Search NASA⌕ Search

SEARCH · Search NASA

Results for “imagers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Integrative Quantitative-Phase and Airy Light-Sheet Imaging

Light-sheet microscopy enables considerable speed and phototoxicity gains, while quantitative-phase imaging confers label-free organelle recognition and metabolic information that are inaccessible by conventional methods. We report the fusion of these two modalities onto a standard inverted microscope that retains compatibility with microfluidics. We describe the utilization of an accelerating Airy-beam light-sheet yielding identical imaging areas with interferometry, and an application in unmasking the effects of cellular noise on metabolic compartmentalization.

Biological sciences, Biological techniques, Micros↗

Simulating image coaddition with the Nancy Grace Roman Space Telescope – II. Analysis of the simulated images and implications for weak lensing

One challenge for applying current weak lensing analysis tools to the Nancy Grace Roman Space Telescope is that individual images will be undersampled. Our companion paper presented an initial application of Imcom – an algorithm that builds an optimal mapping from input to output pixels to reconstruct a fully sampled combined image – on the Roman image simulations. In this paper, we measure the output noise power spectra, identify the sources of the major features in the power spectra, and show that simple analytic models that ignore sampling effects underestimate the power spectra of the coadded noise images. We compute the moments of both idealized injected stars and fully simulated stars in the coadded images, and their one- and two-point statistics. We show that the idealized injected stars have root-mean-square ellipticity errors (1–6) × 10 -4 per component depending on the band; the correlation functions are ≥2 orders of magnitude below requirements, indicating that the image combination step itself is using a small fraction of the overall Roman second moment error budget, although the fourth moments are larger and warrant further investigation. The stars in the simulated sky images, which include blending and chromaticity effects, have correlation functions near the requirement level (and below the requirement level in a wide-band image constructed by stacking all four filters). We evaluate the noise-induced biases in the ellipticities of injected stars, and explain the resulting trends with an analytical model. We conclude by enumerating the next steps in developing an image coaddition pipeline for Roman.

79 ASTRONOMY AND ASTROPHYSICS↗

Source shape estimation for neutron imaging systems using convolutional neural networks

Neutron imaging systems are important diagnostic tools for characterizing the physics of inertial confinement fusion reactions at the National Ignition Facility (NIF). In particular, neutron images give diagnostic information on the size, symmetry, and shape of the fusion hot spot and surrounding cold fuel. Images are formed via collection of neutron flux from the source using a system of aperture arrays and scintillator-based detectors. Currently, reconstruction of fusion source geometry from the collected neutron images is accomplished by solving a computationally intensive maximum likelihood estimation problem via expectation maximization. In contrast, it is often useful to have simple representations of the overall source geometry that can be computed quickly. In this work, we develop convolutional neural networks (CNNs) to reconstruct the outer contours of simple source geometries. We compare the performance of the CNN for penumbral and pinhole data and provide experimental demonstrations of our methods on both non-noisy and noisy data.

Machine learning, neutron imaging, source reconstr↗

Design and demonstration of a low‐field magnetic resonance imaging rhizotron for in‐field imaging of energy sorghum roots

Abstract Root phenotyping provides critical information to plant breeders for developing varieties with improved drought tolerance, greater root biomass, and greater nutrient use efficiency. Phenotyping roots in the natural environment is important for understanding the effect of the soil environment on root genotypic expressions. The goal of this work was to design and test a field‐scale mobile low‐field magnetic resonance imaging (LF‐MRI) Rhizotron that produces actionable root phenotyping data. We demonstrated this novel technology for root visualization and quantification using a LF‐MRI Rhizotron operating at 47 mT with two soil types. The LF‐MRI Rhizotron weights 453 kg, with a height of 90 cm, a diameter of 28 cm and an imaging field of view of 28 cm × 28 cm. The unit was operated in a Belk clay (Entic Hapluderts) and Weswood silt loam (Udifluventic Halustepts) generating 2‐D and 3‐D image data sets. The 2‐D image data had a collection time of 16.5 min per image at an image resolution of 2.2 mm per pixel. The 3‐D data had a collection time of 13 h per image with a 2.2 × 2.2 × 2.2 mm voxel resolution. Low‐field magnetic resonance imaging worked well for visualizing roots in moderate to high clay soils, demonstrating the potential for this technology; however, the broad application of this platform is hampered due to the prohibitively long scanning time to obtain 3‐D images. By increasing the field strength, and therefore the signal‐to‐noise ratio, faster scan times can enable a more useful system for root phenotyping.

