Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of Methane Emissions Model to Assess Fuel Recovery Potential at Gas Well Sites Using On Site Compression

The U.S. natural gas production and consumption has increased 85.5% since 2005 primarily due to the unconventional production methods of horizontal drilling and hydraulic fracturing. Natural gas used as a fuel has a lower greenhouse gas (GHG) footprint than coal and petroleum due to lower Carbon Dioxide (CO2) emissions when combusted. However, the “greener” benefit to natural gas may be negated by leaks in production and transmission systems. Methane (CH4), the primary hydrocarbon in natural gas, has an estimated Global Warming Potential (GWP) of 28-36 over 100 years, meaning it can absorb 28-36 more energy than CO2 which has a GWP of 1.0. Natural gas well sites are prone to methane emissions, or leaks and irregular gas releases, vented to atmosphere throughout production and transmission. The U.S. Department of Energy (DOE) and the National Energy Technology Laboratory (NETL) has recently granted West Virginia University (WVU) funding under agreement DE-FOA-0002005, to “Advance technologies to mitigate methane emissions and increase the efficiency of the natural gas transportation infrastructure”. As part of this funding WVU was tasked with identifying and quantifying sources of methane emissions at unconventional well sites, processing this data, and developing a system to recapture these emissions. A 0-D Simulink model was developed, utilizing standardized methodologies, data from previously conducted studies, as well as collected data from well sites in the Marcellus shale play region. The model was developed to predict emission rates from various components at natural gas well sites as well as the potential to utilize these emissions as fuel for the natural gas powered compressor engines on-site. This model was utilized to run high, medium, and low cases for four identified emission sources, engine size, pneumatic controller count, liquid level production which dictates tank emissions, and compressor packing vent emissions. Due to discrepancies in transient tank emission data, a high and low emission factor for tanks was used, resulting in two sets of 81 executed cases, and 162 unique cases of total site emissions and potential for fuel consumption. Each of the cases were run over 86,400 seconds at a 1 Hz, representative of a full 24 hour day of operation. The fuel consumption offset an average of 557% of fuel consumption on an energy density basis across all 81 cases with the high tank emission factor with a maximum offset of 2334%. The fuel consumption offset was an average of 82.9% for all 81 cases with the low tank emission factor with a maximum offset of 337%. This study highlights flaws in the use of publicly available methane number calculations to determine natural gas’s suitability as an engine fuel as well as the lack of public data for transient liquid storage tank emissions.

03 NATURAL GAS↗

Equitable Electrification Analysis for Existing Buildings in Richmond, CA [Slides]

Since June 2022, NREL has provided technical assistance in the form of research and analysis in order to support the City of Richmond in identifying strategies to equitably transition its existing buildings from reliance on natural gas to clean electricity. Building on data from the ResStock and ComStock tools, the analysis looked at the potential impacts of building envelope and electrification improvements on energy consumption and greenhouse gas emissions, residential utility bills, jobs and employment, and indoor air quality. This presentation summarizes the findings from that research and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self Configuring Digital Twin for Optimizing E-Waste Recycling

Electronic waste recycling industry needs a decision support tool for optimizing their processes to become cost competitive. We developed a software called CMAT, Comprehensive Manufacturing Assessment Tool. The aim of CMAT is to provide the e-waste recycling companies with a fully customizable decision support framework that analyzes the optimal supply chain configurations. The software optimizes the logistics operations, helps to identify the best recycling process configuration, and generates valuable insights regarding the economic performance of different categories of e-waste. The ultimate purpose of the tool is to assist the users developing a digital twin of their processes and to provide insights on questions pertinent to the e-waste recycling industry including how to increase efficiency and reduce costs, energy consumption, and greenhouse gas emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential State Regulatory Pathways to Facilitate Low-Carbon Fuels

