Search NASA⌕ Search

SEARCH · Search NASA

Results for “granular compaction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Field-gradient partitioning for fracture and frictional contact in the material point method: Field-gradient partitioning for fracture and frictional contact in the material point method [Fracture and frictional contact in material point method using damage-field gradients for velocity-field partitioning]

Contact and fracture in the material point method require grid-scale enrichment or partitioning of material into distinct velocity fields to allow for displacement or velocity discontinuities at a material interface. We present a new method which a kernel-based damage field is constructed from the particle data. The gradient of this field is used to dynamically repartition the material into contact pairs at each node. Our approach avoids the need to construct and evolve explicit cracks or contact surfaces and is therefore well suited to problems involving complex 3-D fracture with crack branching and coalescence. A straightforward extension of this approach permits frictional ‘self-contact’ between surfaces that are initially part of a single velocity field, enabling more accurate simulation of granular flow, porous compaction, fragmentation, and comminution of brittle materials. Finally, numerical simulations of self contact and dynamic crack propagation are presented to demonstrate the accuracy of the approach.

97 MATHEMATICS AND COMPUTING↗

Dam-Break Flow Measurements of Liquid–Granular Mixtures in a Channelized Reservoir

Dam-break flows of granular materials exhibit a complex non-Newtonian rheology, which is strongly influenced by various factors, such as the characteristics of the granular material, the degree of initial compaction, and saturation level of the granular matrix. Specially adapted nonintrusive techniques are required to investigate these flows in the laboratory. This paper investigated the nonintrusive technique of image analysis. The methodologies used in the measurement of bulk flow parameters, such as flow depth, front velocity, and flow rate, and the extraction of detailed flow characteristics such as velocity profiles, were discussed in the context of a series of granular dam-break flow experiments. These experiments were performed under three types of initial conditions: dry, saturated (water filling the pore space), and submerged (a layer of saturated granular material submerged under water) using four types of granular materials—PET pellets, crushed walnut shells, urea, and sand—with grain sizes ranging from 200 μm to 2.9 mm. High-speed cameras were used to capture the evolution and local properties of the flow, such as velocity fields using particle image velocimetry (PIV). Bulk properties of the flow were obtained by tracking the surface profile of the granular matrix and the water table. The extracted profiles were used to measure the evolution of the volume of the granular matrix and the fluid phase separately upstream and downstream of the gate, which allowed measuring the dilatancy (increase in pore space). The study showed that the image analysis techniques are versatile and can be adapted to measure different flow parameters in a variety of granular flows to better understand and analyze their complex behavior. Finally, the advantages and drawbacks of each image analysis technique were discussed and best-practice recommendations were provided.

42 ENGINEERING↗

Why Firn Quakes

Snow dampens sounds, but anecdotal reports concisely describe audible propagating collapse events—firnquakes—in Antarctic and Arctic snowfields. We propose combining granular and continuum mechanics to form a testable theory for conditioning, triggering, and propagation of firnquakes consistent with scarce data. A central condition for collapse events is unconsolidated firn at depth. As firn grains compact, stresses are transmitted along force chains which carry the overburden and transition into a continuous medium by pressure sintering. This granular legacy creates solid-like supports of denser layers that keep the material below unconsolidated. Dynamic amplification triggers local brittle failure of the supports, which induces a cascade of collapse propagation. Using bulk density from ice cores as proxy for stiffness, we find the flexural wave speed by collapsing supports matches the recorded firnquake velocities on the order of 100 m/s. Our theory is to be tested in firn sheets and other compacting granular materials.

