Device having hybrid hydraulic-electric architecture

A device having a hybrid hydraulic-electric architecture includes a hydraulic pump/motor having first and second ports, and an electric motor. The device is configured to connect to two or more pressure rails, each pressure rail containing hydraulic fluid at a different pressure than the other pressure rails. A flow of hydraulic fluid from one of the pressure rails is driven through the hydraulic pump/motor, and a pressure difference exists between the first and second ports. The electric motor is configured to control a flow rate of the flow of hydraulic fluid and/or the pressure difference.

Li, Perry Yan-Ho↗

HARMONY: Large-Scale Architecture Search for Efficient Hybrid Language Models

As large language models scale to trillions of parameters, their computational and memory requirements present critical challenges for efficient training and deployment. While Mixture of Experts (MoE) architectures enable efficient scaling through sparse parameter activation, and state-space models like Mamba offer linear-time complexity, principled methods for combining these paradigms remain undeveloped. We introduce HARMONY (Hybrid Architecture Research for Mamba, Optimized with Neural efficiencY), a multi-objective evolutionary neural architecture search framework for discovering efficient hybrid language models that integrate Transformer attention mechanisms, Mixture-of-Experts routing, and Mamba state-space components. Through large-scale distributed search using 16,384 MI250X GPUs on the Frontier supercomputer, HARMONY explores a comprehensive design space encompassing six attention variants (MHA, MQA, GQA, MLA, SWA, and Mamba-2), variable MoE configurations with both routed and shared experts, and extensive Mamba hyperparameters. Our framework discovers heterogeneous architectures that balance training performance with computational efficiency through multi-objective optimization incorporating latency penalties and fitness-based selection. Analysis of discovered architectures reveals that optimal hybrid designs favor heterogeneous component mixing rather than homogeneous patterns, with Mamba-2 and Multi-Head Latent Attention (MLA) emerging as preferred mechanisms. Discovered architectures demonstrate superior training efficiency: our best configuration achieves a final perplexity of 1.0874 with 2.38B parameters while processing 4,320 tokens/second, outperforming significantly larger manually designed models. Full-scale evaluation shows HARMONY's top architectures achieve better loss trajectories than equivalently-sized models using state-of-the-art configurations including Mixtral, Jamba, and Samba. Additionally, we demonstrate 91% weak scaling efficiency when training discovered 36B-parameter models across 1,024 GPUs. HARMONY is released as an open framework with comprehensive tools for building and training hybrid models using expert-data-pipeline parallelism, democratizing access to automated architecture design for next-generation language models.

Herron, Emily [ORNL] (ORCID:0000000273008172)↗

Comparison of Linear and Rotary Electric Machine Topologies for a Hybrid Hydraulic Electric Architecture of Off-Highway Vehicles

Electrification of off-highway vehicles offers the benefits of improved energy efficiency, enhanced controllability, and reduction in greenhouse gas emissions. However, progress towards electrification has been limited by the low power density of electric components compared to hydraulic components. A recently proposed hybrid hydraulic electric vehicle architecture provides a potential solution to these power density challenges by minimizing the required power rating of the electric components. This paper investigates the optimal design of linear and rotary electric machines for this new system architecture. Key performance metrics are identified for the electric machine, several variants of electric machines are analytically sized and compared for two different power levels, and an FEA-assisted design optimization is performed on promising candidates. Based on the optimization results, it is shown that an axial flux rotary machine is most suitable for implements requiring high power ratings, while the linear machine's form factor makes it a compelling candidate for lower power implements.

42 ENGINEERING↗

Hybrid Hydraulic-Electric Architecture (HHEA) for Mobile Machines (Final Report)

