Search NASA⌕ Search

SEARCH · Search NASA

Results for “geothermal operations optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental study on rheological and settling properties of shape memory polymer for fracture sealing in geothermal formations

This article studies the rheology and annular flow of a smart lost circulation material (LCM) at 160 °C, using a high-temperature flow loop. The smart LCM is a shape memory polymer (SMP) that activates at high temperatures, and its particle size increases to seal fractures in geothermal formations. SMP was mixed with the base fluid in two different concentrations, 1.0 and 3.0 wt%, to study rheology, wellbore hydraulics, activation process, and settling behavior under different testing conditions. The results of this study showed that the SMP could be activated at high temperatures. An increase of 80–100% in the particle size was observed at 160 °C. The mud samples showed a high shear-thinning behavior at the two concentrations with a Power-law flow index (n) ranging between 0.025 and 0.101. No additional frictional pressure losses were observed when SMP was added to the base fluid. SMP particles showed an excellent suspension at 1.0 wt% while, at 3.0 wt%, a bed was formed at a low flow rate and without pipe rotation. Increasing the drill pipe rotational speed or flow rate effectively removed the bed and homogeneously dispersed the SMP particles, ensuring a better sealing efficiency. SMP particle dispersion in inclined wells was better than in horizontal wells. Moreover, the findings of this study help optimize the lost circulation treatment by considering a wide range of operating parameters that can further be extended to different systems and geometries.

02 PETROLEUM↗

Retrofitting a Geothermal Plant with Solar and Storage to Increase Power Generation

Solar hybridization using concentrating solar power (CSP) can be an effective approach to augment the power generation and power cycle efficiency of a geothermal power plant with a declining resource. Thermal storage can further increase the dispatchability of a geothermal/solar hybrid system, which is particularly valued for a national grid with high renewable penetration. In this paper, a hybrid plant design with thermal storage is proposed based on the requirements of the Coso geothermal field in China Lake, California. The objective is to increase the power production by 4 MWe. In this system, a portion of the injection brine is recirculated through a heat exchanger with the solar heat transfer fluid, before being mixed with the production well brine. In the solar heating loop the brine should be heated to at least 155 degrees C to increase the net power. The solar field and storage were sized based on solar data for China Lake. Thermal storage is used to store excess power at the high-solar-irradiation hours and generate additional power during the evenings. The solar field size, the type and capacity of thermal storage and the operating temperatures are critical factors in determining the most economic hybrid system. Further investigations are required to optimize the hybrid system and evaluate its economic feasibility.

15 GEOTHERMAL ENERGY↗

Optimizing district energy systems by integrating Borehole Thermal Energy Storage Using a Mixed-Integer Linear Programming g-function framework with a Multi-Timescale Rolling Horizon method

Shallow geothermal has gained increasing attention in recent years; however, a reliable framework for its accurate incorporation into large-scale energy system optimization remains lacking. This study proposes a Mixed-Integer Linear Programming (MILP) framework combined with the g-function approach to integrate Borehole Thermal Energy Storage (BTES) technology into energy system optimization. Validation against a Modelica-based reservoir network simulation demonstrates that the proposed framework effectively captures the ground thermal response under varying energy loads and accurately estimates the borefield energy supply. To enhance scalability, a Rolling Horizon with Multi-Timescale (RH-MTS) method is further introduced, reducing computational time by 73 % for the 1-year optimization model with only minor loss of optimality. The framework is demonstrated through the case study of the UC Berkeley campus. Results indicate that BTES is a cost-effective and low-carbon solution: two borefields comprising 382 boreholes can meet 8.0 % and 6.6 % of the total campus heating and cooling demand, respectively, at an average energy rate of 0.70–0.77 USD/kWh and carbon intensity of 0.54 kg-CO2/kWh. Short-term analysis reveals a 35%–65% decline in BTES energy flow after 3–6 months of continuous heating/cooling operation, while long-term simulation shows that annual energy production of BTES can vary by up to 12.0 % after four years before stabilizing. Overall, this study develops a novel optimization framework that couples physics-based g-function method with MILP optimization framework, thereby advancing methodological development for shallow-geothermal integration and providing actionable guidance for BTES deployment in district-energy systems.