Voigtländer, A. [Lawrence Berkeley National Labora↗

Pore-scale investigation on stress-dependent characteristics of granular packs and the impact of pore deformation on fluid distribution

Understanding the effect of changing stress conditions on multiphase flow in porous media is of fundamental importance for many subsurface activities including enhanced oil recovery, water drawdown from aquifers, soil confinement, and geologic carbon storage. Geomechanical properties of complex porous systems are dynamically linked to flow conditions, but their feedback relationship is often oversimplified due to the difficulty of representing pore-scale stress deformation and multiphase flow characteristics in high fidelity. In this work, we performed pore-scale experiments of single- and multiphase flow through bead packs at different confining pressure conditions to elucidate compaction-dependent characteristics of granular packs and their impact on fluid flow. A series of drainage and imbibition cycles were conducted on a water-wet, soda-lime glass bead pack under varying confining stress conditions. Simultaneously, X-ray micro-CT was used to visualize and quantify the degree of deformation and fluid distribution corresponding with each stress condition and injection cycle. Micro-CT images were segmented using a gradient-based method to identify fluids (e.g., oil and water), and solid phase redistribution throughout the different experimental stages. Changes in porosity, tortuosity, and specific surface area were quantified as a function of applied confining pressure. Results demonstrate varying degrees of sensitivity of these properties to confining pressure, which suggests that caution must be taken when considering scalability of these properties for practical modeling purposes. Changes in capillary number with confining pressure are attributed to the increase in pore velocity as a result of pore contraction. Furthermore, this increase in pore velocity was found to have a marginal impact on average phase trapping at different confining pressures.

58 GEOSCIENCES↗

CMS High Granularity Calorimeter ECON-D ASIC overview and radiation testing results

The Compact Muon Solenoid (CMS) Experiment’s High Granularity Calorimeter (HGCAL) upgrade replaces the CMS electromagnetic and hadronic endcap calorimeters in preparation for the high-rate and high-radiation environment of the High Luminosity LHC. To effectively use the over 6 million channels of this highly-segmented “imaging” calorimeter, CMS is pioneering very front-end data compression with the Endcap Concentrator (ECON) ASICs – the ECON-T for the trigger path and the ECON-D for the data path. These 65 nm CMOS ASICs are radiation tolerant (200 Mrad) and low-power (< 2.5 mW/channel). In June 2023, we received the first full-functionality prototype of the data path concentrator ASIC, the ECON-D-P1. This talk will present an overview of the ECON-D-P1, summarize functionality and system testing, and present results from both Total Ionizing Dose (TID) and Single Event Effect (SEE) testing campaigns completed in summer 2023, validating the ECON-D radiation tolerant performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Reconfigurable Neural Network ASIC for Detector Front-End Data Compression at the HL-LHC

Despite advances in the programmable logic capabilities of modern trigger systems, a significant bottleneck remains in the amount of data to be transported from the detector to off-detector logic where trigger decisions are made. We demonstrate that a neural network (NN) autoencoder model can be implemented in a radiation-tolerant application-specific integrated circuit (ASIC) to perform lossy data compression alleviating the data transmission problem while preserving critical information of the detector energy profile. For our application, we consider the high-granularity calorimeter from the Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider. The advantage of the machine learning approach is in the flexibility and configurability of the algorithm. By changing the NN weights, a unique data compression algorithm can be deployed for each sensor in different detector regions and changing detector or collider conditions. To meet area, performance, and power constraints, we perform quantization-aware training to create an optimized NN hardware implementation. The design is achieved through the use of high-level synthesis tools and the hls4ml framework and was processed through synthesis and physical layout flows based on a low-power (LP)-CMOS 65-nm technology node. The flow anticipates 200 Mrad of ionizing radiation to select gates and reports a total area of 3.6 mm 2 and consumes 95 mW of power. The simulated energy consumption per inference is 2.4 nJ. Furthermore, this is the first radiation-tolerant on-detector ASIC implementation of an NN that has been designed for particle physics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of CMS High Granularity Calorimeter Silicon Sensors

This poster seeks to characterize the quality of silicon sensors that will potentially be used in the High Granularity Calorimeter at the Compact Muon Solenoid detector. The silicon sensors used in this analysis were provided by the companies Hammatsu and NHanced. The silicon sensors were characterized by measuring the capacitance of the MOS and diode structures on the sensor's test structures both before and after irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aging of Pentaerythritol Tetranitrate (PETN)

