Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A low-cost centralized HVAC control system solution for energy savings, load shedding, and improved maintenance

University campuses rely on centralized controls for managing and optimizing complex HVAC systems in larger buildings. However, most campuses also have many smaller buildings with packaged HVAC systems controlled by a stand-alone thermostat. Even when these distributed and often overlooked systems have modern programmable thermostats, they cannot be centrally monitored or controlled, and they are typically not programmed adequately. This paper describes the implementation of a low-cost centralized control solution for these systems serving smaller campus buildings, mostly under 5,000 sf and representative of light commercial spaces. Thanks to advances in technology spurred by residential and commercial IoT developments, simple networked thermostat solutions exist that can easily replace original thermostats, and, connect these systems to a web-based portal for monitoring and control. We show that, with small customizations, these platforms can be integrated into facility management workflows. Beyond the energy savings potential from improved scheduling and closer management of these systems, there are significant advantages for maintenance crews since these systems can now be monitored on smart phones or tablets. A grid-responsive load-shedding program has also been implemented for additional cost savings. The networked thermostats can also be connected to additional systems such as economizer controls for improved ventilation management and energy savings. With data from these systems integrated centrally, it can also be used for improved analytics and fault detection. A toolkit has been developed to share the program with other campuses, whether for energy savings, improved management of ventilation, or a more proactive maintenance approach.

Fauchier-Magnan, Nicolas↗

Interaction between Heat Pump Water Heaters or Other Internal Point Source Loads and a Central Heating System

Water heating represents approximately 18% of residential energy consumption, or 4.6 quadrillion Btus of source energy use annually (EIA 2009). Heat pump water heaters (HPWHs) offer an efficient option for residential water heating, with the ability to reduce water heating energy consumption by up to 63%. Previous research has demonstrated the laboratory performance of HPWHs and has shown savings of 43 to 62% on water heating energy consumption are possible, based on field tests (Ecotope 2015). In order to achieve such high efficiencies, HPWHs employ a refrigeration cycle to move heat from the ambient air into the water. Therefore, when HPWHs are installed in conditioned space, they will remove heat from that space which can help the HVAC system in the cooling season and require additional energy from the HVAC system in the heating season. This project provides an unbiased evaluation of the space conditioning interactions between a HPWH and the heating system in several locations throughout the home to further our understanding of the impact that HPWHs have on space conditioning loads. This report explores the HPWH interaction factor from several perspectives: (1) a theoretical analysis, (2) a review of previous literature, and (2) an experimental assessment. The experiments were conducted in PNNL’s side-by-side Lab Homes, which provide a platform for evaluating energy-saving and grid-responsive technologies in a controlled environment. The PNNL Lab Homes are two factory-built homes installed on PNNL’s campus in Richland, Washington. The homes represent existing homes, which account for approximately 99% of occupied homes in the U.S. These 1500 ft2 homes have three bedrooms, two bathrooms, and are equipped with 7.7 HSPF heat pump and an electric forced air furnace. Both homes have R-22 floors, R-11 walls and R-22 ceiling insulation levels, with double-pane clear glass windows. The results of this experiment verified that the energy use of the HVAC system increases as a point source cooling load, like a HPWH, is moved closer to the thermostat. The opposite is also true, as a point source heating load is moved closer to the thermostat, the heating load decreases. The results show between 30-40% difference between the interaction that this type of load has when it is placed in the master bathroom compared to the living room for the PNNL Lab Homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deployment of Dynamic Neural Network Optimization to Minimize Heat Rate During Ramping for Coal Power Plants (Final Technical Report)

Much success was achieved throughout the course of this project. A successful implementation of Dynamic Neural Network Optimization (D-NNO) was coupled with Adaptive Predictive Controls (APC) and a novel hardware installation comprised of an advanced sensor network (ASN) measuring mass-weighted averages of flue gas constituents above the horizontal superheater of a coal-fired utility boiler. From 2019 through 2023 (including an extension due to COVID delays), the team was able to prototype, evaluate, deploy, iterate, and ultimately finalize an advanced closed-loop control D-NNO system which demonstrated the ability to: •improve unit efficiency ~2.0% relative to unoptimized operation (represented as total fuel fired per MWh generated) •improve unit NOx emission rates 10%+ beyond static optimization baselines •improve unit temperature stability as much as 58% and on average 12% •improve operating load stability as much as 35% The culmination of this project has generated an advanced methodology of deploying specially designed recurrent neural networks (long short-term memory, gated recurrent unit, encoder-decoder networks, transformers, etc.), customized trajectory planning and closed-loop optimization modules capable of adapting to live electric grid responses and demands, self-tuning and adaptive expert controls constantly adjusting prediction parameters to real-time unit behavior, and a hardware/software package able to reliably calculate net unit heat rate (NUHR) in real-time using flue gas constituents, machine learning, and known combustion relationships. Through this real-time NUHR value, immediate feedback on system adjustments relative to operating efficiency was available, allowing for rapid improvements to system performance. In addition to development and deployment of the advanced D-NNO system, the approach methodology has been readily commercialized through the project platform Griffin Open Systems, LLC, the D-NNO software platform host. Similar methodologies to those developed by this project have already been deployed at 5 other units across the United States, with another 6 implementations scheduled, and more expected. Over the course of the project, multiple academic papers were submitted and accepted for publication within esteemed academic journals, and PhD students were trained and graduated, as well as undergraduate students becoming involved and participating to project objectives.