Yang, Jiahui↗

Reactive transport modeling of the Aquifer Thermal Energy Storage (ATES) system at Stockton University, New Jersey during seasonal operations

Hydrogeochemical processes associated with Aquifer Thermal Energy Storage (ATES) operations can often impact the system performance owing to mineral precipitation either at the wellbore or in the aquifer owing to changes in temperature and fluid disequilibria. Although failure of ATES systems due to mineral precipitation ("fouling") is common, predictive reactive-transport models have rarely been applied to plan their design and operation. Here, the objective of this study is to develop a reactive-transport model by coupling thermal, hydrological, and chemical (THC) processes to evaluate effects of introduced atmospheric oxygen on water chemistry, mineral precipitation/dissolution, porosity, and permeability changes associated with an ATES system at Stockton University (New Jersey, USA). The THC model builds on a Thermal-Hydrological-Mechanical (THM) model of the site that evaluated system failure owing to possible fracturing in the caprock or around the wellbore. The causes of the system failure are not known – potential causes include hydraulic fracturing owing to elevated pump pressures that took place, a flow pathway created by one of the boreholes, or a pre-existing natural hydrologic connection between the upper unconfined aquifer and the ATES aquifer, any of which could have led to oxygenated water entering the reservoir and causing the observed Fe-oxide fouling on well screens. The THC model is used to evaluate some of the hypotheses and observations regarding system failure owing to geochemical processes. The reactive-transport code TOUGHREACT V4 was used to model the THC processes during seasonal heating and cooling operations at the Stockton ATES site over 6 years of operation. In the THC simulations, the primary effects on geochemistry were observed when the injection water is saturated with atmospheric oxygen. Simulations show greater precipitation of goethite near the cold wells as compared to the warm wells. Although volume fractions of Fe-hydroxides were relatively small, the model was aimed at processes in the aquifer at the scale of meters and larger rather than at the scale of mm or cm (i.e., a well screen). Kaolinite is the dominant precipitating phase, also around the cold wells. Illite dissolves near the cold wells and precipitates near the warm wells. There is a net decrease in the porosity near the cold wells and increase near the warm wells, although a slight amount of thermal contraction near the cold wells and expansion near the warm wells is responsible for a significant proportion of the porosity change. Owing to the coarse discretization of the numerical grid near the wells (compared to the screen thickness) the magnitude of permeability changes at the wellbore are likely underestimated. The reactive transport model in this study can be used for characterization of aquifers, optimizing the operational parameters (temperature, pressure, pH etc.), and planning of mitigation strategies for ATES systems.

15 GEOTHERMAL ENERGY↗

Machine Learning-Assisted High-Temperature Reservoir Thermal Energy Storage Optimization: Numerical Modeling and Machine Learning Input and Output Files

This data set includes the numerical modeling input files and output files used to synthesize data, and the reduced-order machine learning models trained from the synthesized data for reservoir thermal energy storage site identification. In this study, a machine-learning-assisted computational framework is presented to identify High-Temperature Reservoir Thermal Energy Storage (HT-RTES) site with optimal performance metrics by combining physics-based simulation with stochastic hydrogeologic formation and thermal energy storage operation parameters, artificial neural network regression of the simulation data, and genetic algorithm-enabled multi-objective optimization. A doublet well configuration with a layered (aquitard-aquifer-aquitard) generic reservoir is simulated for cases of continuous operation and seasonal-cycle operation scenarios. Neural network-based surrogate models are developed for the two scenarios and applied to generate the Pareto fronts of the HT-RTES performance for four potential HT-RTES sites. The developed Pareto optimal solutions indicate the performance of HT-RTES is operation-scenario (i.e., fluid cycle) and reservoir-site dependent, and the performance metrics have competing effects for a given site and a given fluid cycle. The developed neural network models can be applied to identify suitable sites for HT-RTES, and the proposed framework sheds light on the design of resilient HT-RTES systems. All the simulations and the neural network model were done by Idaho National Laboratory. A detailed description of the work was reported in publication linked below.

