Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Precision segmented reflector, figure verification sensor

The Precision Segmented Reflector (PSR) program currently under way at the Jet Propulsion Laboratory is a test bed and technology demonstration program designed to develop and study the structural and material technologies required for lightweight, precision segmented reflectors. A Figure Verification Sensor (FVS) which is designed to monitor the active control system of the segments is described, a best fit surface is defined, and an image or wavefront quality of the assembled array of reflecting panels is assessed

Manhart, Paul K.↗

Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration

Purpose: lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. Methods and Materials: 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Results: Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods <0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of 'shape differences' was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. Conclusions: We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extrusion parameter control optimization for DIW 3D printing using image analysis techniques

Material extrusion is a well-recognized facet of additive manufacturing that involves the fabrication of parts through the deposition of structural material from an extrusion head from a bulk supply. In the subdivision of Direct Ink Writing (DIW) additive manufacturing, challenges arise when the structural material is flowable, synchronous extrusion control and tool movement becomes critical for achieving high-quality parts with low defect populations. DIW techniques are most used in laboratory settings using expensive custom instruments and may require specialized 3D slicing software. Here, in this study, the fabrication of an inexpensive, consumer-friendly progressive cavity pump dispensing system is detailed, in which can create high-quality parts by executing G-code commands produced from a commercial slicing software. The precision and repeatability of the movement-synchronized material extrusion is demonstrated through a series of optimization schemes, entailing the alteration of various control parameters, which directly affect the extrusion properties demonstrated during a print. In situ diagnostics were implemented to evaluate the results of the established optimization experiment. Using a machine vision technique, images of the optimization prints are processed. Following this, a supervised machine learning model was trained to autonomously judge whether or not the extrusion parameters produced a passing or failing result. The machine learning scheme serves as a preliminary benchmark for future layer-by-layer evaluation of more complex DIW parts. The construction of the printer and development of in situ characterization capabilities demonstrates the ability for this printer to create high-fidelity DIW parts for a fraction of the price of other systems.

42 ENGINEERING↗

Real-time 3D analysis during electron tomography using tomviz

The demand for high-throughput electron tomography is rapidly increasing in biological and material sciences. However, this 3D imaging technique is computationally bottlenecked by alignment and reconstruction which runs from hours to days. We demonstrate real-time tomography with dynamic 3D tomographic visualization to enable rapid interpretation of specimen structure immediately as data is collected on an electron microscope. Using geometrically complex chiral nanoparticles, we show volumetric interpretation can begin in less than 10 minutes and a high-quality tomogram is available within 30 minutes. Real-time tomography is integrated into tomviz, an open-source and cross-platform 3D data analysis tool that contains intuitive graphical user interfaces (GUI), to enable any scientist to characterize biological and material structure in 3D.

36 MATERIALS SCIENCE↗

Morphology of Nano and Micro Fiber Structures in Ultrafine Particles Filtration

Selected procedures permitting to prepare homogeneous nanofibre structures of the desired morphology by employing a suitable combination of variables during the electrospinning process are presented. A comparison (at the same pressure drop) was made of filtration capabilities of planar polyurethane nanostructures formed exclusively by nanofibres, space polycarbonate nanostructures having bead spacers, structures formed by a combination of polymethyl methacrylate micro- and nanofibres and polypropylene meltblown microstructures, through which ultrafine particles of ammonium sulphate 20-400 nm in size were filtered. The structures studied were described using a new digital image analysis technique based on black and white images obtained by scanning electron microscopy. More voluminous structures modified with distance microspheres and having a greater thickness and mass per square area of the material, i.e. structures possessing better mechanical properties, demanded so much in nanostructures, enable preparation of filters having approximately the same free volume fraction as flat nanofibre filters but an increased effective fibre surface area, changed pore size morphology and, consequently, a higher filter quality.