States and the federal government are increasingly engaged in the challenges around decarbonizing the electric grid. In particular, regulators, consumers, stakeholders, and utilities recognize the need to carefully consider the role natural gas will play in a decarbonized future. A variety of technology and policy options to reduce greenhouse gas emissions associated with natural gas use are available, including energy efficiency programs, demand reduction tools, strategic electrification, and strategies to reduce emissions from natural gas production, transportation, and consumption. Low-carbon fuels – mainly renewable natural gas (RNG) and clean hydrogen – are being considered an important component of decarbonization goals. RNG and hydrogen may be able to meaningfully reduce emissions from processes independent of geologic natural gas, displacing emissions of methane, a powerful greenhouse gas. Although RNG and hydrogen are not cost-competitive today with geologic natural gas and are smaller in scale and potential than other decarbonization options, they can be explored as potential critical tools to decarbonize sectors that are difficult to electrify or shift off of natural gas entirely, such as air travel, industrial processes, maritime transport, long-distance trucking, space heating on cold days, and railroads (Nadel, 2022). The role of this report is to provide informational context for state utility regulators to understand the impacts of and challenges associated with broader integration of low-carbon fuels, followed by examples of state regulatory actions taken to date to facilitate the development of low-carbon fuels. Setting clear guidance to calculate the environmental benefits of low-carbon fuels and continuing federal and state investments in research and development to reduce costs relative to fossil fuels will be important steps to take to signal the desire to grow the market for these fuels. State public utility commissions may play a key role in setting regulatory frameworks for low-carbon fuels and ensuring that ratepayer funds, if utilized, are done so to further the public interest. This report is intended to summarize decisions that states have made to date on low-carbon fuels. In the spirit of understanding the current market and sharing information, this report provides success stories, and lessons learned across states as regulators implement varying strategies to achieve decarbonization objectives while maintaining their focus on affordability, safety, and reliability of the energy system. The report begins with an introduction of the role of natural gas in the U.S. economy (Section I) and background information on natural gas use, decarbonization, and low-carbon fuels (Section II). Next, the report describes the current market by discussing the scale of current production, emissions intensity, resource potential, and costs of low-carbon fuels compared to geologic natural gas (Section III). Following these sections, the report describes four strategies states have employed to facilitate low-carbon fuels: opening exploratory dockets, approving voluntary tariffs for customers, approving interconnection tariffs for producers, and considering portfolio-wide procurement targets (Section IV). This section lists states that have taken actions in each category, citing utility filings, commission decisions, stakeholder comments, and other relevant sources. Finally, the report concludes with suggested questions regulators may wish to consider regarding low-carbon fuels, in the interest of preparing to make decisions in the future (Section V). These questions include: Are there existing regulatory or technical barriers to voluntary purchases of low-carbon fuels? Can customers work with utilities to procure low-carbon fuels; are producers able to interconnect projects without significant barriers to entry? Should the infrastructure and/or commodity costs of low-carbon fuels be socialized among all ratepayers, or borne solely by the large commercial and industrial (C&I) customers currently driving the market? Should regulated natural gas and/or electric utilities own and operate low-carbon fuel production? How should regulators consider the unique decarbonization potential of low-carbon fuels, particularly for hard-to-abate sectors, in decision-making? Is additional direction or clarity from state policymakers needed? What no-regrets approaches can help facilitate both near-term RNG development and long-term development of hydrogen and other zero-carbon fuels? We collectively wish to express our gratitude to the U.S. Department of Energy, Office of Fossil Energy and Carbon Management, for supporting this report and other technical assistance resources for state regulators on natural gas topics. State regulators operate under a variety of policy environments, and states have vastly different types of energy resources, infrastructure, and customers. While there is no optimal regulatory, policy, or technological solution that will be successful in every state, state regulators can benefit by exchanging lessons learned with their peers across the country. We look forward to continued engagement with our fellow commissioners, commission staff, NARUC, the U.S. Department of Energy, and other stakeholders to develop sound regulation in the public interest.

