Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat of vaporization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Determination of bulk properties of tropical cloud clusters from large scale heat and moisture budgets, appendix B

The bulk properties of tropical cloud clusters, as the vertical mass flux, the excess temperature, and moisture and the liquid water content of the clouds, are determined from a combination of the observed large-scale heat and moisture budgets over an area covering the cloud cluster, and a model of a cumulus ensemble which exchanges mass, heat, vapor and liquid water with the environment through entrainment and detrainment. The method also provides an understanding of how the environmental air is heated and moistened by the cumulus convection. An estimate of the average cloud cluster properties and the heat and moisture balance of the environment, obtained from 1956 Marshall Islands data, is presented.

Yanai, M.↗

Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (LCO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas is a significant heat transfer mechanism for the warming of the adsorbent bed because it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously. A NASA Small Business Innovative Research (SBIR) Phase 1 contract was performed to investigate condensing and icing as applied to MTSA to enable higher fidelity modeling and assess the impact of geometry variables on CIHX performance for future CIHX design optimization. Specifically, a design tool was created using analytical relations to explore the complex, interdependent design space of a condensing ice heat exchanger. Numerous variables were identified as having nontrivial contributions to performance such as hydraulic diameter, heat exchanger effectiveness, ventilation gas mass flow rate and surface roughness. Using this tool, four test articles were designed and manufactured to map to a full MTSA subassembly (the adsorbent bed, the sublimation heat exchanger for cooling and the condensing ice heat exchanger for warming). The design mapping considered impacts due to CIHX geometry as well as subassembly impacts such as thermal mass and thermal resistance through the adsorbent bed. The test articles were tested at simulated PLSS ventilation loop temperature, moisture content and subambient pressure. Ice accumulation and melting were observed. Data and test observations were analyzed to identify drivers of the condensing ice heat exchanger performance. This paper will discuss the analytical models, the test article designs, and testing procedures. Testing issues will be discussed to better describe data and share lessons learned. Data analysis and subsequent conclusions will be presented.

Padilla, Sebastian↗

Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2-selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (L CO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas represents a significant source of potential energy for the warming of the adsorbent bed as it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously.

Padilla, Sebastian↗

Vapor Compression and Thermoelectric Heat Pump Heat Exchangers for a Condensate Distillation System: Design and Experiment

Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.

Erickson, Lisa R.↗

Turbulent heat and mass transfers across a thermally stratified air-water interface

Rates of heat and mass transfer across an air-water interface were measured in a wind-wave research facility, under various wind and thermal stability conditions (unless otherwise noted, mass refers to water vapor). Heat fluxes were obtained from both the eddy correlation and the profile method, under unstable, neutral, and stable conditions. Mass fluxes were obtained only under unstable stratification from the profile and global method. Under unstable conditions the turbulent Prandtl and Schmidt numbers remain fairly constant and equal to 0.74, whereas the rate of mass transfer varies linearly with bulk Richardson number. Under stable conditions the turbulent Prandtl number rises steadily to a value of 1.4 for a bulk Richardson number of about 0.016. Results of heat and mass transfer, expressed in the form of bulk aerodynamic coefficients with friction velocity as a parameter, are also compared with field data.

Papadimitrakis, Y. A.↗

The Planck Sorption Cooler: Using Metal Hydrides to Produce 20 K

The Jet Propulsion Laboratory has built and delivered two continuous closed cycle hydrogen Joule-Thomson (JT) cryocoolers for the ESA Planck mission, which will measure the anisotropy in the cosmic microwave background. The metal hydride compressor consists of six sorbent beds containing LaNi4.78Sn0.22 alloy and a low pressure storage bed of the same material. Each sorbent bed contains a separate gas-gap heat switch that couples or isolates the bed with radiators during the compressor operating cycle. ZrNiHx hydride is used in this heat switch. The Planck compressor produces hydrogen gas at a pressure of 48 Bar by heating the hydride to approx.450 K. This gas passes through a cryogenic cold end consisting of a tube-in-tube heat exchanger, three pre-cooling stages to bring the gas to nominally 52 K, a JT value to expand the gas into the two-phase regime at approx.20 K, and two liquid - vapor heat exchangers that must remove 190 and 646 mW of heat respectively.

