Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Long-distance recording of the humidity over the sea

A procedure is developed for long distance recording of humidity over the sea that uses humidity detectors of the sorption type, whose electrical properties depend on the relative humidity of the air. The moisture sensitive material of the hygristor is the organic polymer polyacrylonitryl, deposited on silver electrodes and thermally treated. In the measurements of the relative humidity from 60% to 95%, the resistance of the hygristor varies from several hundred kiloohms to a few kiloohms, and is an essentially nonlinear function of the humidity.

Buklanov, V. V.↗

A42F-03: Small-Scale Variability in Tropical Tropopause Layer Humidity

Recent advances in statistical parameterizations of cirrus cloud processes for use in global models are highlighting the need for information about small-scale fluctuations in upper tropospheric humidity and the physical processes that control the humidity variability. To address these issues, we have analyzed high-resolution airborne water vapor measurements obtained in the Airborne Tropical TRopopause EXperiment (ATTREX) over the tropical Pacific between 14 and 20 km. Using accurate and precise 1-Hz water vapor measurements along approximately-level aircraft flight legs, we calculate structure functions spanning horizontal scales ranging from about 0.2 to 50 km, and we compare the water vapor variability in the lower (about 14 km) and upper (16-19 km) Tropical Tropopause Layer (TTL). We also compare the magnitudes and scales of variability inside TTL cirrus versus in clear-sky regions. The measurements show that in the upper TTL, water vapor concentration variance is stronger inside cirrus than in clear-sky regions. Using simulations of TTL cirrus formation, we show that small variability in clear-sky humidity is amplified by the strong sensitivity of ice nucleation rate to supersaturation, which results in highly-structured clouds that subsequently drive variability in the water vapor field. In the lower TTL, humidity variability is correlated with recent detrainment from deep convection. The structure functions indicate approximately power-law scaling with spectral slopes ranging from about minus 5 divided by 3, to minus 2.

water vapor↗

No-reheat air-conditioning

Air conditioning system, for environmentally controlled areas containing sensitive equipment, regulates temperature and humidity without wasteful and costly reheating. System blends outside air with return air as dictated by various sensors to ensure required humidity in cooled spaces (such as computer room).

Obler, H. D.↗

The Vertical Structure of Relative Humidity and Ozone in the Tropical Upper Troposphere: Intercomparisons Among In Situ Observations, A-Train Measurements and Large-Scale Models

In situ measurements in the tropics have shown that in regions of active convection, relative humidity with respect to ice in the upper troposphere is typically close to saturation on average, and supersaturations greater than 20% are not uncommon. Balloon soundings with the cryogenic frost point hygrometer (CFH) at Costa Rica during northern summer, for example, show this tendency to be strongest between 11 and 15.5 km (345-360 K potential temperature, or approximately 250-120 hPa). this is the altitude range of deep convective detrainment. Additionally, simultaneous ozonesonde measurements show that stratospheric air (O3 greater than 150 ppbv) can be found as low as approximately 14 km (350 K/150 hPa). In contrast, results from northern winter show a much drier upper troposphere and little penetration of stratospheric air below the tropopause at 17.5 km (approximately 383 K). We show that these results are consistent with in situ measurements from the Measurement of Ozone and water vapor by Airbus In-service airCraft (MOZAIC) program which samples a wider, though still limited, range of tropical locations. To generalize to the tropics as a whole, we compare our insitu results to data from two A-Train satellite instruments, the Atmospheric Infrared Sounder (AIRS) and the Microwave Limb Sounder (MLS) on the Aqua and Aura satellites respectively. Finally, we examine the vertical structure of water vapor, relative humidity and ozone in the NASA Goddard MERRA analysis, an assimilation dataset, and a new version of the GEOS CCM, a free-running chemistry-climate model. We demonstrate that conditional probability distributions of relative humidity and ozone are a sensitive diagnostic for assessing the representation of deep convection and upper troposphere/lower stratosphere mixing processes in large-scale analyses and climate models.

