Search NASA⌕ Search

SEARCH · Search NASA

Results for “in-situ observations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Process intensification approach to enhancing heat and mass transfer during drying: Ultrasonic (US) assisted drying of paper and board

Drying of paper and board is conventionally achieved through alternating conduction (steam-heated cylinders) and pocket convection (heated air over the paper web surface). These conventional drying systems rely heavily on steam from fossil fuels, resulting in inefficiencies, high energy usage, and thermal losses due to surface-driven mechanisms. Here, to address these challenges, an experimental system, with in-situ drying characteristics measurements, was developed to investigate process intensification using ultrasonic-based dewatering—a volumetric, pressure-driven acoustic energy system—integrated with conventional drying. The objectives of this study are to assess the impact of ultrasonics (US) on dewatering; compare performances to conventional drying systems; identify improvements in drying rate and energy use as a function of moisture content; and gain potential insights on heat and mass transfer mechanisms during US-assisted drying. US performance was evaluated across frequencies, power levels, pulp types, and basis weights. Results show that improvements to ultrasonic applications in conjunction with convection were 30-43% in drying rate and 20-35% in drying time over continuous and intermittent applications. When combined with conduction and convection, ultrasonics yielded up to 20% improvement in both rate and time and up to 20% reduction in energy consumption. Observations support a hypothesis of extension of the constant rate period due to improved capillary flow at higher moisture content and enhancing vapor diffusion and boundary layer disruption at lower moisture contents during falling rate period. These findings will inform future modeling, simulation, design and optimization of advanced drying systems.

42 ENGINEERING↗

Single-particle chemical analysis reveals organic-rich detonation soot products

The detonation of high explosives produces a wide variety of particulate matter (PM) with distinct properties, not all of which are traditionally studied for chemical composition, formation processes, and forensic applications. We report particle-resolved measurements of Composition B detonation soot using soot particle aerosol mass spectrometry (SP-AMS), identifying carbonaceous species and metals not previously characterized on a single-particle basis. Results are combined with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to enhance source-dependent signatures. Black carbon, including graphitic carbon and detonation nanodiamonds, contributed 50.5-71.4% of PM 2.5 mass, while 22.5-43.4% was non-refractory organic carbon, a previously overlooked component that exhibited a complex and varying composition. Detonations were performed with and without PMMA confinement and under steady and overdriven conditions. Distinct particles enriched with polycyclic aromatic hydrocarbons (PAHs) were observed in experiments utilizing confinement, with quantities dependent on manufacturing method. SEM-EDS validated SP-AMS findings of metals internally mixed with carbonaceous species and extended the particle size range to 100 µm. This work makes detecting non-refractory organics using single-particle techniques more feasible for detonation forensics and understanding high-energy soot formation. While this analysis uses offline sample collection, SP-AMS could be deployed for in-situ measurements of detonation PM 2.5 transported in the atmosphere.

36 MATERIALS SCIENCE↗

A novel approach to increase accuracy in remotely sensed evapotranspiration through basin water balance and flux tower constraints

Remote sensing-derived evapotranspiration (RSET) products capture the spatiotemporal variations of evapotranspiration (ET) from field to basin scales with unprecedented details. However, their accuracy varies across RSET estimation methods and diverse hydroclimate regions. While ET modeling efforts to account for biophysical processes and controlling parameters have made good progress in recent years, a parallel approach of integrating in-situ ET with RSET could reduce biases in RSET products. Basin water balance ET (WBET) and flux tower ET are widely applied to evaluate RSET accuracy, yet such ET measurements are rarely used for RSET bias corrections, especially for large area applications. To address this issue, we propose a novel approach: the water balance equivalence (WABE) method, which generates spatially continuous WBET for correcting biases in RSET products. The WABE method computes synthetic WBET by integrating observed WBET and flux tower-derived FLUXCOM ET, which fills the spatial gaps of observed WBET and generates a spatially continuous WBET dataset. Synthetic WBET (2002–2015 annual average) of eight-digit hydrologic unit code (HUC8) basins across the conterminous United States (CONUS), constituting 44 % (887 out of 2035 basins) of CONUS basins, was determined within 2.0 % (RMSE = 12 %) of observed WBET at CONUS and between 1–12 % (RMSE = 3–33 %) across 18 regions in CONUS. With WABE-based bias corrections, the overall annual bias of RSET decreased from 10 % (RMSE = 34 %) to 6 % (RMSE = 26 %) across 37 flux tower sites. The WABE method offers a new approach for RSET accuracy improvement and shows great promise for large area implementations with a potential to yield substantial benefits for building accurate basin water budgets and water management decisions.

