Search NASA⌕ Search

SEARCH · Search NASA

Results for “heavy ion beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Accelerator Tests of the KLEM Prototypes

The Kinematic Lightweight Energy Meter (KLEM) device is planned for direct measurement of the elemental energy spectra of high-energy (10(exp 11)-10(exp 16) eV) cosmic rays. The first KLEM prototype has been tested at CERN with 180 GeV pion beam in 2001. A modified KLEM prototype will be tested in proton and heavy ion beams to give more experimental data on energy resolution and charge resolution with KLEM method. The first test results are presented and compared with simulations.

Bashindzhagyan, G.↗

Extraction of ion beam from laser ion source for direct plasma injection scheme

Laser ion sources are expected to be used in various applications of heavy ion beam technology. The plasma direct injection scheme (DPIS) is a method in which ion beams extracted from a laser ion source are directly injected into a radio frequency quadrupole (RFQ) linear accelerator. In this study, a new shape of the plasma electrode with a concave surface for the DPIS was proposed to inject a converging beam to a cavity of RFQ accelerator. This approach allows the use of a large-diameter extraction electrode, which is not limited by the aperture of the RFQ electrode rods. The DPIS, using the concave surface electrode, was employed to accelerate C 6+ ion beams. The results indicated that both the beam current and the number of ions increased nearly twice with the proposed electrode shape compared to values obtained with the conventional electrode. This enhancement corresponded to the increased extraction area of the beam.

43 PARTICLE ACCELERATORS↗

Commissioning of the Advanced Rare Isotope Separator ARIS at FRIB

The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) consists of a newly constructed linear accelerator and fragment separator that are designed for enhanced production rates of rare isotopes for use in research and other societal applications. Recent activities through to August 2022 took place to commission the Advanced Rare Isotope Separator (ARIS) and carry out the first experiments. This followed commissioning of the newly constructed linac that is designed to provide orders of magnitude higher beam power than the previously coupled cyclotrons. This required that more advanced target, beam dump, and collimation systems of the new separator be designed and constructed to sustain unprecedented conditions by heavy ion beams. Commissioning with ~1 kW beams began recently and results from activities that began in late 2021 are reported here. Comparisons between the previous and current facilities are provided.

43 PARTICLE ACCELERATORS↗

The fragmentation of 670A MeV neon-20 as a function of depth in water. I. Experiment

We present the final analysis of an experiment to study the interaction of a beam of 670A MeV neon ions incident on a water column set to different thicknesses. The atomic number Z (and, in some cases, the isotopic mass A) of primary beam particles and of the products of nuclear interactions emerging from the water column close to the central axis of the beam was obtained for nuclei between Be (Z = 4) and Ne (Z = 10) using a time-of-flight telescope to measure the velocity and a set of silicon detectors to measure the energy loss of each particle. The fluence of particles of a given charge was obtained and normalized to the incident beam intensity. Corrections were made for accidental coincidences between multiple particles triggering the TOF telescope and for interactions in the detector. The background due to beam particles interacting in beam line elements upstream of the detector was calculated. Sources of experimental artifacts and background in particle identification experiments designed to characterize heavy ion beams for radiobiological research are summarized, and some of the difficulties inherent in this work are discussed. Complete tables of absolutely normalized fluence spectra as a function of LET are included for reference purposes.

NASA Discipline Radiation Health↗

Single Event Effects Test Report IXYS IXTA96P085T P-Channel -85V MOSFET

This study was undertaken to determine the destructive single event effect and degradation susceptibility of the IXTA96P085T P-Channel -85V MOSFET from IXYS. The device was monitored for destructive single event effects and degradation during exposure to a heavy ion beam at the Berkeley Accelerator Space Effects (BASE) Facility at the Lawrence Berkeley National Laboratory (LBNL). Gate and drain currents were measured during irradiation and a basic set of electrical characterizations was performed following each fluence exposure to assess heavy ion induced damage. The test date was April 10, 2024. This characterization is application specific.