Traditionally, off-road mobile machines such as excavators and wheel loaders are primarily powered by hydraulics, and throttling valves are used to control their work circuits. In recent years, two general trends are towards more energy efficient systems and electrification. With electrification, both efficiency and control performance can be improved by the elimination of throttling losses and the use of high-bandwidth inverter control. Electrification is generally accomplished with Electro-hydraulic actuators (EHA) but they are limited to lower powered systems due to the high cost of electric machines capable of high power or high torque. This project proposes a new system architecture for off-road vehicles - Hybrid Hydraulic Electric Architecture (HHEA) to improve efficiency and control performance without requiring large electric machines. The widely applicable architecture combines hydraulic power and electric power in such a way that the majority of power is provided hydraulically while electric drives are used to modulate this power. In particular, HHEA utilizes multiple common pressure rails to transmit the majority of power and small electric machines to modulate the power. The energy-saving potential of the the HHEA has been validated for the work circuits of a variety of mobile machines, from small 5-ton excavators to medium sized 20-ton excavators and wheel loaders, and representative duty cycles to reduce energy input by 50-80% compared to the commercial state-of-art load-sensing systems. In addition, the corner power requirements of the electrical machines can be downsized by 85% compared to the EHA approach. Various tradeoff studies have also been conducted, including sensitivities to individual components performances, controllers, accumulator sizes, and variations of the system architecture etc. A control strategy has been developed to maintain or exceed the motion control precision compared to current systems. The motion control strategy consists of a nominal controller, based on a passivity-based backstepping design, and a transition controller, based on least-norn feedforward design. The nominal controller is used in between common pressure rail switches whereas the transition controller compensates for any disturbance that common pressure rail switchings inflict on the system. The control strategy has been experimentally validated on both a medium pressure (200bar) hardware-in-the-loop (HIL) testbed and a high pressure (300+bar) HIL testbed. An efficient and power-dense integrated electric-hydraulic machine consisting of an axial flux electric machine and a radial hydrostatic piston hydraulic machine has been designed, constructed and tested. The machine has an active material power density of 6.1kW/kg, a rated speed of 12500 RPM, and a design efficiency of 85%. This is among the highest power density electric machines using conventional materials. While the integrated machine was designed for modulating the hydraulic power within the HHEA, it can also be used in other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid deep learning architecture for general disruption prediction across tokamaks

In this paper, we present a new deep learning disruption prediction algorithm based on important findings from explorative data analysis which effectively allows knowledge transfer from existing devices to new ones, thereby predicting disruptions using very limited disruptive data from the new devices. Here, the explorative data analysis conducted via unsupervised clustering techniques confirms that time-sequence data are much better separators of disruptive and non-disruptive behavior than the instantaneous plasma state data with further advantageous implications for a sequence-based predictor. Based on such important findings, we have designed a new algorithm for multi-machine disruption prediction that achieves high predictive accuracy on the C-Mod (AUC=0.801), DIII-D (AUC=0.947) and EAST (AUC=0.973) tokamaks with limited hyperparameter tuning. Through numerical experiments, we show that boosted accuracy (AUC=0.959) is achieved on EAST predictions by including in the training only 20 disruptive discharges, thousands of non-disruptive discharges from EAST, and combining this with more than a thousand discharges from DIII-D and C-Mod. The improvement of predictive ability obtained by combining disruptive data from other devices is found to be true for all permutations of the three devices. Furthermore, by comparing the predictive performance of each individual numerical experiment, we find that non-disruptive data are machine-specific while disruptive data from multiple devices contain device-independent knowledge that can be used to inform predictions for disruptions occurring on a new device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid deep learning architecture for general disruption prediction across tokamaks

In this paper, we present a new deep learning disruption prediction algorithm based on important findings from explorative data analysis which effectively allows knowledge transfer from existing devices to new ones, thereby predicting disruptions using very limited disruptive data from the new devices. The explorative data analysis conducted via unsupervised clustering techniques confirms that time-sequence data are much better separators of disruptive and non-disruptive behavior than the instantaneous plasma state data with further advantageous implications for a sequence-based predictor. Based on such important findings, we have designed a new algorithm for multi-machine disruption prediction that achieves high predictive accuracy on the C-Mod (AUC=0.801), DIII-D (AUC=0.947) and EAST (AUC=0.973). tokamaks with limited hyperparameter tuning. Through numerical experiments, we show that boosted accuracy (AUC=0.959) is achieved on EAST predictions by including in the training only 20 disruptive discharges, thousands of non-disruptive discharges from EAST, and combining this with more than a thousand discharges from DIII-D and C-Mod. The improvement of predictive ability obtained by combining disruptive data from other devices is found to be true for all permutations of the three devices. Furthermore, by comparing the predictive performance of each individual numerical experiment, we find that non-disruptive data are machine-specific while disruptive data from multiple devices contain device-independent knowledge that can be used to inform predictions for disruptions occurring on a new device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization-based approaches to control of connected and automated vehicles: Principles, complexities, applications, challenges, and outlook