Selkirk, Henry B.↗

Sample Materials Considerations for Curating and Processing Pristine MSR Samples

The perseverance rover is collecting and caching samples of Mars as part of the Mars 2020 mission, which represents the first leg of a multi-mission Mars Sample Return Campaign. The MSR Campaign is an international partnership that will result in delivery of the first martian samples to Earth that were not delivered through meteoritic infall. All meteorites, regardless of how they were handled from recovery to curation, have experienced uncontrolled entry and exposure to the terrestrial environment. Whilst meteorite deliveries are serendipitous, they are also unplanned events that require reactionary responses for recovery and curation. However, with the direct return of pristine astromaterials from another body, we are afforded the ability to design a facility in advance of sample delivery to keep those samples in a pristine (i.e., as returned) state for an indefinite period of time. Given that the curation and processing infrastructure needs to be made out of something, it is important to choose materials for the pristine curation environment that will optimize between the need to effectively process samples and the need to minimize contamination of the samples. The Johnson Space Center (JSC) has an optimized list of materials that have been used in previous sample return missions that includes 304/316 Stainless Steel, Teflon, and T6061 Aluminum (1). This set of materials are compatible with inorganic, organic, and biological cleanliness requirements and protocols. Furthermore, only these materials are permitted to come in contact with pristine samples. We note that JSC uses Neoprene and Hypalon for the gloves on their gloveboxes, but the glove material never comes in direct contact with the samples, only the approved materials. The MSR sample tubes will be made of Ti, so Ti may be an acceptable material for making tools, but the minor and trace element abundances of 304 and 316 stainless steel are well known and do not inhibit scientific investigations of metals, including HSE (2). More work is needed to determine whether the same is true for Ti alloys. In addition to defining the materials in the pristine environment, one must also choose whether the pristine environment will be under vacuum or under a specific atmospheric composition and pressure. Although JAXA has successfully implemented pristine curation vacuum chambers for their Hayabusa and Hayabusa2 samples (3), a vacuum environment is not appropriate for martian samples because it may drive deliquescence of mineral phases in the samples that are sensitive to pressure and relative humidity (4). Consequently, the pristine environment for the martian samples should be under an inert gas. It will be crucial to minimize the number of gases that come into direct contact with samples and these gases will need to be high purity and consistent throughout the pristine isolators. Samples at JSC are stored under high purity gaseous nitrogen (1). Dry N2 gas has not been a problem for N isotope studies for high-T release phases, but an additional inert atmosphere like Ar may be needed for samples where there is a particular concern about low-T release of N from bulk sample analysis. References: (1) McCubbin FM, et al. (2019) Space Science Reviews, 215, 1-81. (2) Day JMD, et al. (2018) Meteorit. Planet. Sci. 53:1283-1291. (3) Yada, T., et al., (2014). Meteorit. Planet. Sci. 49, 135-153. (4) Tosca NJ, et al. (2021). Astrobiology, in press, doi:10.1089/ast.2021.0115.

F M McCubbin↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗

Climate Impact on CO2 Capture Efficiency and Levelized Cost of Liquid solvent-based DAC (Direct Air Capture) System

The transition towards net-zero emission poses economic, technical, and political challenges for the commercial-scale deployment of CO2 removal technologies by 2050. The opportunities for large-scale deployment will largely depend on the distinctive conditions found in the different locations of the world such as energy cost, carbon intensity of energy source, construction, transportation, and weather conditions. In this work, we focus on one of the promising negative emission technology, DAC (Direct Air Capture), and its response to different weather conditions. This work presents two potential operation scenarios: (i) natural gas standalone, (ii) grid electricity connected DAC plant. For the first time, we investigated the influence of temperature and RH (relative humidity) of the air on liquid-based DAC system and its response to carbon capture efficiency and levelized cost of carbon capture with operational sensitivity analysis. It is observed that the overall energy demand decreases from 11.1 to 8.3 GJ/ton-CO2 as the CO2 capture rate increases from 40 to 85%. We observed that a CO2 capture rate of 75% is only possible above 17°C even at 90% RH and this drops tremendously at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low RH as expected. The sensitivity analysis showed that weather conditions are insensitive to CO2 capture efficiency for the liquid-solvent based DAC plant for both scenarios. In addition, higher CO2 capture efficiency is achievable from lower upstream methane emissions and carbon intensity of grid electricity (for grid-connected scenario). Lastly, the levelized cost of natural gas standalone scenario varies from 239.7 to 408.8 $/t-CO2 is sensitive to temperature conditions more than relative humidity and compared to electricity grid-connected scenario, from 265.3 to 440.1 $/t-CO2.

