Search NASA⌕ Search

SEARCH · Search NASA

Results for “high variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Renewable Electricity Futures Study - Volume 4: Bulk Electric Power Systems. Operations and Transmission Planning

The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Evolving Role of Extreme Weather Events in the U.S. Power System with High Levels of Variable Renewable Energy

As weather-dependent renewable generation grows, it is important for power system planning to understand the broad trends and correlations between weather, renewable resources, and load. The traditional planning, performed by utilities and system operators, includes the study of system resource adequacy during peak load periods in the summer and winter to ensure the generation and transmission system is appropriate to meet load. But in a power grid with a high penetration of variable renewable energy (i.e., wind and solar), periods of high risk to system resource adequacy may no longer correspond only to hours of peak load. In particular, high shares of variable renewable energy, even when well-forecasted to inform system operations, can further complicate the stress extreme weather events already place on the grid. They also may lead to changes to the types of weather conditions that are most problematic to system operations and resource adequacy due to widespread and extended deficits of wind and solar generation. Accordingly, the focus of reliability assessments in long-term planning studies may need to evolve in the coming years to more fully incorporate weather events that lead to these deficits. This report seeks to identify these new weather events and understand the characteristics of the events that lead to system risk of future systems with higher penetrations variable renewable energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RES-E-NEXT: Next Generation of RES-E Policy Instruments

The rapid deployment of renewable sources of electricity (RES-E) is transforming power systems globally. This trend is likely to continue with large increases in investment and deployment of RES-E capacity over the coming decades. Several countries now have penetration levels of variable RES-E generation (i.e., wind and solar) in excess of 15% of their annual electricity generation; and many jurisdictions (e.g., Spain, Portugal, Ireland, Germany, and Denmark; and, in the United States, Colorado) have experienced instantaneous penetration levels of more than 50% variable generation.1 These penetration levels of variable RES-E have prompted many jurisdictions to begin modifying practices that evolved in an era of readily dispatchable, centralised power systems. Providing insights for the transition to high levels of variable RES-E generation is the focus of this document, which is the final report of the RES-E-NEXT project commissioned by the International Energy Agency’s implementing agreement on Renewable Energy Technology Deployment (IEA-RETD). It presents a comprehensive assessment of issues that will shape power system evolution during the transition to high levels of variable RES-E generation. While policy will be a central tool to sustain the growth of RES-E capacity and to enable power system transitions, the scope of the report extends beyond policy considerations to include the related domains of regulation, power market design, and system operation protocols. This broad scope is in recognition that a changing resource mix with greater penetration levels of variable RES-E has broad implications for grid operations, wholesale and retail power markets, and infrastructure needs. The next decade will be a critical transition period for power system stakeholders, as global deployment of RES-E capacity (and especially variable RES-E capacity) continues to scale-up in many regions of the world. To address increased penetration levels of RES-E in power systems and the new challenges that could emerge, coordinated portfolios of policies, market designs, regulations, and operational protocols are essential. The goal for policymakers is to facilitate investment in RES-E technologies and to enable efficient and reliable system operation, costeffective service delivery, and continued public acceptance. Although the factors that impact the speed and scale of RES-E deployment manifest uniquely in each power system, in the transition to high shares of variable RES-E this report identifies four critical domains and the changing drivers that will shape next-generation policy for each. These domains are introduced in Table I, and comprise the major sections of this report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Greater Penetration of Solar Power via the Use of CSP with Thermal Energy Storage

At high penetration of solar generation there are a number of challenges to economically integrating this variable and uncertain resource. These include the limited coincidence between the solar resource and normal demand patterns and limited flexibility of conventional generators to accommodate variable generation resources. Of the large number of technologies that can be used to enable greaterpenetration of variable generators, concentrating solar power (CSP) with thermal energy storage (TES) presents a number of advantages. The use of storage enables this technology to shift energy production to periods of high demand or reduced solar output. In addition, CSP can provide substantial grid flexibility by rapidly changing output in response to the highly variable net load created byhigh penetration of solar (and wind) generation. In this work we examine the degree to which CSP may be complementary to PV by performing a set of simulations in the U.S. Southwest to demonstrate the general potential of CSP with TES to enable greater use of solar generation, including additional PV.