03 NATURAL GAS↗

2020 natural gas LCA appendices Rev1

This collection is the data-centric appendices for the report Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile. It consists of Appendix A: Additional Modeling Parameters [spreadsheet]; Appendix B: Water Burdens [spreadsheet]; Appendix D: Simulation of Liquids Unloading [python script and spreadsheet]; Appendix E: Detailed GHG Results for All Scenarios [spreadsheet]; Appendix F: Full Inventory Results [spreadsheet]; and Appendix I: Stage-Level Natural Gas Loss and Consumption Rates [spreadsheet]. These results have been updated from the previous version (https://edx.netl.doe.gov/dataset/2020-natural-gas-lca-data-appendices) to correct a modeling error where the same post-processing natural gas composition was used instead of the intended regional compositions.

Appendices↗

BioC2G Tool v1

The BioC2G tool provides an interface for running technoeconomic analyses and life-cycle assessments of biofuel and bioproduct production pathways. Models for the pathways are currently built into the tool: limonene, limonane, bisabolene, bisabolane, ethanol, isoprenol, DMCO, and HEFA. Additionally, a "Custom" option is available for analyzing a bioproduction pathway not included among the built-in examples. Users must supply key product properties and process parameters. Three types of model runs are available in the tool: minimum selling price (MSP), water consumption, and greenhouse gas (GHG) emissions. Running the MSP model yields a breakdown of MSP by major process stage of production, along with a a table of estimated capital expenditures (CAPEX) and annual operating expenditures (OPEX). Running the water consumption and GHG models yields a breakdown of water consumed and carbon emissions respectively, per unit of end product. A breakdown of these metrics by major process stage is also provided. Model run results can be viewed in the web interface numerically and graphically, as well as downloaded in CSV format. Detailed documentation on model methodology and assumptions is also available for download.

Huntington, Tyler↗

BuildingsBench: A Benchmark for Universal Building Load Forecasting [SWR-23-51]

The residential and commercial building stock in the United States is responsible for a significant percentage of energy consumption and greenhouse gas emissions. Electrification of end-uses, as well as decarbonizing the electrical grid through renewable energy sources such as solar and wind, constitutes the pathway to zero-emission buildings. Forecasting day-ahead building energy consumption is an integral part of this solution. Currently, specialized forecasting models are hand-made for each individual building, which is time-consuming, expensive, and leads to duplicated efforts. BuildingsBench is a Python software framework for training and comparing generalized machine learning models for universal building load forecasting. This challenge tasks a single foundational model to generalize its forecasts for a wide variety of buildings, across geographic regions, building types, weather patterns, and more. This software provide code for pre-training such models and subsequently evaluating their performance on a suite of hundreds of diverse real and synthetic buildings. BuildingsBench is a platform for: - Large-scale pretraining with the synthetic Buildings-900K dataset for short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock and is extracted from the NREL End-Use Load Profiles database. - Benchmarking on two tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. We provide an index-based PyTorch Dataset for large-scale pretraining, easy data loading for multiple real building energy consumption datasets as PyTorch Tensors or Pandas DataFrames, simple (persistence) to advanced (transformer) baselines, metrics management, and more.

Emami, Patrick↗

Coupling Waste Feedstocks to Microbial Protein Production in a Circular Food System

Global food production is a major contributor to greenhouse gas emissions, water consumption, and land use. As an alternative to conventional agriculture, the production of waste-derived microbial protein (MP) holds promise for reducing environmental impacts. MP can be mass-produced in volumetrically scalable fermentation processes on short time scales, enabling facile scale-up with lower greenhouse gas emissions, land use, and water impacts than animal and, in some cases, plant protein. MP can also be produced from waste feedstocks, diverting waste from landfills or the natural environment. This Perspective explores the availability and suitability of waste feedstocks for MP production, suggesting that MP generated from waste feedstocks in the United States could fulfill twice the current national protein demand. Here, we also discuss the biotechnological and separations processes required to produce food-grade MP for human consumption from waste. Key challenges include MP consistency, consumer and regulatory acceptance, and the process utilities (electricity, heat, and nutrients) that account for up to 85% of MP costs and most environmental impacts, all of which present opportunities for innovation in the microbiology and process design spaces. Overall, this work highlights the potential of MP to contribute to a more circular, resilient, and sustainable food system.

