Search NASA⌕ Search

SEARCH · Search NASA

Results for “gravity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impact cratering in low-gravity environments - Results of reconnaissance experimentation on the NASA KC-135A reduced-gravity aircraft

A program of flight experimentation was performed on the NASA KC-135A reduced-gravity aircraft to evaluate the potential for conducting impact experiments in reduced-gravity environments and to collect impact-cratering data at gravity levels below 1 g. Lead pellets were launched into coarse-grained sand at velocities of about 65-130 m/sec while the gravitational acceleration was maintained at 0.59-0.05 g. A total of 64 craters were studied and, after allowance is made for the atmospheric pressure over the target (0.83 atm), their diameters are found to have been consistent with scaling predictions made on the basis of ground-based experimentation. Formation times were also obtained for 33 of these craters and constitute a distribution that is somewhat different from that described by the ground-based data. Nevertheless, the KC-135 data set as a whole falls on the trend formed by the ground-based results. The overall agreement between the two data sets attests to the stability of the aircraft as a platform for impact experimentation.

Cintala, M. J.↗

Gravity field information from Gravity Probe-B

The Gravity Probe-B Mission will carry the Stanford Gyroscope relativity experiment into orbit in the mid 1990's, as well as a Global Positioning System (GPS) receiver whose tracking data will be used to study the earth gravity field. Estimates of the likely quality of a gravity field model to be derived from the GPS data are presented, and the significance of this experiment to geodesy and geophysics are discussed.

Smith, D. E.↗

Measuring Greenland Ice Mass Variation With Gravity Recovery and the Climate Experiment Gravity and GPS

The response of the Greenland ice sheet to climate change could significantly alter sea level. The ice sheet was much thicker at the last glacial maximum. To gain insight into the global change process and the future trend, it is important to evaluate the ice mass variation as a function of time and space. The Gravity Recovery and Climate Experiment (GRACE) mission to fly in 2001 for 5 years will measure gravity changes associated with the current ice variation and the solid earth's response to past variations. Our objective is to assess the separability of different change sources, accuracy and resolution in the mass variation determination by the new gravity data and possible Global Positioning System (GPS) bedrock uplift measurements. We use a reference parameter state that follows a dynamic ice model for current mass variation and a variant of the Tushingham and Peltier ICE-3G deglaciation model for historical deglaciation. The current linear trend is also assumed to have started 5 kyr ago. The Earth model is fixed as preliminary reference Earth model (PREM) with four viscoelastic layers. A discrete Bayesian inverse algorithm is developed employing an isotropic Gaussian a priori covariance function over the ice sheet and time. We use data noise predicted by the University of Texas and JPL for major GRACE error sources. A 2 mm/yr uplift uncertainty is assumed for GPS occupation time of 5 years. We then carry out covariance analysis and inverse simulation using GRACE geoid coefficients up to degree 180 in conjunction with a number of GPS uplift rates. Present-day ice mass variation and historical deglaciation are solved simultaneously over 146 grids of roughly 110 km x 110 km and with 6 time increments of 3 kyr each, along with a common starting epoch of the current trend. For present-day ice thickness change, the covariance analysis using GRACE geoid data alone results in a root mean square (RMS) posterior root variance of 2.6 cm/yr, with fairly large a priori uncertainties in the parameters and a Gaussian correlation length of 350 km. Simulated inverse can successfully recover most features in the reference present-day change. The RMS difference between them over the grids is 2.8 cm/yr. The RMS difference becomes 1.1 cm/yr when both are averaged with a half Gaussian wavelength of 150 km. With a fixed Earth model, GRACE alone can separate the geoid signals due to past and current load fairly well. Shown are the reference geoid signatures of direct and elastic effects of the current trend, the viscoelastic effect of the same trend starting from 5 kyr ago, the Post Glacial Rebound (PGR), and the predicted GRACE geoid error. The difference between the reference and inverse modeled total viscoelastic signatures is also shown. Although past and current ice mass variations are allowed the same spatial scale, their geoid signals have different spatial patterns. GPS data can contribute to the ice mass determination as well. Additional information is contained in the original.

Wu, Xiao-Ping↗

Development of gravity-sensing organs in altered gravity

Experiments are described in which the development of the gravity-sensing organs was studied in newt larvae reared in microgravity on the IML-2 mission and in Aplysia embryos and larvae reared on a centrifuge at 1 to 5 g. In Aplysia embryos, the statolith (single dense mass on which gravity and linear acceleration act) was reduced in size in a graded fashion at increasing g. In early post-metamorphic Aplysia or even in isolated statocysts from such animals, the number of statoconia produced is reduced at high g. Newt larvae launched before any of the otoconia were formed and reared for 15 days in microgravity had nearly adult labyrinths at the end of the IML-2 mission. The otoliths of the saccule and utricle were the same size in flight and ground-reared larvae. However, the system of aragonitic otoconia produced in the endolymphatic sac in amphibians was much larger and developed earlier in the flight-reared larvae. At later developmental stages, the aragonitic otoconia enter and fill the saccule. One flight-reared larva was maintained for nine months post-flight and the size of the saccular otolith, as well as the volume of otoconia within the endolymphatic sac, were considerably larger than in age-matched, ground-reared newts. This suggests that rearing in microgravity initiates a process that continues for several months after introduction to 1-g, which greatly increases the volume of otoconia. The flight-reared animal had abnormal posture, pointing its head upward, whereas normal ground-reared newts always keep their head horizontal. This suggests that rearing for even a short period in microgravity can have lasting functional consequences in an animal subsequently reared in 1-g conditions on Earth.

