Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen storage systems,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Hydrogen underground storage for grid electricity storage: An optimization study on techno-economic analysis

Here, this study performs a techno-economic analysis of hydrogen underground storage systems for grid electricity storage, evaluating their economic viability at the plant scale using dynamic optimization. It explores the feasibility of various system configurations and revenue models in the context of volatile electricity prices and the necessity for multiple revenue streams. The hypothesis tested is that large-scale hydrogen storage, despite its low round-trip efficiency, can be economically viable with the right mix of revenue streams. This study uses scenario-based analysis to assess the impacts of different system configurations, including engaging in time-shifting arbitrage, ancillary service markets and blending hydrogen with natural gas. Results indicate potential annual net cash flows of up to $\$$1.5 million from ancillary services integration and $\$$5.2 million from natural gas blending, contingent on specific system sizes. The study concludes that hydrogen underground storage for grid electricity storage can be profitable, and emphasizes that proper system design and precise electricity price forecasting are crucial for optimizing system performance and economic returns. This research sets the stage for further investigations into the scalability of hydrogen storage systems and their broader implications for grid electricity storage and energy market dynamics.

25 ENERGY STORAGE↗

Clemson Hydrogen Combined Heat and Power Storage System

The objective of this project named H2 Orange, was to develop a conceptual design including a technoeconomic study, technology gap assessment and maturation plan, and commercialization plan of a nominal 50-megawatt hours (MWh) hydrogen energy storage system. The project investigated how to optimally size, design and integrate the hydrogen energy storage system with an existing 14.3-megawatt (MW) gas turbine fossil asset supplying thermal power at the Clemson University Combined Heat & Power (CHP) plant.

03 NATURAL GAS↗

A High Temperature Gas Reactor Integrated Energy System Using Energy Storage as a Buffer for Hydrogen Production

Analysis of an integrated energy system producing hydrogen in a high temperature steam electrolysis system via steam provided by a sensible heat thermal energy storage system charged by a high temperature gas reactor. Preliminary results over a continuous discharge cycle and single charging cycle shows minimal reactor impact despite 25% electrical power load change. Hydrogen production is held constant with steam provided by the thermal energy storage system.

08 HYDROGEN↗

Reversible Solid Oxide Fuel Cell Systems for Energy Storage and Hydrogen Production

FuelCell Energy (FCE) studied the performance, design, and economics of a reversible solid-oxide fuel cell/electrolyzer integrated with a natural gas-based electricity generation plant and used as an energy storage system. Increased market penetration of renewable energy is challenging for operators of fossilbased plants which are not suited for quick turndown and ramp-up. Process simulations studies show that with utilization of waste heat from the power plant, a high roundtrip efficiency (RTE) around 70% is possible, providing excellent market potential for this energy storage technology, potentially providing improved economics and lifetime for such power plant. The market potential and economics as a function of production volume are analyzed in detail. FCE is continuing the development and commercialization of its solid oxide technology.

08 HYDROGEN↗

Hydroelectric Power and Hydrogen Production Integration

Hydropower-based hydrogen production could introduce opportunities for new revenue streams for hydropower plants, including from energy storage and regeneration as well as from sale of the hydrogen product to external markets. Hydrogen-based energy storage and regeneration could also help support Idaho Power’s decarbonization goals by decreasing dependence on fossil-based peaking power plants. Additionally, integration of hydrogen production with hydropower generation could help address the issue of low dissolved oxygen river water conditions that commonly accompany hydropower plant operations by utilizing the oxygen byproduct from an electrolytic hydrogen production process as a resource for mitigation of low dissolved oxygen water conditions. Comprehensive techno-economic analysis of the hybrid hydroelectric and hydrogen energy storage system has revealed critical insights into the pathways and considerations for optimizing the economic value and environmental benefits of such systems. Among the three identified pathways of natural gas blending, regeneration, and direct sale of hydrogen, the direct sale of hydrogen emerges as the most profitable, particularly given the current pricing dynamics of hydrogen and electricity. However, as we anticipate a future grid characterized by higher renewable energy penetration, the landscape may evolve, featuring lower average electricity prices, heightened fluctuations, and more significant seasonal variations. Consequently, the attractiveness of electricity regeneration through hydrogen and the benefits of long-duration hydrogen storage are expected to increase substantially in such a dynamic energy scenario. The careful selection of component sizes within the hybrid system proves to be paramount for ensuring cost-effectiveness. Notably, the size of the hydrogen market has emerged as a critical determinant for the optimal size of the electrolyzer. Hydrogen storage should be sized to meet energy shifting requirements. The appropriate size of the fuel cell/microturbine generator hinges on the shape of electricity prices and the available revenue streams derived from participating in grid services. Striking the right balance among these components is essential for maximizing the overall efficiency and profitability of the hydrogen facility. Furthermore, the by-product of electrolysis, namely oxygen, introduces an additional dimension to the system's functionality. The oxygen generated can be effectively utilized for dissolved oxygen (DO) mitigation, particularly with larger electrolyzer sizes capable of satisfying the complete oxygen demand for this purpose. While the economic benefits derived from saved oxygen purchase costs may be relatively modest compared to other revenue streams, the environmental advantages of repurposing oxygen for DO mitigation could help Idaho Power meet their environmental obligations. In addition to the identified factors shaping the viability of hybrid hydrogen production and hydroelectric generation, it is noteworthy that the integration of hydrogen energy storage offers a unique advantage during unusually wet years. In such periods of increased water inflow, the hydrogen storage capacity serves as a valuable supplement to the reservoir. By utilizing hydrogen energy storage as a complementary reservoir, the system gains flexibility in reservoir management when dealing with fluctuations in water availability.

