Search NASA⌕ Search

SEARCH · Search NASA

Results for “impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Distributed Photovoltaic Economic Impact Analysis in Indonesia

Like other countries in the region, the Government of Indonesia aims to increase its use renewable energy in the near term from various technologies, including grid-connected distributed photovoltaics (DPV). While little DPV has been installed to date, the policy landscape has been shifting over the past few years with recent pronouncements from the state-run utility Perusahaan Listrik Negara (PLN) and the Ministry of Energy and Mines (MEMR) that have begun to provide a more supportive policy framework for the deployment of DPV. Nonetheless, many questions remain as to how DPV impacts customers, the utility, and the economy as a whole. This report presents a holistic view of DPV economic impacts in the Java-Bali region of Indonesia by assessing customer economic impacts, utility revenue impacts, and jobs and economic development impacts.

14 SOLAR ENERGY↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

Impact analysis of DERs on bulk power system stability through the parameterization of aggregated DER_a model for real feeders

With an ever increasing percentage of distributed energy resources (DERs) connected behind the meter in the distribution system, it is becoming increasingly important to equip transmission planners with the visibility of DER dynamic performance in distribution system. Not having visibility of the disconnection of DERs with the occurrence of transmission events, could result in an erroneous view of the stability of bulk power system. Here, in this paper, a parameterized aggregated model (DER_a) serves as a representation of the distribution-level dynamics of real residential feeders, which is used for analysis of bulk power system stability. The parameters are obtained by executing dynamic Monte Carlo simulations. Faults are then induced at the substation level causing the DERs to trip which subsequently enables the parameterization of the low and high voltage breakpoints (v l0 , v l1 , v h0 , and v h1 ) of the DER_a model’s partial voltage trip block. These parameters are then utilized to study the effectiveness of the DER_a model to represent the behavior of the aggregated DERs’ response and their impact on the bulk power system. The case study shows the ability of the positive-sequence DER_a model to provide an accurate estimation of DERs that are susceptible to trip due to 3-$\phi$ and 1-$\phi$ faults of transmission.

14 SOLAR ENERGY↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Comprehensive process and environmental impact analysis of integrated DBD plasma steam methane reforming

Utilization of electricity generated from renewable sources to obtain hydrogen, H 2 , is of critical importance to decrease the overall carbon footprint. Here in this work, integration of a dielectric discharge barrier (DBD) plasma reactor to convert low calorific value gas, such as landfill gas or coal mine gas into hydrogen, into the existing steam methane reforming (SMR) technology was evaluated using process design considerations. In particular, a DBD-enhanced catalytic SMR reactor was modeled to operate at near atmospheric pressure and 500 °C sequentially with the conventional reformer to obtain ~ 65 kmol/hr H2 for distributed production. This allowed decreasing the size of the conventional reformer albeit at the increased overall electricity consumption. Calculated process economics showed that only at an electricity cost of less than $0.004/kWh does the hybrid DBD plasma process derived H 2 price become competitive with that of the conventional SMR. A Life Cycle Assessment framework was used to compare environmental impacts from the conventional SMR, hybrid DBD SMR and hybrid DBD SMR utilizing only onshore wind-derived electricity. Larger environmental impacts in the plasma reformer were obtained due to the use of electricity for the plasma reforming operation, which was modeled as coming from the typical U.S. grid mix. Utilizing only 100% wind-derived electricity provided certain environmental benefits, except for the ecotoxicity impact where the wind power scenario modeled here only reduced ecotoxicity impacts associated with electricity by 30%.

08 HYDROGEN↗

Adaptive Multi-Layer LMS Controller Design and Application to Active Vibration Suppression on a Truss and Proposed Impact Analysis Technique

This research develops an adaptive controller that actively suppresses a single frequency disturbance source at a remote position and tests the system on the NPS Space Truss. The experimental results are then compared to those predicted by an ANSYS finite element model. The NPS space truss is a 3.7-meter long truss that simulates a space-borne appendage with sensitive equipment mounted at its extremities. One of two installed piezoelectric actuators and an Adaptive Multi-Layer LMS control law were used to effectively eliminate an axial component of the vibrations induced by a linear proof mass actuator mounted at one end of the truss. Experimental and analytical results both demonstrate reductions to the level of system noise. Vibration reductions in excess of 50dB were obtained through experimentation and over 100dB using ANSYS, demonstrating the ability to model this system with a finite element model. This report also proposes a method to use distributed quartz accelerometers to evaluate the location, direction, and energy of impacts on the NPS space truss using the dSPACE data acquisition and processing system to capture the structural response and compare it to known reference Signals.