01 COAL, LIGNITE, AND PEAT↗

Navier-Stokes computations on full-span wing-body configuration with oscillating control surfaces

Unsteady Navier-Stokes simulations have been performed for vortical flows over an 'arrow-wing' configuration of a supersonic transport in the transonic regime. Computed steady pressures and integrated force coefficients with and without control surface deflection at a moderate angle of attack are compared with experiment. For unsteady cases, oscillating trailing-edge control surfaces are modeled by using moving grids. Response characteristics between symmetric and anti-symmetric oscillatory motions of the control surfaces on the left and right wings are studied. The anti-symmetric case produces higher lift than the steady case with no deflection, and the unsteady symmetric case produces higher lift than the anti-symmetric case. The detailed analysis of the wake structure revealed a strong interaction between the primary vortex and the wake vortex sheet from the flap region when the flap is deflected up.

Obayashi, Shigeru↗

Navier-Stokes Computations on Full Wing-Body Configuration with Oscillating Control Surfaces

Unsteady Navier-Stokes simulations have been performed for vortical flows over an "arrow-wing" configuration of a supersonic transport in the transonic regime. Computed steady pressures and integrated force coefficients with and without control surface deflection at a moderate angle of attack are compared with experiment. For unsteady cases, oscillating trailing-edge control surfaces are modeled by using moving grids. Response characteristics between symmetric and antisymmetric oscillatory motions of the control surfaces on the left and right wings are studied. The antisymmetric case produces higher lift than the steady case with no deflection and the unsteady symmetric case produces higher lift than the antisymmetric case. The detailed analysis of the wake structure revealed a strong interaction between the primary vortex and the wake vortex sheet from the flap region when the flap is deflected up.

Obayashi, Shigeru↗

Specificity and Transfer in Learning How to Follow Navigation Instructions

We report a series of experiments that use a navigation task in which instructions for navigating in a space displayed as grids on a computer screen are given to subjects who then attempt to follow them by mouse clicking on the grids. The navigation task was broken down into component dimensions (e.g., presentation mode of the instructions, length of the instructions, characteristics of the display, size of the grids, response type). For each task dimension, one condition was used at training and the same or another condition was used at test. Each task dimension was examined in terms of two measures. One measure provided an index of transfer (i.e., better performance at test than at training when test and training involved different conditions), and the other provided an index of specificity (i.e., better performance at test when training and test conditions were the same than when training and test conditions were different). By and large, these two indices were complementary, so there was evidence of either transfer or specificity but not both. For one dimension transfer but no specificity was evident, and for another dimension specificity but no transfer was evident. For the remaining dimensions, however, there was asymmetrical transfer, with transfer evident for some conditions and specificity evident for others. The findings are interpreted within the procedural reinstatement framework. They have practical implications concerning how to optimize training and how much fidelity to the testing situation is necessary when training.

Healy, Alice F.↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Roles and Responsibilities for Distribution Grids: DER Sensing and Communication Networks

Traditional distribution grids require sensing and communications for grid operations. In many cases the communications networks are owned by the Distribution Operator (DO); in some cases, carrier services such as leased telephone land lines or cellular services are used. In recent years, wireless mesh field area networks and optical fiber have become viable options for distribution. Fiber in particular has improved in cost to the point where its high performance (large bandwidth, low latency, and low packet loss) has become practical for distribution systems where geographic circumstances permit. As grid modernization proceeds, utilities find a need to improve or upgrade distribution communications; this represents a significant investment and it is natural that both utilities and regulators would seek both to future-proof and minimize their costs. Given the development and rising penetration of smart grid edge devices such as Distributed Energy Resources (DER) that have local sensing and intelligence and can communicate via the internet or other non-utility communications channels to cloud-based services, the idea of using such devices for grid sensing and communications to support grid operations has emerged as a potential means to avoid utility investment. To a great extent, however, these DER and communication channels will be owned and operated not by the DO but by end-use customers, aggregators and other third parties pursuing their own energy needs and business models. The question of whether such devices and systems can effectively substitute for DO grid modernization investment can be assessed and resolved using grid architecture methods and by considering the appropriate roles and responsibilities of the entities and systems involved in distribution grid operations. This approach reveals that there are several compelling reasons to dismiss the idea of eliminating DO owned and operated sensing and communication entirely and relying on DER-based sensing and third party communications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

