Search NASASearch

SEARCH · Search NASA

Results for “heat ratio method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

526 records · Page 4

Determining Stellar Elemental Abundances from DESI Spectra with the Data-driven Payne

Abstract Stellar abundances for a large number of stars provide key information for the study of Galactic formation history. Large spectroscopic surveys such as the Dark Energy Spectroscopic Instrument (DESI) and LAMOST take median-to-low-resolution (R≲ 5000) spectra in the full optical wavelength range for millions of stars. However, the line-blending effect in these spectra causes great challenges for elemental abundance determination. Here we employDD-Payne, a data-driven method regularized by differential spectra from stellar physical models, to the DESI early data release spectra for stellar abundance determination. Our implementation delivers 15 labels, including effective temperatureT eff , surface gravity log g , microturbulence velocityv mic , and the abundances for 12 individual elements, namely C, N, O, Mg, Al, Si, Ca, Ti, Cr, Mn, Fe, and Ni. Given a spectral signal-to-noise ratio of 100 per pixel, the internal precisions of the label estimates are about 20 K forT eff , 0.05 dex for log g , and 0.05 dex for most elemental abundances. These results agree with the theoretical limits from the Crámer–Rao bound calculation within a factor of 2. The majority of the accreted halo stars contributed by the Gaia–Enceladus–Sausage are discernible from the disk and in situ halo populations in the resultant [Mg/Fe]–[Fe/H] and [Al/Fe]–[Fe/H] abundance spaces. We also provide distance and orbital parameters for the sample stars, which spread over a distance out to ∼100 kpc. The DESI sample has a significantly higher fraction of distant (or metal-poor) stars than the other existing spectroscopic surveys, making it a powerful data set for studying the Galactic outskirts. The catalog is publicly available.

Astronomy & Astrophysics

Machine Learning for Predicting Multipactor Susceptibility in Planar RF Structures

Multipactor discharge is a persistent challenge in high-power microwave (HPM) and accelerator systems, where secondary electron avalanches can cause heating, vacuum degradation, and failure. This work presents the first supervised machine learning (ML) framework for multipactor prediction, trained on high-fidelity 3D Particle-in-Cell (PIC) simulation data in planar geometries. The model maps operational, geometric, and material-dependent secondary electron yield (SEY) parameters to the time-averaged electron growth rate, enabling rapid reconstruction of susceptibility charts. Among the models evaluated, tree-based ensemble methods such as Random Forest and Extra Trees demonstrate superior generalization to unseen materials compared to neural networks such as multilayer perceptron (MLP). Performance metrics, including Intersection over Union (IoU), Structural Similarity Index Measure (SSIM), and Pearson correlation, show close agreement with simulation benchmarks. Principal Component Analysis attributes generalization limits to material feature-space disjointedness.

43 PARTICLE ACCELERATORS

Bypass heat exchanger configuration to reroute core flow

A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.

Terwilliger, Neil

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration With Methane–Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible premixing tube allowing the optical diagnostics. The testing was conducted for varied premixer velocities (V) and equivalence ratio (ϕ) for 90–100% (H 2 , by mole) H 2 /CH 4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior, where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* submechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic

Upper ocean mixing, surface heat fluxes, and heat content variability in the upper 150 m during Hurricane Laura (2020)

Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.

Tsai, Senam

Salt to Metal to Salt Heat Transfer in Narrow Fuel Pins (Final CRADA Report)

This work focused on improving the understanding and modeling of conjugate heat transfer in the Stable Salt Reactor (SSR), particularly the transfer of heat from molten fuel salt inside narrow fuel pins, through the metal cladding and into the surrounding coolant salt.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Establishing accretion flares from supermassive black holes as a source of high-energy neutrinos

ABSTRACT The origin of cosmic high-energy neutrinos remains largely unexplained. For high-energy neutrino alerts from IceCube, a coincidence with time-variable emission has been seen for three different types of accreting black holes: (1) a gamma-ray flare from a blazar (TXS 0506+056), (2) an optical transient following a stellar tidal disruption event (TDE; AT2019dsg), and (3) an optical outburst from an active galactic nucleus (AGN; AT2019fdr). For the latter two sources, infrared follow-up observations revealed a powerful reverberation signal due to dust heated by the flare. This discovery motivates a systematic study of neutrino emission from all supermassive black hole with similar dust echoes. Because dust reprocessing is agnostic to the origin of the outburst, our work unifies TDEs and high-amplitude flares from AGN into a population that we dub accretion flares. Besides the two known events, we uncover a third flare that is coincident with a PeV-scale neutrino (AT2019aalc). Based solely on the optical and infrared properties, we estimate a significance of 3.6σ for this association of high-energy neutrinos with three accretion flares. Our results imply that at least ∼10 per cent of the IceCube high-energy neutrino alerts could be due to accretion flares. This is surprising because the sum of the fluence of these flares is at least three orders of magnitude lower compared to the total fluence of normal AGN. It thus appears that the efficiency of high-energy neutrino production in accretion flares is increased compared to non-flaring AGN. We speculate that this can be explained by the high Eddington ratio of the flares.

Astronomy & Astrophysics

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Systematic Construction of Time-Dependent Hamiltonians for Microwave-Driven Josephson Circuits

Time-dependent electromagnetic drives are fundamental for controlling complex quantum systems, including superconducting Josephson circuits. In these devices, accurate time-dependent Hamiltonian models are imperative for predicting their dynamics and designing high-fidelity quantum operations. Existing numerical methods, such as black-box quantization (BBQ) and energy-participation ratio (EPR), excel at modeling the static Hamiltonians of Josephson circuits. However, these techniques do not fully capture the behavior of driven circuits stimulated by external microwave drives, nor do they include a generalized approach to account for the inevitable noise and dissipation that enter through microwave ports. Here, we introduce numerical techniques that leverage classical microwave simulations, efficiently executable in finite-element solvers, to obtain the time-dependent Hamiltonian of microwave-driven superconducting circuits with arbitrary geometries under charge, flux, or mixed electromagnetic modulation. Importantly, our techniques do not rely on a lumped-element description of the superconducting circuit, in contrast to previous approaches to tackling this problem. We demonstrate the versatility of our approach by characterizing the driven properties of realistic circuit devices in complex electromagnetic environments, including coherent dynamics due to charge and flux modulation, as well as drive-induced relaxation and dephasing. Our techniques offer a powerful toolbox for optimizing circuit designs and advancing practical applications in superconducting quantum computing.

Lu, Yao [Yale U.; Yale U. (main); Fermilab] (ORCID

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]