Pentaerythritol tetranitrate (PETN) is a relatively sensitive explosive used in many electroexplosive devices as well as in medicine. Of primary interest to LLNL is its use in items such as exploding bridgewire (EBW) detonators and exploding bridge foil initiators (EFI). In these devices the crystalline powder is pressed into a granular, low-density compact that can be initiated by an exploding wire or foil. The long-term stability of this pressed compact is of interest to weapon stockpile lifetime prediction studies. Key points about potential aging mechanisms can be summarized as follows: (1) There are a number of factors that can contribute to PETN instability. These include particle size, polymorphic phase transitions, crystal structure, impurities, moisture, occlusions, chemical incompatibility and biological (microorganism) action. of these factors the most important for long-term aging of high surface area powders used in detonators appears to be that of particle size growth. (2) There is a great deal of literature on the thermal degradation kinetics of PETN, unfortunately much of it with little bearing on ambient temperature aging during long-term storage. PETN is very stable with respect to thermal decomposition. Low-temperature thermal studies have not revealed evidence of chemical degradation products in archived PETN. Data extrapolated to 30 C predicts a half-life of 12 million years. (3) Moisture seems to lower the activation energy for and accelerate the decomposition of PETN. (4) External drivers affecting stability include temperature, moisture, radiation fields, and stress, while internal drivers include residual solvents, and impurities. Temperature affects kinetic processes of crystal growth such as adsorption, desorption, and diffusion rates of molecules on the surface of PETN crystals. A low-level radiation field may induce unexpected changes in the chemical makeup of PETN and its homologue impurities. Stress at high pressure points caused by crystalline surface irregularities may cause a decrease in surface area over time due to smoothing of contact points and sintering. PETN has been found to contain a number of impurities, including homologues, pentaerythryl ethers with a mixture of hydroxyl and nitrate functional groups, and organic salts, that can alter its physical and chemical properties. (5) The processes of sublimation/recrystallization and surface diffusion are important processes that can cause changes in PETN crystal morphology, particle size distribution and specific surface area. Sublimation feeds a process called Ostwald ripening, which involves the spontaneous growth of larger crystals from those of smaller size. This process proceeds with age regardless of storage conditions unless the crystals are treated to retard growth. The coarsening mechanisms include Ostwald ripening, 'sintering', and surface diffusion. The latter has not been experimentally observed, but a molecular modeling approach has attempted to investigate this phenomenon theoretically. (6) Threshold test fire, particle size distribution, specific surface area, thermal analysis, chemical analysis, powder compact specific surface area and density are approaches that have been used in the attempt to assess changes attributable to aging of PETN, with varying results. The biggest problem lies in the aging mechanism itself, which likely influences small changes in morphology, both internal and external, and particle size distribution changes on a scale too small to reliably monitor. Other aspects, such as subtle changes in density profiles within pressed powder compacts, may be beyond the capability of current technology to assess. Crystal growth significant enough to affect the PETN particle size distribution is expected to impact detonator performance. (7) Factors relevant to stabilizing particle size growth include crystal morphology, powder surface area and particle size distribution; crystal density and internal defects; and powder compact density and density gradients.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Assessment of Using Vibrational Compaction of Calcined HLW and LLW in DWPF Canisters