15 GEOTHERMAL ENERGY↗

Observations on the Optimality Tolerance in the CAISO 33% RPS Model

In 2008 Governor Schwarzenegger of California issued an executive order requiring that 33 percent of all electricity in the state in the year 2020 should come from renewable resources such as wind, solar, geothermal, biomass, and small hydroelectric facilities. This 33% renewable portfolio standard (RPS) was further codified and signed into law by Governor Brown in 2011. To assess the market impacts of such a requirement, the California Public Utilities Commission (CPUC) initiated a study to quantify the cost, risk, and timing of achieving a 33% RPS by 2020. The California Independent System Operator (CAISO) was contracted to manage this study. The production simulation model used in this study was developed using the PLEXOS software package, which allows energy planners to optimize long-term system planning decisions under a wide variety of system constraints. In this note we describe our observations on varying the optimality tolerance in the CAISO 33% RPS model. In particular, we observe that changing the optimality tolerance from .05% to .5% leads to solutions over 5 times faster, on average, producing very similar solutions with a negligible difference in overall distance from optimality.

09 BIOMASS FUELS↗

SOI-Based High-Voltage, High-Temperature Integrated Circuit Gate Driver for SiC-Based Power FETs

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimizing system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8-m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

33 ADVANCED PROPULSION SYSTEMS↗

Silicon-on-insulator-based high-voltage, high-temperature integrated circuit gate driver for silicon carbide-based power field effect transistors

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimising system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8--m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

99 GENERAL AND MISCELLANEOUS↗

Inversion of geothermal heat flux in a thermomechanically coupled nonlinear Stokes ice sheet model

We address the inverse problem of inferring the basal geothermal heat flux from surface velocity observations using a steady-state thermomechanically coupled nonlinear Stokes ice flow model. This is a challenging inverse problem since the map from basal heat flux to surface velocity observables is indirect: the heat flux is a boundary condition for the thermal advection–diffusion equation, which couples to the nonlinear Stokes ice flow equations; together they determine the surface ice flow velocity. This multiphysics inverse problem is formulated as a nonlinear least-squares optimization problem with a cost functional that includes the data misfit between surface velocity observations and model predictions. A Tikhonov regularization term is added to render the problem well posed. We derive adjoint-based gradient and Hessian expressions for the resulting partial differential equation (PDE)-constrained optimization problem and propose an inexact Newton method for its solution. As a consequence of the Petrov–Galerkin discretization of the energy equation, we show that discretization and differentiation do not commute; that is, the order in which we discretize the cost functional and differentiate it affects the correctness of the gradient. Using two- and three-dimensional model problems, we study the prospects for and limitations of the inference of the geothermal heat flux field from surface velocity observations. The results show that the reconstruction improves as the noise level in the observations decreases and that short-wavelength variations in the geothermal heat flux are difficult to recover. We analyze the ill-posedness of the inverse problem as a function of the number of observations by examining the spectrum of the Hessian of the cost functional. Motivated by the popularity of operator-split or staggered solvers for forward multiphysics problems – i.e., those that drop two-way coupling terms to yield a one-way coupled forward Jacobian – we study the effect on the inversion of a one-way coupling of the adjoint energy and Stokes equations. Here, we show that taking such a one-way coupled approach for the adjoint equations can lead to an incorrect gradient and premature termination of optimization iterations. This is due to loss of a descent direction stemming from inconsistency of the gradient with the contours of the cost functional. Nevertheless, one may still obtain a reasonable approximate inverse solution particularly if important features of the reconstructed solution emerge early in optimization iterations, before the premature termination.

15 GEOTHERMAL ENERGY↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

2015 Geothermal Technologies Office Peer Review Summary: Energetic Materials for EGS Well Stimulation

The development of enhanced or engineered geothermal systems (EGS), by definition, includes an engineered approach to reservoir stimulation. EGS require an effective method of generating a high surface area network of fractures, or the stimulation of existing fractures, in a formation in order to increase permeability/heat-transfer. The most accepted methodologies include hydraulic fracturing and chemical stimulation. Alternative methods employing energetic materials have been employed for reservoir stimulation. For oil & gas reservoirs, this has been accomplished in the past with solid propellant gas generators and high explosives but the pressurization rate and final pressure cannot be controlled or easily adjusted in the field. Our program is investigating controlled and tailored rapid gas generation from solid, liquid and gaseous energetic formulations to operate in the chasm between conventional propellants and solid high explosives. This distinct solid, liquid and gas phase energetic materials approach has specific attributes and that could be used synergistically or individually to enhance a specific formation. This may prove to enhance the viability of using geothermal resources for power production. By employing optimized energetic materials we can tailor burn rates above propellant burn rates to optimize the gas generation rate without entering the excessive realm of the high pressures generated by high explosives. Gas phase energetic materials offer a unique method of tailoring reaction rate and final pressure. Again, rapid pressurization at rates, far exceeding quasi-static conventional hydraulic rates, can generate multiple radial wellbore fractures and potentially provide a mechanism to induce shear destabilization within the formation that enables the fractures to be self-propping. Multiple fractures from the wellbore allow efficient coupling to the existing formation fracture network. Furthermore, these techniques allow for repeated stimulations allowing fractures to be extended further. Controlled rate pressurization is a useful tool for the efficient implementation of EGS. This multi-phase approach to fracturing can eliminate the need for massive pumping equipment and the water required with conventional hydraulic fracturing methods. Additionally these methods use “green” materials with negligible environmental impact. These methods promise to be more economical than conventional stimulation techniques. Our objective is to develop a family of ideal candidate energetic systems for optimally stimulating a formation.