An, Keju↗

Temperature and Humidity Dependence of a Polymer-Based Gas Sensor

This paper quantifies the temperature and humidity dependence of a polymer-based gas sensor. The measurement and analysis of three polymers indicates that resistance changes in the polymer films, due to temperature and humidity, can be positive or negative. The temperature sensitivity ranged from +1600 to -320 ppm/nd the relative sensitivity ranged from +1100 to -260 ppm/%.

temperature humidity gas sensor polymers↗

Climate Drivers of Global Wildfire Burned Area

Wildfire is an integral part of the Earth system, but at the same time it can pose serious threats to human society and to certain types of terrestrial ecosystems. Meteorological conditions are a key driver of wildfire activity and extent, which led to the emergence of the use of fire danger indices that depend solely on weather conditions. The Canadian Fire Weather Index (FWI) is a widely used fire danger index of this kind. Here, we evaluate how well the FWI, its components, and the climate variables from which it is derived, correlate with observation-based burned area (BA) for a variety of world regions. We use a novel technique, according to which monthly BA are grouped by size for each Global Fire Emissions Database (GFED) pyrographic region. We find strong correlations of BA anomalies with the FWI anomalies, as well as with the underlying deviations from their climatologies for the four climate variables from which FWI is estimated, namely, temperature, relative humidity, precipitation, and wind. We quantify the relative sensitivity of the observed BA to each of the four climate variables, finding that this relationship strongly depends on the pyrographic region and land type. Our results indicate that the BA anomalies strongly correlate with FWI anomalies at a GFED region scale, compared to the strength of the correlation with individual climate variables. Additionally, among the individual climate variables that comprise the FWI, relative humidity and temperature are the most influential factors that affect the observed BA. Our results support the use of the composite fire danger index FWI, as well as its sub-indices, the Build-Up Index (BUI) and the Initial Spread Index (ISI), comparing to single climate variables, since they are found to correlate better with the observed forest or non-forest BA, for the most regions across the globe.

Wildfire↗

Retrieval of total precipitable water using radiometric measurements near 183.3 GHz and 90 GHz frequencies

Data collected with the Advanced Microwave Moisture Sounder (AMMS), which operates in the 183.3 GHz range, are compared to measurements collected at 22 GHz in order to show that the 183 GHz measurements are more sensitive to total precipitable water (W) values than the 22 GHz measurements. Radiative transfer calculations for the upwelling microwave emission from the ocean surface were performed at the AMMS frequencies with a variety of atmospheric temperature and humidity profiles. The derived brightness temperatures at these frequencies are compared with W values derived from the humidity profiles. It is observed that the sensitivity between the brightness temperatures and W values at the AMMS channel is greater than 130 K/g per sq cm and 12 K/g per sq cm for the 22 GHz frequency.

Wang, J. R.↗

The Effect of Updraft Entrainment on Convective Cell Deepening in Realistic Large-Eddy Simulations

Entrainment of surrounding cooler and drier air into convective updrafts is one of the key processes that influence deep convection initiation and growth. Numerous studies have investigated the effect of entrainment on isolated convective cloud growth in idealized simulations, but the importance of this effect in realistic conditions with many interacting convective clouds remains uncertain. We examine the impact of entrainment on the depth reached by convective clouds in realistic large-eddy simulations (LES) over central Argentina during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign. Cloudy updrafts and their associated properties are assigned to convective cells tracked with radar reflectivity signatures. Several thousand convective cells are tracked over two high convective available potential energy (CAPE) and two low CAPE cases that support cells of varying depths and intensities. Entrainment is calculated explicitly as the fluxes of air into the outer surface of each cloudy updraft. Single-predictor logistic regression models are used to determine the relative importance of updraft, near-updraft, and preconvective initiation atmospheric conditions in predicting whether convective cells become deep. We then build a multiple-predictor regression model pairing important updraft and meteorological metrics with fractional entrainment rate. The probability of cells transitioning to deep convection is most sensitive to ambient 600-hPa relative humidity (42% of total metric contribution to cloud depth predictability), followed by low-level CAPE (28%), cloud-base updraft width (19%), and fractional entrainment (11%). Thus, the initial width of the updraft along with potential buoyancy and its dilution through the midtroposphere collectively determine whether deep convection will result from shallower clouds.

