Search NASA⌕ Search

SEARCH · Search NASA

Results for “housing characteristics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the Insoluble Solids of the 241-17F and 241-49H Pump house Water Sample

Six different water samples from 241-17F and 241-49H pump house were analyzed for chemical and physical characteristics as part of efforts to understand recent mechanical seal failures associated with four new cooling water pumps. A focus of this work was characterization of any “as found” insoluble solids. The insoluble material found in the FCRW (F-Area caustic water treated with sodium chromate at 241-17F) sample are mostly magnetite (Fe3O4 or possibly equipment rust) and silica. It was found that 26% of measured FCRW particles have at least one dimension larger than 15 microns. The insoluble particles found in the source water, domestic water (FDW), are mostly kaolin (aluminosilicate) and some iron oxide. All found FDW particles were larger than 15 microns. The insoluble particles of the other source water, FArea well water (FWW), were mostly iron oxide with some trapped cations like calcium. Only 8% of found FWW particles were bigger than 15 microns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extending the utility of forest cover maps

A computer-assisted map analysis system is discussed that characterizes timber supply in terms of standing timber; accessibility considering various harvesting factors; and availability as affected by ownership patterns of timberlands. Factors affecting harvesting include proximity to existing roads and consideration of terrain characteristics. Availability considerations include size of ownership, housing density and excluded areas. The model is demonstrated for a seventy square mile tract in western Massachusetts.

Berry, J. K.↗

The use of a numerical filter to correct airborne temperature measurements for the effects of sensor lag

A numerical filter for transforming measured temperature signals into a close approximation of the actual temperature signal is described. The filter is derived by minimizing the mean-square error of the system, and assuming a knowledge of the characteristics of the sensing element and its housing. The equation representing the frequency-response function of the numerical filter is given. Input and output spectra for a filter applied to a case with negligible noise and a noise level of 1.5 percent of the total power in the input spectrum are analyzed, and the numerical weights for these two cases are calculated. Phase angle and gain for the entire system are examined. It is noted that the filter can enhance spectral components as high as 8 Hz with little phase and gain degradation over the bandwidth.

Ritter, John A.↗

Loudness and annoyance response to simulated outdoor and indoor sonic booms

The sonic boom simulator of the Langley Research Center was used to quantify subjective loudness and annoyance response to simulated indoor and outdoor sonic boom signatures. The indoor signatures were derived from the outdoor signatures by application of house filters that approximated the noise reduction characteristics of a residential structure. Two indoor listening situations were simulated: one with the windows open and the other with the windows closed. Results were used to assess loudness and annoyance as sonic boom criterion measures and to evaluate several metrics as estimators of loudness and annoyance. The findings indicated that loudness and annoyance were equivalent criterion measures for outdoor booms but not for indoor booms. Annoyance scores for indoor booms were significantly higher than indoor loudness scores. Thus, annoyance was recommended as the criterion measure of choice for general use in assessing sonic boom subjective effects. Perceived level was determined to be the best estimator of annoyance for both indoor and outdoor booms, and of loudness for outdoor booms. It was recommended as the metric of choice for predicting sonic boom subjective effects.

Leatherwood, Jack D.↗

Engineering science research issues in high power density transmission dynamics for aerospace applications

This paper discusses analytical and experimental approaches that will be needed to understand dynamic, vibro-acoustic and design characteristics of high power density rotorcraft transmissions. Complexities associated with mathematical modeling of such systems will be discussed. An overview of research work planned during the next several years will be presented, with emphasis on engineering science issues such as gear contact mechanics, multi-mesh drive dynamics, parameter uncertainties, vibration transmission through bearings, and vibro-acoustic characteristics of geared rotor systems and housing-mount structures. A few examples of work in progress are cited.