15 GEOTHERMAL ENERGY↗

Additive Manufacturing Case Study

Geothermal technologies include an extremely wide range of products required for well construction, completion, production, intervention and surface energy conversion activities. Many of these products are geometrically complex, require multi-step and highly specialized fabrication processes, and are expensive due to the low production numbers typically associated with the geothermal market. These challenges along with the high temperature demands of the geothermal environment have also hindered the adoption of many tools routinely used in the oil & gas industry.Recent advancements in Additive Manufacturing (AM) materials of construction, build volumes and part quality have transitioned the technology from primarily cosmetic prototyping applications to the point where AM can be used to make production parts, even for the most demanding applications. These improved AM capabilities along with the inherent ability of AM to produce complex parts and, in some cases, geometries that cannot be manufactured using conventional casting, machining and joining fabrication approaches motivate an exploration of its potential to positively impact geothermal well construction and operations technologies.Sandia National Labs collaborated with Oak Ridge National Laboratory on a case study examining additive manufacturing opportunities for Geothermal applications. The study focused on designing components with improved performance characteristics that cannot be fabricated conventionally. A rotor for a downhole motor was chosen based on the potential for improving its rotational dynamics. Topology optimization was used as a design method to reduce the rotational inertia of the part while preserving sufficient rotational stiffness to transmit the torque required for the drilling application. The optimization resulted in a nearly 50% reduction in polar moment of inertia while maintaining other desired performance characteristics. The design developed using the topology optimization approach was fabricated using additive manufacturing and cannot be fabricated conventionally. This paper will discuss the design approach, performance improvements and manufacturing methods used to produce the part.

Polsky, Yarom↗

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗

Three-dimensional induced polarization data inversion for complex resistivity

The conductive and capacitive material properties of the subsurface can be quantified through the frequency-dependent complex resistivity. However, the routine three-dimensional (3D) interpretation of voluminous induced polarization (IP) data sets still poses a challenge due to large computational demands and solution nonuniqueness. We have developed a flexible methodology for 3D (spectral) IP data inversion. Our inversion algorithm is adapted from a frequency-domain electromagnetic (EM) inversion method primarily developed for large-scale hydrocarbon and geothermal energy exploration purposes. The method has proven to be efficient by implementing the nonlinear conjugate gradient method with hierarchical parallelism and by using an optimal finite-difference forward modeling mesh design scheme. The method allows for a large range of survey scales, providing a tool for both exploration and environmental applications. We experimented with an image focusing technique to improve the poor depth resolution of surface data sets with small survey spreads. The algorithm's underlying forward modeling operator properly accounts for EM coupling effects; thus, traditionally used EM coupling correction procedures are not needed. The methodology was applied to both synthetic and field data. We tested the benefit of directly inverting EM coupling contaminated data using a synthetic large-scale exploration data set. Afterward, we further tested the monitoring capability of our method by inverting time-lapse data from an environmental remediation experiment near Rifle, Colorado. Similar trends observed in both our solution and another 2D inversion were in accordance with previous findings about the IP effects due to subsurface microbial activity.

15 GEOTHERMAL ENERGY↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Geothermal Ultrasonic Fracture Imager

The Geothermal Ultrasonic Fracture Imager project has a goal to develop a wireline ultrasonic imager that is capable of operating in temperatures up to 300°C (572°F) and depths up to 10 km (32,808 ft). This will address one of the critical needs in any EGS development of understanding the hydraulic flow paths in the reservoir. The ultrasonic imaging is well known in the oil and gas industry as one of the best methods for fracture evaluation; providing both high resolution and complete azimuthal coverage of the borehole. This enables fracture detection and characterization, both natural and induced, providing information as to their location, dip direction and dip magnitude. All of these factors are critical to fully understand the fracture system to enable the optimization of the thermal drainage through injectors and producers in a geothermal resource.