14 SOLAR ENERGY↗

The Impacts of Demand Response Participation in Capacity Markets

Demand Response is capable of reducing the total amount of generation capacity investment required to ensure electricity system security. We utilise this fact to devise a novel methodology to estimate the contribution of a load-shifting demand response resource to system adequacy. We then simulate an electricity market using mixed complementarity models to determine how the participation of demand response in capacity markets impacts on market outcomes. Demand response primarily affects the equilibrium outcome through the energy market, however demand response also reduces both equilibrium prices and consumer costs through its capacity market contribution. The effect is particularly pronounced when there is a high level of variable renewable generation and initial undercapacity. In the absence of demand response, increased wind generation leads to higher capacity prices as generators seek to offset depressed energy prices. However, we find that demand response's participation in the capacity market can combat these increased capacity prices. These results suggest that demand response participation in capacity markets can mitigate some of the market challenges of renewable integration, particularly that of the 'missing money' problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of high-frequency dissolved oxygen dynamics in a shallow estuary, the Corsica River, Chesapeake Bay

Understanding shallow water biogeochemical dynamics is a challenge in coastal regions, due to the presence of highly variable land-water interface fluxes, tight coupling with sediment processes, tidal dynamics, and diurnal variability in biogeochemical processes. While the deployment of continuous monitoring devices has improved our understanding of high-frequency (12 - 24 hours) variability and spatial heterogeneity in shallow regions, mechanistic modeling of these dynamics has lagged behind conceptual and empirical models. The inherent complexity of shallow water systems is represented in the Corsica River estuary, a small basin within the Chesapeake Bay ecosystem, where abundant monitoring data have been collected from long-term monitoring stations, continuous monitoring sensors, synoptic sensor surveys, and measurements of sediment-water fluxes. A state-of-the-art modeling system, the Semi-implicit Cross-scale Hydroscience Integrated System Model (SCHISM), was applied to the Corsica domain with a high-resolution grid and nutrient loads from the most recent version of the Chesapeake Bay watershed model. The Corsica SCHISM model reproduced observed high-frequency variability in dissolved oxygen, as well as seasonal variability in chlorophyll-a and sediment-water fluxes. Time-series signal analyses using Empirical Model Decomposition and spectral analysis revealed that the diurnal and M2 tide frequencies are the dominant high-frequency modes and physical transport contributes a larger share to dissolved oxygen budgets than biogeochemical processes on an hourly time scale. Heterogeneity and patchiness in dissolved oxygen resulting from phytoplankton distributions and geometry-driven eddies amplify the physical transport effect, and on longer time scales oxygen is controlled more by photosynthesis and respiration. Our simulation demonstrates that interactions among physical and biological dynamics generate complex high-frequency variability in water quality and non-linear reposes to nutrient loading and environmental forcing in shallow water systems.

54 ENVIRONMENTAL SCIENCES↗

Model Predictive Control-based Optimal Coordination of Distributed Energy Resources

Distributed energy resources, such as renewable energy resources (wind, solar), energy storage and demand response, can be used to complement conventional generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging, especially in isolated systems. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation performance. The goals of the optimization problem are to minimize fuel costs and maximize the utilization of wind while considering equipment life of generators and energy storage. Model predictive control (MPC) is used to solve a look-ahead dispatch optimization problem and the performance is compared to an open loop look-ahead dispatch problem. Simulation studies are performed to demonstrate the efficacy of the closed loop MPC in compensating for uncertainties and variability caused in the system.

Mayhorn, Ebony T.↗

A survey on wind power ramp forecasting.

The increasing use of wind power as a source of electricity poses new challenges with regard to both power production and load balance in the electricity grid. This new source of energy is volatile and highly variable. The only way to integrate such power into the grid is to develop reliable and accurate wind power forecasting systems. Electricity generated from wind power can be highly variable at several different timescales: sub-hourly, hourly, daily, and seasonally. Wind energy, like other electricity sources, must be scheduled. Although wind power forecasting methods are used, the ability to predict wind plant output remains relatively low for short-term operation. Because instantaneous electrical generation and consumption must remain in balance to maintain grid stability, wind power's variability can present substantial challenges when large amounts of wind power are incorporated into a grid system. A critical issue is ramp events, which are sudden and large changes (increases or decreases) in wind power. This report presents an overview of current ramp definitions and state-of-the-art approaches in ramp event forecasting.

