Search NASA⌕ Search

SEARCH · Search NASA

Results for “high throughput sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-throughput small-angle X-ray scattering reveals effective structure factor transitions linked to high-concentration antibody viscosity

High-concentration monoclonal antibody (mAb) formulations are often constrained by elevated viscosity, largely driven by protein–protein interactions, which complicates manufacturing and limits subcutaneous delivery. Early viscosity risk assessment is essential during discovery, yet traditional measurements require large sample volumes, and lack high-throughput capability. Here, we develop a high-throughput small-angle X-ray scattering (SAXS) protocol to detect mAb self-association at dilute concentrations, enabling early predictive insights into high-concentration viscosity. Synchrotron SAXS measurements were conducted for 21 mAbs formulated in a histidine buffer at pH 6.0. An initial subset of 10 mAbs analyzed across 1–150 mg/mL revealed that effective structure factor transitions in the low-q region, indicative of interparticle interactions, consistently emerged below 25 mg/mL. Subsequently, 11 additional mAbs were analyzed at 1–25 mg/mL using automated liquid handling and flow cells to enable high-throughput screening. High-viscosity mAbs exhibited detectable low-q upturns at concentrations ≤10 mg/mL, whereas low-viscosity mAbs showed downturns. A classification criterion based on effective structure factor transitions accurately classified all high- and low-viscosity mAbs at 150 mg/mL, offering a scalable, sample-efficient alternative to conventional methods. These results extend recent findings on the concentration-dependent sensitivity of SAXS to short-range attractions, demonstrating that they can emerge at lower concentrations than previously reported. This study presents the most comprehensive and diverse SAXS dataset for mAbs reported to date within a single formulation, providing a valuable resource for developing and validating coarse-grained models that can more accurately capture intermolecular interactions governing high-concentration solution behavior, thereby enabling rational antibody engineering and improved developability.

36 MATERIALS SCIENCE↗

Comparing Liquid Vortex Capture & the Rapid Droplet Sampling Interface for Single Cell Mass Spectrometry

High-throughput single-cell mass spectrometry is a rapidly evolving field that requires innovative sampling and ionization techniques to balance speed, sensitivity, and reliability for metabolomic and lipidomic analyses. This study provides a comparative analysis of two cutting-edge ionization platforms for single-cell analysis: Liquid Vortex Capture (LVC) and Rapid Droplet Sampling Interface (RDSI). The performance was benchmarked by testing pharmaceuticals, EquiSPLASH, and single-cell experiments. RDSI demonstrated up to 100-fold improvements in sensitivity for drugs and lipids such as propranolol, amiodarone, atorvastatin, and phosphocholines in water and phosphate-buffered solutions. This was attributed to its low-flow rate operation (3 μL/min) and reduced dilution. Conversely, LVC excelled in handling higher liquid volumes with greater reproducibility due to its higher solvent flow rate (200 μL/min), enabling increased dilution, solubility, and cleaning. Single-cell uptake of atorvastatin incubated for 10 min, or amiodarone incubated for 24 h in HepG2 cells, similarly revealed up to 85-fold enhancement in sensitivity by RDSI for drugs and lipids. These findings highlight the potential of RDSI for enhancing sensitivity in single-cell drug monitoring and lipidomics.

Cahill, John [ORNL] (ORCID:0000000298664010)↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Autonomous organic synthesis for redox flow batteries via flexible batch Bayesian optimization

