Thermionic converters and generators for space application. II - Solar thermionic generators.
Solar-heated thermionic generator design and fabrication evaluation, considering mirror configurations
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Solar-heated thermionic generator design and fabrication evaluation, considering mirror configurations
Comparison performance data of compressor blading without slots or vortex generators
Primary results are summarized for a three-part study involving the effects of connecting a MOD-OA wind turbine generator to an isolated diesel power system. The MOD-OA installation considered was the third of four experimental nominal 200 kW wind turbines connected to various utilities under the Federal Wind Energy Program and was characterized by the highest wind energy penetration levels of four sites. The study analyses address: fuel displacement, dynamic interaction, and three modes of reactive power control. These analyses all have as their basis the results of the data acquisition program conducted on Block Island, Rhode Island.
Assessing the performance of a MOD-OA horizontal axis wind turbine connected to an isolated diesel utility, a comprehensive data measurement program was conducted on the Block Island Power Company installation on Block Island, Rhode Island. The detailed results of that program focusing on three principal areas of (1) fuel displacement (savings), (2) dynamic interaction between the diesel utility and the wind turbine, (3) effects of three models of wind turbine reactive power control are presented. The approximate two month duration of the data acquisition program conducted in the winter months (February into April 1982) revealed performance during periods of highest wind energy penetration and hence severity of operation. Even under such conditions fuel savings were significant resulting in a fuel reduction of 6.7% while the MOD-OA was generating 10.7% of the total electrical energy. Also, electrical disturbance and interactive effects were of an acceptable level.
A topology of crowned spur pinion tooth surface that reduces the level of transmission errors due to misalignment is proposed. The geometry of the deviated pinion tooth surface and regular gear tooth surface, along with tooth contact analysis is discussed. Generation of the deviated pinion tooth surface by a plane whose motion is controlled by a five-degree-of-freedom system is proposed. Numerical results are included and indicate that transmission errors remain low as the gears are misaligned.
A method for generation of crowned pinion tooth surfaces using a surface of revolution is developed. The crowned pinion meshes with a regular involute gear and has a prescribed parabolic type of transmission errors when the gears operate in the aligned mode. When the gears are misaligned the transmission error remains parabolic with the maximum level still remaining very small (less than 0.34 arc second for the numerical examples). Tooth Contact Analysis (TCA) is used to simulate the conditions of meshing, determine the transmission error, and the bearing contact.
There are numerous studies which show that CASE Tools greatly facilitate software development. As a result of these advantages, an increasing amount of software development is done with CASE Tools. As more software engineers become proficient with these tools, their experience and feedback lead to further development with the tools themselves. What has not been widely studied, however, is the reliability and efficiency of the actual code produced by the CASE Tools. This investigation considered these matters. Three segments of code generated by MATRIXx, one of many commercially available CASE Tools, were chosen for analysis: ETOFLIGHT, a portion of the Earth to Orbit Flight software, and ECLSS and PFMC, modules for Environmental Control and Life Support System and Pump Fan Motor Control, respectively.
The electrical system options for variable speed operation of a wind turbine generator are treated in this paper. The key operating characteristics of each system are discussed and the major advantages and disadvantages of each are identified
The SPE Oxygen Generator Assembly (OGA) has been modified to correct operational deficiencies present in the original system, and to effect changes to the system hardware and software such that its operating conditions are consistent with the latest configuration requirements for the International Space Station Alpha (ISSA). The effectiveness of these changes has recently been verified through a comprehensive test program which saw the SPE OGA operate for over 740 hours at various test conditions, including over 690 hours, or approximately 460 cycles, simulating the orbit of the space station. This report documents the changes made to the SPE OGA, presents and discusses the test results from the acceptance test program, and provides recommendations for additional development activities pertinent to evolution of the SPE OGA to a flight configuration. Copies of the test data from the acceptance test program are provided with this report on 3.5 inch diskettes in self-extracting archive files.
A new software tool, AeroDB, is used to compute thousands of Euler and Navier-Stokes solutions for a 2nd generation glide-back booster in one week. The solution process exploits a common job-submission grid environment using 13 computers located at 4 different geographical sites. Process automation and web-based access to the database greatly reduces the user workload, removing much of the tedium and tendency for user input errors. The database consists of forces, moments, and solution files obtained by varying the Mach number, angle of attack, and sideslip angle. The forces and moments compare well with experimental data. Stability derivatives are also computed using a monotone cubic spline procedure. Flow visualization and three-dimensional surface plots are used to interpret and characterize the nature of computed flow fields.
The GeoNEX (Geostationary-NASA Earth eXchange) Level-1G products consist of top-of-atmosphere (TOA) bi-directional reflectance factor (BRF) and brightness temperature generated with data streams from the latest geostationary (GEO) sensors including GOES-16/17 ABI, Himawari-8/9 AHI, and GK-2A AMI on a global tiled common grid (60oN-60o and 180oW-180oE) in geographic coordinates. With their 16 spectral bands, 0.01o/0.02o nadir spatial resolution, and 10-minute temporal resolutions, these products provide exciting opportunity to monitor Earth surface processes. However, the unique Sun-Target-Satellite geometry of geostationary sensors demands special attention in analyzing/interpreting these datasets. In this study we present a systematic analysis on the relationship between the radiometric uncertainties of the GeoNEX TOA reflectance and the corresponding solar/satellite zenith angles. We show that the signal-to-noise ratio (SNR) of the BRF are positively proportional to the square roots of the cosine of solar illuminating zenith angles. That is, the BRF data are noisier earlier in the morning or later in the afternoon than in the mid of the day. The cosine of satellite viewing zenith angles do not directly influence the SNR of the TOA BRF. However, they positively regulate the relative importance of the surface component in the TOA BRF. This means that variations in surface reflectance are more difficult to detect for pixels with larger view zenith angles, even when the SNR of the TOA BRF is the same. We are developing metrics to specify such illumination-view geometry related uncertainties in the GeoNEX L1G TOA BRF products so that this key information can be easily accessed by the user community.
Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.
Explore the source record for details and available documents.
Buildings make up a large portion of energy consumption in the U.S. today. Understanding their energy consumption patterns can improve their efficiency, but requires detailed models that rely on incomplete or unknown information. Previous work has shown that artificial intelligence (AI) can be used to predict missing information and even suggest upgrades to improve building efficiency. However, building upgrades may require undesirable upfront costs. Oppositely, advanced control could improve building efficiency with negligible upfront cost. To explore the tradeoffs between these two approaches, in this work we propose a workflow to compute optimal temperature setpoint schedules to minimize energy consumption and operational cost. Results show that modifying the temperature setpoints in a building using model predictive control (MPC) can effectively reduce its energy consumption and operational cost. This optimal operation cannot fully meet a desired goal. However, we show that by considering MPC in addition to component upgrades, a desired goal can be met with significantly less upfront costs.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.