Khand, Kul↗

In-situ irradiation of uranium carbide

Uranium carbide (UC) is a leading candidate fuel for Generation IV reactors due to its high uranium density and thermal conductivity. However, its irradiation performance—particularly gas bubble swelling and defect dynamics—remains poorly characterized. Using in-situ transmission electron microscopy (TEM), we irradiated UC with 300 keV Xe + and 1 MeV Kr 2+ ions at temperatures up to 900 °C to quantify swelling behavior and dislocation loop evolution. The swelling remained below 0.6 % across all temperatures, suggesting the dimensional stability of UC under irradiation at these temperatures. Dislocation loops grew faster in UC than in UO 2 or UN, correlating with its lower homologous temperature. Notably, nanograin structures emerged in thin regions of the lamellar, mirroring phenomena previously observed in UO 2 and ZrC. These results address critical knowledge gaps in the radiation tolerance of UC and provide insight into its suitability for advanced reactor systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recrystallization driven softening and heating rate dependencies of FeCrAl nuclear fuel cladding during accident transients

A refined understanding of FeCrAl cladding behavior during rapid transients is critical for its potential deployment in light-water reactors. Current assessments focus on transient burst testing metrics such as balloon geometry, burst temperature, and hoop stress, often used as proxies for simpler conventional tensile properties. However, directly correlating isothermal tensile and creep data with accident transient scenarios remains a challenge, although it is essential for high fidelity model development. Recent modeling based on tensile tests up to 800 °C, conducted with both immediate loading and a 10-minute soak, showed that immediate loading better predicts experimental burst temperatures, indicating a thermal softening effect. Building upon this observation, the current study connects transient performance, microstructural evolution, and high-temperature tensile properties by leveraging results from C26M claddings burst tests performed at heating rates of 1–50 °C/s and hoop stresses from 25 to 100 MPa. At 25 MPa, rupture temperatures varied by only 6 °C, but at 100 MPa, the difference reached 116 °C, with faster heating yielding higher burst temperatures. Microstructural analysis identified recrystallization as the primary cause of heating rate-dependent softening, eliminating prior cold-working. In-situ thermomechanical data linked ballooning onset to localized instabilities, similar to ultimate tensile strength behavior in conventional tensile tests. High heating rates correlated with immediate loading tensile data, while lower rates matched soaked data. Furthermore, by linking burst performance to microstructural evolution and tensile properties, this work provides a foundation for more accurate modeling of FeCrAl claddings and potentially other Fe-based materials under accident conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and Development of Novel Equiatomic Refractory Multi Principal elemental Alloys Based on MoNbTi System for Use in Irradiation Environments

Multi Principal Elemental Alloys (MPEA) have emerged as promising materials for next-generation nuclear reactors due to their exceptional irradiation resistance. Eight equiatomic MPEA based on the MoNbTi system, comprising of elements with low thermal neutron absorption cross-sections were explored using a combined approach employing empirical parameter estimations, and CALPHAD simulations by which the phases and elemental segregation observed in all the alloys in the as-cast state were predicted. Solution heat treatment at 1500°C transformed five alloys into single-phase matrix materials, enhancing homogeneity and reducing hardness. The densities of the alloys ranged between 6.47 to 7.68 g/cm3, hardness between 472 and 656 VHN, Young’s modulus between 142 GPa to 169 GPa, shear modulus between 54 GPa and 62 GPa, bulk modulus between 117 GPa to 194 GPa and Poisson’s ratio between 0.3 to 0.35. The in-situ high temperature Xray diffraction results, differential scanning calorimetry and dilatometry results up to 1000°C suggested the high temperature phase stability of the MPEA. Subsequent ageing heat treatment at 800 and 1000 oC for 96 hours revealed significant secondary phase precipitation in MoNbTiZr, MoNbTiZrV, and MoNbTiCrA. Oxidation studies at 800 oC for 24 hours in air revealed superior oxidation resistance and cubic rate law dependence in Cr containing MPEA especially in MoNbTiCrAl, while severe mass gain resulting in total disintegration and exfoliation in MoNbTiZr and MoNbTiZrV. This comprehensive study underscores the potential of novel MPEA as promising materials for advanced nuclear reactor applications, shedding light on their microstructural control, mechanical properties, thermal stability, and oxidation resistance.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical simulation of coupled THM behaviour of full-scale EBS in backfilled experimental gallery in the Horonobe URL