08 HYDROGEN↗

Ternary borides and borohydrides for hydrogen storage and method of synthesis

A method and a system is provided for obtaining solid-state hydrogen storage and release in materials with at least theoretical loaded hydrogen densities of 11 wt % or greater that can deliver hydrogen and be recharged at moderate temperatures enabling incorporation into hydrogen storage systems suitable for transportation applications. These materials comprise ternary boride materials comprising certain light transition metals and alkaline or alkaline earth metals, and ideally have no or very little phase separation. A process of making these materials is also provided.

Stavila, Vitalie↗

A Bulk versus Nanoscale Hydrogen Storage Paradox Revealed by Material-System Co-Design

Metal hydrides are serious contenders for materials-based hydrogen storage to overcome constraints associated with compressed or liquefied H 2 . Their ultimate performance is usually evaluated using intrinsic material properties without considering a systems design perspective. An illustrative case with startling implications is (LiNH 2 +2LiH). Using models that simulate the storage system and associated fuel cell of a light-duty vehicle (LDV), the performance of the bulk hydrides is compared with a nanoscaled version in porous carbon (PC), (LiNH 2 +2LiH)@(6-nm PC). Using experimental material properties, the simulations show that (LiNH 2 +2LiH)@(6-nm PC) counterintuitively has higher usable gravimetric and volumetric capacities than the bulk counterpart on a system basis despite having lower capacities on a materials-only basis. Nanoscaling increases the thermal conductivity and lowers the desorption enthalpy, which consequently increases heat management efficiency. In a simulated drive cycle for fuel cell-powered LDV, the fuel cell is inoperable using bulk (LiNH 2 +2LiH) as the storage material but completes the drive cycle using the nanoscale material. Further, these results challenge the notion that nanoscaling incurs mass and volume penalties. Instead, the synergistic nanoporous host-hydride interaction can favorably modulate chemical and heat transfer properties. Moreover, a co-design approach considering application-specific tradeoffs is essential to accurately assess a material's potential for real-world hydrogen storage.

08 HYDROGEN↗

H-2-SALT: Storing Fossil Energy as Hydrogen in Salt Caverns

Hydrogen storage in subsurface caverns is known as perhaps largest and longest-term energy storage system. While few such systems are currently in service (e.g., Texas; Teesside, UK), they are envisioned as being a pillar of the current energy transition that will allow intermittent power production from renewable sources (e.g., wind, solar) to be balanced with demand at grid-scale. In addition, hydrogen energy storage can allow existing fossil power plants to run more economically either by minimizing startups/shutdowns or by allowing them to take advantage of arbitrage. Finally, stored hydrogen can feed a variety of non-power users such as pipeline gas, heating, transportation, and manufacturing. The H-2-SALT paper study assessed the feasibility of a power-to-hydrogen system utilizing salt cavern storage of hydrogen in bedded salt in central Kansas, where over 750 such caverns have been constructed to date, of which approximately 350 are still in service. Legacy well and salt cavern data were collected to develop a regional geological database for two sites in Central Kansas and adjacent areas for use in more detailed geological and geomechanical site characterization efforts. This study found commercial viability and competitiveness of large-scale, electrolytic H 2 production and storage ($1.78 per kg H 2 ) that can be used for both electrical power supply to the grid during high-priced electricity periods (including co-firing with NG and fuel cell power production) and sale of H 2 for various industries, such as petrochemicals or transportation. The commercial potential of the H-2-SALT system is also relatively high because each of its components operate commercially today. It is recommended that a stratigraphic test well be drilled to collect log data and core samples that can reduce uncertainty surrounding geological and geomechanical properties of the salt beds that will be required for further cavern and energy storage system design studies.