STS-65 Shuttle Project↗

Some physiological effects of alternation between zero gravity and one gravity

The anatomy and physiology of the healthy vestibular system and the history of its study, maintenance of muskuloskeletal fitness under low-gravity conditions, tests of motion sickness, and data and techniques on testing subjects in a slow rotation room, are covered. Components of the inner ear labyrinth and their behavior in relation to equilibrium, gravity and inertial forces, motion sickness, and dizziness are discussed. Preventive medicine, the biologically effective force environment, weightlessness per se, activity in a weightless spacecraft, exercizing required to maintain musculoskeletal function, and ataxia problems are dealt with.

Graybiel, A.↗

Mechanics of liquid helium in a partially filled rotating dewar in low gravity with application to Gravity Probe-B

The Gravity Probe-B spacecraft is composed largely of a liquid helium dewar containing an experiment package. It is shown that an unsymmetric liquid helium distribution in the dewar can cause unacceptably high forces, gravitational and gravity gradient forces, at the experiment location. It is further shown that for the planned spacecraft configuration and operational parameters, it is very likely that the liquid helium distribution in the dewar will be unsymmetric. The required symmetry can be attained by using higher operational spacecraft rotation rates.

Schafer, C. F.↗

Modeling of zero gravity venting: Studies of two-phase heat transfer under reduced gravity

The objective is to predict the pressure response of a saturated liquid-vapor system when undergoing a venting or depressurization process in zero gravity at low vent rates. An experimental investigation of the venting of cylindrical containers partially filled with initially saturated liquids was previously conducted under zero-gravity conditions and compared with an analytical model which incorporated the effect of interfacial mass transfer on the ullage pressure response during venting. A new model is presented to improve the estimation of the interfacial mass transfer. Duhammel's superposition integral is incorporated to approximate the transient temperature response of the interface, treating the liquid as a semi-infinite solid with conduction heat transfer. Account is also taken of the condensation taking place within the bulk of a saturated vapor as isentropic expansion takes place. Computational results are presented for the venting of R-11 from a given vessel and initial state for five different venting rates over a period of three seconds, and compared to prior NASA experiments. An improvement in the prediction of the final pressure takes place, but is still considerably below the measurements.

Merte, H., Jr.↗

Solitary waves in the resonant phenomenon between a surface gravity wave packet and an internal gravity wave

A two-layer inviscid incompressible fluid system of intermediate depth is considered. A multiple-scales perturbation technique is applied to the basic equations and boundary conditions for a two-layer fluid system to derive a system of weakly nonlinear partial integrodifferential equations governing the resonant interaction between a surface gravity wave packet and an internal gravity wave at an intermediate depth, providing a bridge between the existing shallow and deep fluid theories. The convolution integral term in these equations accounts for the dispersion in the lower-layer fluid. An iterative fast Fourier transform scheme is developed to find solitary wave solutions to this system of equations. The overtaking collision of two pairs of solitary waves, simulated using a spectral method, is found to be inelastic. It is found that the amplitude of the solitary waves changes slightly after the collision. The phase shifts these solitary waves undergo was calculated numerically.

Sepulveda, Nicasio↗

Femur-bending properties as influenced by gravity. V - Strength vs. calcium and gravity in rats exposed for 2 weeks

The dependence of gravitationally related changes in femur bone strength on the comparable changes in calcium content was investigated in rats exposed to chronic simulations of altered gravity from the 28th to 42nd day of age. Zero G was simulated by harness suspension and 3 G by centrifugation. Bone strength (S) was determined by bending (using modified quasi-static cantilever bending methods and equipment described by Wunder et al., 1977 and 1979) and Ca content (C, by mass pct) determined by atomic absorption spectrometry; results were compared with data obtained on both normal and harnessed control animals at 1 G. Multiple regression showed significant dependence of S upon earth's gravity, independent from C, for which there was no significant coefficient of partial regression. It is suggested that the lack of S/C correlation might have been due to the fact that considerable fraction of the calcium in these young, developing bones has not yet crystallized into the hydroxyapatite which provides strength.

