide variety of different capability, such as directional sensing, positional reconstruction, particle identification, and pulse shape discrimination. However, fabrication of a mixed material scintillator system by conventional manufacturing methods is difficult to manufacture and scale, creating a barrier to their wide spread implementation. On the other hand, additive manufacturing additive manufacturing presents itself as the optimal method for fabricating mixed material scintillator systems based on its flexibility, ability to fabricate fine features, and potential for multimaterial fabrication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma ray lines from novae

Activities identify the mechanisms responsible for the eruptions characterizing cataclysmic variables are concerned with close binary systems, the properties of which are dominated by the presence of mass transfer from a late-type star onto a white dwarf via an accretion disk. Theories for the outbursts vary in their identification of the eruption mechanism with either gravitational or nuclear energy sources. Existing models for the dwarf novae invoke a dynamical instability in the envelope of the red star which triggers episodic Roche lobe overflow and a concomitant increase in the rate of mass transfer and the outbursts are associated with an increase in the accretion luminosity liberated in the disk. The most successful theoretical models for common nova events involve thermonuclear runaways proceeding in accreted hydrogen envelopes on the white dwarf components of these systems. The characteristics of such runaway events, which can give rise to detectable gamma ray fluxes are discussed. Salient features of existing runaway models are reviewed. Gamma fluxes from Na-22 decay, positron annihilation, and shock induction are predicted.

Truran, J. W.↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Extension of Cable Electrical Assessment Techniques to Detect and Discriminate Radiation Aging on Cable Insulation Systems (Abstract)

The purpose of this study of the electrical responses of gamma radiation aged low voltage nuclear cables is to advance tools to determine cable condition (extent of damage) and identify degradation location along the cable length. The developed technology will provide nuclear plant operators with the options to focus cable repair, mitigation, or replacement efforts locally and avoid wholesale cable replacement.

42 ENGINEERING↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrumental technique in X-ray astronomy

A detailed review of the development of instruments for X-ray astronomy is given with major emphasis on nonfocusing high-sensitivity counter techniques used to detect cosmic photons in the energy range between 0.20 and 300 keV. The present status of X-ray astronomy is summarized together with significant results of the Uhuru observations, and photon interactions of importance for the detection of X-rays in space are noted. The three principal devices used in X-ray astronomy (proportional, scintillation, and solid-state counters) are described in detail, data-processing systems for these devices are briefly discussed, and the statistics of nuclear counting as applied to X-ray astronomy is outlined analytically. Effects of the near-earth X-ray environment and atmospheric gamma-ray production on X-ray detection by low-orbit satellites are considered. Several contemporary instruments are described (proportional-counter systems, scintillation-counter telescopes, modulation collimators), and X-ray astronomical satellite missions are tabulated.

Peterson, L. E.↗