Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas composition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Clouds and wet removal as causes of variability in the trace-gas composition of the marine troposphere

A modeling study of the effects of clouds and wet removal on the chemistry of the remote marine troposphere is described. Using a time-dependent model with parameterized vertical transport to calculate trace-gas concentrations, it is found that large variations in key species (e.g., HNO3, H2CO, and H2O2) result from simulations of sporadic rainfall, changes in cloud cover, and external inputs such as surface NO sources. Depending on the frequency and intensity of an event, the effects of these perturbations may persist for several days, thereby invalidating assumptions of photochemical equilibrium in the interpretation of measurements. Long-term integrations with fixed boundary conditions and regularly occurring cloud and rain episodes demonstrate a strong sensitivity of the mean concentration of longer-lived soluble gases to precipitation frequency but also confirm the validity of using properly chosen parameterizations of wet removal in steady state calculations.

Thompson, A. M.↗

PDMS ‐silica composite gas separation membranes by direct ink writing

Abstract Polydimethylsiloxane (PDMS)‐based membranes containing amine‐functionalized and unfunctionalized silica particles were fabricated via direct ink writing for CO 2 /N 2 gas separation. The printability of the inks was evaluated by rheological measurements, while spectroscopy, microscopy, thermal measurements, and mechanical testing were employed to characterize the printed membranes. The surface morphology of the membranes revealed the absence of voids, demonstrating their suitability for gas separation. The printed membranes also exhibited desirable thermal and mechanical properties (i.e., thermal degradation temperature of 518 °C and tensile strength as high as 1.178 MPa with 529% elongation). The PDMS‐based membranes generally displayed high permeability for CO 2 but slightly low selectivity for the CO 2 /N 2 gas pair. The best‐combined permeability‐selectivity performance of 8794 barrer and selectivity of 11.64 was demonstrated by the printed PDMS membrane containing no SiO 2 fillers. The inclusion of unfunctionalized SiO 2 particles generally increased the membrane's gas permeability but compromised the selectivity. In contrast, membranes with amine‐functionalized silica showed improved selectivity compared to membranes containing unfunctionalized silica. Overall, the performance and characteristics offered by the PDMS/silica composite membranes demonstrated the potential of 3D printing as an economical and sustainable fabrication approach to developing materials for carbon capture applications.

Gutierrez, Dianne B.↗

Gas Composition Sensing Using Carbon Nanotube Arrays

This innovation is a lightweight, small sensor for inert gases that consumes a relatively small amount of power and provides measurements that are as accurate as conventional approaches. The sensing approach is based on generating an electrical discharge and measuring the specific gas breakdown voltage associated with each gas present in a sample. An array of carbon nanotubes (CNTs) in a substrate is connected to a variable-pulse voltage source. The CNT tips are spaced appropriately from the second electrode maintained at a constant voltage. A sequence of voltage pulses is applied and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of the current-voltage characteristics. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas. The CNTs in the gas sensor have a sharp (low radius of curvature) tip; they are preferably multi-wall carbon nanotubes (MWCNTs) or carbon nanofibers (CNFs), to generate high-strength electrical fields adjacent to the tips for breakdown of the gas components with lower voltage application and generation of high current. The sensor system can provide a high-sensitivity, low-power-consumption tool that is very specific for identification of one or more gas components. The sensor can be multiplexed to measure current from multiple CNT arrays for simultaneous detection of several gas components.

Li, Jing↗

Modeling and validation of single-chamber microbial fuel cell cathode biofilm growth and response to oxidant gas composition

This work describes experiments and computational simulations to analyze single-chamber, air-cathode microbial fuel cell (MFC) performance and cathodic limitations in terms of current generation, power output, mass transport, biomass competition, and biofilm growth. Steady-state and transient cathode models were developed and experimentally validated. Two cathode gas mixtures were used to explore oxygen transport in the cathode: the MFCs exposed to a helium-oxygen mixture (heliox) produced higher current and power output than the group of MFCs exposed to air or a nitrogen-oxygen mixture (nitrox), indicating a dependence on gas-phase transport in the cathode. Multi-substance transport, biological reactions, and electrochemical reactions in a multi-layer and multi-biomass cathode biofilm were also simulated in a transient model. The transient model described biofilm growth over 15 days while providing insight into mass transport and cathodic dissolved species concentration profiles during biofilm growth. Lastly, simulation results predict that the dissolved oxygen content and diffusion in the cathode are key parameters affecting the power output of the air-cathode MFC system, with greater oxygen content in the cathode resulting in increased power output and fully-matured biomass.

59 BASIC BIOLOGICAL SCIENCES↗

Tropospheric gas composition and cloud structure of the Jovian North Equatorial Belt

Voyager IRIS observations of the NEB reveal longitudinal variability of 5-micron brightness temperatures of order 100 C. An anisotropic multiple scattering radiative transfer model is used to calculate synthetic spectra for comparison with the IRIS observations. Mie theory is used to model the spectral dependence of cloud extinction from 180 to 2300/cm. Cloud base locations within the model vary with assumed gas abundances according to thermochemical equilibrium. It is found that spatial variations in the abundance profiles of the condensible species, parahydrogen profiles and cloud optical depths can be used as tracers of the local and large-scale dynamics. The variation of cloud opacity is strongly correlated with the variation of relative humidity, which suggests that dynamic depletion of water vapor above the cloud forming level is the most plausible model to explain the spatial variation in the water profile within the NEB.