Safe and optimal motion control for connected and automated vehicles (CAVs) poses a fundamental optimization challenge at the intersection of system complexity, environmental uncertainty, and stringent real-time constraints. Existing surveys address this challenge in isolation – focusing either on specific control techniques or individual uncertainty sources – without providing a unified framework that characterizes the trade-offs among computational tractability, performance verifiability, and adaptive generalization across paradigms. This review addresses that gap by presenting a cohesive analytical framework concentrated on the decision-making and trajectory optimization layers of the CAV autonomy stack. We systematically analyze three major optimization paradigms – first-principles model-based optimization, data-driven methods, and hybrid synergistic architectures – evaluating each against four core complexity axes: problem formulation, constraint handling, optimality guarantees, and robustness. Key applications including platooning, trajectory planning, collision avoidance, and cooperative control are examined to reveal recurring methodological patterns and critical operational constraints that limit real-world performance. Our synthesis identifies verifiable hybrid architectures, incentive-aligned multi-agent cooperation, and hardware-algorithm co-design as the defining research frontiers, and distills a targeted agenda for developing CAV control systems that are simultaneously safe, computationally efficient, and deployable in the full complexity of real-world traffic environments.

Muzahid, Abu Jafar Md [University of Tennessee, Kn↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗

Optimal Control of the Energy-Saving Hybrid Hydraulic-Electric Architecture (HHEA) for Off-Highway Mobile Machines

Most off-highway constructions and agriculture equipment use hydraulics, which has unmatched power density, for power transmission and throttling as a means for control. A novel hybrid hydraulic-electric architecture (HHEA) has recently been proposed to improve efficiency for high-power machines that would have been cost-prohibitive to electrify directly. HHEA uses a set of common pressure rails (CPRs) to transmit the majority of power hydraulically and small electric motor drives to modulate that power and to achieve precise control. This article proposes a computationally efficient Lagrange multiplier method (LMM) for computing the optimal sequence of pressure rail selections to minimize energy use. This is needed to evaluate HHEA's energy-saving potential and for iterative architecture design and sizing. An interesting complication is that the cost function is not fully defined until the candidate control sequence is fully specified. This issue is dealt with by decomposing the original problem into a set of sub-problems with additional constraints that can be solved efficiently. Computational effort can be further reduced if actuators are optimized individually instead of together. However, additional steps are required to prevent the constraint functions from becoming discontinuous with respect to the Lagrange multipliers, which is necessary for meeting the constraints. Lastly, a case study of a construction machine demonstrates the efficacy of the method and shows that the HHEA reduces energy consumption by 68%-73% compared to the baseline load-sensing architecture.

Lagrange multiplier↗

Coherence-mediated quantum thermometry in a hybrid circuit quantum electrodynamics architecture

Quantum thermometry plays a critical role in the development of low-temperature sensors and quantum information platforms. Here, in this work, we propose and analyze a hybrid circuit quantum electrodynamics architecture in which a superconducting qubit is dispersively coupled to two distinct bosonic modes: one initialized in a weak coherent state as a phase reference and information buffer and the other coupled to a thermal environment. We show that the qubit serves as a sensitive readout of the probe mode, mapping the interplay between thermal and coherent photon-number fluctuations onto measurable dephasing. This coherence-mediated mechanism enables improved sensitivity to thermal energy fluctuations in the sub-millikelvin regime through Ramsey interferometry. We derive analytic expressions for the probe coherence envelope, compute the quantum Fisher information for temperature estimation, and demonstrate numerically that the presence of a coherent reference enhances the qubit's sensitivity to small changes in thermal photon occupancy. Our results establish a coherence-enabled approach to thermometry and provide a scalable platform for future calorimetric sensing in high-energy physics and quantum metrology.