54 ENVIRONMENTAL SCIENCES↗

A preliminary study of the application of HCMM satellite data to define initial and boundary conditions for numerical models: A case study in St. Louis, Missouri

Infrared and visible HCMM data were used to examine the potential application of these data to define initial and boundary conditions for mesoscale numerical models. Various boundary layer models were used to calculate the distribution of the surface heat flux, specific humidity depression (the difference between the specific humidity in the air at approxmately the 10 m level and the specific humidity at the ground), and the eddy vicosity in a 72 km by 72 km area centered about St. Louis, Missouri. Various aspects of the implications of the results on the meteorology of St. Louis are discussed. Overall, the results indicated that a reasonable estimate of the surface heat flux, urban albedo, ground temperature, and specific humidity depression can be obtained using HCMM satellite data. Values of the ground-specific humidity can be obtained if the distribution of the air-specific humidity is available. More research is required in estimating the absolute magnitude of the specific humidity depression because calculations may be sensitive to model parameters.

Vukovich, F. M.↗

Analysis of the GOES 6.7 micrometer channel observations during FIRE 2

Clouds form in moist environments. FIRE Phase II Cirrus Implementation Plan (August, 1990) noted the need for mesoscale measurements of upper tropospheric water vapor content. These measurements are needed for initializing and verifying numerical weather prediction models and for describing the environment in which cirrus clouds develop and dissipate. Various instruments where deployed to measure the water vapor amounts of the upper troposphere during FIRE II (e.g. Raman lidar, CLASS sonds and new cryogenic frost hygrometer on-board aircraft). The formation, maintenance and dissipation of cirrus clouds involve the time variation of the water budget of the upper troposphere. The GOES 6.7 mu m radiance observations are sensitive to the upper tropospheric relative humidity, and therefore proved extremely valuable in planning aircraft missions during the field phase of FIRE II. Warm 6.7 mu m equivalent black body temperatures indicate a relatively dry upper troposphere and were associated with regions generally free of cirrus clouds. Regions that were colder, implying more moisture was available may or may not have had cirrus clouds present. Animation of a time sequence of 6.7 mu m images was particularly useful in planning various FIRE missions. The 6.7 mu m observations can also be very valuable in the verification of model simulations and describing the upper tropospheric synoptic conditions. A quantitative analysis of the 6.7 mu m measurement is required to successfully incorporate these satellite observations into describing the upper tropospheric water vapor budget. Recently, Soden and Bretherton (1993) have proposed a method of deriving an upper tropospheric humidity based on observations from the GOES 6.7 mu m observations. The method is summarized in the next section. In their paper they compare their retrieval method to radiance simulations. Observations were also compared to ECMWF model output to assess the model performance. The FIRE experiment provides a unique opportunity to further verify the GOES upper tropospheric relative humidity retrieval scheme by providing (1) aircraft observations to cross-validate the calibration of the GOES 6.7 mu m channel, (2) accurate upper tropospheric water vapor concentrations for verification, and (3) veritical variability of upper tropospheric water vapor.

Soden, B. J.↗

The Effects of Aircraft Wake Dynamics on Contrail Development

Results of large-eddy simulations of the development of young persistent ice contrails are presented, concentrating on the interactions between the aircraft wake dynamics and the ice cloud evolution over ages front a few seconds to approx. 30 min. The 3D unsteady evolution of the dispersing engine exhausts, trailing vortex pair interaction and breakup, and subsequent Brunt-Vaisala oscillations of the older wake plume are modeled in detail in high-resolution simulations, coupled with it bulk microphysics model for the contrail ice development. The simulations confirm that the early wake dynamics can have a strong influence on the properties of persistent contrails even at late times. The vortex dynamics are the primary determinant of the vertical extent of the contrail (until precipitate ton becomes significant): and this together with the local wind shear largely determines the horizontal extent. The ice density, ice crystal number density, and a conserved exhaust tracer all develop and disperse in different fashions from each other. The total ice crystal number can be significantly reduced due to adiabatic compression resulting from the downward motion of the vortex system, even for ambient conditions that are substantially supersaturated with respect to ice. The fraction of the initial ice crystals surviving, their spatial distribution and the ice mass distribution are all sensitive to the aircraft type, ambient humidity, assumed initial ice crystal number, and ambient turbulence conditions. There is a significant range of conditions for which a smaller transport such as a B737 produces as significant a persistent contrail as a larger transport such as a B747, even though the latter consumes almost five times as much fuel. The difficulties involved in trying to minimize persistent contrail production are discussed.