Bagnall, G. Cody↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An image classification deep-learning algorithm for shrapnel detection from ultrasound images

Ultrasound imaging is essential for non-invasively diagnosing injuries where advanced diagnostics may not be possible. However, image interpretation remains a challenge as proper expertise may not be available. In response, artificial intelligence algorithms are being investigated to automate image analysis and diagnosis. Here, we highlight an image classification convolutional neural network for detecting shrapnel in ultrasound images. As an initial application, different shrapnel types and sizes were embedded first in a tissue mimicking phantom and then in swine thigh tissue. The algorithm architecture was optimized stepwise by minimizing validation loss and maximizing F1 score. The final algorithm design trained on tissue phantom image sets had an F1 score of 0.95 and an area under the ROC curve of 0.95. It maintained higher than a 90% accuracy for each of 8 shrapnel types. When trained only on swine image sets, the optimized algorithm format had even higher metrics: F1 and area under the ROC curve of 0.99. Overall, the algorithm developed resulted in strong classification accuracy for both the tissue phantom and animal tissue. This framework can be applied to other trauma relevant imaging applications such as internal bleeding to further simplify trauma medicine when resources and image interpretation are scarce.

59 BASIC BIOLOGICAL SCIENCES↗

SNIa Cosmology Analysis Results from Simulated LSST Images: From Difference Imaging to Constraints on Dark Energy

Abstract The Vera Rubin Observatory Legacy Survey of Space and Time (LSST) is expected to process ∼10 6 transient detections per night. For precision measurements of cosmological parameters and rates, it is critical to understand the detection efficiency, magnitude limits, artifact contamination levels, and biases in the selection and photometry. Here we rigorously test the LSST Difference Image Analysis (DIA) pipeline using simulated images from the Rubin Observatory LSST Dark Energy Science Collaboration Data Challenge (DC2) simulation for the Wide-Fast-Deep survey area. DC2 is the first large-scale (300 deg 2 ) image simulation of a transient survey that includes realistic cadence, variable observing conditions, and CCD image artifacts. We analyze ∼15 deg 2 of DC2 over a 5 yr time span in which artificial point sources from Type Ia supernova (SNIa) light curves have been overlaid onto the images. The magnitude limits per filter are u = 23.66 mag, g = 24.69 mag, r = 24.06 mag, i = 23.45 mag, z = 22.54 mag, and y = 21.62 mag. The artifact contamination levels are ∼90% of all detections, corresponding to ∼1000 artifacts deg –2 in g band, and falling to 300 deg –2 in y band. The photometry has biases <1% for magnitudes 19.5 < m < 23. Our DIA performance on simulated images is similar to that of the Dark Energy Survey difference-imaging pipeline on real images. We also characterize DC2 image properties to produce catalog-level simulations needed for distance bias corrections. We find good agreement between DC2 data and simulations for distributions of signal-to-noise ratio, redshift, and fitted light-curve properties. Applying a realistic SNIa cosmology analysis for redshifts z < 1, we recover the input cosmology parameters to within statistical uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Image understanding and interpretation in microwave diversity imaging

The authors investigate microwave imaging of metallic objects using a diversity method and interpret and predict the reconstructed image from an approach based on analysis of the scattering mechanism and a back-projection algorithm used in image retrieval. The connection between the various scattering mechanisms and the reconstructed images is discussed, what the images represent is interpreted, and a prediction is made as to what the image will look like over given spectral and angular windows. A brief description is given of the microwave diversity imaging system and the formulation of the microwave diversity imaging based on the physical optics approximation. The scattering mechanism of a complex shaped metallic object is then briefly reviewed and an alternate approach to interpreting the reconstructed image based on the understanding of the scattering mechanism and the reconstruction algorithm is given. Several numerical and experimental examples are included to support this interpretation approach.