Bentonite-based engineered barrier system (EBS) is a key component of many repository designs for the geological disposal of high-level radioactive waste. Given the complexity and interaction of the phenomena affecting the barrier system, coupled thermo-hydro-mechanical (THM) numerical analyses are a potentially useful tool for a better understanding of their behaviour. In this context, a Task (the Horonobe EBS experiment) was undertaken to study, using numerical analyses, the thermo-hydro-mechanical (and thermo-hydro) interactions in bentonite based engineered barriers within the international cooperative project DECOVALEX 2023. One full-scale in-situ experiment and four laboratory experiments, largely complementary, were selected for modelling. The Horonobe EBS experiment is a temperature-controlled non-isothermal experiment combined with artificial groundwater injection. The Horonobe EBS experiment consists of the heating and cooling phases. Six research teams performed the THM or TH (depended on research team approach) numerical analyses using a variety of computer codes, formulations and constitutive laws. Finally, for each experiment, the basic features of the analyses are described and the comparison between calculations and laboratory experiments and field observations are presented and discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Whole metagenome sequencing and 16S rRNA gene amplicon analyses reveal the complex microbiome responsible for the success of enhanced in-situ reductive dechlorination (ERD) of a tetrachloroethene-contaminated Superfund site

The North Railroad Avenue Plume (NRAP) Superfund site in New Mexico, USA exemplifies successful chlorinated solvent bioremediation. NRAP was the result of leakage from a dry-cleaning that operated for 37 years. The presence of tetrachloroethene biodegradation byproducts, organohalide respiring genera (OHRG), and reductive dehalogenase (rdh) genes detected in groundwater samples indicated that enhanced reductive dechlorination (ERD) was the remedy of choice. This was achieved through biostimulation by mixing emulsified vegetable oil into the contaminated aquifer. This report combines metagenomic techniques with site monitoring metadata to reveal new details of ERD. DNA extracts from groundwater samples collected prior to and at four, 23 and 39 months after remedy implementation were subjected to whole metagenome sequencing (WMS) and 16S rRNA gene amplicon (16S) analyses. The response of the indigenous NRAP microbiome to ERD protocols is consistent with results obtained from microcosms, dechlorinating consortia, and observations at other contaminated sites. WMS detects three times as many phyla and six times as many genera as 16S. Both techniques reveal abundance changes in Dehalococcoides and Dehalobacter that reflect organohalide form and availability. Methane was not detected before biostimulation but appeared afterwards, corresponding to an increase in methanogenic Archaea. Assembly of WMS reads produced scaffolds containing rdh genes from Dehalococcoides, Dehalobacter, Dehalogenimonas, Desulfocarbo, and Desulfobacula. Anaerobic and aerobic cometabolic organohalide degrading microbes that increase in abundance include methanogenic Archaea, methanotrophs, Dechloromonas, and Xanthobacter, some of which contain hydrolytic dehalogenase genes. Aerobic cometabolism may be supported by oxygen gradients existing in aquifer microenvironments or by microbes that produce O 2 via microbial dismutation. The NRAP model for successful ERD is consistent with the established pathway and identifies new taxa and processes that support this syntrophic process. This project explores the potential of metagenomic tools (MGT) as the next advancement in bioremediation.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

In-situ monitoring of atomically dispersed Pt sites supported on OMS-2 during CO 2 activation

Atomically dispersed catalysts have drawn great interest lately, as they showcase a high density of active sites, selectivity, and high turnover frequencies in oxidation chemistry due to labile oxygen activation. In contrast, the applications of these catalysts have lagged in reduction reactions due to the ambiguity caused by the sintering and restructuring of active sites. To bridge this gap, the evolution of Pt 4+ isomorphically substituted into an octahedral molecular sieve structure (OMS-2) under reductive conditions was correlatively characterized using multiple in-situ analytical techniques such as ambient pressure X-ray photoelectron spectroscopy, environmental transmission electron microscopy, and solid-state nuclear magnetic resonance. The surface dynamics of the Pt single atoms were revealed during the Reverse Water Gas Shift (RWGS) reaction, where the active sites were identified as two-coordinated platinum single atoms. Under reaction, we show nonbinding atoms adjacent to the single atoms restructured the motif of the single atoms to Pt 2+ via ion mobility of potassium, increasing the activation energy by 25.6 kJ/mol. Here, this work also highlights the potential for increased stability of the single atom sites via isomorphic substitution of the metal oxide support, since the Pt-OMS-2 catalyst retained activity for about 33 h before deactivation, after which nanoparticles were observed in TEM images. This work offers a new perspective in single atom synthesis using the metal oxide as the host for the single atom site, instead of adatoms on the surface

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Soil Moisture and Thaw Depth Measurements Coincident with Airborne SAR Data Collections, Seward Peninsula, Alaska, 2022