Singh, Rajendra↗

Microgravity Disturbance Characterization of the Quench Module Insert (QMI) Phase Change Device (PCD)

The Materials Science Research Facility (MSRF) is a multi-user, multi-purpose facility for materials science research. One experiment within the MSRF will be the Quench Module Insert (QMI), a high-temperature furnace with unique capabilities for processing different classes of materials. The primary functions of the QMI furnace are to melt, directionally solidify, and quench metallic samples, providing data to aid in understanding the effects of the microgravity environment on the characteristics of these processed metals. The QMI houses sealed individual sample ampoules containing material to be processed. Quenching of the samples in the QMI furnace is accomplished by releasing low-melting-point metallic shoes into contact with the outside of the sample ampoule, dissipating heat and cooling the sample inside. The impact from this method of quench will induce sample vibrations which could be large enough to adversely affect sample quality. Utilizing breadboard hardware, the sample quench sequence, releasing the shoes, was conducted. Data was collected from accelerometers located on the breadboard sample cartridge, indicating the maximum acceleration achieved by the sample. The primary objective of the test described in this presentation was to determine the acceleration imparted on the sample by the shoe contact. From this information, the science community can better assess whether this method of quench will allow them to obtain the data they need.

Gattis, Christy↗

Overview of an Indoor Sonic Boom Simulator at NASA Langley Research Center

A facility has been constructed at NASA Langley Research Center to simulate the soundscape inside residential houses that are exposed to environmental noise from aircraft. This controllable indoor listening environment, the Interior Effects Room, enables systematic study of parameters that affect psychoacoustic response. The single-room facility, built using typical residential construction methods and materials, is surrounded on adjacent sides by two arrays of loudspeakers in close proximity to the exterior walls. The arrays, containing 52 subwoofers and 52 mid-range speakers, have a usable bandwidth of 3 Hz to 5 kHz and sufficient output to allow study of sonic boom noise. In addition to these exterior arrays, satellite speakers placed inside the room are used to augment the transmitted sound with rattle and other audible contact ]induced noise that can result from low frequency excitation of a residential house. The layout of the facility, operational characteristics, acoustic characteristics and equalization approaches are summarized.

Klos, Jacob↗

A comparison of building system parameters between affordable and market-rate housing in New York City

Low-income households in the United States experience higher than average energy burdens (defined as the proportion of household income spent on energy utilities), and many of these households struggle to simultaneously pay for rent, energy, and basic household necessities. The analysis presented here in this study examines whether the underlying characteristics of buildings and their energy systems could contribute to this disparity for affordable housing residents in New York City. It combines an energy audit dataset of 7,328 multifamily buildings with a database of properties receiving local, state, or federal housing subsidies. The results of this analysis indicate that the building-level installed equipment in large (greater than 50,000 square feet) affordable housing buildings in New York City is more efficient than that in market-rate buildings, but this trend largely disappears when considering overall building characteristics, such as location, size, or age. Significant differences in the types of systems installed in affordable and market-rate housing are also observed, as well as the types of energy efficiency recommendations made by energy auditors. However, these latter data were not normalized by building system characteristics, as that analysis is much more difficult to interpret for categorical data such as heating system type. These findings indicate that retrofit policies and building performance standards focused on affordable housing will likely need to account for underlying differences in building characteristics between affordable and market-rate housing to achieve intended impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Propagation characteristics of some novel coplanar waveguide transmission lines on GaAs at MM-wave frequencies

Three new Coplanar Waveguide (CPW) transmission lines, namely, Suspended CPW (SCPW), Stripline-like Suspended CPW (SSCPW) and Inverted CPW (ICPW), are proposed and also analyzed for their propagation characteristics. The substrate thickness, permittivity and dimensions of housing are assumed to be arbitrary. These structures have the following advantages over conventional CPW. Firstly, the ratio of guide wavelength to free space wavelength is closer to unity which results in larger dimensions and hence lower tolerances. Secondly, the effective dielectric constant is lower and hence the electromagnetic field energies are concentrated more in the air regions which should reduce attenuation. Thirdly, for a prescribed impedance level, the above structures have a wider slot width for identical strip width. Thus, low impedance lines can be achieved with reasonable slot dimensions. Fourthly, in an inverted CPW shunt mounting of active devices, such as Gunn and IMPATT diodes, between the strip and the metal trough is possible. This feature further enhances the attractiveness of the above structures. Lastly, an E-plane probe type transition from a rectangular waveguide to suspended CPW can also be easily realized. The computed results for GaAs at Ka-band illustrate the variation of normalized guide wavelength, effective dielectric constant and the characteristic impedance as a function of the: (1) frequency; (2) distance of separation between the trough side walls; (3) normalized strip and slot widths; and (4) normalized air gap.

