Search NASA⌕ Search

SEARCH · Search NASA

Results for “high temperature sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

On-Line Lead/Water Heat Exchanger Sensor/System Feasibility: CRADA 462 [Abstract Only]

The purpose of this project is to develop and demonstrate the feasibility of a high-temperature sensor for on-line structural health monitoring (OLSHM) of the novel heat exchanger tubes in the Hydromine lead cooled reactor. The high temperature sensor takes advantage of the Hydromine heat exchanger tube design that has a relatively cool inlet temperature (~ 350 °C) and the tube ends are in an Argon gas blanket rather than being submerged in a corrosive fluid and the tube ends are conveniently accessible from the periphery of the heat exchanger shell.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Temperature, Wireless Seismometer Sensor for Venus

Space agency mission plans state the need to measure the seismic activity on Venus. Because of the high temperature on Venus (462? C average surface temperature) and the difficulty in placing and wiring multiple sensors using robots, a high temperature, wireless sensor using a wide bandgap semiconductor is an attractive option. This paper presents the description and proof of concept measurements of a high temperature, wireless seismometer sensor for Venus. A variation in inductance of a coil caused by the movement of an aluminum probe held in the coil and attached to a balanced leaf-spring seismometer causes a variation of 700 Hz in the transmitted signal from the oscillator/sensor system at 426? C. This result indicates that the concept may be used on Venus.

Ponchak, George E.↗

High-Temperature Gas Sensor Materials with Properties Predicted via First-Principles Calculations with Machine Learning Modeling and Experimental Corroboration

Understanding the temperature dependence of functional properties of sensing materials is vital for their applications in combustion environments. The electron-phonon coupling that derives the electronic structure change with temperatures is a key property of interest as it affects other sensing responses. Herein, we first assess the temperature dependence of band gap renormalization in sensing materials by employing Allen-Heine-Cardona (AHC) theory with density functional theory (DFT) simulations corroborated with experimental observation. As the AHC calculations are impractical for high-throughput screening of materials, we employ data-driven Gaussian process regression to predict the parameters employed in the O’Donnell empirical model from a set of physical features. To mitigate the reliability issues arising from the small size of the dataset, we apply a Bayesian technique to improve the generalizability of the data-driven models as well as to quantify the uncertainty associated with theoretical predictions. These models capture well the overall trend of the O’Donnell parameters with respect to a reduced feature set obtained by transforming the available physical features. Quantifying the associated uncertainty helps us understand the reliability of the predictions and, therefore, the variation of bandgap as a function of temperature for other novel materials. The predicted candidates from machine learning models are further validated by experiments and DFT calculations.

bandgap renormalization↗

Thin Film Ceramic Strain Sensor Development for High Temperature Environments

The need for sensors to operate in harsh environments is illustrated by the need for measurements in the turbine engine hot section. The degradation and damage that develops over time in hot section components can lead to catastrophic failure. At present, the degradation processes that occur in the harsh hot section environment are poorly characterized, which hinders development of more durable components, and since it is so difficult to model turbine blade temperatures, strains, etc, actual measurements are needed. The need to consider ceramic sensing elements is brought about by the temperature limits of metal thin film sensors in harsh environments. The effort at the NASA Glenn Research Center (GRC) to develop high temperature thin film ceramic static strain gauges for application in turbine engines is described, first in the fan and compressor modules, and then in the hot section. The near-term goal of this research effort was to identify candidate thin film ceramic sensor materials and provide a list of possible thin film ceramic sensor materials and corresponding properties to test for viability. A thorough literature search was conducted for ceramics that have the potential for application as high temperature thin film strain gauges chemically and physically compatible with the NASA GRCs microfabrication procedures and substrate materials. Test results are given for tantalum, titanium and zirconium-based nitride and oxynitride ceramic films.

Wrbanek, John D.↗

Novel High Resolution High Temperature In-Line Sensors for Steel Manufacturing

To support efficiency, productivity, yield improvements, and future industry 4.0 and SMART manufacturing objectives for a competitive and prosperous steel industry, this program has embarked on an effort to develop, demonstrate and deploy several novel sensing technologies based on fiber optics for use in production steel facilities. Over the duration of this program, our team has successfully demonstrated three of these technologies: (1) near continuous Rayliegh Scattering optical frequency domain reflectometry (OFDR) sensing with single mode silica fibers for temperature sensing to 700 C, (2) semi-distributed fiber Bragg grating (FBG) sensing with multimode sapphire fibers for temperature sensing to >1600 C, and (3) remote in-situ Raman analysis for slag and flux chemistry analysis at steelmaking temperatures >1550 C. Each of these sensor and interrogation systems was developed, refined, and tested in our labs at Missouri S&T and then successfully deployed at SSAB’s production facilities at two sites, one in Montpelier, IA and one in Mobile, AL.

36 MATERIALS SCIENCE↗

High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring in Coal-Based Power Generation Boilers

In this project, we successfully achieved the goals we proposed: 1. optimization and development of electrochemical sensor, 2. sensor construction and package, 3. sensor testing @Longview Power Plant and data analysis, 4. lab-scale sensor optimization and corrosion database development, 5. electrochemical and corrosion monitoring validation and 6. TEA.

01 COAL, LIGNITE, AND PEAT↗

Development of a high temperature fatigue sensor.