Since 1963, the INEL has calcined almost 8 million gallons of liquid mixed waste and liquid high-level waste, converting it to some 1.1 million gallons of dry calcine (about 4275.0 m3), which consists of alumina-and zirconia-based calcine and zirconia-sodium blend calcine. In addition, if all existing and projected future liquid wastes are solidified, approximately 2,000 m3 of additional calcine will be produced primarily from sodium-bearing waste. Calcine is a more desirable material to store than liquid radioactive waste because it reduces volume, is much less corrosive, less chemically reactive, less mobile under most conditions, easier to monitor and more protective of human health and the environment. This paper describes the technical issue involved in the development of a feasible solution for further volume reduction of calcined nuclear waste for transportation and long term storage, using a standard DWPF canister. This will be accomplished by developing a process wherein the canisters are transported into a vibrational machine, for further volume reduction by about 35%. The random compaction experiments show that this volume reduction is achievable. The main goal of this paper is to demonstrate through computer modeling that it is feasible to use volume reduction vibrational machine without developing stress/strain forces that will weaken the canister integrity. Specifically, the paper presents preliminary results of the stress/strain analysis of the DWPF canister as a function of granular calcined height during the compaction and verifying that the integrity of the canister is not compromised. This preliminary study will lead to the development of better technology for safe compactions of nuclear waste that will have significant economical impact on nuclear waste storage and treatment. The preliminary results will guide us to find better solutions to the following questions: 1) What are the optimum locations and directions (vertical versus horizontal or both of them) of applying the vibrational forces? 2) What is best mode of operation: first fill the canister with calcined waste and then vibrate it and refill it again, or apply vibrational forces during the filling process. By optimum or best we mean less creation of stress/strain forces during the volume reduction vibration process. Lessons learnt: This preliminary study shows that; 1) The maximum stress concentration always occurs in the canister wall, however its location varies and depends on the loading condition, and vibration process. 2) The proposed vibrational process would not cause any damages to the granulated calcined waste. 3) The first natural frequency of the longitudinal vibration of the canister is around 400 Hz, which is far away from the applied vibrational frequencies and from possibility of resonance phenomena that may cause damage to the canister 4) The relationship between the maximum internal stress and the frequency of the applied load is not parabolic. 5) The mechanical properties of the granulated calcined nuclear waste have small impact on the internal stress of the canister. Finally, the calculated data suggested that applying vibrational forces will keep the entire canister whole without any indication of development defects, and will have significant economical benefits of handling HLW and LLW in calcined forms, from waste manipulation, storage and transportation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Granular bed consolidation, creep, and armoring under subcritical fluid flow

In this work, we show that a freshly sedimented granular bed settles and creeps forward over extended periods of time under an applied hydrodynamic shear stress which is below the critical value for bedload transport. The rearrangements are found to last over a timescale which is millions of times the sedimentation timescale of a grain in the fluid. Compaction occurs uniformly throughout the bed, but creep is observed to decay exponentially with depth and decreases over time. The granular volume fraction in the bed is found to increase logarithmically, saturating at the random close packing value Φ rcp ≈ 0.64, while the surface roughness is observed to remain essentially unchanged. We demonstrate that an increasingly higher shear stress is required to erode the bed, after a subcritical shear is applied, which results in an increase in its volume fraction. Thus, we find that bed armoring occurs due to a deep shear-induced relaxation of the bed toward the volume fraction associated with the glass transition.

58 GEOSCIENCES↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-dependent thermal degradation of lost circulation materials in geothermal systems

Treatment of lost circulation can represent anywhere from 5 to 25 % of the cost in drilling geothermal wells. The cost of the materials used for lost circulation treatment is less important than their effectiveness at reducing fluid losses. In geothermal systems, the high temperatures (>90 °C) are expected to degrade many commonly used lost circulation materials over time. This degradation could compromise different materials ability to mitigate fluid loss, creating more non-productive time as multiple treatments are needed, but may result in recovering desired permeability zones within the reservoir section over time. This research aimed to study how thermal degradation of eight different lost circulation materials affected their properties relevant to sealing loss zones in geothermal wells. Here, mass loss experiments were conducted with each material at temperatures of 90–250 °C for 1–42 days to measure the breakdown of the material at geothermal conditions, collecting gases during several experiments to determine the waste produced during degradation. Compaction experiments were conducted with the degraded materials to show how temperatures reduced the rigidity and increased packing of the materials. Viscosity tests were conducted to show the impact of different materials on drilling fluid rheology. Microscope observations were conducted to characterize the alterations to each material due to thermal degradation. Organic materials tend to degrade more than inorganic materials, with organics like microcellulose, cotton seed hulls and sawdust losing 30–50 % of their mass after 1 day of heating at 200 °C, while inorganics like magma fiber only lose ~5–10 % of its mass after one day of heating at 200 °C. Granular materials are the strongest when compacted despite any mass loss, while fibrous and flaky materials are fairly weak and breakdown easily under stress. The materials do not generally affect fluid rheology unless they have a viscosifying agent as part of the mixture. Microscopic analysis showed that more rigid materials like microcellulose and cedar fiber degrade in brittle manners with splitting and fracturing, while others like cotton seed hulls degrade in more ductile manners forming meshes or clumps of material. The thermal breakdown of lost circulation materials tested suggests that each material should also be classified by its degree of thermal degradability, as at certain temperatures the materials can lose the capability to bridge loss zones around the wellbore.