hydrogen storage materials↗

Preliminary Results of an Experimental Investigation of the Qu Superconducting Heat Pipe

This note on preliminary results of our evaluation of the so-called Qu Tube is prompted in part by recent concerns expressed to the authors by some researchers regarding the performance characteristics of the superconducting, solid-state heat pipe as described in the patents, or on the company's websites. Briefly, the company's claims include: a new type of heat transfer mechanism that is a form of solid state thermal superconductivity, which results in an effective thermal conductivity of the order of tens of thousands of times that of an equivalent solid silver bar, or, tens to hundreds of times that of liquid - vapor heat pipes. The company's website also refers to tests conducted by Stanford Research Institute that substantiate these claims, but the report is apparently not publicly available. We are conducting an investigation of the Qu Tube under a NASA Grant, and in general find that these claims have merit, but our study is not yet complete. We present some of our preliminary results in part to show that it would not be imprudent to conduct such studies, especially for possible future applications requiring exceptional thermal management performance capabilities. Working with HiTek Services, we originally acquired several Qu Tubes, including 17" long, 5/16" diameter copper tubes, one that is 7 7/8" long, 3/16" diameter, and one that is 4" long, 1" diameter. We subjected the smaller tubes to various exploratory tests, including a transient test with electrical band heaters, boiling water tests, and a series of steady state tests with electrical band heaters heating one end with free convective cooling along the remainder of the length. All results indicate a very high thermal conductivity, but the length of these tubes limited our ability to obtain accurate data on temperature gradients, necessary to determine the effective thermal conductivity. We then acquired nine Qu Tubes that are 10' long, 5/16" diameter, and we have recently conducted initial tests, which further support the claims of exceptional thermal conductivity.

Blackmon, James B.↗

Vapor concentration measurement with photothermal deflectometry

Theoretical and experimental results for using the photothermal deflection technique to measure vapor species concentration, while minimizing the disturbance of the transport (material) parameters due to vapor heating, are developed and described. In contrast to common practice, the above constraints require using a pump-beam duty cycle of less than 50 percent. The theoretical description of the shortened heating time is based on a step-function formulation of the pumping cycle. The results are obtained as closed-form solutions of the energy equation for many chopping cycles until steady state is reached, by use of a Green's-function method. The Euler formulation of the Fermat principle is used to calculate the deflection angle. The equations are expanded to include the effects of vapor velocity on both the temperature and temperature gradient profiles. The effects of finite (unfocused) pump and probe beams and thermal (Soret) diffusion are also accounted for. Excellent agreement between theory and experiment is obtained.

Banish, R. Michael↗

Aerosol Chemical Speciation Monitor (ACSM) Composition-Dependent Collection Efficiency (CDCE) Value-Added Product Report

Aerosol particles influence the Earth’s radiation balance directly by absorbing and scattering light and indirectly by influencing cloud formation, properties, and lifetimes. Measurements of aerosol particle optical properties, mass loading, size distributions, microphysical properties, cloud formation properties, and chemical composition are important for understanding the aerosol life cycle and for validating earth system models that predict these quantities. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Aerosol Observing System (AOS) is a highly instrumented platform that measures many of these aerosol properties in situ. The Aerodyne aerosol chemical speciation monitor (ACSM) is a baseline instrument deployed in the AOS. The ACSM provides a quantitative measurement of aerosol particle chemical composition for non-refractory (operationally defined as components that evaporate on the 600ºC vaporizer) aerosol components in real time. Standard output is the mass concentration of particulate organics, nitrate, sulfate, chloride, and ammonium. One well-known limitation to the accuracy of the ACSM data is in evaluating the fraction of the ambient aerosol particles that are detected by the instrument. This quantity is referred to as the collection efficiency (CE) and is often less than unity. This is attributed to particles rebounding after impaction onto the heated vaporizer rather than being trapped, volatilized rapidly, and detected. Other factors, such as divergence of the aerosol particle beam, may also impact CE, but the particle rebound effect is the dominant factor. Scientists will sometimes assume CE = 0.5 (i.e., one half of sampled particles are detected) for ambient particles collected during field missions. However, parameterizations have been developed that express CE as a function of the measured chemical composition, referred to as the composition-dependent collection efficiency (CDCE). The physical explanation for a CDCE, supported by laboratory studies, is that rebound from the vaporizer is a function of the particle phase, with liquid-like particles “sticking” to the vaporizer and solid-like or crystalline particles “bouncing” from the vaporizer. Thus, particles with compositions are liquids-like under the measurement conditions (e.g., certain organics, acidic particles, particles enriched in nitrate) have CE close to unity while crystalline or solid particles (e.g., deliquesced ammonium sulfate) have lower CE. This value-added product (VAP) implements the procedure described by Middlebrook et al. (2012) to correct the ACSM data for the composition-dependent collection efficiency. Applying this parameterization improves the accuracy of the ACSM data and brings them into better agreement with other co-located aerosol measurements.