Zhu, Shaojiang [Fermi National Accelerator Laborat↗

A Power Take-Off (PTO) for Wave Energy Converters Based on the Hybrid Hydraulic-Electric Architecture (HHEA)

Wave energy is a promising renewable energy resource for coastal regions around the world, but is not yet an economically competitive source of electricity. More effective power take-off (PTO) designs would help to make wave power a feasible and clean source of energy. To do this, PTOs need to: i) enable controlled actuation, ii) convert absorbed energy into electricity efficiently, and iii) have minimal manufacturing costs. We propose a new PTO architecture that can exert arbitrary control loads on the WEC to maximize energy capture, enabling the downsizing of expensive electrical components while maintaining high efficiency. Our PTO design is based upon a hybrid hydraulic-electric architecture (HHEA). This paper compares the performance of the HHEA PTO against two other PTO designs: 1) a baseline PTO consisting of a system of rectifying check valves and accumulators, and 2) a PTO consisting of an electro-hydraulic actuator (EHA). The HHEA PTO is shown to produce much more power than the check valve PTO and the EHA PTO. Also, the required electric generator sizes for the HHEA are smaller than that of the EHA PTO. The reduced size of these components allows for a WEC which is less expensive to manufacture.

16 TIDAL AND WAVE POWER↗

Co-Design of a Fully Electric Hybrid Hydraulic-Electric Architecture (FE-HHEA) for Off-Road Mobile Machines

Off-road mobile machines, such as excavators and wheel-loaders, are typically actuated by hydraulics using internal combustion engines as their power sources. There is a trend towards fully electrifying these machines and improving their efficiencies due to environmental regulations and concerns. In this paper, a control co-design methodology is used to design a Fully Electrified Hybrid Hydraulic-Electric Architecture (FE-HHEA) for an excavator that drastically reduces energy consumption and minimizes the sizes of costly electric components. By optimizing both control operation and the physical design, the co-design methodology takes into account the interaction between these two aspects. The design methodology also illustrates how the system architecture evolves from the previously developed IC engine powered HHEA with the engine replaced by an electric motor to a seemingly very different architecture with fewer components. The optimized system reduces energy consumption by 71% over the baseline system and uses electrical components that are 1/3 the size of an alternate fully electric architecture.

33 ADVANCED PROPULSION SYSTEMS↗

Porous potassium tantalate-reduced graphene oxide nano cube architecture for high performance hybrid supercapacitors

Energy storage has always been a major concern in the present-day situation. Advanced energy storage devices are batteries, supercapacitor and solar cells. However, advancements have been noteworthy in the field of high-performance hybrid supercapacitors. On this note, we have fabricated a hybrid supercapacitor electrode material Potassium tantalate nano cube (KT NCs) and its reduced graphene oxide composite (KT-rGO NCs) and tested its electrochemical performance. The materials showed high performances with specific capacitance of 565 F/g for KT NCs and 850 F/g for KT-rGO NCs respectively. Energy densities of both KT NCs & KT-rGO NCs are 28.24 Wh/Kg and 29.50 Wh/kg with good retention capacities. Further detailed study of both KT NCs and KT-rGO NCs are carried out with characterization techniques like XRD, FTIR, BET, Raman and HRTEM for structural analysis and electrochemical measurements to analyse various parameters pertaining to its charge storage capacity.

36 MATERIALS SCIENCE↗

AC and DC Hybrid Distribution Grids with Solar Integration: Architecture, Stabilization and Cost Assessment

In this project, a holistic analysis of architecture, stabilization, and cost/efficiency analysis in hybrid AC and DC distribution grids are conducted. Particularly, versatile and cost-efficient multiport converters are developed to not only integrate solar sources and other DERs in DC grids, but also facilitate the interactive operation of DC sub-grids and conventional AC distribution grids. Meanwhile, a universal and extended impedance-based stabilization approach with a decentralized and adaptive virtual impedance loop is developed in hybrid AC and DC distribution grids, which comprehensively covers the active stabilization of DC sections, AC sections, and interface inverters interlinking both AC and DC sections. Furthermore, to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and quantify the improvement of hybrid AC and DC grids over conventional pure AC grids, the project team develops an alpha-version tool to monitor and calculate the efficiency and cost of the DC, AC, or hybrid AC and DC grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