58 GEOSCIENCES↗

Feasibility of a Deep Direct-Use Geothermal System at the University of Illinois Urbana-Champaign

This study assesses the feasibility of using deep direct-use (DDU) geothermal energy in agricultural research facilities on the University of Illinois at Urbana-Champaign campus to exploit low-temperature sedimentary basins, such as the Illinois Basin. Subsurface components of the system include extraction and injection wells and downhole pumps. Surface equipment includes heat pumps/exchangers, and fluid transport and monitoring systems. Two geologic formations in the region exhibit a potential as sources for geothermal energy, based on pre initial temperatures and flow rates of fluids. The St. Peter and Mt. Simon Sandstones lie at depths of 634 and 1,280 m, respectively. Geocellular modeling is used to characterize the reservoirs. A St. Peter Sandstone model was made for an area south of the campus. Petrophysical and geothermal properties used are based on data from the closest wells penetrating the formations. Characterization of the Mt. Simon Sandstone is in progress and is not discussed here. Extraction and injection flows simulated with different wellbore configurations provide estimates of fluid flow out of and into the reservoir. The models are used to optimize flow rates, bottomhole pressure, and temperature of the produced fluid. Individual wellbore models simulate subsurface heat loss and gain, providing guidance on the optimal type and amount of insulation in the wellbore. Design of the surface facilities will address aspects of fluid delivery, heat exchange, capital operating costs, heat loss, and corrosion. Heat capacity and flow rates are assessed to estimate life-cycle costs and benefits, including the environmental benefits of reducing greenhouse gases and water use and increased energy efficiency. A preliminary analysis of surface configurations for the DDU system (including cascading applications) based on building heat loads is being conducted to identify multiple system designs that will maximize performance, energy efficiency, and cost recovery.

15 GEOTHERMAL ENERGY↗

Coupling Subsurface and Above-Surface Models for Optimizing the Design of Borefields and District Heating and Cooling Systems

Accurate dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange for seasonal energy storage. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes without flowing groundwater. While detailed simulation tools for subsurface heat and mass transfer exist, these fall short in simulating above-surface energy systems. To support the design and operation of such systems, the study developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the subsurface. For the first, it uses the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, it uses the TOUGH simulator. The TOUGH family of codes can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. The study validated the coupled modeling approach by comparing the simulation results with one from the g-function based ground response model. It then looked into effects when the water table and the regional groundwater flow are considered in the ground, from the perspective of heat exchange between borehole and ground, and the electrical consumption of the district heating and cooling systems. To access the simulation models, please find the links in the submission: -- For coupled approach validation: see model Buildings.Fluid.Geothermal.Borefields.Examples.BorefieldsWithTough and Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from the "Modelica Building Library" resource, branch issue1495_tough_interface, commit a2667c0. -- For the study of the effect of water table: see model Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO, commit 760de49. -- For the study of the effect of regional groundwater flow: see Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO_3D, commit c2a2d2a. The coupling interface script "GrounResponse.py" can be found from the above links in the folder Buildings/Resources/Python-Sources. Also, the needed files for TOUGH simulation are in the folder Buildings/Resources/Python-Sources/ToughFiles that can be accessed through the above links. A brief description of these files is given below; detailed specifications for the first three files may be found in the TOUGH3 Users Guide (Jung et al., 2018) https://tough.lbl.gov/documentation/tough-manuals/. (1) INCON - initial conditions for each grid block (2) INFILE - main input file with material properties and control parameters (3) MESH - description of the computational grid (4) readsave - Modelica/TOUGH interface program: read the final output of TOUGH simulation after TOUGH time step and prepare for transfer to Modelica for next Modelica time step (5) readsave.inp - input parameters for program readsave (6) writeincon - Modelica/TOUGH interface program: write the output of Modelica after Modelica time step and prepare for transfer to TOUGH as initial conditions for the next TOUGH step (7) writeincon.inp - input parameters for program writeincon

15 GEOTHERMAL ENERGY↗