Traditional trial-and-error methods for materials discovery are inefficient to meet the urgent demands posed by the rapid progression of climate change. This urgency has driven the increasing interest in integrating robotics and machine learning into materials research to accelerate experimental learning. However, idealized decision-making frameworks to achieve maximum sampling efficiency are not always compatible with high-throughput experimental workflows inside a laboratory. For multi-step chemical processes, differences in hardware capacities can complicate the digital framework by introducing constraints on the maximum number of samples in each step of the experiment, hence causing varying batch sizes in variable selection within the same batch. Therefore, designing flexible sampling algorithms is necessary to accommodate the multi-step synthesis with practical constraints unique to each high-throughput workflow. In this work, we designed and employed three strategies on a high-throughput robotic platform to optimize the sulfonation reaction of redox-active molecules used in flow batteries. Our strategies adapt to the multi-step experimental workflow, where their formulation and heating steps are separate, causing varying batch size requirements. By strategically sampling using clustering and mixed-variable batch Bayesian optimization, we were able to iteratively identify optimal conditions that maximize the yields. Our work presents a flexible approach that allows tailoring the machine learning decision-making to suit the practical constraints in individual high-throughput experimental platforms, followed by performing resource-efficient yield optimization using available open-source Python libraries.

Tamura, Clara [Univ. of Washington, Seattle, WA (U↗

Instrumentation and methods for efficient time-resolved X-ray crystallography of biomolecular systems with sub-10 ms time resolution

Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼10 5 –10 9 ) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding of N -acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.

Indergaard, John A. (ORCID:000000022367699X)↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

A high-throughput skim-sequencing approach for genotyping, dosage estimation and identifying translocations

The development of next-generation sequencing (NGS) enabled a shift from array-based genotyping to directly sequencing genomic libraries for high-throughput genotyping. Even though whole-genome sequencing was initially too costly for routine analysis in large populations such as breeding or genetic studies, continued advancements in genome sequencing and bioinformatics have provided the opportunity to capitalize on whole-genome information. As new sequencing platforms can routinely provide high-quality sequencing data for sufficient genome coverage to genotype various breeding populations, a limitation comes in the time and cost of library construction when multiplexing a large number of samples. Here we describe a high-throughput whole-genome skim-sequencing (skim-seq) approach that can be utilized for a broad range of genotyping and genomic characterization. Using optimized low-volume Illumina Nextera chemistry, we developed a skim-seq method and combined up to 960 samples in one multiplex library using dual index barcoding. With the dual-index barcoding, the number of samples for multiplexing can be adjusted depending on the amount of data required, and could be extended to 3,072 samples or more. Panels of doubled haploid wheat lines ( Triticum aestivum , CDC Stanley x CDC Landmark), wheat-barley ( T . aestivum x Hordeum vulgare ) and wheat-wheatgrass ( Triticum durum x Thinopyrum intermedium ) introgression lines as well as known monosomic wheat stocks were genotyped using the skim-seq approach. Bioinformatics pipelines were developed for various applications where sequencing coverage ranged from 1 × down to 0.01 × per sample. Using reference genomes, we detected chromosome dosage, identified aneuploidy, and karyotyped introgression lines from the skim-seq data. Leveraging the recent advancements in genome sequencing, skim-seq provides an effective and low-cost tool for routine genotyping and genetic analysis, which can track and identify introgressions and genomic regions of interest in genetics research and applied breeding programs.

60 APPLIED LIFE SCIENCES↗

Inverse design of photonic surfaces via multi fidelity ensemble framework and femtosecond laser processing

We demonstrate a multi-fidelity (MF) machine learning ensemble framework for the inverse design of photonic surfaces, trained on a dataset of 11,759 samples that we fabricate using high throughput femtosecond laser processing. The MF ensemble combines an initial low fidelity model for generating design solutions, with a high fidelity model that refines these solutions through local optimization. The combined MF ensemble can generate multiple disparate sets of laser-processing parameters that can each produce the same target input spectral emissivity with high accuracy (root mean squared errors < 2%). SHapley Additive exPlanations analysis shows transparent model interpretability of the complex relationship between laser parameters and spectral emissivity. Finally, the MF ensemble is experimentally validated by fabricating and evaluating photonic surface designs that it generates for improved efficiency energy harvesting devices. Our approach provides a powerful tool for advancing the inverse design of photonic surfaces in energy harvesting applications.