54 ENVIRONMENTAL SCIENCES↗

Near-surface ice on Mercury and the Moon: A topographic thermal model

A thermal model that can be easily adapted to craters of arbitrary shape is developed and applied to high-latitude impact craters on Mercury and the Moon, Chao Meng Fu crater at -87.5 deg L on Mercury, an unnamed bowl-shaped crater at 86.7 deg L on Mercury, and Peary crater at 88.6 deg L on the Moon. For an assumed input topography and grid of surface elements, the model computes for each element the irradiation from direct insolation and reflected and emitted radiation from other elements, taking into account shadowing by walls of the crater, partial obscuration of the solar disk near the poles and the diurnal, orbital, and seasonal cycles. Temperatures are computed over the surface grid as functions of depth and time from the surface to a specified depth and over the pertinent astronomical cycles, including the effects of direct and indirect surface irradiation, infrared radiation, heat conduction, and interior heating. Vapor fluxes and ice recession times are computed as functions of ice depth over the surface grid. Temperatures profiles, vapor fluxes, and ice recession times were computed for flat surfaces not associated with craters near the poles of Mercury and the Moon. It was found that water ice could have existed throughout geologic time within the maximum radar detection depth of recent observation of Mercury (J. K. Harmon and M. A. Slade, 1992, Science 258, 640-643) poleward of approximately 87 - 88 deg L on Mercury and poleward of approximately 73 deg L on the Moon. For Chao Meng Fu crater it was found that approximately 40% of the crater floor is permanently shadowed from direct solar insolation, while the remainder of the crater floor is periodically illuminated by a partially obscured Sun. Temperatures at the upper levels of the south wall can slightly exceed 550 K. Surface temperatures in the permanently shadowed region of the crater floor are under approximately 130 K, which could have allowed water ice to exist throughout geologic time within the radar detection depth of recent observation of Mercury. For small bowl-shaped crater on Mercury, it was found that most of the crater is permanently shadowed from direct solar radiation, except for a narrow semicircular band bordering the north rim. However, temperatures in the permanently shadowed region periodically reach a maximum near approximately 315 K due to efficient heating of the small crater by thermal emission and reflection from the small sunlit region, which periodically reaches temperatures exceeding 630 K. Water ice could not have existed throughout geologic time anywhere in this crater within the radar detection depth. For Peary crater on the Moon, the entire crater floor is permanently shadowed from direct solar insolation with maximum temperature under 120 K. The upper level of the north wall periodically reaches a maximum temperature near 310 K. The low temperatures on the crater floor would have allowed water ice to exist near the surface throughout geologic time, provided that the Moon's obliquity was always as low as it is at present.

Salvail, James R.↗

Bench Scale Heat Pipe and Vapor Chamber Testing for Space Applications

NASA’s space missions demand better and more efficient carbon dioxide removal systems. wo challenges present themselves in improving the state of the art pellet adsorption beds: power minimization and uniform heating for carbon dioxide desorption. Titanium heat pipes and vapor chambers were found to be excellent candidates in solving these problems because of their passive heating nature, tolerance to high temperatures, and capability of direct implementation into these adsorbent beds.This research work compares these different titanium heat pipes (HPs) and vapor chambers (VPs).

