Flowfield analysis for high-enthalpy arc heaters
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The topics are presented in viewgraph form and include the following: motivation, approach, planned experimental activities, shock-on-lip studies, and mass addition cooling studies.
Explore the source record for details and available documents.
Heat-transfer rates to two surfaces having widely different catalytic effectiveness are compared at a Mach number of 6 in a low-density stream of partially dissociated nitrogen. The heat-transfer rate to a polished copper cylinder is twice as great as the heat-transfer rate to a silicon-monoxide-coated cylinder when the stream total energy content is 9000 Btu/lb. Various methods for determining the stream energy content, the stream velocity, and the stream Mach number have been developed and compared. It is shown that methods for estimating the stream energy content by means of purely aerodynamic concepts may neglect the sizable fraction of the stream energy contained in molecular dissociation.
Heat flux sensors are routinely used in arc jet facilities to determine heat transfer rates from plasma plume. The goal of this study is to assess the impact of surface composition changes on these heat flux sensors. Surface compositions can change due to oxidation and material deposition from the arc jet. Systematic surface analyses of the sensors were conducted before and after exposure to plasma. Currently copper is commonly used as surface material. Other surface materials were studied including nickel, constantan gold, platinum and silicon dioxide. The surfaces were exposed to plasma between 0.3 seconds and 3 seconds. Surface changes due to oxidation as well as copper deposition from the arc jets were observed. Results from changes in measured heat flux as a function of surface catalycity is given, along with a first assessment of enthalpy for these measurements. The use of cupric oxide is recommended for future heat flux measurements, due to its consistent surface composition arc jets.
A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.
This article is a companion to a paper on heat flux measurements as initiated under a Space Act Agreement in 2011. The current focus of this collaboration between the Institute of Space Systems (IRS) of the University of Stuttgart and NASA Ames Research Center is the comparison and refinement of diagnostic measurements. A first experimental campaign to test different heat flux gages in the NASA Interaction Heating Facility (IHF) and the Plasmawindkanaele (PWK) at IRS was established. This paper focuses on the results of the measurements conducted at IRS. The tested gages included a at face and hemispherical probe head, a 4" hemispherical slug calorimeter, a null-point calorimeter from Ames and a null-point calorimeter developed for this purpose at IRS. The Ames null-point calorimeter was unfortunately defective upon arrival. The measured heat fluxes agree fairly well with each other. The reason for discrepancies can be attributed to signal-to-noise levels and the probe geometry.
2-D axisymmetric time accurate simulations of the EAST facility
The device considered utilizes an unsteady expansion process for the purpose of total-enthalpy multiplication. Analyses were conducted for both perfect and real air in equilibrium, assuming idealized diaphragm bursts, centered expansion waves, and continuum flow. Results of the study showed the expansion tube capable of outperforming the conventional shock tunnel by a factor of approximately 2 in velocity for the same test-section ambient density and pressure. The degree of dissociation is low at all phases of the thermodynamic cycle in the expansion tube; thus the test-section air has a good possibility of being in equilibrium. Maximum pressures involved in the cycle for duplicating a typical reentry from a lunar mission are low enough for existing pressure-vessel techniques. Both the known and anticipated advantages and disadvantages of this new concept are also discussed.
A database of heating and pressure measurements on a 7-deg half-angle cone in a highenthalpy expansion tunnel in CO2 has been generated to support development and validation of computational models to be employed in the design of future Mars missions. Laminar, transitional, and turbulent simulations were performed at the test conditions for comparisons with the data. Close agreement was obtained for both fully-laminar and fully turbulent conditions. For the remaining transitional/turbulent conditions, agreement to within, or slightly more than, the estimated experimental uncertainty was demonstrated. The influence of transition intermittency and transition length models on predicted heating levels was demonstrated, as were differences in turbulent heating predictions generated using various algebraic, one-equation, and two-equation turbulence models. These comparisons provide some measure of confidence in turbulent simulation capabilities; however, because the data were not obtained on a relevant entry vehicle geometry, it is not possible to fully quantify computational uncertainties for the definition of Mars mission aerothermodynamic environments at this time
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The study focuses on the interaction of nitrogen flows with thermal protection systems during atmospheric re-entry for NASA flight missions. The Ares multiphysics coupling tool is employed to investigate the coupling between the fluid (US3D) and material response (Icarus) solvers using various modeling approaches. These approaches include the equilibrium thin-film coefficients approach, a weakly coupled approach with temperature coupling, and an approach considering the full chemical composition of the surface and the transfer of pyrolysis gases. The objective is to understand and accurately represent the mechanisms of nitrogen interaction with the surface, such as nitridation and catalytic recombination. The study aims to assess the accuracy of the different approaches by comparing them to experimental results obtained from NASA arc-jet facilities. By addressing these challenges and improving the understanding of nitrogen-surface interactions, it is expected to enhance the design and performance analysis of thermal protection systems for future missions.