Lewellen, D. C.↗

A Path to Improving Simulated Properties of Low Clouds over the Beaufort Sea using Airborne In Situ Observations of Subgrid-Scale Variability

Arctic low clouds influence the evolution of the Arctic system through their effects on radiative fluxes, boundary layer mixing, stability, turbulence, humidity, and precipitation. Unfortunately, atmospheric models and retrospective analysis (reanalysis) products struggle to accurately simulate the occurrence and properties of low clouds in the Arctic. One of the main reasons for this problem are the possible unrealistic assumptions that models/reanalyses make about the subgrid-scale (SGS) variability of meteorological properties, as well as the relationship between SGS variability and grid-scale (GS) cloud properties. We utilize cloud and thermodynamic data of low level (primarily) liquid clouds collected from two aircraft campaigns conducted over the Beaufort Sea to better understand and characterize this problem. Examining data from the September 2014 Arctic Radiation-IceBridge Sea and Ice Experiment (ARISE) airborne campaign reveals that GS cloud water variability is closely related with SGS distribution of total water (i.e. water vapor + cloud water). Multiple models/reanalyses use SGS supersaturated total water (relative to GS saturation) as a threshold for partitioning available water for condensation, and indeed we find significant correlation between GS cloud water and SGS supersaturation. However, we also find that the assumption of a static threshold of 100% saturation to be unrealistic. Empirical calculations from the ARISE data show a large sensitivity of this threshold to GS relative humidity, and so a microphysical parameterization allowing the threshold to vary according to GS thermodynamic properties may result in more realistic GS cloud water values. Finally, to determine how sensitive the ARISE-derived results are to that particular campaign, we include additional data from the First International Satellite Cloud Climatology Project (ISCCP) Regional Experiment (FIRE)–Arctic Cloud Experiment (ACE) conducted in 1998. The inclusion of the second dataset will help with demonstrating the robustness of the results and their utility in improving the representation of Arctic clouds in models and reanalyses.

J Brant Dodson↗

Insight the process of hydrazine gas adsorption on layered WS 2 : a first principle study

The process of hydrazine gas adsorption on layered WS 2 has been systematically studied from first principle calculations. Our results demonstrate that this adsorption process is exothermic, and hydrazine molecules are physically adsorbed. The layer-dependent adsorption energy and interlayer separation induced by van der Waals interaction exerted by hydrazine molecules lead to the difficulty in desorbing hydrazine molecules from layered WS 2 as the number of layers increases. The most interesting finding is the emergence of localized impurity states below the Fermi level upon the hydrazine adsorption, irrespective of the number of WS 2 layers, resulting in a significant effect on the band structures and subsequently changing its electrical conductivity. Furthermore, a layer-dependent small charge transfer occurs between hydrazine and layered WS 2 , leading to a charge redistribution and considerable polarization in the adsorbed systems. The existence of defects and the humidity, on the other hand, influences the sensitivity of layered WS 2 to the hydrazine adsorption. Here, obtained results show that a perfectly layered WS 2 might be a promising candidate as an efficient nanosensor to detect such toxic gas in dry environment.

36 MATERIALS SCIENCE↗

Investigating the Causes and Impacts of Convective Aggregation in a High Resolution Atmospheric GCM

Abstract A ∼50 km resolution atmospheric general circulation model (GCM) is used to investigate the impact of radiative interactions on spatial organization of convection, the model's mean state, and extreme precipitation events in the presence of realistic boundary conditions. Mechanism‐denial experiments are performed in which synoptic‐scale feedbacks between radiation and dynamics are suppressed by overwriting the model‐generated atmospheric radiative cooling rates with its monthly varying climatological values. When synoptic‐scale radiative interactions are disabled, the annual mean circulation and precipitation remain almost unchanged, however tropical convection becomes less aggregated, with an increase in cloud fraction and relative humidity in the free troposphere but a decrease in both variables in the boundary layer. Changes in cloud fraction and relative humidity in the boundary layer exhibit more sensitivity to the presence of radiative interactions than variations in the degree of aggregation. The less aggregated state is associated with a decrease in the frequency of extreme precipitation events, coincident with a decrease in the dynamical contribution to the magnitude of extreme precipitation. At regional scales, the spatial contrast in radiative cooling between dry and moist regions diminishes when radiative interactions are suppressed, reducing the upgradient transport of energy, degree of aggregation, and frequency of extreme precipitation events. However, the mean width of the tropical rain belt remains almost unaffected when radiative interactions are disabled. These results offer insights into how radiation‐circulation coupling affects the spatial organization of convection, distributions of clouds and humidity, and weather extremes.

54 ENVIRONMENTAL SCIENCES↗