An experimental program was conducted to extend the Tracor Safety Gauge (patent pending) to elevated temperature service. The Safety Gauge is based on a conductive composite device which can be fabricated to function as a fatigue sensor that undergoes an irreversible resistance increase which results from cumulative strain damage. Prototype sensors were developed which appear capable of 1000 deg F operation for short periods of time (approaching one hour); however, bonding difficulties currently limit their use to about 775 deg F. The resistance change of the sensor was generally on the order of 400% or greater as the fatigue life of a titanium alloy (Ti-5Al-2.5Sn) test specimen was approached.

Wells, T. L.↗

High-temperature Strain Sensor and Mounting Development

This report describes Government Work Package Task 29 (GWP29), whose purpose was to develop advanced strain gage technology in support of the National Aerospace Plane (NASP) Program. The focus was on advanced resistance strain gages with a temperature range from room temperature to 2000 F (1095 C) and on methods for reliably attaching these gages to the various materials anticipated for use in the NASP program. Because the NASP program required first-cycle data, the installed gages were not prestabilized or heat treated on the test coupons before first-cycle data were recorded. NASA Lewis Research Center, the lead center for GWP29, continued its development of the palladium-chromium gage; NASA Langley Research Center investigated a new concept gage using Kanthal A1; and the NASA Dryden Flight Research Center chose the well-known BCL-3 iron-chromium-aluminum gage. Each center then tested all three gages. The parameters investigated were apparent strain, drift strain, and gage factor as a function of temperature, plus gage size and survival rate over the test period. Although a significant effort was made to minimize the differences in test equipment between the three test sites (e.g., the same hardware and software were used for final data processing), the center employed different data acquisition systems and furnace configurations so that some inherent differences may be evident in the final results.

Williams, W. Dan↗

REFRACTORY COMPACT HEAT EXCHANGERS WITH EMBEDDED SENSORS ENABLED BY HYBRID ADVANCED SINTERING AND ADDITIVE APPROACH

Structural health monitoring (SHM) of compact heat exchangers (CHXs) operating in extreme environments is essential for ensuring system reliability, safety, and longevity. This study presents the development of high-temperature sensors fabricated via aerosol jet printing (AJP) using platinum ink, selected for its exceptional thermal stability, oxidation resistance, and electrical conductivity. AJP enables precise deposition of fine-feature sensor patterns onto complex geometries, making it well-suited for integration within CHX architectures. To enhance sensor durability, an alumina-based ceramic protective layer was printed over the platinum sensing elements. The sensors demonstrated stable, repeatable performance up to 900?°C during extended thermal cycling. A custom test setup was developed to evaluate sensor accuracy and robustness under steady-state and transient conditions. Substrate screening identified HG-1 ceramic-coated stainless steel as the most effective platform, offering strong adhesion and low resistance. Furthermore, electric field-assisted sintering (EFAS) was employed to embed the sensors into stainless steel 316L matrices without degrading their functionality. Post-embedding electrical tests confirmed sensor integrity, and initial characterization suggests strong potential for in-situ monitoring. This work provides a scalable strategy for integrating high-performance temperature sensors directly into refractory components, advancing embedded SHM technologies for harsh operating environments.

36 - MATERIALS SCIENCE↗

High-Temperature Properties of Piezoelectric Langatate Single Crystals

Langasite type crystals belong to non-polar point group of 32 and do not show any phase transformations up to the melting temperature. Langatate (La3Ga(5.5)Ta(0.5)O14) demonstrates piezoelectric activity better than quartz and possesses attractive properties for high temperature sensors, resonators and filter applications. High-quality and colorless langatate crystals were grown by the Czochralski technique. The electromechanical and electrical properties of langatate crystals in different crystallographic directions were characterized at elevated temperature. The piezoelectric coefficient along x-axis was 7 pC/N as measured by a Berlincourt meter for a plate geometry with an aspect ratio of 10:1. The dielectric constant did not exhibit any significant temperature dependence (K33 approx. 21 at 30 C and K33 approx. 23 at 600 C). Loss tangent at 100 kHz remained <0.003 up to 300 C and <0.65 at 600 C. The dielectric properties along the y-axis were similar and its temperature dependence was analogous to the x-axis. Electromechanically, the inactive z-axis exhibited no resonance with K33 approx. 84 at room temperature, decreasing down to approx. 49 at 600 C. Resistivity of these crystals along x-axis decreased from approx. 6x10(exp 11) omega-cm at room temperature, to approx. 1.6x10(exp 6) omega-cm at 600 C.

Sehirlioglu, Alp↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

High Temperature Thick Film Sensor Development Based on Refractory Oxide Semiconductors

Solid-state, high-temperature sensing devices are required for accurate temperature, strain/stress, and failure monitoring for a range of advanced manufacturing, transportation, and military applications. High temperature conditions limit sensing strategies, where typically traditional metal and semiconductor materials are unstable, and the sensing options are limited to optical spectroscopy methods. In addition, strategies to embed the sensors directly within active components and protective thermal refractory are of interest that permit near-environment sensing which is not possible with the traditional electronic materials and components. Rare-earth chromite semiconductors exhibit some properties of interest for high temperature sensing technologies, such as: high microstructure and chemical stability, relatively high electronic conductivity at high temperatures, and relative thermal expansion coefficient matching to refractory thermal protective insulation (such as high-zirconia and -alumina ceramics). In this work, n-type and p-type doped lanthanum chromites compositions were computationally modelled and prepared, and the electrical, thermoelectric, and thermomechanical properties were measured for the obtained material systems. A few compositions were then processed into thick film health and temperature sensors and tested at high temperatures. To establish relative stability under harsh environment conditions, post- mortem microstructure and chemical composition was characterized after extended and cycle testing at high temperatures.

20 FOSSIL-FUELED POWER PLANTS↗