Carlson, Barbara E.↗

Novel Gas Composition Sensor for Monitoring Advanced Power Generation Systems

Power generation based on combustion will be an important part of American energy production for the foreseeable future. Optimization of the combustion process to maximize fuel efficiency and minimize harmful emissions will benefit from sensors capable of withstanding the harsh high pressure and high temperature environment typically found in the chamber. These devices must be versatile and easy to use with low probe cost in order to gain widespread acceptance and use. Physical Sciences Inc. and the research group of Prof. Scott Sanders at the University of Wisconsin have designed and demonstrated a novel sensor system for monitoring the concentration of multiple gas species in power generation systems. The system combines a novel laser from the optical telecommunications industry with a high-temperature measurement probe, sensitive detection electronics, and data processing algorithms. The Phase I program resulted in a successful demonstration of broadband spectroscopy combined with sensitive detection and chemometric algorithms to detect multiple gas species at high temperatures and pressures. A novel optical probe based on a sapphire fiber architecture that is compatible with the conditions expected in coal gasification systems was also designed. The initial target application for the proposed sensor is the monitoring of full scale, advanced power generation systems including coal gasifiers and gas turbines. The technology developed in this work may also be applied to many additional industrial processes, including continuous emission monitoring, pharmaceutical manufacturing and explosives detection. The ability to identify multiple species and measure their concentrations in a gas mixture will allow manufacturers to increase yields and reduce costs.

20 FOSSIL-FUELED POWER PLANTS↗

The role of gas composition in plasma-dust structures in RF discharge

The influence of a mixture of light and heavy gases, i.e., helium and argon, on plasma-dust structures in the radiofrequency discharge has been studied. The dust chains in the sheath of the radiofrequency discharge, the average distance between the dust particles and their chains, have been analyzed. A significant effect of small amounts of argon on the correlation characteristics of dust particles has been observed. The results of numerical simulation of ion and electron drift in the mixture of helium and argon are presented. It is shown that even 1% of argon admixture to helium produces such an effect that argon ions become the main components of the discharge, as they drift with lightweight helium forming a strongly anisotropic velocity distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of gas composition in weakened nonlinear standing wave excitation and improved plasma radial uniformity in very-high-frequency asymmetric capacitive Ar/CF 4 discharges

Abstract The higher harmonics generated by nonlinear sheath motion would enhance the standing wave effect, and thus lead to center-peaked plasma density profile in very-high-frequency (VHF) capacitive discharges. In this work, a nonlinear transmission line (NTL) model introduced in Zhouet al(2021Plasma Sources Sci. Technol.30125017) has been extended, with radial transport of various particles and nonlinear sheath motion into account, to investigate the effects of CF 4 fraction α on the nonlinear standing wave excitation and plasma radial uniformity in VHF (60 MHz) capacitively coupled Ar/CF 4 plasmas at 3 Pa. The results indicate that for pure Ar discharges (i.e. α = 0%), the nonlinearly excited harmonics with short wavelength significantly enhance the electron power absorption at the radial center, resulting in a pronounced central-high plasma density profile. As α increases, the high-order harmonics are gradually damped due to the increase of resistance, as well as the longer wavelength caused by thicker sheath thickness. Thus, the radial profile of the electron absorbed power density shifts from center-peak to edge-high. Besides, at the radial center, the electron density and Ar + ion density decrease with α , CF 3 + ion density shows an increasing trend, while F − ion density initially rises and then decreases. Moreover, the density profiles of all the species become more uniform at higher CF 4 fraction, due to the suppressed nonlinear standing wave excitation and the longer wavelength of the nonlinear harmonics.

Physics↗

Venus upper atmosphere neutral gas composition - First observations of the diurnal variations

Measurements of the composition, temperature, and diurnal variations of the major neutral constituents in the thermosphere of Venus are being made with a quadrupole mass spectrometer on the Pioneer Venus Orbiter. Concentrations of carbon dioxide, carbon monoxide, molecular nitrogen, atomic oxygen, and helium are presented, in addition to an empirical model of the data. The concentrations of the heavy gases, carbon dioxide, carbon monoxide, and molecular nitrogen, rapidly decrease from the evening terminator toward the nightside; the concentration of atomic oxygen remains nearly constant and the helium concentration increases, an indication of a nightside bulge. The kinetic temperature inferred from scale heights drops rapidly from 230 K at the terminator to 130 K at a solar zenith angle of 120 deg, and to 112 K at the antisolar point.

Niemann, H. B.↗

Implications of the gas compositional measurements of Pioneer Venus for the origin of planetary atmospheres

Comparisons are made between the volatile inventories of the terrestrial planets, including Pioneer Venus data, and the predictions of three classes of theories for the origin of planetary atmospheres. Serious difficulties arise for the primary atmosphere and external source hypotheses. The grain accretion hypothesis can account for the trends in the volatile inventory from Venus to earth to Mars, if volatiles were incorporated into planet-forming grains at nearly the same temperature for all of these planets, but at systematically lower pressures in the regions of planet formation farther from the center of the solar nebula.

Pollack, J. B.↗