Simons, Rainee N.↗

Experimental forced vibration responses of test houses during the Edwards Air Force Base phase of the national sonic boom test program

Experimental vibration studies were conducted on two houses to determine some of the dynamic response characteristics, resulting from sonic boom. The primary objectives of the vibration tests were to identify the mode shapes associated with the various frequencies determined from the sonic boom response data, and to obtain some basic information about the vibration behavior of buildings in general. The results are presented of forced sinusoidal vibration studies of some components of the test structures. Included are acceleration response data on selected walls, wall surface modal patterns, and vibration induced noise measurements at various locations in the test structures.

Carden, H. D.↗

Control of the flexible modes of an advanced technology geostationary platform

A controls analysis is conducted on an advanced technology geostationary platform. This spacecraft is a large flexible structure with a payload of Earth-sensing instruments which will collect data from Earth's oceans, land, and atmosphere as a part of the bold initiative mission to Planet Earth proposed by NASA. This program will provide a collection of data from a family of spacecraft in both low-Earth orbit and geostationary orbit, which will afford a global definition of the Earth as a system with the capability to predict future events resulting from human and natural forces. The platform concept studied here is a large flexible structure with a payload of eighteen instruments. Because the platform is in geostationary orbit, these instruments have sensitive pointing accuracy requirements, in the range of 0.1 to 0.0001 degrees, which must be satisfied. The structure housing the instruments is large and flexible with characteristic low natural frequencies, so active control is necessary for vibration suppression.

Dewalt, Diane V.↗

System and method using in-situ electromagnetic diagnostic for real-time projectile characterization

The present disclosure relates to a system for detecting characteristics of a moving element. The system may include a tubular housing having a tubular first portion having a first end and a second end, with the first end forming an input port and the second end forming an output port. A source of wireless electromagnetic energy projects a wireless electromagnetic energy signal, travelling in a first direction, into the input port and through an interior area defined by the tubular first portion. A signal processing subsystem detects at least one characteristic of the signal after the signal is reflected back to the first end after having interacted with the element as the element moves past the output port of the housing.

Chang, Tammy↗

Full-flow fluid filter

Etched-disk filter was developed with fluid passageways in configuration which allows relatively unrestricted flow of fluid and has stagnation areas for collection of impurities. In addition, filter housing without center post was developed to improve flow characteristics.

Toth, L. R.↗

A preliminary investigation of finite-element modeling for composite rotor blades

The results from an initial phase of an in-house study aimed at improving the dynamic and aerodynamic characteristics of composite rotor blades through the use of elastic couplings are presented. Large degree of freedom shell finite element models of an extension twist coupled composite tube were developed and analyzed using MSC/NASTRAN. An analysis employing a simplified beam finite element representation of the specimen with the equivalent engineering stiffness was additionally performed. Results from the shell finite element normal modes and frequency analysis were compared to those obtained experimentally, showing an agreement within 13 percent. There was appreciable degradation in the frequency prediction for the torsional mode, which is elastically coupled. This was due to the absence of off-diagonal coupling terms in the formulation of the equivalent engineering stiffness. Parametric studies of frequency variation due to small changes in ply orientation angle and ply thickness were also performed. Results showed linear frequency variations less than 2 percent per 1 degree variation in the ply orientation angle, and 1 percent per 0.0001 inch variation in the ply thickness.