09 BIOMASS FUELS↗

Supply Chain Energy and Greenhouse Gas Analysis Using the Materials Flows through Industry (MFI) Tool: Examination of Decarbonization Technology Scenarios for the U.S. Glass Manufacturing Sector

Glass manufacturing is a major part of the U.S. economy, and glass products in multiple sectors - flat glass, container glass, and fiberglass - are a part of everyday life. Despite glass manufacturing's long history, there are still many opportunities for glass production to improve in terms of both in overall energy consumption and greenhouse gas (GHG) emission reduction. Scenarios for the flat, container, and fiberglass sectors show the effect that each improvement has on primary energy demand and GHG emissions, starting from an industry baseline that reflects current manufacturing practices. Using the National Renewable Energy Laboratory's Material Flows through Industry tool, multiple scenarios are examined for each glass sector by applying a combination of energy reduction, increased electrification, hydrogen cofiring, a more renewable electric grid, and increased use of cullet. Additional decarbonization options are possible for glass but are left for later analysis due to cost, feasibility, or data issues. Primary energy demand can be reduced by 75%-83% compared to baseline inputs, depending on the sector, and GHG emissions are reduced by 82%-86%. Applying the maximum level of improvements listed here has the potential to save over 300 million GJ and 25 million metric tons of GHGs by 2050.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2020 natural gas LCA data appendices

This collection is the data-centric appendices for the report Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile. It consists of Appendix A: Additional Modeling Parameters [spreadsheet]; Appendix B: Water Burdens [spreadsheet]; Appendix D: Simulation of Liquids Unloading [python script and spreadsheet]; Appendix E: Detailed GHG Results for All Scenarios [spreadsheet]; Appendix F: Full Inventory Results [spreadsheet]; and Appendix I: Stage-Level Natural Gas Loss and Consumption Rates [spreadsheet].

Appendices↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Design Requirements and Software Specification for the Autonomous Energy Management Software System for Small Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems. Many of these buildings are small (<50,000 square feet), underserved, and use rooftop units for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the rooftop units heating and cooling set points, schedules, setbacks, and optimal start can result in 20 to 25 percent reduction in electricity consumption in small commercial buildings. In addition, improving demand flexibility of these buildings will result additional cost savings for the building owner. Therefore, the Department of Energy’s Building Technologies Office approved a project to address the needs for small commercial buildings. The project is led by Pacific Northwest National Laboratory (PNNL) with Intellimation LLC as the cooperative research and development agreement partner. The primary goal of the project is to develop and validate an autonomous energy management software (AEMS) system that will continuously optimize small commercial building operations by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. The work will leverage the vast experience of PNNL research and development staff who have over two decades of experience in developing and successfully transferring software technologies to the private sector. This solution will be jointly developed with Intellimation, a company that plans to use it to scale their building energy efficiency (EE) and grid services offering. Widespread deployment of the AEMS system will improve the EE and demand flexibility of the building commercial building stock. It should also support cities and states in meeting their climate change mitigation goals. This document describes the various EE and grid service features of the AEMS system, infrastructure and data required to implement those features, and how the features should be automated. It also details how the various features will be tested and validated, including field validation. The document also details what flexibility the users have and how they will be able to leverage those capabilities exercise those. The intent is to create an AEMS system that would support scalable deployment, requires minimal configuration, and is easy to maintain over its expected lifespan. The initial alpha release of AEMS system is planned for March 2023, and the beta release is planned for the summer of 2023. The final release is planned for March 2024. Section 2 of the report documents the relevant building types that AEMS is suitable for. Section 3 documents EE features that will be supported. It will also include the data requirements, hardware requirements, implementation details, and how EE features will be tested and validated. Grid service features will be documented in section 4, including data requirements, hardware requirements, implementation details, and how the services will be tested and validated. Planned next steps are described in section 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Star formation and molecular gas properties of post-starburst galaxies