Explore the source record for details and available documents.
Three dimensional finite element analyses using MSC/NASTRAN and MARC are performed to predict the thermal and structural response of various cooling schemes under high heat loads. Steady state heat transfer analyses and elastic stress analyses are performed using MSC/NASTRAN. Elastic/plastic analyses are done using MARC. To help verify these analyses experimentally, a hydrogen-oxygen rocket engine was modified to use the exhaust stream as a high enthalpy, high heat flux source to evaluate various actively cooled, simulated cowl lip (leading edges) segments as well as flat structural segments. Cross flow and parallel flow cooling configurations were tested and analyzed using cooling fluids of water and gaseous hydrogen. In addition, various material types, including high conductivity copper, nickel, and a copper and graphite metal matrix composite were tested and compared.
A major concern in advancing the state of the art technologies for hypersonic vehicles is the development of an aeropropulsion system capable of handling the high heat fluxes during flight. The leading edges of such systems must not only tolerate the maximum heating rates, but must also minimize distortions to the flow field due to excessive blunting and/or thermal warping of the compression surface to achieve the high inlet performance required. A combined analytical and experimental effort to study the aerothermodynamic loads on actively cooled structures for hypersonic applications was established. A hydrogen/oxygen rocket engine was modified to establish a high enthalpy high heat flux environment. The facility provides heat flux levels from about 200 up to 10000 Btu/sq ft/sec. Cross flow and parallel flow regeneratively cooled model can be tested and analyzed by using cooling fluids of water and hydrogen. Results are presented of the experiment and the characteristics of the Hot Gas Test Facility. The predicted temperature results of the cross flow model are compared with the experimental data on the first monolithic specimens and are found to be in good agreement. Thermal stress analysis results are also presented.
A major concern in advancing the state of the art technologies for hypersonic vehicles is the development of an aeropropulsion system capable of handling the high heat fluxes during flight. The leading edges of such systems must not only tolerate the maximum heating rates, but must also minimize distortions to the flow field due to excessive blunting and/or thermal warping of the conmpression surface to achieve the high inlet performance required. A combined analytical and experimental effort to study the aerothermodynamic loads on actively cooled structures for hypersonic applications was established. A hydrogen/oxygen rocket engine was modified to establish a high enthalpy high heat flux environment. The facility provides heat flux levels from about 200 up to 10000 Btu/sq ft/sec. Cross flow and parallel flow regeneratively cooled model can be tested and analyzed by using cooling fluids of water and hydrogen. Results are presented of the experiment and the characteristics of the Hot Gas Test Facility. The predicted temperature results of the cross flow model are compared with the experimental data on the first monolithic specimens and are found to be in good agreement. Thermal stress analysis results are also presented.
An aerothermodynamic database has been generated through both experimental testing and computational fluid dynamics simulations for a 70 deg sphere-cone configuration based on the NASA Mars Pathfinder entry vehicle. The aerothermodynamics of several related parametric configurations were also investigated. Experimental heat-transfer data were obtained at hypersonic test conditions in both a perfect gas air wind tunnel and in a hypervelocity, high-enthalpy expansion tube in which both air and carbon dioxide were employed as test gases. In these facilities, measurements were made with thin-film temperature-resistance gages on both the entry vehicle models and on the support stings of the models. Computational results for freestream conditions equivalent to those of the test facilities were generated using an axisymmetric/2D laminar Navier-Stokes solver with both perfect-gas and nonequilibrium thermochemical models. Forebody computational and experimental heating distributions agreed to within the experimental uncertainty for both the perfect-gas and high-enthalpy test conditions. In the wake, quantitative differences between experimental and computational heating distributions for the perfect-gas conditions indicated transition of the free shear layer near the reattachment point on the sting. For the high enthalpy cases, agreement to within, or slightly greater than, the experimental uncertainty was achieved in the wake except within the recirculation region, where further grid resolution appeared to be required. Comparisons between the perfect-gas and high-enthalpy results indicated that the wake remained laminar at the high-enthalpy test conditions, for which the Reynolds number was significantly lower than that of the perfect-gas conditions.