MOSFET↗

Cross-sections for 43 Sc, 44 m Sc, and 44 g Sc from two heavy ion reactions

Two different heavy ion reactions were used to produce 43 Sc (t$_{\frac12}$ = 3.891 h), 44g Sc (t$_{\frac12}$ = 4.042 h), and 44m Sc (t$_{\frac12}$ = 58.61 h) among other stable or long-lived chemically separable products. Production cross sections for 19 F + 27 Al and the reverse kinematic reaction 35 Cl + nat B were measured using an MC-SNICS ion source and the Notre Dame FN Tandem Accelerator. 19 F beams from 35 to 60 MeV were produced with beam currents between 40–80 pnA and 35 Cl beams were produced at six entrance energies with comparable beam currents. This work reports nuclear reaction cross sections 27 Al ( 19 F, x) 43 Sc, 27 Al ( 19 F, pn) 44g Sc, and 27 Al ( 19 F, pn) 44m Sc at six energies between 35 and 60 MeV lab energy. Cross sections within the same energy range were measured for 27 Al ( 19 F, 3pn) 42 K and 27 Al ( 19 F, 3p) 43 K. Comparative measurements were performed for the same compound nucleus produced from nat B( 35 Cl, x) 43 Sc, nat B( 35 Cl, pn) 44g Sc, and nat B( 35 Cl, pn) 44m Sc. The measured thin target cross sections show an overestimation by several statistical models for the scandium radioisotopes. This is corroborated by the measured thick target production rates for both entrance channels. This may be due to angular momentum effects of a heavy ion entrance channel compared to light-ion production, but additional work is required to understand this discrepancy. Finally, these measurements demonstrate that the medically useful 43 Sc, 44g Sc, and 44m Sc radioisotopes can be free of the long-lived contaminant 46 Sc without the use of enriched targets, using heavy ion beams and robust target materials.

07 ISOTOPE AND RADIATION SOURCES↗

Mixed-field GCR Simulations for Radiobiological Research Using Ground Based Accelerators

Space radiation is comprised of a large number of particle types and energies, which have differential ionization power from high energy protons to high charge and energy (HZE) particles and secondary neutrons produced by galactic cosmic rays (GCR). Ground based accelerators such as the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) are used to simulate space radiation for radiobiology research and dosimetry, electronics parts, and shielding testing using mono-energetic beams for single ion species. As a tool to support research on new risk assessment models, we have developed a stochastic model of heavy ion beams and space radiation effects, the GCR Event-based Risk Model computer code (GERMcode). For radiobiological research on mixed-field space radiation, a new GCR simulator at NSRL is proposed. The NSRL-GCR simulator, which implements the rapid switching mode and the higher energy beam extraction to 1.5 GeV/u, can integrate multiple ions into a single simulation to create GCR Z-spectrum in major energy bins. After considering the GCR environment and energy limitations of NSRL, a GCR reference field is proposed after extensive simulation studies using the GERMcode. The GCR reference field is shown to reproduce the Z and LET spectra of GCR behind shielding within 20% accuracy compared to simulated full GCR environments behind shielding. A major challenge for space radiobiology research is to consider chronic GCR exposure of up to 3-years in relation to simulations with cell and animal models of human risks. We discuss possible approaches to map important biological time scales in experimental models using ground-based simulation with extended exposure of up to a few weeks and fractionation approaches at a GCR simulator.

Kim, Myung-Hee Y.↗

The mapping & avoidance of high order cavity modes

In this paper a technique developed in 2016 is presented for mapping the multidimensional, multi-mode high order mode landscape of a beam driven super conducting RF cavity. The initial use case for this technique was intended to allow longitudinal gradient control of a beam driven super conducting cavity while simultaneously avoiding many dangerous high order modes and excessive component stresses. This paper will focus on the stability and component stress considerations of the 56MHz superconducting cavity, located in the 4 o’clock sector interaction region of the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The 56MHz cavity is intended to work in conjunction with the Stochastic Cooling system to improve the longitudinal confinement in the central 197MHz RF bucket and thus increase the integrated luminosity during heavy ion beam runs at RHIC.

43 PARTICLE ACCELERATORS↗

Requirements for Simulating Space Radiation With Particle Accelerators

Interplanetary space radiation consists of fully ionized nuclei of atomic elements with high energy for which only the few lowest energy ions can be stopped in shielding materials. The health risk from exposure to these ions and their secondary radiations generated in the materials of spacecraft and planetary surface enclosures is a major limiting factor in the management of space radiation risk. Accurate risk prediction depends on a knowledge of basic radiobiological mechanisms and how they are modified in the living tissues of a whole organism. To a large extent, this knowledge is not currently available. It is best developed at ground-based laboratories, using particle accelerator beams to simulate the components of space radiation. Different particles, in different energy regions, are required to study different biological effects, including beams of argon and iron nuclei in the energy range 600 to several thousand MeV/nucleon and carbon beams in the energy range of approximately 100 MeV/nucleon to approximately 1000 MeV/nucleon. Three facilities, one each in the United States, in Germany and in Japan, currently have the partial capability to satisfy these constraints. A facility has been proposed using the Brookhaven National Laboratory Booster Synchrotron in the United States; in conjunction with other on-site accelerators, it will be able to provide the full range of heavy ion beams and energies required. International cooperation in the use of these facilities is essential to the development of a safe international space program.

