Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

MO-DE-207A-02: A Feature-Preserving Image Reconstruction Method for Improved Pancreaticlesion Classification in Diagnostic CT Imaging

Purpose: To develop a feature-preserving model based image reconstruction (MBIR) method that improves performance in pancreatic lesion classification at equal or reduced radiation dose. Methods: A set of pancreatic lesion models was created with both benign and premalignant lesion types. These two classes of lesions are distinguished by their fine internal structures; their delineation is therefore crucial to the task of pancreatic lesion classification. To reduce image noise while preserving the features of the lesions, we developed a MBIR method with curvature-based regularization. The novel regularization encourages formation of smooth surfaces that model both the exterior shape and the internal features of pancreatic lesions. Given that the curvature depends on the unknown image, image reconstruction or denoising becomes a non-convex optimization problem; to address this issue an iterative-reweighting scheme was used to calculate and update the curvature using the image from the previous iteration. Evaluation was carried out with insertion of the lesion models into the pancreas of a patient CT image. Results: Visual inspection was used to compare conventional TV regularization with our curvature-based regularization. Several penalty-strengths were considered for TV regularization, all of which resulted in erasing portions of the septation (thin partition) in a premalignant lesion. At matched noise variance (50% noise reduction in the patient stomach region), the connectivity of the septation was well preserved using the proposed curvature-based method. Conclusion: The curvature-based regularization is able to reduce image noise while simultaneously preserving the lesion features. This method could potentially improve task performance for pancreatic lesion classification at equal or reduced radiation dose. The result is of high significance for longitudinal surveillance studies of patients with pancreatic cysts, which may develop into pancreatic cancer. The Senior Author receives financial support from Siemens GmbH Healthcare.

60 APPLIED LIFE SCIENCES↗

Quality metrics for sensor images

Methods are needed for evaluating the quality of augmented visual displays (AVID). Computational quality metrics will help summarize, interpolate, and extrapolate the results of human performance tests with displays. The FLM Vision group at NASA Ames has been developing computational models of visual processing and using them to develop computational metrics for similar problems. For example, display modeling systems use metrics for comparing proposed displays, halftoning optimizing methods use metrics to evaluate the difference between the halftone and the original, and image compression methods minimize the predicted visibility of compression artifacts. The visual discrimination models take as input two arbitrary images A and B and compute an estimate of the probability that a human observer will report that A is different from B. If A is an image that one desires to display and B is the actual displayed image, such an estimate can be regarded as an image quality metric reflecting how well B approximates A. There are additional complexities associated with the problem of evaluating the quality of radar and IR enhanced displays for AVID tasks. One important problem is the question of whether intruding obstacles are detectable in such displays. Although the discrimination model can handle detection situations by making B the original image A plus the intrusion, this detection model makes the inappropriate assumption that the observer knows where the intrusion will be. Effects of signal uncertainty need to be added to our models. A pilot needs to make decisions rapidly. The models need to predict not just the probability of a correct decision, but the probability of a correct decision by the time the decision needs to be made. That is, the models need to predict latency as well as accuracy. Luce and Green have generated models for auditory detection latencies. Similar models are needed for visual detection. Most image quality models are designed for static imagery. Watson has been developing a general spatial-temporal vision model to optimize video compression techniques. These models need to be adapted and calibrated for AVID applications.

Ahumada, AL↗

Imaging shapes of atomic nuclei in high-energy nuclear collisions

Atomic nuclei are self-organized, many-body quantum systems bound by strong nuclear forces within femtometre-scale space. These complex systems manifest a variety of shapes, traditionally explored using non-invasive spectroscopic techniques at low energies. However, at these energies, their instantaneous shapes are obscured by long-timescale quantum fluctuations, making direct observation challenging. Here we introduce the collective-flow-assisted nuclear shape-imaging method, which images the nuclear global shape by colliding them at ultrarelativistic speeds and analysing the collective response of outgoing debris. This technique captures a collision-specific snapshot of the spatial matter distribution within the nuclei, which, through the hydrodynamic expansion, imprints patterns on the particle momentum distribution observed in detectors. We benchmark this method in collisions of ground-state uranium-238 nuclei, known for their elongated, axial-symmetric shape. Our findings show a large deformation with a slight deviation from axial symmetry in the nuclear ground state, aligning broadly with previous low-energy experiments. This approach offers a new method for imaging nuclear shapes, enhances our understanding of the initial conditions in high-energy collisions and addresses the important issue of nuclear structure evolution across energy scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technique for improving solid state mosaic images

Method identifies and corrects mosaic image faults in solid state visual displays and opto-electronic presentation systems. Composite video signals containing faults due to defective sensing elements are corrected by a memory unit that contains the stored fault pattern and supplies the appropriate fault word to the blanking circuit.