17 WIND ENERGY↗

Project 57 Air Monitoring Report: January 1 through December 31, 2017

On April 24, 1957, the Atomic Energy Commission (AEC) (now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley northeast of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DOD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a non-nuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Various radiological surveys were performed in the area and in 2007, the DOE expanded the demarked Contamination Area (CA) by posting signs 200 to 400 ft (60 to 120 m) outside of the original fence. Plutonium in soil attaches preferentially to smaller particles (Tamura, 1985; Friesen, 1992; Murarik et al., 1992; and Misra et al., 1993). Therefore, redistribution of soil particles by wind (dust) and water are the mechanisms most likely to transport plutonium beyond the boundary of the Project 57 CA. Monitoring was implemented in 2011 by Desert Research Institute (DRI) to determine if radionuclide contamination was detectable in samples of airborne dust and to characterize meteorological and environmental parameters that influence dust transport. Initially, two monitoring stations consisting of radiological, meteorological, and dust sampling equipment were installed near the southeast and northeast corners of the CA. In January 2015, the original monitoring stations were dismantled and moved farther to the west along the CA boundary. This move was made to place the monitoring stations downwind of ground zero and the High Contamination Area (HCA) during the dominant northerly and southerly winds. Samples of particles suspended in the air are collected every two weeks and submitted for laboratory assessments of gross alpha and gross beta radioactivity, and for determinations of gamma-emitting radionuclides. In calendar year (CY) 2017, the mean gross alpha concentration at monitoring station P57-4 was approximately 4.25 times the value at monitoring station P57-3. In CY2015 and CY2016, the difference in mean gross alpha concentration at the two stations was approximately 1.5. The mean gross alpha concentrations at P57-3 and P57-4 were approximately 1.9 and 7.9 times, respectively, the mean gross alpha concentrations at the surrounding Community Environmental Monitoring Program (CEMP) stations. The minimum gross alpha concentrations reported for the Project 57 stations are in the range of the minimum values observed at the CEMP stations. However, maximum gross alpha concentrations are greater than the maximum concentrations observed at the surrounding CEMP stations. Gamma spectroscopy analyses resulted in the detection of seven radionuclides. Except for americium-241 (Am-241), all reported radionuclides occur naturally in the environment. The Am-241 detection by gamma spectroscopy was confirmed by alpha spectroscopy. During each quarter of CY2017, four suspended particulate matter samples were selected for alpha spectroscopy analysis. Two were selected each quarter from the regular biweekly samples collected at each of the two monitoring stations. Of the eight samples from P57-3, one was reported to have plutonium-238 (Pu-238) above the minimum detectable activity (MDA) and five were reported to have plutonium 239/240 (Pu-239/240) above the MDA. Of the eight samples from P57-4, three were reported to have Pu-238 above the MDA and six were reported to have Pu-239/240 above the MDA. Soil material is also transported by saltation, which is a wind driven phenomena that bounces sand-sized soil particles across the land surface because they are too heavy to be suspended in the air. Samples of particles transported by saltation were collected downwind and upwind of the CA at both monitoring stations in May 2017 after a 190-day deployment and again in September 2017 after a 114-day deployment. Mass of the saltation samples was determined after oven drying. The September sample had greater mass than the May sample. The same relationship was observed for the suspended particulate matter samples during periods of saltation sample collection. The difference in the collected mass appears to be because of the amount of soil moisture. Higher soil moisture exerts additional isotopic bonds between soil particles and water molecules, and between water molecules that envelop soil particles, making it more difficult for wind to raise the particles as dust. In general, samples collected from saltation traps facing south contained more material than samples collected from traps facing north. This suggests that although saltation material may have been moving back and forth in conjunction with the two dominant wind directions, there was a net trend for saltation material to be transported toward the north. Radiological analyses of the saltation samples show that the smaller particle size faction (<63 μm) generally produced the highest activity levels of Am-241, Pu-238, and Pu-239/240. In general, the isotope activity levels decreased as the particle size increased. These results are consistent with the expectation that the greatest potential for transport of radiological contamination is with the smaller particles. Thermoluminescent dosimeters (TLDs) indicated that the average annual external radioactivity dose at the monitoring stations is slightly higher than the dose determined at the surrounding CEMP stations, but approximately half of the estimated national average dose received by the general public from exposure to natural sources. The TLDs at the Project 57 monitoring stations are exposed to both natural sources (terrestrial and cosmic) and radioactive releases from the Project 57 CA. Winds in excess of approximately 15 mph (24 km/hr) begin to generate dust movement by saltation or suspension, as determined by the monitoring instruments. Saltated particles, PM10 (i.e., inhalable dust), and PM2.5 (i.e., fine particulate dust) exhibit an approximately exponential increase with increasing wind speed. The greatest concentrations of dust occurred for winds exceeding 20 mph (32 km/hr). When the wind/dust analysis was performed for winds separated into the dominant northerly and southerly wind directions, it was evident that the northerly winds generated the higher PM10 concentrations and had the dominate influence on the PM10 concentration determined for all wind speeds when all wind directions were evaluated together. During the year, winds in excess of 20 mph (32 km/hr) occurred approximately one percent of the time. Although winds sufficient to generate dust occur at the Project 57 site, they are infrequent and of short duration. A preliminary assessment of individual wind events suggests that dust generation in response to specific wind conditions is highly variable. Wind speeds that would be expected to generate noticeable dust may not do so in every instance. Additionally, saltation transport in response to wind conditions was less common than expected. These variations were likely because of the influence of meteorological and environmental parameters other than wind.