Schimmerling, W.↗

Chromosome Aberrations in Normal and Ataxia-Telangiectasia Cells Exposed to Heavy Ions

Although cells derived from Ataxia Telangiectasia (AT) patients are known to exhibit abnormal responses to ionizing radiations, its underlying mechanism still remains unclear. Previously, the authors reported that at the same gamma-irradiation dose AT cells show higher frequencies of misrepair and deletions compared to normal human fibroblast cells. In this study, we investigated the effects of heavy ions beams on chromosomal aberrations in normal and AT cells. Normal and AT fibroblast cells arrested at G0/G1 phase were irradiated with 2 Gy of X-rays, 490 MeV/u Silicon (LET 55 keV/m), 500 MeV/u Iron (LET 185 keV/m) and 200 MeV/u Iron (LET 440 keV/m) particles, and then cells were allowed to repair for 24 hours at 37 degrees before subculture. Calyculin-A induced PCC method was employed to collect G2/M chromosomes and whole DNA probes 1 and 3 were used to analyze chromosomal aberrations such as color-junctions, deletions, simple exchanges (incomplete and reciprocal exanges) and complex-type exchanges. The percentages of aberrant cells were higher when normal and AT cells were exposed to heavy ions compared to X-rays, and had a tendency to increase with increasing LET up to 185 keV/m and then decreased at 440 keV/m. When the frequency of color-junctions per cell was compared after X-ray exposure, AT cells had around three times higher frequency of color-junctions (mis-rejoining) than normal cells. However, at 185 keV/m there was no difference in the frequency of color-junctions between two cell lines. It was also found that the frequency of simple exchanges per cell was almost constant in AT cells regardless LET levels, but it was LET dependent for normal cells. Interestingly, the frequency of simple exchanges was higher for AT cells when it was compared at 185 keV/m but AT cells had more complex-type exchanges at the same LET levels. Heavy ions are more efficient in inducing chromosome aberrations in normal and AT cells compared to X-rays, and the aberration types between normal and AT fibroblast appeared different probably due to difference in the ATM gene function.

Kawata, T.↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Actinide targets for the synthesis of superheavy nuclei

The use of heavy actinide targets, including 243 Am, 240,242,244 Pu, 245,248 Cm, 249 Bk, and 249 Cf, irradiated by intense heavy ion beams of 48 Ca has resulted in a significant expansion of the periodic table since 2000, including the discovery of five new heaviest elements and more than 50 new isotopes. These actinide materials can only be produced by intense neutron irradiation in very high flux reactors followed by chemical processing and purification in specialized hot cell facilities available in only a few locations worldwide. This paper reviews the reactor production of heavy actinides, the recovery and chemical separation of actinide materials, and the preparation of actinide targets for superheavy element experiments. The focus is on 248 Cm, 249 Bk, mixed 249–251 Cf, and 254 Es, including current availabilities and new production processes. The impacts of new facilities, including the Superheavy Element Factory at Dubna, accelerator and separator upgrades at RIKEN, and proposed upgrades to the High Flux Isotope Reactor at Oak Ridge are also described. Examples of recent superheavy element research are discussed as well as future opportunities for superheavy research using actinide targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Genetic effects on heavy ions in drosophila

Drosophila sex-linked recessive lethal mutation test was used to study the dose response relation and relative biological effectiveness of heavy ions. The experiments were performed using the heavy ion beams at BEVALAC of Lawrence Berkeley Laboratory. These experiments were undertaken according to the proposed milestones and included Ne-20, A-40 and Fe-65 ions with respective energies of 600 MeV, 840 MeV and 850 MeV. At these energies several doses of these radiations ranging from 20 to 1280 R were used. Space radiation exposure to astronauts is supposed to be quite low and therefore very low dose experiments i.e., 20 R, were also performed for the three ions. The mutation response was measured in all germ cell types i.e., spermatozoa, spermatids, spermatocytes and spermatogonia of treated Drosophila males. A linear dose frequency relation was observed for most of the range except at high doses where the saturation effect was observed. Also, a very significant difference was observed among the sensitivity of the four germ cell stages where spermatozoa and spermatids were more sensitive. At the higher doses of this range, most of the spermatogonia and spermatocytes were killed. Although comparative and identical experiments with X-rays or neutrons have not been performed, the compassion of our data with the ones available in literature suggest that the heavy ions have a high rbe and that they are several times more effective than low LET X-rays. The rbe compared to neutrons however appears to be only slightly higher.