Saboe, J. M.↗

Digital image registration method using boundary maps

A new method of automatic image registration (matching) is presented. It requires that the original single or multichannel images first be converted to binary boundary maps having elements equal to zero or unity. The method corrects for both translational and rotational errors. One feature of the technique is the rapid calculation of a pseudo correlation matrix NCOR using only integer additions. It is argued that the use of boundary maps is advisable when the data from the two images are acquired under different conditions; i.e., weather conditions, lighting conditions, etc.

Andrus, J. F.↗

Boron-based dual imaging probes, compositions and methods for rapid aqueous F-18 labeling, and imaging methods using same

A composition useful as a PET and/or fluorescence imaging probe a compound a compound of Formula I, including salts, hydrates and solvates thereof: ##STR00001## wherein R.sub.1-R.sub.7 may be independently selected from hydrogen, halogen, hydroxy, alkoxy, nitro, substituted and unsubstituted amino, cycloalkyl, carboxy, carboxylic acids and esters thereof, cyano, haloalkyl, aryl, X is selected from the group consisting of C and N; and A is selected of hydrogen, halogen, hydroxy, alkoxy, nitro, substituted and unsubstituted amino, alkyl, cycloalkyl, carboxy, carboxylic acids and esters thereof, cyano, haloalkyl, aryl, including phenyl and aminophenyl, and heteroaryl.

47 OTHER INSTRUMENTATION↗

Gamma ray Imaging Based Methods to Improve the Accuracy of Uranium Holdup Quantification

Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Recent Developments in Tolerancing Methods for Imaging Spectrometers

We discuss detailed tolerancing methods developed for imaging spectrometers at NASA Jet Propulsion Laboratory, California Institute of Technology using the Earth Surface Mineral Dust Source Investigation (EMIT) imaging spectrometer as an illustrative example. We tolerance five metrics simultaneously: along-track response function, cross-track response function, spectral response function, spectral centroid uniformity, and spatial centroid uniformity. A method to calculate tolerancing sensitivities for each metric directly, a method to statistically combine Monte Carlo files from multiple tolerancing runs, and an example summary error budgets that communicate the key and driving tolerances for each metric are discussed. These methods facilitate rapid and semi-automated assessment of the predicted performance of imaging spectrometer systems from design through to assembly and launch life cycle, using metrics that are directly relevant to the extraction of accurate spectroscopic data from these instruments.

Mouroulis, Pantazis↗

System and method for image registration of multiple video streams

Provided herein are methods and systems for image registration from multiple sources. A method for image registration includes rendering a common field of interest that reflects a presence of a plurality of elements, wherein at least one of the elements is a remote element located remotely from another of the elements and updating the common field of interest such that the presence of the at least one of the elements is registered relative to another of the elements.

47 OTHER INSTRUMENTATION↗

Moving-Article X-Ray Imaging System and Method for 3-D Image Generation

An x-ray imaging system and method for a moving article are provided for an article moved along a linear direction of travel while the article is exposed to non-overlapping x-ray beams. A plurality of parallel linear sensor arrays are disposed in the x-ray beams after they pass through the article. More specifically, a first half of the plurality are disposed in a first of the x-ray beams while a second half of the plurality are disposed in a second of the x-ray beams. Each of the parallel linear sensor arrays is oriented perpendicular to the linear direction of travel. Each of the parallel linear sensor arrays in the first half is matched to a corresponding one of the parallel linear sensor arrays in the second half in terms of an angular position in the first of the x-ray beams and the second of the x-ray beams, respectively.