Post-starburst galaxies are believed to be in a rapid transition between major merger starbursts and quiescent ellipticals. Their optical spectrum is dominated by A-type stars, suggesting a starburst that was quenched recently. While optical observations suggest little ongoing star formation, some have been shown to host significant molecular gas reservoirs. This led to the suggestion that gas depletion is not required to end the starburst, and that star formation is suppressed by other processes. We present NOEMA CO(1−0) observations of 15 post-starburst galaxies with emission lines consistent with active galactic nucleus (AGN) photoionization. We collect post-starburst candidates with molecular gas measurements from the literature, with some classified as classical E + A, while others with line ratios consistent with AGN and/or shock ionization. Using far-infrared observations, we show that systems that were reported to host exceptionally large molecular gas reservoirs host in fact obscured star formation, with some systems showing star formation rates comparable to ULIRGs. Among E + A galaxies with molecular gas measurements, 7 out of 26 (26 per cent) host obscured starbursts. Using far-infrared observations, post-starburst candidates show similar SFR– M H 2 and Kennicutt–Schmidt relations to those observed in star-forming and starburst galaxies. In particular, there is no need to hypothesize star formation quenching by processes other than the consumption of molecular gas by star formation. The combination of optical, far-infrared, and CO observations indicates that some regions within these galaxies have been recently quenched, while others are still forming stars in highly obscured regions. All this calls into question the traditional interpretation of such galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Disturbed, diffuse, or just missing? A global study of the H I content of Hickson compact groups

Hickson compact groups (HCGs) are dense configurations of four to ten galaxies, whose H I morphology appears to follow an evolutionary sequence of three phases, with gas initially confined to galaxies, then significant amounts spread throughout the intra-group medium, and finally with almost no gas remaining in the galaxies themselves. It has also been suggested that several groups may harbour a diffuse H I component that is resolved out by interferometric observations. The H I deficiency of HCGs is expected to increase as the H I morphological phase progresses along the evolutionary sequence. If this is the case, H I deficiency would be a rough proxy for the age and evolutionary state of a HCG. We aim to test this hypothesis for the first time using a large sample of HCGs and to investigate the evidence for diffuse H I in HCGs. We performed a uniform reduction of all publicly available VLA H I observations (38 HCGs) with a purpose-built pipeline that also maximises the reproducibility of this study. The resulting H I data cubes were then analysed with the latest software tools to perform a manual separation of emission features into those belonging to galaxies and those extending into the intra-group medium. We thereby classified the H I morphological phase of each group as well as quantified their H I deficiency compared to galaxies in isolation. We find little evidence that H I deficiency can be used as a proxy for the evolutionary phase of a compact group in either of the first two phases, with the distribution of H I deficiency being consistent in both. However, for the final phase, the distribution clearly shifts to high H I deficiencies, with more than 90% of the expected H I content typically missing. Across all HCGs studied, we identify a few cases where there is strong evidence for a diffuse gas component in the intra-group medium, which might be detectable with improved observations. We also classify a new sub-phase where groups contain a lone H I -bearing galaxy, but are otherwise devoid of gas. The new morphological phase we have identified is likely the result of an evolved, gas-poor group acquiring a new, gas-rich member. The large spread of H I deficiencies in the first two morphological phases suggests that there is a broad range of initial H I content in HCGs, which is perhaps influenced by large-scale environment, and that the timescale for morphological changes is, in general, considerably shorter than the timescale for the destruction or consumption of neutral gas in these systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