Li, Hsueh-Jyh↗

An adaptive technique to maximize lossless image data compression of satellite images

Data compression will pay an increasingly important role in the storage and transmission of image data within NASA science programs as the Earth Observing System comes into operation. It is important that the science data be preserved at the fidelity the instrument and the satellite communication systems were designed to produce. Lossless compression must therefore be applied, at least, to archive the processed instrument data. In this paper, we present an analysis of the performance of lossless compression techniques and develop an adaptive approach which applied image remapping, feature-based image segmentation to determine regions of similar entropy and high-order arithmetic coding to obtain significant improvements over the use of conventional compression techniques alone. Image remapping is used to transform the original image into a lower entropy state. Several techniques were tested on satellite images including differential pulse code modulation, bi-linear interpolation, and block-based linear predictive coding. The results of these experiments are discussed and trade-offs between computation requirements and entropy reductions are used to identify the optimum approach for a variety of satellite images. Further entropy reduction can be achieved by segmenting the image based on local entropy properties then applying a coding technique which maximizes compression for the region. Experimental results are presented showing the effect of different coding techniques for regions of different entropy. A rule-base is developed through which the technique giving the best compression is selected. The paper concludes that maximum compression can be achieved cost effectively and at acceptable performance rates with a combination of techniques which are selected based on image contextual information.

Stewart, Robert J.↗

GOES-R Solar UltraViolet Imager Extended Coronal Imaging

GOES-16 and GOES-17 each hosts a Solar UltraViolet Imager (SUVI) that images the Sun in six extreme ultraviolet (EUV) wavelengths: 9.4 nm, 13.1nm, 17.1nm, 19.5nm, 28.4nm, and 30.4nm. The SUVI is nominally Sun-pointed and has a four-minute imaging sequence covering all the channels and meeting the dynamic range requirements. Based on the SUVI capabilities observed on-orbit, a campaign to image the extended solar corona was undertaken in 2018. This was performed by off-pointing the SUVI line-of-sight to the left and right of the Sun and producing a composite image by stitching together the off-pointed and the Sun-centered images. The imaging area in the composite is about three times the nominal image area in the East-West direction (about 5 RSun versus 1.8 RSun for nominal images). The campaign was conducted in February (4 hours), June (72 hours), and August-September of 2018 (5 weeks). Results from the campaign indicated the presence of solar corona to three solar radii, even in the quiet Sun part of the solar cycle. NOAA can operationalize this concept by tasking the SUVI on one of GOES-E and GOES-W. Such long-term operation will provide data that is needed to establish the much needed connectivity between the EUV and white light coronagraph data for the CME events.

Extended Coronal↗

A General Framework for Monitoring Image Acquisition Workflow in the Radiology Environment: Timeliness for Acute Stroke CT Imaging

Many facets of an image acquisition workflow leave a digital footprint, making workflow analysis amenable to an informatics-based solution. This paper describes a detailed framework for analyzing workflow and uses acute stroke response timeliness in CT as a practical demonstration. We review methods for accessing the digital footprints resulting from common technologist/device interactions. This overview lays a foundation for obtaining data for workflow analysis. We demonstrate the method by analyzing CT imaging efficiency in the setting of acute stroke. We successfully used digital footprints of CT technologists to analyze their workflow. We presented an overview of other digital footprints including but not limited to contrast administration, patient positioning, billing, reformat creation, and scheduling. A framework for analyzing image acquisition workflow was presented. This framework is transferable to any modality, as the key steps of image acquisition, image reconstruction, image post processing, and image transfer to PACS are common to any imaging modality in diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Manifold projection image segmentation for nano-XANES imaging

As spectral imaging techniques are becoming more prominent in science, advanced image segmentation algorithms are required to identify appropriate domains in these images. We present a version of image segmentation called manifold projection image segmentation (MPIS) that is generally applicable to a broad range of systems without the need for training because MPIS uses unsupervised machine learning with a few physically motivated hyperparameters. We apply MPIS to nanoscale x-ray absorption near edge structure (XANES) imaging, where XANES spectra are collected with nanometer spatial resolution. We show the superiority of manifold projection over linear transformations, such as the commonly used principal component analysis (PCA). Moreover, MPIS maintains accuracy while reducing computation time and sensitivity to noise compared to the standard nano-XANES imaging analysis procedure. Finally, we demonstrate how multimodal information, such as x-ray fluorescence data and spatial location of pixels, can be incorporated into the MPIS framework. We propose that MPIS is adaptable for any spectral imaging technique, including scanning transmission x-ray microscopy, where the length scale of domains is larger than the resolution of the experiment.