Efficient Customer Selection for Sustainable Demand Response in Smart Grids

Regulating the power consumption to avoid peaks in demand is a common practice. Demand Response(DR) is being used by utility providers to minimize costs or ensure system reliability. Although it has been used extensively there is a shortage of solutions dealing with dynamic DR. Past attempts focus on minimizing the load demand without considering the sustainability of the reduced energy. In this paper an efficient algorithm is presented which solves the problem of dynamic DR scheduling. Data from the USC campus micro grid were used to evaluate the efficiency as well as the robustness of the proposed solution. The targeted energy reduction is achieved with a maximum average approximation error of ≈ 0.7%. Sustainability of the reduced energy is achieved with respect to the optimal available solution providing a maximum average error less than 0.6%. It is also shown that a solution is provided with a low computational cost fulfilling the requirements of dynamic DR.

change making↗

Intelligent industrial demand response to increase grid flexibility and reliability: A review

The rapid transition toward renewable energy has introduced challenges in grid stability due to the intermittency of non-dispatchable sources like solar and wind. Industrial Demand Response (IDR) offers a promising, cost-effective solution that adjusts energy consumption patterns to align with supply, increases renewable utilization, and reduces costs. This review provides an updated analysis of IDR, sorting technologies into five categories: energy storage, scheduled energy usage, operational flexibility, on-site generation, and intelligent operations. Energy storage solutions, while requiring little flexibility, often have the longest payback periods. While slightly better, on-site generation also has longer payback periods, ranging from 5 to 20 years or more. Scheduled energy usage, operational flexibility, and intelligent operations allow significant peak reduction at lower capital costs but require greater flexibility. While 15–20 % peak reduction is within the range of all five categories, scheduled energy use and on-site energy generation are shown to have reductions of up to 70–80 % in select scenarios. Combining multiple IDR strategies from these five categories maximizes both financial and operational benefits. Synergistic approaches are shown to enhance grid stability while reducing costs. As the grid evolves, IDR will enable a more flexible, renewable-powered future that will benefit industrial facilities and the broader energy system.

Demand flexibility↗

Hardware-in-the-Loop Co-simulation of Distribution Grid for Demand Response

In modern power systems, co-simulation is proposed as an enabler for analyzing the interactions between disparate systems. This paper introduces the co-simulation platform Virtual Grid Integration Laboratory (VirGIL) including Hardware-in-the-Loop testing, and demonstrates its potential to assess demand response strategies. VirGIL is based on a modular architecture using the Functional Mock-up Interface industrial standard to integrate new simulators. VirGIL combines state-of-the-art simulators in power systems, communications, buildings, and control. In this work, VirGIL is extended with a Hardware-in-the-Loop component to control the ventilation system of a real 12-story building in Denmark. VirGIL capabilities are illustrated in three scenarios: load following, primary reserves and load following aggregation. Experimental results show that the system can track one minute changing signals and it can provide primary reserves for up-regulation. Furthermore, the potential of aggregating several ventilation systems is evaluated considering the impact at distribution grid level and the communications protocol effect.

Rotger-Griful, Sergi↗

Modeling the Interaction Between Energy Efficiency and Demand Response on Regional Grid Scales: Preprint

With increasing penetration of intermittent renewable generation at grid and distributed scales, flexible building loads can provide significant system value and support the evolving needs of the grid. The growing value of load flexibility may complicate the traditional separation between energy efficiency (EE) and demand response (DR). EE measures may compete in some cases with a building’s DR capabilities but complement one another in other cases. EE can also increase or decrease the need for DR at the system level and change the availability of DR to meet system needs. In this study we present a bottom-up approach to modeling interactive effects between EE and DR in buildings within two regions of the US electricity grid. From a library of building simulation models for different buildings and climates, we synthesize system-level demand profiles and the impacts of potential future EE portfolios. Coupling the underlying building models with a database of DR-enabling technologies, we then compute the quantity of DR that can be delivered in each scenario. The results show that EE and DR interactions are largely driven by the timing of EE savings that are measure-specific and the coincidence with system peak demand that is region-specific. We also find that perspective of the impacts matters – for instance that some EE measures reduce the system need for DR but also reduce the DR potential. Our results imply that utility EE and DR programs developed without considering interactive effects may lead to increased grid-management challenges over the long term.

buildings↗

An Analysis of Grid Operator Survey Responses: Inexperience, Workload and Fatigue in the Control Room

Although a wide array of tools and technologies have been developed over the last decade to support power grid operators, deployment of these tools has been less successful. One reason for unsuccessful deployment may be an inadequate understanding of the factors that contribute to operator error in the control room. An analysis of operators’ current vulnerabilities may provide the baseline understanding needed to inform new technology integration. In an attempt to learn more about these vulnerabilities and their perceived impact on human error we collected and analyzed survey data from 20 electric grid control room operators. We asked survey respondents to consider the various operator, technology and interaction vulnerabilities that may arise during work in the control room and record their attitudes and experiences toward each. Results suggest operator inexperience, high mental workload and fatigue are the most common vulnerabilities experienced during a shift. Survey results were analyzed to explore these vulnerabilities in greater depth.

Inexperience, Workload, Fatigue↗