Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

CyRRL (Cyber Resilient Reinforcement Learning for grid voltage control) [SWR-24-115]

This codebase contains a multi-agent, actor-critic reinforcement learning implementation for cyber-resilient grid voltage control. It uses a 123-bus OpenDSS system as the environment, with three-phase power flow translating nodal power injections into solved nodal voltages. The reward function penalizes deviations from nominal voltage as well as reactive power dispatch, while encouraging agents to take actions that result in fast convergence to nominal conditions. The codebase models false data injection attacks and includes functionality for training, testing, hyper-parameter tuning, and visualization.

Murphy, Sinnott [National Renewable Energy Laborat↗

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration

This paper presents an innovative wave energy conversion system that integrates an interleaved Cuk converter with advanced nonlinear control for seamless grid integration. The system efficiently extracts power on the DC side using the interleaved Cuk converter, while an inverter manages power transfer to the grid or load on the AC side. A nonlinear control architecture, based on the Lyapunov energy function, ensures stable and optimal operation under varying wave conditions, effectively addressing the challenges of variability and unpredictability inherent in wave energy. The proposed system also incorporates features to enhance power quality and minimize losses, making it a robust solution for renewable energy integration. The system's effectiveness in harnessing wave energy and achieving smooth grid integration is validated through comprehensive computer simulations in MATLAB/Simulink, with case study results demonstrating its capabilities.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Standard Library Plant Controller Model Specification for a Grid-Forming Hybrid Control Inverter-Based Resource (REPCGFM_C1)

This document describes a standard library plant controller model to interface with the grid-forming hybrid control inverter-based resource (IBR) model. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control algorithms to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Synchronization Control of Grid-Forming Inverters for Smooth Microgrid Transition

This paper develops an integrated synchronization control technique for a grid-forming inverter operating within a microgrid that can improve the microgrid's transients during microgrid transition operation. This integrated synchronization control includes the disconnection synchronization control and the reconnection synchronization control. The simulation results show that the developed synchronization control works effectively to smooth the angle change of the grid-forming inverter during microgrid transition operation. Thus, the microgrid's transients are significantly improved compared to the case without synchronization control.

control↗

Stability and Fidelity of Power-Hardware-in-the-Loop Using NREL's CGI

The presentation focuses on dynamic analysis of power hardware-in-the-loop (PHIL) experiments using National Renewable Energy Laboratory Flatirons Campus' grid simulator - 7MVA Controllable Grid Interface (CGI). A control diagram of typical PHIL experiment is described, and transfer functions of critical components are explained. An impedance-based definition of PHIL experiment bandwidth is defined using open loop transfer functions of the system. Further an example resistive divider circuit is introduced that is used to explain implication of PHIL on accuracy of simulation by comparing measured results against ideal expected signals. At the end the real-life PHIL simulation using Maui power system model is described showing various oscillation modes observed and discussing the meaning of these in context of dynamic bandwidth of simulation.

grid simulator↗

A Novel State-Constrained Primary Control for Grid-Forming Inverters

The problem of operating an AC microgrid with purely inverter-based generating units is considered, and a novel vector control for the constrained grid-forming (GFM) inverters is proposed. The design aims to achieve the primary control objectives of the GFM inverters: voltage establishment, synchronization, and voltage/frequency regulation. It is novel that the proposed control also ensures all operational variables constrained both real-time and for all the time except for low voltage during the period of grid forming. The constraints include frequency, output AC voltage, input DC power, and active/reactive power injections to the grid. Here, in this paper, outcomes of a detailed simulation are presented to demonstrated that the above design objectives are met and that the overall performance is superior due to its unique ability of simultaneously controlling the whole vectors of the inverter state and output.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tuning Phase Lock Loop Controller of Grid Following Inverters by Reinforcement Learning to Support Networked Microgrid Operations

The dynamic operation of networked microgrids leads to varying topological configurations and generator commitments and dispatches. These variations correspond to systems with different electrical characteristics. The fixed control gains of high-speed power electronic devices may result in undesirable system performance when the electrical characteristics change significantly. As such, it is necessary to tune the control gains of power electronics devices to adapt to the changing system characteristics. This paper uses observer-based reinforcement learning to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing system strengths, that would be seen in networked microgrid operations. Simulation results using an operational electric distribution system, modeled as networked microgrids, are presented to demonstrate the need and effectiveness of the proposed adaptive controls.

networked microgrids, reinforcement learning, grid↗

Passivity-Based Control of Grid Forming and Grid Following Converters in Microgrids

With the integration of more and more power electronics devices into the grid, it is not easy to guarantee the stability of the whole system due to the complexity of the control structure of various power converters. In this paper, we consider grid-forming and grid-following converters in one microgrid, in which the grid-forming converters support the voltage and frequency of the microgrid and the grid-following converters inject their maximum power into the microgrid. To handle the stability issue, the passivity principle is applied to guarantee the stability of the whole microgrid. We ensure every grid-following converter satisfies the passivity via the port-controlled Hamiltonian method. In addition, we apply the passivity-based proportional-resonant controller to the grid-forming converter. One of the advantages of the proposed method is that the phase lock loop system is eliminated, which may cause stability issues. Simulation results show that the proposed method can control the microgrid effectively.

Gui, Yonghao (Young)↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration: Preprint

This paper presents an innovative wave energy conversion system employing an interleaved Cuk converter and advanced nonlinear control for seamless integration with the grid. The proposed system utilizes the interleaved Cuk converter for efficient power extraction on the DC side, while an inverter facilitates power transfer to the grid or load on the AC side. A sophisticated nonlinear control architecture based on Lyapunov energy functions ensures stable and optimal operation under varying wave conditions. Case study results demonstrate the effectiveness of the proposed system, highlighting its ability to efficiently harness wave energy and seamlessly integrate with the grid, thus paving the way for sustainable and reliable renewable energy generation. The overall system is verified via computer simulations based on MATLAB/Simulink and various case study results are presented.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Securing Solar for the Grid: Extreme Control Whitepaper

Emerging standards outlining desired behaviors for Distributed Energy Resources (DER), such as IEEE 1547-2018, define several device-level control functions to regulate DER power injections/consumptions in response to locally sensed grid conditions. The ability to adjust settings of aggregations of DER with standardized embedded control functionality constitutes a mechanism which can, potentially, create undesirable or deleterious effects on the power grid. The purpose of this white paper is to highlight unintended effects stemming from improperly tuned embedded control functions in Distributed Energy Resources (DER), which could be exploited by a malicious entity as a means to attack the power grid.

14 SOLAR ENERGY↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