Lake, Renee C.↗

A preliminary investigation of finite-element modeling for composite rotor blades

The results from an initial phase of an in-house study aimed at improving the dynamic and aerodynamic characteristics of composite rotor blades through the use of elastic couplings are presented. Large degree of freedom shell finite element models of an extension twist coupled composite tube were developed and analyzed using MSC/NASTRAN. An analysis employing a simplified beam finite element representation of the specimen with the equivalent engineering stiffness was additionally performed. Results from the shell finite element normal modes and frequency analysis were compared to those obtained experimentally, showing an agreement within 13 percent. There was appreciable degradation in the frequency prediction for the torsional mode, which is elastically coupled. This was due to the absence of off-diagonal coupling terms in the formulation of the equivalent engineering stiffness. Parametric studies of frequency variation due to small changes in ply orientation angle and ply thickness were also performed. Results showed linear frequency variations less than 2 percent per 1 degree variation in the ply orientation angle, and 1 percent per 0.0001 inch variation in the ply thickness.

Lake, Renee C.↗

Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass

The International X-ray Observatory project seeks to make an X-ray telescope assembly with 14,000 flexible glass segments. The glass used is commercially available SCHOTT D263 glass. Thermal expansion causes the mirror to distort out of alignment. A housing material is needed that has a matching coefficient of thermal expansion (CTE) so that when temperatures change in the X-ray mirror assembly, the glass and housing pieces expand equally, thus reducing or eliminating distortion. Desirable characteristics of this material include a high stiffness/weight ratio, and low density. Some metal alloys show promise in matching the CTE of D263 glass, but their density is high compared to aluminum, and their stiffness/weight ratio is not favorable. A laminate made from carbon fiber reinforced plastic (CFRP) should provide more favorable characteristics, but there has not been any made with the CTE matching D263 Glass. It is common to create CFRP laminates of various CTEs by stacking layers of prepreg material at various angles. However, the CTE of D263 glass is 6.3 ppm/ C at 20 C, which is quite high, and actually unachievable solely with carbon fiber and resin. A composite laminate has been developed that has a coefficient of thermal expansion identical to that of SCHOTT D263 glass. The laminate is made of a combination of T300 carbon fiber, Eglass, and RS3C resin. The laminate has 50% uni-T300 plies and 50% uni-E-glass plies, with each fiber-layer type laid up in a quasi-isotropic laminate for a total of 16 plies. The fiber volume (percent of fiber compared to the resin) controls the CTE to a great extent. Tests have confirmed that a fiber volume around 48% gives a CTE of 6.3 ppm/ C. This is a fairly simple composite laminate, following well established industry procedures. The unique feature of this laminate is a somewhat unusual combination of carbon fiber with E-glass (fiberglass). The advantage is that the resulting CTE comes out to 6.3 ppm/ C at 20 C, which matches D263 glass. The trick with this laminate is to establish the proper fiber volume to get the desired CTE. Laminates were made with several different fiber volumes and coupons were tested to establish the relationship between fiber volume and CTE. Testing proved that fiber volume should be about 48%.

Robinson, David↗

Transducers for ultrasonic limb plethysmography

The design, construction, and performance characteristics of ultasonic transducers suitable for limb plethysmography are presented. Both 3-mm-diameter flat-plate and 12-mm-diameter hemispheric ceramic transducers operating at 2 MHz were fitted in 1-mm thick epoxy-resin lens/acoustic-coupling structures and mounted in exercie-EKG electrode housings for placement on the calf using adhesive collars. The effects of transducer directional characteristics on performance under off-axis rotation and the electrical impedances of the transducers were measured: The flat transducer was found to be sensitive to rotation and have an impedance of 800 ohms; the hemispheric transducer, to be unaffected by rotation and have an impedance of 80 ohms. The use of hemispheric transducers as both transmitter and receiver, or of a flat transducer as transmitter and a hemispheric transducer as receiver, was found to produce adequate dimensional measurements, with minimum care in transducer placement, in short-term physiological experiments and long-term (up to 7-day) attachment tests.

Nickell, W. T.↗