Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid-interactive efficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Efficiency and Demand Flexibility in Large Office Buildings

Data is associated with Report "Efficiency and Demand Flexibility in Large Office Buildings" by Joyce McLaren, Thomas Bowen, and Chioke Harris ( https://doi.org/10.2172/1989231 ). Results are created from repos GEB_ECM_Impact_Estimator ( https://github.nlr.gov/tbowen/GEB_ECM_Impact_Estimator ). Results outline the changes in building load in large office buildings based on measures from NREL's Scout, and the impacts those changes in load have on grid-induced emissions, grid operating costs, and customer bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Terrestrial photovoltaic collector technology trends

Following the path of space PV collector development in its early stages, terrestrial PV technologies based upon single-crystal silicon have matured rapidly. Currently, terrestrial PV cells with efficiencies approaching space cell efficiencies are being fabricated into modules at a fraction of the space PV module cost. New materials, including CuInSe2 and amorphous silicon, are being developed for lowering the cost, and multijunction materials for achieving higher efficiency. Large grid-interactive, tracking flat-plate power systems and concentrator PV systems totaling about 10 MW, are already in operation. Collector technology development both flat-plate and concentrator, will continue under an extensive government and private industry partnership.

Shimada, K.↗

Alfalfa Virtual Building Service: Software Engineering Best Practices Applied to Runtime Interaction with Building Energy Models

Buildings are active participants in increasingly complex energy systems. Building Energy Modeling (BEM) has a key role to play in planning and de-risking an equitable energy transition, with BEM-backed "virtual buildings" critical path for diverse applications that include workforce training tools, Hardware-in-the-Loop (HIL) experimentation to study equipment performance under a range of conditions, Control-Hardware-in-the-Loop (CHIL) experimentation to de-risk commercial control implementations at equipment through grid orchestration levels, and integration of dynamic load profiles into grid modeling tools for energy system experimentation at the urban scale. Modeling requirements vary across these applications, but many software engineering tasks do not. The Alfalfa Virtual Building Service (AVBS, see https://github.com/NREL/alfalfa/wiki) is an open-source web service that solves these common tasks robustly in one place, providing a foundational platform for power users to bootstrap their own applications. AVBS abstracts the specifics of runtime interaction with OpenStudio, Modelica, and Spawn of EnergyPlus models behind a unified REST API. Additionally, AVBS provides resources for cloud deployment and scaling to 100s of parallel simulations, a growing library of modular Operational Technology (OT) integrations for emulation of real-world interfaces, and scripts to automate the population of communities of virtual buildings from URBANopt, ResStock and ComStock.

building automation↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Graduating Sustainable Industrial Decarbonization Solutions from the Laboratory to Real-World Deployments

Accelerating innovation and integration of industrial decarbonization technology solutions is crucial for achieving industry-wide net-zero greenhouse gas emissions targets. This can be accomplished in various ways through increased utilization of low-embodied carbon materials and the adoption of advanced manufacturing techniques in construction practices. At the National Renewable Energy Laboratory (NREL), we facilitate dialogue and action across all sectors to uncover industry needs to inform innovation, and explore ways we can help with implementation of emerging solutions in the real world. As an applied laboratory, NREL sits between academia and industry to fully bridge the gap from foundational science research to examining the feasibility of market applications. Integration of innovative technologies and solutions that are efficient, resilient, and grid-interactive will play a pivotal role in supporting a clean energy future. However, it is imperative that these solutions prioritize equitable outcomes, addressing the challenges faced by all communities. By embracing decarbonization, the construction industry can revolutionize itself, promoting sustainability, reducing carbon emissions, conserving resources, while enhancing performance and durability - all major steps toward a greener and more sustainable future.

cement↗

Practical challenges of model predictive control (MPC) for grid interactive small and medium commercial buildings

To the urgent call for mitigating climate change, substantial initiatives have been undertaken to deploy grid-interactive heating, ventilation, and air-conditioning (HVAC) controls, such as model predictive control (MPC) for buildings. These efforts typically aim to curtail peak energy demand, shift load and enhance overall energy efficiency. With the recent development of low-cost MPC technologies that don’t require extensive instrumentation or manual modeling, small and medium commercial buildings (SMCBs), which rarely utilize advanced HVAC control systems, have become candidates for grid-interactive efficient buildings (GEBs). However, despite the potential benefits and maturity of the technology itself, several practical challenges remain in real-world implementation. In this paper, we share the practical challenges that we have encountered in implementing and testing three types of MPC solutions (ON/OFF unit, dualfuel, and VRF systems) on multiple SMCB sites. We describe the MPC deployment process and discuss the lessons learned. The site selection, eligibility, and retrofit availability (e.g., utility price structure, thermostat communications, etc.) are the main discussion points at the beginning of the project. Also, the modeling automation and the best practices for interacting with endusers and handling erroneous situations are presented for successful operations.

woo Ham, Sang↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Global-Local Policy Search and its Application in Grid-Interactive Building Control

As the buildings sector represents over 70% of the total U.S. electricity consumption, it offers a great amount of untapped demand-side resources to tackle many critical grid-side problems and improve the overall energy system's efficiency. To help make buildings grid-interactive, this paper proposes a global-local policy search method to train a reinforcement learning (RL) based controller which optimizes building operation during both normal hours and demand response (DR) events. Experiments on a simulated five-zone commercial building demonstrate that by adding a local fine-tuning stage to the evolution strategy policy training process, the control costs can be further reduced by 7.55% in unseen testing scenarios. Baseline comparison also indicates that the learned RL controller outperforms a pragmatic linear model predictive controller (MPC), while not requiring intensive online computation.

demand response↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

Carl T. Hayden Veterans Affairs Medical Center: Smart Buildings Case Study

The purpose of this smart buildings case study is to showcase a leading example of a GEB renovation project in the federal buildings space and provide key information on the technology and control upgrades, costs, and energy and utility bill savings. This case study also provides information and recommendations for selecting energy conservation measures (ECMs) and choosing energy and cost reduction strategies from the energy management team at the site. The findings from this successful GEB project can be used to help pave the way for additional GEB retrofits in the future. The Carl T. Hayden Veterans Affairs (VA) Medical Center in Phoenix, Arizona, demonstrates that GEB strategies and technologies can be realistically deployed today across buildings with substantial energy and cost savings. The project implemented both ECMs and grid-interactive technologies and controls strategies, making it a leading example of a smart, sustainable, and efficient commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Fighting the climate crisis with caloric heat pumping: Innovations to enable widespread adoption

Caloric heat pumping is a cross-cutting thermal energy technology that can cover a wide range of applications and temperatures, from millikelvins to hundreds of kelvins, with a working medium that has zero global warming potential. The technology promises cost savings and high efficiency, having 60% Carnot efficiency demonstrated to date. The Energy Earthshots™ Initiative, launched by the U.S. Department of Energy, aims to fight the climate crisis and overcome technological barriers to a decarbonized economy. The initiative focuses on the development of energy solutions that increase efficiency, reduce greenhouse gas emissions, and ensure affordability. Three out of eight Energy Earthshots™ look for alternative thermal energy technologies for extensive temperature ranges, from hydrogen liquefaction to metal-treating temperatures. Caloric heat pumping can fulfill all these requirements; however, at the current stage, caloric systems have limited presence in real-world applications. Further, this perspective discusses key efforts to address barriers hindering the widespread adoption of caloric technology. We focus on essential breakthroughs in and effective approaches to material discovery and draw a path to high-power-density, grid-interactive caloric systems to support achieving the ambitious net-zero carbon economy goal.

42 ENGINEERING↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BOPTest As a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BOPTEST as a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