36 MATERIALS SCIENCE↗

Imaging post-stereotactic body radiation therapy responses for hepatocellular carcinoma: typical imaging patterns and pitfalls

Stereotactic body radiation therapy (SBRT) has increased utility in the management of hepatocellular carcinoma (HCC) ranging from local therapy in early-stage HCC not suitable for other focal therapies to end-stage HCC. As the indications for the use of SBRT in HCC expand, diagnostic imaging is being increasingly used to assess response to treatment. The imaging features of tumor response do not parallel those of other focal therapies such as radiofrequency ablation or trans-arterial chemoembolization that immediately devascularize the tumor. The tumor response to SBRT on imaging takes much longer and often shows gradual changes including the reduction of enhancement and size over several months. It is essential to recognize the typical imaging patterns of response, as well as the appearance of focal liver reaction in the non-target liver that can confound image interpretation. The timing of treatment response assessment imaging is fundamental to minimize the potential for false negative response. The purpose of this article is to review the variable post-SBRT imaging features of HCC and adjacent liver parenchyma and discuss the potential pitfalls of imaging evaluation after SBRT for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considerations for three-dimensional image reconstruction from experimental data in coherent diffractive imaging

The Datasets folder contains 3 datasets, corresponding to the datasets mentioned in the article with 670, 2691 and 586 images. The Runs folder has all the runs used. Besides the images itself it also contains tags for each image under `/entry_1/image_1/detector_and_photon_corrected/tags`. The `headings` attribute gives the name of each tag. The `Jonas Strict` tag corresponds to the 670 images, the `Redflamingo` tag to the 2691 images and the `Redflamingo_Ida_subset` tag to the 586 images. The final dataset with 260 images can be obtained from `Datasets/amoc6914-Redflamingo-manual-586.h5` and use the `/model/diameterNM` group to select the 260 images with size closest to 214 nm.

AMO↗

Plasmonic nanorod probes’ journey inside plant cells for in vivo SERS sensing and multimodal imaging

Nanoparticle-based platforms are gaining strong interest in plant biology and bioenergy research to monitor and control biological processes in whole plants. However, in vivo monitoring of biomolecules using nanoparticles inside plant cells remains challenging due to the impenetrability of the plant cell wall to nanoparticles beyond the exclusion limits (5-20 nm). To overcome this physical barrier, we have designed unique bimetallic silver-coated gold nanorods (AuNR@Ag) capable of entering plant cells, while conserving key plasmonic properties in the near-infrared (NIR). To demonstrate cellular internalization and tracking of the nanorods inside plant tissue, we used a comprehensive multimodal imaging approach that included transmission electron microscopy (TEM), confocal fluorescence microscopy, two-photon luminescence (TPL), X-ray fluorescence microscopy (XRF), and photoacoustics imaging (PAI). We successfully acquired SERS signals of nanorods in vivo inside plant cells of tobacco leaves. On the same leaf samples, we applied orthogonal imaging methods, TPL and PAI techniques for in vivo imaging of the nanorods. This study first demonstrates the intracellular internalization of AuNR@Ag inside whole plant systems for in vivo SERS analysis in tobacco cells. This work demonstrates the potential of this nanoplatform as a new nanotool for intracellular in vivo biosensing for plant biology.

Cupil-Garcia, Vanessa↗

Deep-Learning Electron Diffractive Imaging

Here, we report the development of deep-learning coherent electron diffractive imaging at subangstrom resolution using convolutional neural networks (CNNs) trained with only simulated data. We experimentally demonstrate this method by applying the trained CNNs to recover the phase images from electron diffraction patterns of twisted hexagonal boron nitride, monolayer graphene, and a gold nanoparticle with comparable quality to those reconstructed by a conventional ptychographic algorithm. Fourier ring correlation between the CNN and ptychographic images indicates the achievement of a resolution in the range of 0.70 and 0.55 Å. We further develop CNNs to recover the probe function from the experimental data. The ability to replace iterative algorithms with CNNs and perform real-time atomic imaging from coherent diffraction patterns is expected to find applications in the physical and biological sciences.

47 OTHER INSTRUMENTATION↗

Survey of Image Denoising Methods for Medical Image Classification

Medical imaging devices, such as X-ray machines, inherently produce images that suffer from visual noise. Our objectives were to (i.) determine the effect of image denoising on a medical image classification task, and (ii.) determine if there exists a correlation between image denoising performance and medical image classification performance. We performed the medical image classification task on chest X-rays using the DenseNet-121 convolutional neural network (CNN) and used the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) metrics as the image denoising performance measures. We first found that different denoising methods can make a statistically significant difference in classification performance for select labels. We also found that denoising methods affect fine-tuned models more than randomly-initialized models and that fine-tuned models have significantly higher and more uniform performance than randomly-initialized models. Lastly, we found that there is no significant correlation between PSNR and SSIM values and classification performance for our task.

Michael, Peter↗