54 ENVIRONMENTAL SCIENCES↗

Autonomous Energy Grids

Current frameworks to monitor, control, and optimize large-scale energy systems are becoming increasingly inadequate because of significantly high penetration levels of variable generation and distributed energy resources being integrated into electric power systems; the deluge of data from pervasive metering of energy grids; and a variety of new market mechanisms, including multilevel ancillary services. This paper outlines the concept of autonomous energy grids (AEGs). These systems are supported by a scalable, reconfigurable, and self-organizing information and control infrastructure, are extremely secure and resilient (self-healing), and can self-optimize in real time to ensure economic and reliable performance while systematically integrating energy in all forms. AEGs rely on cellular building blocks that can self-optimize when isolated from a larger grid and participate in optimal operation when interconnected to a larger grid. This paper describes the key concepts and research necessary in the broad domains of optimization theory, control theory, big data analytics, and complex system theory and modeling to realize the AEG vision.

autonomous energy grids↗

A hybrid electrical power system for aircraft application.

Possible improvements to present aircraft electrical power systems for use in future advanced types of aircraft have been investigated. The conventional power system is examined, the characteristics of electric loads are reviewed, and various methods of power generation and distribution are appraised. It is shown that a hybrid system, with variable-frequency generation and high-voltage dc distribution, could overcome some of the limitations of the conventional system.

Lee, C. H.↗

Macroscopic Violation of Three Cauchy-Schwarz Inequalities Using Correlated Light Beams From an Infra-Red Emitting Semiconductor Diode Array

We briefly review quantum mechanical and semi-classical descriptions of experiments which demonstrate the macroscopic violation of the three Cauchy-Schwarz inequalities: g(sup 2)(sub 11)(0) greater than or equal to 1; g(sup 2)(sub 11)(0) greater than or equal to g(sup 2)(sub 11)(t), (t approaches infinity); (the absolute value of g(sup 2)(sub 11)(0))(exp 2) less than or equal to g(sup 2)(sub 11)(0) g(sup 2)(sub 11)(0). Our measurements demonstrate the violation, at macroscopic intensities, of each of these inequalities. We show that their violation, although weak, can be demonstrated through photodetector current covariance measurements on correlated sub-Poissonian Poissonian, and super Poissonian light beams. Such beams are readily generated by a tandem array of infrared-emitting semiconductor junction diodes. Our measurements utilize an electrically coupled array of one or more infrared-emitting diodes, optically coupled to a detector array. The emitting array is operated in such a way as to generate highly correlated beams of variable photon Fano Factor. Because the measurements are made on time scales long compared with the first order coherence time and with detector areas large compared with the corresponding coherence areas, first order interference effects are negligible. The first and second inequalities are violated, as expected, when a sub-Poissonian light beam is split and the intensity fluctuations of the two split beams are measured by two photodetectors and subsequently cross-correlated. The third inequality is violated by bunched (as well as anti-bunched) beams of equal intensity provided the measured cross correlation coefficient exceeds (F - 1)/F, where F is the measured Fano Factor of each beam. We also investigate the violation for the case of unequal beams.

Edwards, P. J.↗

Electric Vehicle Managed Charging: Estimating the Potential Bulk Power System Value

With more and more electric vehicles (EVs) on the road, the grid of the future can greatly benefit from EV managed charging, which coordinates charging based on people's travel needs, electricity supply, and grid conditions. The added flexibility could be especially valuable for the bulk power system as it transitions to high shares of variable renewable generation, like wind and solar. Numerous studies have estimated the potential value of EV managed charging. In this study, NREL leveraged more detailed modeling of EV adoption, use, charging, and bulk power system operations to understand the potential value. Unique to this study, NREL modeled different charging flexibility types and dispatch mechanisms - as well as participation rates among drivers in having their EV charging managed - starting from vehicle-specific descriptions of charging flexibility. The study is based on a passenger light-duty vehicle adoption scenario with 100% EV sales by 2035 and a New England power system in 2038 with 84% clean generation and 26% of the electric load met by net imports. The 2038 New England light-duty vehicle feet is modeled as 45% electric.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