Fernandez, Kenneth R.↗

Applying image processing methods to study hydrodynamic characteristics in a rectangular spouted bed

This paper presents systematic image processing methods for investigating hydrodynamic characteristics in a rectangular spouted bed (30.2 mm × 101.6 mm). The objective is to provide a non-intrusive technique to determine the bed expansion ratio, the jet height and the fountain height due to their significant influence on the hydrodynamics of the entire bed. A high-speed video camera is used in the experiment with Geldart D particles as the bed material. After the image acquisition, image denoising, thresholding, logical and mask operations are applied correspondingly for the boundary discrimination, based on which an algorithm has been developed to determine the bed height successfully. With the discriminated boundary, morphological operations viz. erosion and dilation have been used to accurately determine the jet height and the fountain height. The feasibility of the technique is proven through profiles of bed expansion ratio, jet height and fountain height under three initial bed heights (0.0762 m, 0.102 m, and 0.127 m) for two different nozzle sizes (0.0096 m and 0.0127 m). Depending on the determination of the hydrodynamic characteristics, different flow regimes can be distinguished comprehensively through profiles of the bed expansion ratio and bed pressure drop in combination with the standard deviation of jet/fountain height. The proposed flow regime discrimination verifies the feasibility and effectiveness of the image processing methods in assessing the solids behavior in the spouted beds. Results about the variation of the jet height and the fountain height under current operating conditions as determined by the new technique are also discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Method of imaging the electrical conductivity distribution of a subsurface

A method of imaging electrical conductivity distribution of a subsurface containing metallic structures with known locations and dimensions is disclosed. Current is injected into the subsurface to measure electrical potentials using multiple sets of electrodes, thus generating electrical resistivity tomography measurements. A numeric code is applied to simulate the measured potentials in the presence of the metallic structures. An inversion code is applied that utilizes the electrical resistivity tomography measurements and the simulated measured potentials to image the subsurface electrical conductivity distribution and remove effects of the subsurface metallic structures with known locations and dimensions.

36 MATERIALS SCIENCE↗

SU-G-IeP3-09: Investigating the Interplay of Antiscatter Grids with Modern Detectors and Image Processing in Digital Radiography

Purpose: To use phantom and simulation experiments to relate technique factors, patient size and antiscatter grid use to image quality in portable digital radiography (DR), in light of advancements in detector design and image processing. Methods: Image contrast-to-noise ratio (CNR) on a portable DR system (MobileDaRt Evolution, Shimadzu) was measured by imaging four aluminum inserts of varying thickness, superimposed on a Lucite slab phantom using a pediatric abdominal protocol. Three thicknesses of Lucite were used: 6.1cm, 12cm, and 18.2cm, with both 55 and 65 kVp beams. The mAs was set so that detector entrance exposure (DEE) was matched between kVp values. Each technique and phantom was used with and without an antiscatter grid (focused linear grid embedded in aluminum with an 8:1 ratio). The CNR-improvement-factor was then used to determine the thickness- and technique-dependent appropriateness of grid use. Finally, the same experiment was performed via Monte Carlo simulation, integrating incident energy fluence at each detector pixel, so that effects of detector design and image processing could be isolated from physical factors upstream of the detector. Results: The physical phantom experiment demonstrated a clear improvement for the lower tube voltage (55kVp), along with substantial CNR benefits with grid use for 12–18cm phantoms. Neither trend was evident with Monte Carlo, suggesting that suboptimal quantum-detection-efficiency and automated grid-removal could explain trends in kVp and grid use, respectively. Conclusion: Physical experiments demonstrate marked improvement in CNR when using a grid for phantoms of 12 and 18cm Lucite thickness (above ∼10cm soft-tissue equivalent). This benefit is likely due to image processing, as this result was not seen with Monte Carlo. The impact of image processing on image resolution should also be investigated, and the CNR benefit of low kVp and grid use should be weighed against the increased exposure time necessary to achieve adequate DEE.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-06: Impact of Temporal Image Coregistration Methods On 3D Internal Dose Calculations in Targeted Radionuclide Therapy

Purpose: The calculation of 3D internal dose calculations in targeted radionuclide therapy requires the acquisition and temporal coregistration of a serial PET/CT or SPECT/CT images. This work investigates the dosimetric impact of different temporal coregistration methods commonly used for 3D internal dosimetry. Methods: PET/CT images of four mice were acquired at 1, 24, 48, 72, 96, 144 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose rate (ADR) was calculated at each time point using a Geant4-based MC dosimetry platform using three temporal image coregistration Methods: (1) no coregistration (NC), whole body sequential CT-CT affine coregistration (WBAC), and individual sequential ROI-ROI affine coregistration (IRAC). For NC, only the ROI mean ADR was integrated to obtain ROI mean doses. For WBAC, the CT at each time point was coregistered to a single reference CT. The CT transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the whole CT volume. For IRAC, each individual ROI was isolated and sequentially coregistered to a single reference ROI. The ROI transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the ROI volumes. Results: The percent differences in the ROI mean doses were as large as 109%, 88%, and 32%, comparing the WBAC vs. IRAC, NC vs. IRAC, and NC vs. WBAC methods, respectively. The CoV in the mean dose between the all three methods ranged from 2–36%. The pronounced curvature of the spinal cord was not adequately coregistered using WBAC which resulted in large difference between the WBAC and IRAC. Conclusion: The method used for temporal image coregistration can result in large differences in 3D internal dosimetry calculations. Care must be taken to choose the most appropriate method depending on the imaging conditions, clinical site, and specific application. This work is partially funded by NIH Grant R21 CA198392-01.