Kale, P. G.↗

Bispectral analysis of broadband turbulence and geodesic acoustic modes in the T-10 tokamak

Local fluctuations of electrostatic potential, poloidal electric field, magnetic potential and electron density are simultaneously measured in the T-10 tokamak by a heavy ion beam probe (HIBP) having a five-slit energy analyser, which allows an estimate of the turbulent particle flux and $\boldsymbol {E}\times \boldsymbol {B}$ rotation velocity in the off-minor-axis gradient zone of the toroidal plasma column. The high spatial and temporal resolution of the modern multichannel HIBP makes it an effective tool to study plasma oscillations. Motivated by previous work that has documented time-resolved interactions between measured plasma parameters using correlation analysis (coherence of $E_{\textrm {pol}}$ and density $n_e$ , and cross-phase), a new result from bicorrelation analysis (bicoherence of magnetic potential $A_\zeta$ and density $n_e$ , and biphase) is reported for documenting the evidence of wave–wave coupling and energy transfer associated with the interaction between geodesic acoustic modes (GAM) and broadband, quasi-coherent modes.

Physics↗

Heavy-ion production of 77 Br and 76 Br

Many radioisotopes with potential medical applications are difficult to produce routinely, especially those on the proton-rich side of the valley of stability. Current production methods typically use light-ion (protons or deuteron) reactions on materials of similar mass to the target radioisotope, which limits the elemental target material available and may require the use of targets with poor thermal properties (as is the case for the production of radiobromine). These reactions may also create significant amounts of proton-rich decay products which require chemical separation from the desired product in a highly radioactive environment. A promising alternative method using heavy-ion fusion-evaporation reactions for the production of the medically relevant bromine radioisotopes 76 Br (t 1/2 = 16.2 h) and 77 Br (t 1/2 = 57.0 h) is presented. Heavy-ion beams of 28 Si and 16 O were used to bombard natural chromium and copper targets just above the Coulomb barrier at the University of Notre Dame's Nuclear Science Laboratory to produce these bromine and precursor radioisotopes by fusion-evaporation reactions. Production yields for these reactions were measured and compared to PACE4 calculations. In addition to using more robust targets for irradiation, a simple physical–chemical separation method is proposed that will lead to very high radiopurity yields. A summary of accelerator facility requirements needed for routine production of these radioisotopes is also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser power density dependence on charge state distribution of Ta ion laser plasma

Laser power density per pulse, which is commonly expressed with the unit of “W/cm2,” is an important parameter to characterize ablation plasma. To match a design charge state of heavy ion beam induced by a laser ion source, a laser power density must be carefully chosen. Above around 108 W/cm2 of laser power density, laser ablation plasma is emitted from the surface of solid material. Then, up to 109 W/cm2, the most abundant charge state is 1+. Because the ionization energy increases with higher charge states, increasing the laser intensity leads to the charge state distribution shifting higher. Increasing the density to increase charge states also results in lower time of flight due to higher velocities. The maximum laser power density is obtained by the smallest available laser spot size on the target material which is determined by the quality of the laser beam. For many accelerator applications, higher charge state beams are preferred. In particular cases, singly charge ion beams are demanded. Therefore, production of intermediate charge state beams has not been investigated well. In this study, we selected Ta4+ as an example demanded beam and tried to clarify how the transition of charge state distribution depends on laser power density. Conclusively, the possible specification of a laser ion source for Ta4+ delivery was elucidated.

Okamura, Masahiro (ORCID:0000000255521706)↗

Experimental observation of the geodesic acoustic frequency limit for the NBI-driven Alfvén eigenmodes in TJ-II

We study Alfvén Eigenmodes (AEs) in the TJ-II heliac in hydrogen plasmas heated by hydrogen cofield NBI. Taking advantage of the unique TJ-II flexibility in varying plasma current, we have observed strong variation of the AE frequency from f AE ~ 30 to ~ 220 kHz for selected modes. An advanced heavy ion beam probe diagnostic determines the spatial location and internal amplitudes of the modes. The modes satisfy a local AE dispersion relation including the geodesic acoustic frequency that represents the lowest frequency of the mode. Linear MHD-modeling with STELLGAP and FAR3D codes shows that the calculated temporal evolution of the mode frequency reproduces the observed maxima and minima at the same time intervals with a similar frequency range and the radial profile peaks near the outer edge of the observed one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