36 MATERIALS SCIENCE↗

Nondestructive Modular Leak Detection in 3D Printed 316L Stainless Steel Pipes via Laser Powder Bed Fusion

This research investigates the leak detection features of 316L Stainless Steel pipe structures manufactured via Laser Powder Bed Fusion (LPBF). This work involves the design of a modular sensor system integrating nondestructive evaluation (NDE) methods, including thermal imaging and ultrasonic frequency detection to detect and characterize leaks in components. This aims to improve leak detection sensitivity within medium-pressure gas systems, during continuous operation without halting flow or introducing safety risks. The system could be adaptable for use on unmanned aerial vehicles (UAVs), enabling remote leak detection in active environments. A custom pneumatic system incorporating temperature and pressure sensors was assembled to detect leaks in LPBF-printed 316L SS tee pipes. Experimental results and simulations confirm the system’s effectiveness in leak detection and material evaluation. This research program also integrated a Python-based image recognition platform based on a metallography and optical microscopy to assess the porosity and complement the leak detection data on the printed structures. This allows a detailed analysis of pore distribution and internal leak paths, which could compromise structural integrity, critical for quality control during manufacturing. Findings suggest that the investigated approach holds potential for enhancing leak detection technologies and adapt them for advanced manufactured parts.

36 MATERIALS SCIENCE↗

Following Dynamic Processes by X-ray Tomographic Microscopy with Sub-second Temporal Resolution

Several non-destructive imaging techniques offer the possibility to observe rapid phenomena in real time, yet most of these techniques fail when it comes to bulky samples and micrometer precision in three dimensions. Therefore there is clearly a need to develop approaches that address such conditions. We identified the large potential that lies in synchrotron-based x-rays as a probe and developed a direct-space tomographic instrument suitable to provide sub-second temporal resolution with several-micrometers spatial resolution. Selected applications from the field of biology and material science are shown in order to demonstrate the unique capabilities in generating three-dimensional images with very high quality making image segmentation and analysis possible for samples that could, until now, only be studied in two dimensions due to the occurrence of rapid structural changes.

07 ISOTOPE AND RADIATION SOURCES↗

Atomic layer epitaxy of kagome magnet Fe 3 Sn 2 and Sn-modulated heterostructures

Magnetic materials with kagome crystal structure exhibit rich physics, such as frustrated magnetism, skyrmion formation, topological flat bands, and Dirac/Weyl points. Until recently, most studies on kagome magnets have been performed on bulk crystals or polycrystalline films. Here, we report the atomic layer molecular beam epitaxy synthesis of high-quality thin films of topological kagome magnet Fe 3 Sn 2 . The structural and magnetic characterization of Fe 3 Sn 2 on epitaxial Pt(111) identifies highly ordered films with c-plane orientation and an in-plane magnetic easy axis. Studies on the local magnetic structure by anomalous Nernst effect imaging reveal in-plane oriented micrometer size domains. Superlattice structures consisting of Fe 3 Sn 2 and Fe 3 Sn are also synthesized by atomic layer molecular beam epitaxy, demonstrating the ability to modulate the sample structure at the atomic level. The realization of high-quality films by atomic layer molecular beam epitaxy opens the door to explore the rich physics of this system and investigate novel spintronic phenomena by interfacing Fe 3 Sn 2 with other materials.

36 MATERIALS SCIENCE↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗

Technical Note: Rapid prototyping of 3D grid arrays for image guided therapy quality assurance

Three dimensional grid phantoms offer a number of advantages for measuring imaging related spatial inaccuracies for image guided surgery and radiotherapy. The authors examined the use of rapid prototyping technology for directly fabricating 3D grid phantoms from CAD drawings. We tested three different fabrication process materials, photopolymer jet with acrylic resin (PJ/AR), selective laser sintering with polyamide (SLS/P), and fused deposition modeling with acrylonitrile butadiene styrene (FDM/ABS). The test objects consisted of rectangular arrays of control points formed by the intersections of posts and struts (2 mm rectangular cross section) and spaced 8 mm apart in the x, y, and z directions. The PJ/AR phantom expanded after immersion in water which resulted in permanent warping of the structure. The surface of the FDM/ABS grid exhibited a regular pattern of depressions and ridges from the extrusion process. SLS/P showed the best combination of build accuracy, surface finish, and stability. Based on these findings, a grid phantom for assessing machine-dependent and frame-induced MR spatial distortions was fabricated to be used for quality assurance in stereotactic neurosurgical and radiotherapy procedures. The spatial uniformity of the SLS/P grid control point array was determined by CT imaging (0.6x0.6x0.625 mm{sup 3} resolution) and found suitable for the application, with over 97.5% of the control points located within 0.3 mm of the position specified in CAD drawing and none of the points off by more than 0.4 mm. Rapid prototyping is a flexible and cost effective alternative for development of customized grid phantoms for medical physics quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Steps toward eight-meter honeycomb mirror blanks. I Rationale and approach