03 NATURAL GAS↗

A nuclear-hydrogen hybrid energy system with large-scale storage: A study in optimal dispatch and economic performance in a real-world market

Here a study in optimal dispatch and economic analysis of a novel nuclear hybrid energy system (NHES) with large-scale hydrogen storage and a novel control scheme is conducted. The control scheme makes charge and discharge decisions by using the real-time electricity price relative to the historical price distribution. The pricing data is taken from the ERCOT Houston and West load zones with different price oscillations. Six case control studies with different levels of aggressiveness were chosen for each load zone for a total of 12 case studies. It is found that in a high price volatility load zone, a more aggressive control strategy maximizes revenue, while in a less oscillatory load zone, a moderate control strategy performs better. The NHES can store energy when the price is low and sell additional electricity when the price is high, as well as participate in the ancillary services market. Due to these advantages, the NHES can generate 10–40 million USD more revenue annually than a stand-alone nuclear plant. Due to higher costs, the NHES has a higher LCOE (81.36 USD/MWh) than a stand-alone plant (68.66 USD/MWh); however, the LCOE of the NHES is still comparable to other new forms of electricity generation. It is found that both the NHES and the stand-alone plant are not economical in the existing electricity market. Due to the extra revenue generated, the hybrid system has a positive annual cashflow whereas the stand-alone plant does not. It is found that the hybrid plant needs less cost subsidy than a stand-alone plant to become economical.

08 HYDROGEN↗

Thermodynamic parametric analysis of refueling heavy-duty hydrogen fuel-cell electric vehicles

Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. Here, we studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.

08 HYDROGEN↗

Broad range material-to-system screening of metal–organic frameworks for hydrogen storage using machine learning

Hydrogen is pivotal in the transition to sustainable energy systems, playing major roles in power generation and industrial applications. Metal–organic frameworks (MOFs) have emerged as promising mediums for efficient hydrogen storage. However, identifying potential candidates for deployment is challenging due to the vast number of currently available synthesized MOFs. This study integrates molecular simulations, machine learning, and techno-economic analysis to evaluate the performance of MOFs across broad operation conditions for hydrogen storage applications. While previous screenings of MOF databases have predominantly emphasized high hydrogen capacities under cryogenic conditions, this study reveals that optimal temperatures and pressures for cost minimization depend on the raw price of the MOF. Specifically, when MOFs are priced at $15/kg, among the 9720 MOFs tested, 9692 MOFs achieve the lowest cost at temperatures between 170 K and 250 K and a pressure of 150 bar. Under these optimal conditions, 362 MOFs deliver a lower levelized cost of storage than 350 bar compressed gas hydrogen storage. Furthermore, this study reveals key material properties that result in low system cost, such as high surface areas (>3000 m2/g), large void fractions (>0.78), and large pore volumes (>1.1 cm3/g).

Hydrogen storage↗

Analysis of Multi-Output Hybrid Energy Systems Interacting with the Grid: Application of Improved Price-Taker and Price-Maker Approaches to Nuclear-Hydrogen Systems