Barney, Timothy A.↗

Vibro-impact analysis and characterization of pipeline conveying fluids with multi-segmented motion-limiting constraints

Previous studies of the cantilevered pipeline conveying fluid system have included motion-limiting constraints in the form of trilinear springs. While this is desirable in experimental scenarios, it may not be representative of real-world applications. Therefore, here, this study focuses on multi-segmented motion-limiting constraints. As this type of motion-limiting constraint has not been investigated with a cantilevered pipeline system, a wide variety of outer and inner constraint stiffness and constraint gap sizes are investigated in this study to gain a comprehensive understanding of how the multi-segmented constraints affect the dynamics of the cantilevered pipeline. In this effort, bifurcation diagrams, phase portraits, Poincare maps, time histories, and power spectra are used to investigate the dynamics of the system, and the fluid flow speeds where dynamic characteristics are considered. In general, it is found that critical flow speeds like when the pipe sticks in the constraints are reduced as the constraint stiffnesses are increased. Additionally, the sticking flow speed occurred at lower flow speeds as the gap sizes of the inner and outer constraints decrease, and a larger constraint offset results in a smaller inner gap size leading to critical behaviors occurring at earlier flow speeds.

97 MATHEMATICS AND COMPUTING↗

Exploring thermal runaway propagation in Li-ion batteries through high-speed X-ray imaging and thermal analysis: Impact of cell chemistry and electrical connections

Battery safety design is important to consider from the individual Li-ion cell to the level of the macro-system. On the macro-level, failure in one single cell can lead to propagation of the thermal runaway and rapidly set a whole battery pack on fire. Factors that can impact the propagation outcome, such as cell model/chemistry and electrical connection are here investigated using a combination of measurements. Several abusive tests were conducted, combining two different cell models (Molicel P42A and LG M50, both 21700s) in series and parallel connections (16 tests per configuration). Overall, a propagation outcome of 56% was measured from the 32 conducted tests, a minimum temperature of 150 °C was required to initiate propagation, and the fastest propagation occurred in 123 s. Temperature measurements were higher in series connected cells, initiating the discussion of cell chemistry and internal resistance on this effect. The difference in current-flow during thermal runaway in series and parallel connections, and how this can affect the temperature evolution is further discussed. Spatio-temporal mapping of X-ray radiography allowed us to derive the speed of thermal runaway evolution inside the battery and has shown that series connected cells, in particular P42A, occur faster. It was further observed that deviant sidewall behaviors such as temperature-induced breaches and pressure-induced ruptures occurred in P42As only respective nail-penetrated cells only.

25 ENERGY STORAGE↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

Summary Report for the NEPA Impact Analysis. Revision 1

The Waste Isolation Pilot Plant (WIPP), located in southeastern New Mexico, has been developed by the U.S. Department of Energy (DOE) for the geologic (deep underground) disposal of defense-related transuranic (TRU) waste. Containment of TRU waste at the WIPP facility is derived from standards set forth in Title 40 of the Code of Federal Regulations (CFR), Part 191. The DOE assesses compliance with the containment standards according to the Certification Criteria in Title 40 CFR Part 194 by means of Performance Assessment (PA) calculations performed by Sandia National Laboratories (SNL). WIPP PA calculations estimate the probability of radionuclide releases from the repository to the accessible environment for a regulatory period of 10,000 years after facility closure. The DOE Carlsbad Field Office (CBFO) has initiated a National Environmental Policy Act (NEPA) action for a proposal to excavate and use additional transuranic (TRU) waste disposal panels at the WIPP facility. This report documents an analysis undertaken as part of an effort to evaluate the potential environmental consequences of the proposed action. Although not explicitly required for a NEPA analysis, evaluations of a dose indicator to hypothetical members of the public after final facility closure are presented in this report. The analysis is carried out in two stages: first, Performance Assessment (PA) calculations quantify the potential releases to the accessible environment over a 10,000-year post-closure period. Second, dose was evaluated for three hypothetical exposure pathways using the conservative radionuclide concentrations assumed to be released to the accessible environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancing the Energy Efficiency of Room Air Conditioners in Malaysia: Opportunities and Impact Analysis

The global room air conditioner (AC) market is rapidly transitioning toward variable-speed units, offering significant opportunities for energy-efficient designs and the adoption of low-global warming potential (GWP) refrigerants. Emerging economies, particularly in regions such as Malaysia, are expected to drive consumer demand for ACs. This report reviews key trends in the Malaysian AC market, including the availability of high-efficient ACs. Currently, variable-speed units account for 30–65% of the market, achieving cooling seasonal performance factor (CSPF) levels of between 5.0 and 6.0. Cost comparisons show that CSPF 5–6-rated, inverter-driven room ACs are competitively priced against lower-efficiency, fixed-speed units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