The best form for 8-m telescope mirrors is discussed. It is concluded that honeycomb sandwich structure can meet the most exacting demand goals for subarcsecond image quality in optical and infrared astronomy. These structures are light, have good stiffness against gravitational and wind loading, and have low thermal inertia. The latter permits them to be operated at the ambient air temperature to avoid local seeing problems. Borosilicate and aluminosilicate glasses are adequate materials for ventilated honeycombs, which do not require low expansion materials.

Angel, J. R. P.↗

Neutron Imaging of Al6061 Prepared by Solid-State Friction Stir Additive Manufacturing

Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD ® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.

36 MATERIALS SCIENCE↗

Deep Learning for Semantic Segmentation of Defects in Advanced STEM Images of Steels

Crystalline materials exhibit long-range ordered lattice unit, within which resides nonperiodic structural features called defects. These crystallographic defects play a vital role in determining the physical and mechanical properties of a wide range of material systems. While computer vision has demonstrated success in recognizing feature patterns in images with well defined contrast, automated identification of nanometer scale crystallographic defects in electron micrographs governed by complex contrast mechanism is still a challenging task. Here, building upon an advanced defect imaging mode that offers high feature clarity, we introduce DefectSegNet - a new convolutional neural network (CNN) architecture that performs semantic segmentation of three common crystallographic defects in structural alloys: dislocation lines, precipitates and voids. Results from supervised training of a small set of high-quality defect images of steels show high pixel-wise accuracy across all three types of defects: 91.60 ± 1.77% on dislocations, 93.39 ± 1.00% on precipitates, and 98.85 ± 0.56% on voids. We discuss the sources of uncertainties in CNN prediction, and the training data in terms of feature density, representation and homogeneity and their effects on deep learning performance. Further defect quantification using DefectSegNet prediction outperforms human expert average, presenting a promising new workflow for fast and statistically meaningful quantification of materials defects.

36 MATERIALS SCIENCE↗

Real-Time Diagnostics of 2D Crystal Transformations by Pulsed Laser Deposition: Controlled Synthesis of Janus WSSe Monolayers and Alloys

Energetic processing methods such as hyperthermal implantation hold special promise to achieve the precision synthesis of metastable two-dimensional (2D) materials such as Janus monolayers; however, they require precise control. Here, we report a feedback approach to reveal and control the transformation pathways in materials synthesis by pulsed laser deposition (PLD) and apply it to investigate the transformation kinetics of monolayer WS 2 crystals into Janus WSSe and WSe 2 by implantation of Se clusters with different maximum kinetic energies (<42 eV/Se-atom) generated by laser ablation of a Se target. Real-time Raman spectroscopy and photoluminescence are used to assess the structure, composition, and optoelectronic quality of the monolayer crystal as it is implanted with well-controlled fluxes of selenium for different kinetic energies that are regulated with in situ ICCD imaging, ion probe, and spectroscopy diagnostics. First-principles calculations, XPS, and atomic-resolution HAADF STEM imaging are used to understand the intermediate alloy compositions and their vibrational modes to identify transformation pathways. The real-time kinetics measurements reveal highly selective top-layer conversion as WS 2 transforms through WS 2(1–x) Se 2x alloys to WSe 2 and provide the means to adjust processing conditions to achieve fractional and complete Janus WSSe monolayers as metastable transition states. The general approach demonstrates a real-time feedback method to achieve Janus layers or other metastable alloys of the desired composition, and a general means to adjust the structure and quality of materials grown by PLD, addressing priority research directions for precision synthesis with real-time adaptive control.

