Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pumped Thermal Energy Storage Using Low-Cost Particles and a Fluid Bed Heat Exchanger for Maximum Power Efficiency

Robust, efficient, cost-effective long-duration electricity storage (LDES) solutions can enhance grid resiliency, support existing transmission and distribution infrastructure, and enable a greater share of low-cost, variable alternative energy sources to penetrate the market. To meet this need, the project team at the National Renewable Energy Laboratory developed a transformative LDES system based on pumped thermal energy storage (TES) using low-cost particles and a fluid bed heat exchanger for maximum power efficiency (PUMP). The PUMP system is composed of high-temperature, low-cost particle TES coupled with an advanced pressurized fluid bed heat exchanger (PFB HX) that supports a high-efficiency pumped thermal energy storage (PTES) system integrated with concentrating solar thermal power (CSP). The PUMP project developed and de-risked a PFB HX and particle CSP system intended to be integrated with reversible turbomachinery and a modeling tool to assess PTES cost and performance.

14 SOLAR ENERGY↗

PRIMO – The Oil & Gas Well Plugging Optimizer

This work presents PRIMO’s main capabilities and introduces the PRIMO web application, an intuitive user interface that leverages our sophisticated mathematical optimization model to rigorously optimize P&A priorities and plugging campaign efficiency. The web app simplifies user interaction, provides a powerful data management framework, and supports a broad user base (e.g., state agencies, well owners/operators, and plugging companies) to use PRIMO for decision-making. Specifically, we provide a demonstration of how to input the information on candidate wells, plugging campaign budget, user-defined priority and efficiency criteria to PRIMO. A real-world case study that consists of 1411 oil and gas wells and impact and efficiency priorities (e.g., well age, well proximity to schools/hospitals, well accessibility, distance between wells in projects) is presented to showcase PRIMO’s core capabilities: (i) ranking a candidate well population based on priorities, (ii) recommending high-impact and high-efficiency P&A projects, and (iii) assigning impact and efficiency scores to projects allowing for rigorous quantitative comparison among them.

02 PETROLEUM↗

Oneida Indian Nation Facility Energy Efficiency Project (Final Technical Report)

The Oneida Indian Nation (“Oneida”) implemented a comprehensive energy efficiency project across nearly 30 facilities over the course of the project period. Grounded in findings from a 2018 energy audit, the project installed LED lighting, high-efficiency HVAC systems, programmable thermostats, variable speed drives, and kitchen exhaust controls across 28 Nation facilities and the Turning Stone Resort and Casino (TSRC) campus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Nb 3 Sn sputtering on SRF structures

Superconducting radiofrequency (SRF) cavities are the key technology to compact, high-efficiency, and cost-effective CW SRF accelerators. Further improvements in the efficiency can be realized by using novel materials such as Nb 3 Sn coated on the inner surface of SRF cavities. The Nb 3 Sn coatings enable cavity operation at 4 K, where the Nb 3 Sn coated cavities are already very efficient and have high intrinsic quality factors. Advances in Nb3Sn coatings on the inner surface of SRF cavities showed the potential for this material to significantly cut the capital and operating costs of SRF accelerators. Several approaches have been and are being investigated for coating SRF cavities with Nb 3 Sn. Magnetron sputtering is a versatile technique in that it has been shown to produce Nb 3 Sn films on flat Nb target in a single phase and a precisely controlled thickness, low defect levels, and a favorable morphology. Deposition of Nb 3 Sn films on SRF cavities have also shown promising RF superconducting properties. However, sputter coating of Nb 3 Sn on SRF cavities requires further development to be used in accelerators.

43 PARTICLE ACCELERATORS↗

Opportunity Assessment for U.S. Industry: Energy-Efficient Cooling Technologies in Mexico

Mexico's rapidly expanding room air conditioner (AC) market presents a strategic opportunity for U.S. manufacturers to strengthen North American supply chains while addressing critical energy infrastructure challenges. With demand for room AC units in residential and commercial buildings projected to drive a 26 GW increase in Mexico’s peak electrical load by 2050, high-efficiency air conditioning systems offer both substantial market opportunities and essential grid stability benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ductless Heat Pump Program

The Verde Ductless Heat Pump (DHP) Program expanded access to high-efficiency electric heating and cooling technologies for households in priority communities within the Portland Metro area. Funded by the U.S. Department of Energy’s Building Technologies Office (DE-EE0010132), the program combined residential ductless heat pump deployment with community-based outreach, participant support, contractor partnerships, and system development to improve program delivery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation↗

Simultaneous Reduction of NOx and Fuel Consumption for Off-Road Powertrains

Simultaneously reducing criteria pollutants and fuel consumption is important for clean air and improving vehicle total cost of ownership. The goal of this effort was focused on a 90% NOx reduction and 10% fuel savings for an off-road 407 kW diesel engine. The baseline was a production Fiat Powertrain 13L engine and aftertreatment system meeting 0.4 g/kW-hr NOx. The baseline system was quantified over the NRTC, RMC, new low load cycle and five field cycles. A next generation engine was built incorporating several fuel-efficient design features, including a higher compression ratio, increased fuel-rail pressure, low-friction piston rings, and a high-efficiency variable-geometry turbocharger. Cylinder deactivation and EGR pump technologies were added to this engine as well. The combination was optimized prior to adding advanced aftertreatment systems, showing the trade-off of engine out NOx and exhaust temperature. Two next-generation catalyst technologies were employed into a LO-SCR plus main SCR system, both with and without an electric heater upstream of the LO-SCR. These catalysts were hydrothermally aged to simulate significant field use. Dual SCR dosing with newly developed controls played a critical role in achieving the proper split between the upstream LO-SCR and the downstream main SCR. Adding a next generation mixer for the downstream SCR proved essential in obtaining the final results. The optimal configuration required adding an electric heater to elevate the exhaust temperature at the LO-SCR for early cycle NOx reduction. The final results showed a 94.8% NOx reduction and 15.7% fuel savings on the composite NRTC.

McCarthy, James [Eaton Corporation]↗

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Technology Assessment and Modelling of Three Terminal Tandem Solar Cells for In-Space Utilization

NASA seeks a sustained human presence on the lunar surface. High-efficiency and resilient energy systems are critical to supporting habitats, scientific outposts, and lunar surface operations. Photovoltaics have long been the backbone of space power systems, transitioning from silicon solar cells to multi-junction III-V solar cells, which now dominate state-of-the-art (SOA) technology. Multi-junction cells achieve high efficiency by layering semiconductors, each absorbing a specific portion of the solar spectrum. However, efficiency gains are increasingly constrained by device physics and manufacturing complexity. Additionally, higher-order junctions pose challenges for accurate modelling and performance characterization due to difficulties in replicating the AM0 spectrum.

solar cells↗

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Cryocooler↗

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Zero boil-off↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