MultiSORB↗

High Energy Arcing Fault (HEAF): Sandia National Laboratories 2023 Report

High Energy Arcing Faults (HEAFs) are hazardous events in which an electrical arc leads to the rapid release of energy in the form of heat, vaporized metal, and mechanical force. In Nuclear Power Plants (NPPs), these events are often accompanied by loss of essential power and complicated shutdowns. To confirm the probabilistic risk analysis (PRA) methodology in NUREG/CR-6850, which was formulated based on limited observational data, the NRC led an international experimental campaign from 2014 to 2016. The results of these experiments uncovered an unexpected hazard posed by aluminum components in or near electrical equipment and the potential for unanalyzed equipment failures. Sandia National Laboratories (SNL), in support of the NRC work, collaborated with NIST, BSI, KEMA, and NRC to support the full-scale HEAF test campaign in 2023. SNL provided high speed and real time from visible and infrared video/data of tests that collected data from copper and aluminum busses from switchgears and bus-ducts. Part of SNL work was to place cameras with high-speed data collection capability at different vantage points that provide the NRC a more complete and granular view of the test events.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Energy Arcing Fault (HEAF) Photometrics 2022 Test Report

High Energy Arcing Faults (HEAFs) are hazardous events in which an electrical arc leads to the rapid release of energy in the form of heat, vaporized metal, and mechanical force. In Nuclear Power Plants, these events are often accompanied by loss of essential power and complicated shutdowns. To confirm the probabilistic risk analysis (PRA) methodology in NUREG/CR-6850, which was formulated based on limited observational data, the NRC led an international experimental campaign from 2014 to 2016. The results of these experiments uncovered an unexpected hazard posed by aluminum components in or near electrical equipment and the potential for unanalyzed equipment failures. Sandia National Laboratories (SNL), in support of the NRC work, collaborated with NIST, BSI, KEMA, and NRC to support the full-scale HEAF test campaign in 2022. SNL provided high speed visible and infrared video/data of ten tests that collected data from HEAFs originated on copper and aluminum buses inside switchgears and bus ducts. Part of the SNL scope was to place cameras with high-speed data collection at different vantage points within the test facility to provide NRC a more complete and granular view of the test events.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Guidance and control research

Cesium vapor heat conduction in thermionic energy converters, space charge distribution in neutral plasma, and titanium oxide thin films

THERMIONIC CONVERTER↗

An overview of UK C130 observations from the FIRE marine stratocumulus IFO

An overview of the characteristics of the ten flights made by the C130 during the Intensive Field Observations (IFO) are presented. An indication of data quality is given. Comparisons of the carbon dioxide radiation thermometer and the Rosemount suggest there may be potentially serious wetting problems with the latter, especially close to cloud base. The main features of the cloud layers sampled by the C130 are summarized, including microphysical parameters. Many of the results shown are derived from a first order analysis of turbulence quantities. The gross vertical variation of heat, vapor, and liquid water fluxes from case to case, together with the observed vertical velocity variance, a good indicator of convective activity, are discussed. Preliminary results suggest that the different cases can be usefully categorized using these data. The relationship between these and the measured boundary conditions is mentioned. Similarities and differences between the various cases are highlighted, and interpreted in terms of the researchers' current understanding of stratocumulus. Attention is given to particular features of the various flights which may deserve more intensive study.

Nicholls, S.↗

Effect of stabilizing forces on turbulence

The appearance of expressed discontinuity layers in the free atmosphere, where a warm air mass flows over a cold mass without perceptible intermingling forms the basis of the present report. In these experiments an air stream is to be blown between a water-cooled and a vapor-heated plate. According to what preceded it is anticipated that the exchange will be enhanced. Because these experiments had to be made at relatively low air speeds so as to let the lifting forces become effective, it first required a study of the test methods, and so we have not yet proceeded beyond the preliminary tests on the most suitable hot-wire connections and thermocouples for recording speed and temperature.

PRANDTL L↗