2D materials↗

Atomic Resolution Imaging of Halide Perovskites

The radiation-sensitive nature of halide perovskites has hindered structural studies at the atomic scale. We overcome this obstacle by applying low dose-rate in-line holography, which combines aberration-corrected high-resolution transmission electron microscopy with exit-wave reconstruction. This technique successfully yields the genuine atomic structure of ultrathin two-dimensional CsPbBr 3 halide perovskites, and a quantitative structure determination was achieved atom column by atom column using the phase information of the reconstructed exit-wave function without causing electron beam-induced sample alterations. An extraordinarily high image quality enables an unambiguous structural analysis of coexisting high-temperature and low-temperature phases of CsPbBr 3 in single particles. On a broader level, our approach offers unprecedented opportunities to better understand halide perovskites at the atomic level as well as other radiation-sensitive materials.

36 MATERIALS SCIENCE↗

Mending cracks atom-by-atom in rutile TiO2 with electron beam radiolysis

Abstract Rich electron-matter interactions fundamentally enable electron probe studies of materials such as scanning transmission electron microscopy (STEM). Inelastic interactions often result in structural modifications of the material, ultimately limiting the quality of electron probe measurements. However, atomistic mechanisms of inelastic-scattering-driven transformations are difficult to characterize. Here, we report direct visualization of radiolysis-driven restructuring of rutile TiO 2 under electron beam irradiation. Using annular dark field imaging and electron energy-loss spectroscopy signals, STEM probes revealed the progressive filling of atomically sharp nanometer-wide cracks with striking atomic resolution detail. STEM probes of varying beam energy and precisely controlled electron dose were found to constructively restructure rutile TiO 2 according to a quantified radiolytic mechanism. Based on direct experimental observation, a “two-step rolling” model of mobile octahedral building blocks enabling radiolysis-driven atomic migration is introduced. Such controlled electron beam-induced radiolytic restructuring can be used to engineer novel nanostructures atom-by-atom.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase-change Reconfigurable Optical WavEfront Synthesis System (PROWESS)

We report the design, fabrication, and testing of electrically tunable metasurface k-space filters based on the low-loss, high-contrast phase-change material GSST and a transparent Si electrode heating architecture. A 10x10 array of PCM elements integrated with Si heaters was fabricated via foundry processes, and used to actively control the crystallinity of a metasurface consisting of GSST nano antennae. By selectively varying the structural state of individual PCM elements, specific k-vectors of transmitted light can effectively be filtered out, resulting in improved imaging quality by reducing the scattered light that reaches a detector. Optimized doping profiles in the Si heaters allow for uniform, low power, reliable and repeatable switching of the GSST state. Compared to other k-space filters, this new architecture is completely transparent to the wavelength of interest and can be actively reconfigured in real time with high performance, low power consumption and a small footprint. The 10x10 array device is a proof-of-concept demonstration that can enable high-resolution arbitrary wavefront synthesis and correction in the future, with key applications in optical communications, beam steering, remote sensing, and adaptive optics.

phase change material↗

Dosimetry of an In-Line Kilovoltage Imaging System and Implementation in Treatment Planning

Purpose: To present the beam properties of the Siemens 70-kV and 121-kV linear accelerator-mounted imaging modalities and commissioning of the 121-kV beam in the Philips Pinnacle treatment planning system (TPS); measurements in an Alderson phantom were performed for verification of the model and to estimate the cone-beam CT (CBCT) imaging dose in the head and neck, thorax, and pelvis. Methods and Materials: The beam profiles and depth–dose curve were measured in an acrylic phantom using thermoluminescent dosimeters and a soft x-ray ionization chamber. Measurements were imported into the TPS, modeled, and verified by phantom measurements. Results: Modeling of the profiles and the depth–dose curve can be achieved with good quality. Comparison with the measurements in the Alderson phantom is generally good; only very close to bony structures is the dose underestimated by the TPS. For a 200° arc CBCT of the head and neck, a maximum dose of 7 mGy is measured; the thorax and pelvis 360° CBCTs give doses of 4-10 mGy and 7-15 mGy, respectively. Conclusions: Dosimetric characteristics of the Siemens kVision imaging modalities are presented and modeled in the Pinnacle TPS. Thermoluminescent dosimeter measurements in the Alderson phantom agree well with the calculated TPS dose, validating the model and providing an estimate of the imaging dose for different protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