Wunder, Charles C.↗

Global gravity survey by an orbiting gravity gradiometer

The scientific aims, design, and mission profile of the Superconducting Gravity Gradiometer Mission (SGGM), a NASA spacecraft mission proposed for the late 1990s, are discussed and illustrated with drawings and diagrams. SGGM would complement the two other planned gravimetry missions, GRM and Aristoteles, and would provide gravitational-field measurements with accuracy 2-3 mGal in 55 x 55-km blocks. The principal instruments are a (1) three-axis superconducting gravity gradiometer with intrinsic sensitivity 100 microeotvos/sq rt Hz, (2) a six-axis superconducting accelerometer with sensitivity 100 fg(E)/sq rt Hz linear and 10 prad/sec squared sq rt Hz angular, and (3) a six-axis shaker for active control of the platform. Consideration is given to the error budget and platform requirements, the orbit selection criteria, and the spacecraft design.

Paik, Ho Jung↗

Response of gravity level fluctuations on the Gravity Probe-B spacecraft propellant system

Time-dependent computations have been performed to investigate the dynamical behaviors of fluid under a microgravity environment. A computer algorithm is introduced which can be used to simulate the fluid behavior in that environment, in particular the excitation of sloshing waves due to different gravity environments and rotation speeds. A suggestion on the proper handling and managing of cryogenic fluid propellant to be used in the Gravity Probe-B spacecraft propulsion is made.

Hung, R. J.↗

Estimation of local planetary gravity fields using line of sight gravity data and an integral operator

A novel method is presented for mapping line-of-sight gravity data (LOSGD) joining planetary probes and observers during Doppler tracking operations, with a view to geodetic and geophysical applications. LOSGD are in this case mapped as gravity anomalies along a radial direction, at constant altitude, using an inversion procedure in conjunction with a Tikhonov-Arsenine regularization method. The application of different regularization-parameter choices to a synthetic case is followed by application to the real case of Pioneer-Venus orbiter data for Venus' Gula Mons.

Barriot, J. P.↗

Analysis of crustal structure of Venus utilizing residual Line-of-Sight (LOS) gravity acceleration and surface topography data. A trial of global modeling of Venus gravity field using harmonic spline method

To construct Venus' gravity disturbance field (or gravity anomaly) with the spacecraft-observer line of site (LOS) acceleration perturbation data, both a global and a local approach can be used. The global approach, e.g., spherical harmonic coefficients, and the local approach, e.g., the integral operator method, based on geodetic techniques are generally not the same, so that they must be used separately for mapping long wavelength features and short wavelength features. Harmonic spline, as an interpolation and extrapolation technique, is intrinsically flexible to both global and local mapping of a potential field. Theoretically, it preserves the information of the potential field up to the bound by sampling theorem regardless of whether it is global or local mapping, and is never bothered with truncation errors. The improvement of harmonic spline methodology for global mapping is reported. New basis functions, a singular value decomposition (SVD) based modification to Parker & Shure's numerical procedure, and preliminary results are presented.

Fang, Ming↗

Intravenous Fluid Mixing in Normal Gravity, Partial Gravity, and Microgravity: Down-Selection of Mixing Methods

The missions envisioned under the Vision for Space Exploration will require development of new methods to handle crew medical care. Medications and intravenous (IV) fluids have been identified as one area needing development. Storing certain medications and solutions as powders or concentrates can both increase the shelf life and reduce the overall mass and volume of medical supplies. The powders or concentrates would then be mixed in an IV bag with Sterile Water for Injection produced in situ from the potable water supply. Fluid handling in microgravity is different than terrestrial settings, and requires special consideration in the design of equipment. This document describes the analyses and down-select activities used to identify the IV mixing method to be developed that is suitable for ISS and exploration missions. The chosen method is compatible with both normal gravity and microgravity, maintains sterility of the solution, and has low mass and power requirements. The method will undergo further development, including reduced gravity aircraft experiments and computations, in order to fully develop the mixing method and associated operational parameters.

Niederhaus, Charles E.↗

A Statistical Filtering Approach for Gravity Recovery and Climate Experiment (GRACE) Gravity Data

We describe and analyze a statistical filtering approach for GRACE data that uses a parametrized model for the temporal evolution of the GRACE coefficients. After least-squares adjustment, a statistical test is performed to assess the significance of the estimated parameters. If the test is passed, the parameters are used by the filter in the reconstruction of the field; otherwise they are rejected. The test is performed, and the filter is formed, separately for annual components of the model and the trend. This new approach is distinct from Gaussian smoothing since it uses the data themselves to test for specific components of the time-varying gravity field. The statistical filter appears inherently to remove most of the "stripes" present in the GRACE fields, although destriping the fields prior to filtering seems to help the trend recovery. We demonstrate that the statistical filter produces reasonable maps for the annual components and trend. We furthermore assess the statistical filter for the annual components using ground-based GPS data in South America by assuming that the annual component of the gravity signal is associated only with groundwater storage. The un-destriped, statistically filtered field has a X2 value relative to the GPS data consistent with the best result from smoothing. In the space domain, the statistical filters are qualitatively similar to Gaussian smoothing. Unlike Gaussian smoothing, however, the statistical filter has significant sidelobes, including large negative sidelobes on the north-south axis, potentially revealing information on the errors, and the correlations among the errors, for the GRACE coefficients.

Davis. J. L.↗