The growing recognition of the value of hydrogen as an energy intermediate in supporting future power systems with high shares of variable renewable energy has prompted many studies to quantify the economic potential of multi-output hybrid systems, which are one type of integrated energy systems (IES). Because of the complexity of modeling multiple sectors, these studies typically use simplified modeling approaches to capture the interactions between sectors. In this study, we explore the implications of alternative modeling approaches for nuclear-hydrogen IES focusing on a power system in the Midwest United States. We combine highly resolved capacity expansion and production cost modeling tools of the power system with a detailed hydrogen system optimization tool to determine the optimal electrolyzer and storage sizing and optimal operations of the nuclear-hydrogen hybrid resource across three future study years. We compare economic and operational outcomes across a spectrum of modeling approaches, including a non-hybridized base approach; a traditional price-taker approach that does not include the impact of hydrogen production on the electricity system; a power-system-focused price-maker approach that does not account for temporal hydrogen constraints; and two improved price-taker and price-maker approaches that each address the impact of revenue-optimal levels of electricity production on the resulting power system and temporal hydrogen constraints on the overall feasible solution. Results show how a traditional price-taker approach can overestimate the economic benefits of multi-output nuclear-hydrogen IES compared to our two improved approaches that estimate both hydrogen system constraints and power system interaction. We find that hydrogen output requirements and storage size limits are key drivers to overall operations and some economic outcomes. Under our assumed constant hydrogen output requirement, storage costs, test system, and modeling approaches, our results indicate that hybridization can provide a net benefit, but results are sensitive to the treatment of hydrogen revenues and electricity prices as impacted by the power system evolution.

capacity expansion modeling↗

Coupled diffusion-deformation-damage model for polymers used in hydrogen infrastructure

The soft materials used in the infrastructure of hydrogen storage and distribution systems are vulnerable because exposure to high-pressure hydrogen can lead to mechanical damage and property degradation. Some materials, such as polymers, can undergo mechanical failure due to a phenomenon wherein hydrogen gas diffuses through the polymer chains and occupies preexisting cavities or voids inside the polymer material. If the hydrogen gas pressure is reduced more quickly than hydrogen can diffuse back out of the polymer which is necessary for some applications, the trapped hydrogen gas instead escapes by rupturing the material, causing surface blistering or permanent damage. In this study, a continuum mechanics-based fully coupled diffusion-deformation model with damage is developed to predict the stress distribution and damage propagation while the polymer undergoes rapid decompression failure. The hyperelastic material model, along with the maximum principal strain failure theory, was chosen for this study as it represents the nonlinear material response with brittle failure observed in uniaxial tensile tests perfectly. EPDM polymer was chosen for this study because of its commercial availability and common use in hydrogen storage and distribution system. It has superior mechanical properties, high and low temperature resistance, and certain compounds work well in hydrogen gas. This work is useful for design engineers to alter the parameters while manufacturing polymer composites to increase their performance in a high-pressure hydrogen environment.

Kulkarni, Shank S.↗

Review of Shock, Vibration, and Other Tests for Type IV Hydrogen Composite Pressure Vessels for Rail Use

Requirements specific to hydrogen rail transportation and its unique components are currently not well represented in safety codes and standards. Notably, one of the most important components of the system, the hydrogen storage vessel, may be subject to entirely different shock and vibration conditions compared to hydrogen tanks on road vehicles. This report focuses on how composite hydrogen tanks are tested for performance and how this may relate to these tanks being used on rail systems. The shock and vibration testing procedures that are relevant for hydrogen composite tanks used for rail applications have been identified, as well as some general testing requirements for hydrogen tanks and composite tanks.

42 ENGINEERING↗

Influence of near-surface oxide layers on TiFe hydrogenation: mechanistic insights and implications for hydrogen storage applications

The inevitable formation of passivating oxide films on the surface of the TiFe intermetallic compound limits its performance as a stationary hydrogen storage material. Extensive experimental efforts have been dedicated to the activation of TiFe, i.e. oxide layer removal prior to utilization for hydrogen storage. However, development of an efficient activation protocol necessitates a fundamental understanding of the composition and structure of the air-exposed surface and its interaction with hydrogen, which is currently absent. Therefore, in this study we explored the growth and nature of oxide films on the most exposed TiFe surface (110) in depth using static and dynamic first-principles methods. We identified the lowest energy structures for six oxygen coverages up to approximately 1.12 nm of thickness with a global optimization method and studied the temperature effects and structural evolution of the oxide phases in detail via ab initio molecular dynamics (AIMD). Based on structural similarity and coordination analysis, motifs for TiO 2 and TiFeO 3 as well as Ti(FeO 2 ) x (x = 2, 3 or 5) phases were identified. On evaluating the interaction of the oxidized surface with hydrogen, a minimal energy barrier of 0.172 eV was predicted for H 2 dissociation while H migration from the top of the oxidized surface to the bulk TiFe was limited by several high-lying energy barriers above 1.4 eV. Our mechanistic insights will prove themselves valuable for informed designs towards new activation methods of TiFe and related systems as hydrogen storage materials.

08 HYDROGEN↗