97 MATHEMATICS AND COMPUTING↗

Advanced manufacturing provides tailor-made solutions for crystallography with x-ray free-electron lasers

Serial crystallography at large facilities, such as x-ray free-electron lasers and synchrotrons, evolved as a powerful method for the high-resolution structural investigation of proteins that are critical for human health, thus advancing drug discovery and novel therapies. However, a critical barrier to successful serial crystallography experiments lies in the efficient handling of the protein microcrystals and solutions at microscales. Microfluidics are the obvious approach for any high-throughput, nano-to-microliter sample handling, that also requires design flexibility and rapid prototyping to deal with the variable shapes, sizes, and density of crystals. Here, we discuss recent advances in polymer 3D printing for microfluidics-based serial crystallography research and present a demonstration of emerging, large-scale, nano-3D printing approaches leading into the future of 3D sample environment and delivery device fabrication from liquid jet gas-dynamic virtual nozzles devices to fixed-target sample environment technology.

36 MATERIALS SCIENCE↗

Omics-Lethal Human Viruses, Influenza A Experiment ICL105

The purpose of this experiment was to evaluate the host epigenetic response to Influenza A (H5N1) viral infection from human lung adenocarcinoma cells (Calu-3) high throughput sequencing (ChIP-Seq) sample data. Host-associated viral downloads contain one or more primary host-pathogen experimental study metadata design workbooks (supporting metadata only).

59 BASIC BIOLOGICAL SCIENCES↗

Omics-Lethal Human Viruses, Influenza A Experiment ICL106

The purpose of this experiment was to evaluate the human host epigenetic response to Influenza A H5N1 virus and MERS-CoV viral infection from human lung adenocarcinoma cell (Calu-3) high throughput sequencing (MeDIP-Seq) sample data. Host-associated viral downloads contain one or more primary host-pathogen experimental study metadata design workbooks (supporting metadata only).

59 BASIC BIOLOGICAL SCIENCES↗

The microbiome structure of decomposing plant leaves in soil depends on plant species, soil pore sizes, and soil moisture content

Microbial communities are known as the primary decomposers of all the carbon accumulated in the soil. However, how important soil structure and its conventional or organic management, moisture content, and how different plant species impact this process are less understood. To answer these questions, we generated a soil microcosm with decomposing corn and soy leaves, as well as soil adjacent to the leaves, and compared it to control samples. We then used high-throughput amplicon sequencing of the ITS and 16S rDNA regions to characterize these microbiomes. Leaf microbiomes were the least diverse and the most even in terms of OTU richness and abundance compared to near soil and far soil, especially in their bacterial component. Microbial composition was significantly and primarily affected by niche (leaves vs. soil) but also by soil management type and plant species in the fungal microbiome, while moisture content and pore sizes were more important drivers for the bacterial communities. The pore size effect was significantly dependent on moisture content, but only in the organic management type. Overall, our results refine our understanding of the decomposition of carbon residues in the soil and the factors that influence it, which are key for environmental sustainability and for evaluating changes in ecosystem functions.

16S rDNA↗

A streamlined tandem tip-based workflow for sensitive nanoscale phosphoproteomics

Effective phosphoproteome of nanoscale sample analysis remains a daunting task, primarily due to significant sample loss associated with non-specific surface adsorption during enrichment of low stoichiometric phosphopeptide. We develop a tandem tip phosphoproteomics sample preparation method that is capable of sample cleanup and enrichment without additional sample transfer, and its integration with our recently developed SOP (Surfactant-assisted One-Pot sample preparation) and iBASIL (improved Boosting to Amplify Signal with Isobaric Labeling) approaches provides a streamlined workflow enabling sensitive, high-throughput nanoscale phosphoproteome measurements. This approach significantly reduces both sample loss and processing time, allowing the identification of >3000 (>9500) phosphopeptides from 1 (10) µg of cell lysate using the label-free method without a spectral library. It also enables precise quantification of ~600 phosphopeptides from 100 sorted cells (single-cell level input for the enriched phosphopeptides) and ~700 phosphopeptides from human spleen tissue voxels with a spatial resolution of 200 µm (equivalent to ~100 cells) in a high-throughput manner. The new workflow opens avenues for phosphoproteome profiling of mass-limited samples at the low nanogram level.