60 APPLIED LIFE SCIENCES↗

Application of abstract harmonic analysis to the high-speed recognition of images

Methods are constructed for rapidly computing correlation functions using the theory of abstract harmonic analysis. The theory developed includes as a particular case the familiar Fourier transform method for a correlation function which makes it possible to find images which are independent of their translation in the plane. Two examples of the application of the general theory described are the search for images, independent of their rotation and scale, and the search for images which are independent of their translations and rotations in the plane.

Usikov, D. A.↗

The Michigan New Technology Training and Research (MNTR) Translational Program in Nuclear Medicine (Final Report)

The Michigan New Technology Training and Research (MNTR) Translational Program in Nuclear Medicine and Molecular Imaging This project established the Michigan New Technology Training and Research (MNTR) translational program, focused on the acceleration of new clinical molecular imaging methods. Molecular imaging approaches to imaging are a very flexible and powerful development, with many recent examples advancing the diagnosis and guiding the management of human disease. These methods depend on the design, synthesis and testing of new radiotracers (molecules designed to target specific cells or tissues in the body), labeled with short-lived radioactive atoms (positron emitters). The new radiotracers are imaged in the human body using positron emission tomography (PET) imaging. The University of Michigan PET Center has considerable experience in the discovery, development, refinement and initial human applications of new PET radiotracers. An emerging impediment to efficient availability of new PET radiotracers, however, involves the regulatory environment at multiple levels. Many potentially successful ideas are delayed or even prevented from entering human use by these barriers. In the current grant, we provided hands-on experience for the next generation of young scientists working in molecular imaging so that they are equipped to effectively move new ideas and radiotracers from the research laboratory to the nuclear medicine clinic (bench-to-bedside). For new radiotracer development, oversight by the Food and Drug Administration (FDA), the Nuclear Regulatory Commission (NRC), and local institutional committees and reviews are required. These aspects of translation from laboratory to clinic are often omitted from the formal training of new scientists, but were provided to three trainees via direct mentorship in the MNTR program. The MNTR training program built on the translational successes of the University of Michigan Division of Nuclear Medicine and capitalized on our strengths (facilities, faculty, a wide-ranging selection of projects, and the experience and commitment to bring new radiotracers into human studies) to systematically train three fellows in radiochemistry and nuclear medicine. Integrated training in development, validation and clinical translation of new PET radiotracers occurred through practical involvement in multiple research projects, each at a different stage along the pathway from bench-to-bedside. Each trainee obtained experience of the entire process over about 2 years. Projects involved development of new radiotracers for neurodegenerative disorders (e.g. Alzheimer disease), movement disorders (e.g. Parkinson disease, progressive supranuclear palsy) and neurodevelopmental syndromes (e.g. Tourette syndrome) as well as new radiochemistry methods for synthesizing radiotracers. Each project was pursued in a close collaboration between the fellow trainee and both the clinical and basic science faculty at the University of Michigan PET Center, and provided an unprecedented opportunity for the highest-level training in academic radiochemistry and nuclear medicine research. The project has resulted in 17 peer-reviewed publications to date, and at least 4 more are in preparation. Additionally, 1 book chapter and 26 conference presentations have resulted from this grant. Upon completion of the MNTR Program, the trainees have emerged as translational scientists wielding the necessary skill-set (practical research experience, multidisciplinary training, regulatory know-how) to embark on successful careers in translational molecular imaging, bringing continued advances in the field to bear on important human disorders. As a metric of the Program’s success, one fellow has already secured employment in the field, while the other two are finishing writing papers; they wish to also stay in the radiochemistry and nuclear medicine community, and are currently applying for jobs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