15 GEOTHERMAL ENERGY↗

Evidence for Methane Segregation at the Surface of Pluto

In May 1995, a set of spectrophotometric curves of the system Pluto-Charon was recorded with the UKIRT telescope equipped with the spectrometer CGS4. As for the previous observations, the spectra cover a part of the near infrared range, between 1.4 and 2.55 micrometers, but with a higher resolution of approximately 700. In both the 1992 and 1995 data, the existence of solid methane is confirmed by numerous absorption bands, and the carbon monoxide and the nitrogen ices are identified by their respective signatures at 2.35 and 2.15 um. The solid nitrogen seems to be the principal icy component and forms a matrix in which the CH4 and CO molecules are diluted. However a spectroscopic analysis of the 1995 observations indicates that pure methane may coexist with its diluted phase in N2. In order to derive the horizontal and vertical distribution of these different species and to obtain some quantitative information about their characteristics, we have modeled the spectrum of May 15 that corresponds to the maximum of Pluto's visible light curve. This was achieved by means of a radiative transfer algorithm dealing with compact and stratified media. Among the various representations we have tested to describe the surface of Pluto, only a geographical mixture of three distinct units explains all the significant structures of the analyzed spectrum. The first unit is a thin granular layer of pure CH4 covering a compact polycrystalline substratum of N2-CH4-CO, which are in a molecular mixture (concentrations of and CO of the order of 0.45%, 0.1-0.2% respectively). It covers about 70% of the observed area and corresponds to volatile deposits that are sublimating under solar illumination. The second unit is either (a) a single thick layer of pure granular methane or (b) a unit similar to the first unit but with the two components inverted (i.e. with CH4 forming a substratum and the N2-CH4-CO mixture a superficial layer of fine grains). Covering 20% of the surface, it represents some old surfaces that have been sublimated for a long time, and eventually recovered later by very small amounts of fresh deposits of the molecular mixture N2-CH4-CO. Finally, the third unit may result from the condensation of very fine grains of nearly pure N2. It covers the remainder of the surface (about 10%). All these results allow a better understanding of the processes of deposition, metamorphism, sublimation and transport affecting the different ices detected on Pluto during its climatic cycles.

Doute, S.↗

Gas Permeability of Lunar Regolith Simulants

Lunar lander descent engines produce plume-surface interactions (PSI) effect that can generate high-speed regolith ejecta which can pose a risk to surface and orbital assets. The physics of plume-surface interactions during the descent and landing of a lunar lander depends on the gas permeability of the lunar surface regolith. This presentation will discuss gas permeability measurements that have been performed at NASA Kennedy Space Center to help inform the development of plume-surface interaction models and large-scale PSI ground tests. Results will be presented of gas permeability measurements for lunar regolith simulants that were conducted under vacuum conditions as a function of the granular mineral material's mass density, compaction, and water content.

gas permeability↗

First beam tests of prototype silicon modules for the CMS High Granularity Endcap Calorimeter

The High Luminosity phase of the Large Hadron Collider will deliver 10 times more integrated luminosity than the existing collider, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry. As part of its upgrade program, the Compact Muon Solenoid collaboration is designing a high-granularity calorimeter (HGCAL) to replace the existing endcap calorimeters. It will feature unprecedented transverse and longitudinal readout and triggering segmentation for both electromagnetic and hadronic sections. The electromagnetic section and a large fraction of the hadronic section will be based on hexagonal silicon sensors of 0.5–1 cm 2 cell size, with the remainder of the hadronic section being based on highly-segmented scintillators with silicon photomultiplier readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection. First hexagonal silicon modules, using the existing Skiroc2 front-end ASIC developed for CALICE, have been tested in beams at Fermilab and CERN in 2016. Here, we present results from these tests, in terms of system stability, calibration with minimum-ionizing particles and resolution (energy, position and timing) for electrons, and the comparisons of these quantities with GEANT4-based simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