59 BASIC BIOLOGICAL SCIENCES↗

Human Liver Epithelium Response to HCoV-229E Infection Epigenomics (ACS-DP4)

The purpose of this experiment was to evaluate how wild-type Human coronavirus strain 229E (HCoV-229E) infection alters chromatin accessibility in infected cells only. Sample data was obtained for mock and infected (standard and UV-inactivated) immortalized human liver cells (HuH-7) and collected 24 hrs. post infection. Samples were processed using assay for transposase-accessible chromatin using high-throughput sequencing (ATAC-Seq) and generated bar coded library samples were evaluated for RNA sequencing (RNA-Seq) expression analysis. Processed ATAC-Seq datasets are openly accessible from the download button and contain secondary processed RNA-Seq results files and supporting metadata materials. Data download includes a sample naming key, infection titer metadata, normalized counts, and relevant computational source code information supporting data transparency and reuse.

59 BASIC BIOLOGICAL SCIENCES↗

Crystal Orientation and Defect Mapping in Electron-Beam-Sensitive Zeolites with Near-Axis Transmission Kikuchi Diffraction

Porous materials are vital in catalysis, energy conversion, and environmental remediation. Understanding structural heterogeneity in zeolites is key to linking synthesis, framework intergrowths, and catalytic performance, yet current methods for phase identification and spatial mapping lack sufficient resolution or throughput. We present a high-throughput approach using near-axis transmission Kikuchi diffraction in a scanning electron microscope, achieving high phase and spatial resolution for electron-beam-sensitive zeolites, including ZSM-5 and, for the first time, Zeolite A. Here, this method enables direct visualization of intergrowth features that critically affect catalytic and adsorption behavior, bridging the gap between ensemble-averaged X-ray diffraction and high-resolution but low-throughput transmission electron microscopy. Combining nanoscale mapping with statistical sampling is highly suited for machine-learning pipelines guiding new structure function understanding and could be extended to other beam-sensitive porous materials such as metal–organic or covalent–organic frameworks.

crystallography↗

RICH (Robotic Interface Control & Handling) System for VULCAN

High flux neutron beam and high efficiency detectors warrant quick turn arounds of neutron diffraction measurements at the engineering materials diffractometer VULCAN. Efficient change and alignment of samples and automatic measurements at VULCAN are desired for better use of neutron beam time by users. In this work, we aim to develop a proof-of-concept Robotic Interactive Control & Handling System (RICH) for sample handling at VULCAN that could assist high throughput experiments and reduce the overhead time significantly. This was realized by a six-axis desktop robot with trained AI models. The trained AI models can recognize and locate samples in various types of positions in a live video stream. In addition, we developed smart algorithms which used our models on multiple cameras to recognize where samples are with respect to multiple point of views, and then using user-inputted parameters, align them to perform complex measurements.

42 ENGINEERING↗

Using scalable computer vision to automate high-throughput semiconductor characterization

Abstract High-throughput materials synthesis methods, crucial for discovering novel functional materials, face a bottleneck in property characterization. These high-throughput synthesis tools produce 10 4 samples per hour using ink-based deposition while most characterization methods are either slow (conventional rates of 10 1 samples per hour) or rigid (e.g., designed for standard thin films), resulting in a bottleneck. To address this, we propose automated characterization (autocharacterization) tools that leverage adaptive computer vision for an 85x faster throughput compared to non-automated workflows. Our tools include a generalizable composition mapping tool and two scalable autocharacterization algorithms that: (1) autonomously compute the band gaps of 200 compositions in 6 minutes, and (2) autonomously compute the environmental stability of 200 compositions in 20 minutes, achieving 98.5% and 96.9% accuracy, respectively, when benchmarked against domain expert manual evaluation. These tools, demonstrated on the formamidinium (FA) and methylammonium (MA) mixed-cation perovskite system FA 1−x MA x PbI 3 , 0 ≤ x ≤ 1, significantly accelerate the characterization process, synchronizing it closer to the rate of high-throughput synthesis.

Science & Technology - Other Topics↗