The in-situ soil moisture and thaw depth measurements provided in this dataset were collected coincident with airborne overflights of L-band synthetic aperture radar (SAR) instruments at the Teller, Kougarok, and Council study sites on the Seward Peninsula, Alaska. Overflights occurred on August 19, 2022. Soil moisture data at Teller and Kougarok was collected on August 19, and at Council on August 20. Thaw depth, soil pits, and any additional measurements were recorded on August 20 and 21. Field measurements and flights were conducted during the summer of 2022 as a collaboration between the National Aeronautics and Space Administration (NASA) Arctic-Boreal Vulnerability Experiment (ABoVE) Project’s Airborne SAR Campaign and the Next-Generation Ecosystem Experiments (NGEE) Arctic Project. This dataset includes a data file (*.csv), a data dictionary (*_dd.csv) and a file-level metadata (*_flmd.csv). The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

EARTH SCIENCE > LAND SURFACE > FROZEN GROUND↗

Water quality data collected from the Muskegon River (MI, USA) using AquaBOT June-July 2024.

This dataset contains processed output from AquaBOT, which combines 30-second interval measurements of GPS location and YSI water quality parameters (temperature (degrees Celsius), dissolved oxygen (mg/l), specific conductance(microSiemens/cm at 25 degrees Celsius), and turbidity (NTU)), for 3 sections of the Muskegon River in Michigan, USA. The file aquabot2024_MuskegonRiver.csv has information on locations, dates and times, and observations. The data were processed by removing observations recorded before and after AquaBOT was in the water and observations where no data values were recorded. No other QA/QC was done. This research was performed as part of the DOE Research Development and Partnership Pilot award “Expanding Collaborative Capacity to Address Climate Resiliency in the Great Lakes Region”, which aims to expand collaborations between researchers at Central Michigan University and U.S. Department of Energy labs and projects focused on enhancing climate resilience in Great Lakes communities and ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Expedition UT-GOM2-2 Site H

Pressure and conventional cores were collected at Site H of the Walker Ridge Protracted Area Block 313 in the Terrebonne Basin, deepwater Gulf of America (Gulf of Mexico) during the University of Texas (UT) Deepwater Hydrate Coring Expedition (UT-GOM2-2). Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were recovered. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of about 200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. These ooze intervals also correspond to lighter sediment color, increased Ca content based on X-ray florescence (XRF) core scanning, and increased calcareous nannofossil abundance. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years), with a pronounced increase in sedimentation rate with depth. Below 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C1 /C2 ) and the methane to ethane plus propane (C1 /(C2 +C3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ13C isotopic signature of methane ranges between -69.9 and -78.5 ‰ relative to the Vienna Pee Dee Belemnite (VPDB) standard. Pressure core recovery in sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One pressure core was degassed and the average hydrate saturation in the core was determined to be 24%. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Activity and selectivity for CO 2 methanation of clusters and nanoplates of ruthenium dispersed on ceria: In-situ studies with XAFS and DRIFTS

The performance of Ru/CeO 2 catalysts under CO 2 hydrogenation conditions was studied using in situ X-ray absorption fine structure (XAFS) and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) to understand the structural evolution and chemical nature of each component under reaction conditions. The catalysts were prepared using a reverse microemulsion method that maximized the dispersion of RuOx particles on ceria. A RuO x → Ru transformation was observed upon exposure of the RuO x /CeO 2 systems to H 2 at 250 °C. For a sample with 5% molar Ru, two-dimensional clusters (2-4 atoms) of Ru formed on top of the ceria support. An increase in the loading of ruthenium to 20% molar led to the formation of nanoplates of the metal 2-3 atomic layers thick. Both Ru structures were highly dispersed on ceria. They were oxidized after exposure to CO 2 at 250 °C. However, under CO 2 /H 2 mixture, they remained in a metallic state as two-dimensional clusters and nanoplates. In situ DRIFTS studies, the 5% and 20% Ru/CeO 2 catalysts showed distinct reaction intermediates when exposed to CO 2 or CO 2 /H 2 (1/4) reaction mixtures. Normalized to the Ru molar percentage, the 5% Ru/CeO 2 system was the most active catalyst exhibiting a selectivity of ~ 60% CH 4 and 40% CO at 250 °C. On the other hand, under the same reaction conditions, the 20% Ru/CeO 2 system was less active but had a CH 4 selectivity close to 80%. In conclusion, these results highlight the importance of the structure of the metallic Ru particles as a factor that determines the catalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of in-situ and ex-situ ion-irradiated additively manufactured 316L and 316H stainless steels

Additively manufactured (AM) 316 stainless steel (SS) differs from its wrought counterpart in its unique dislocation cell structure and the presence of segregation and oxide particles at the cell walls. This work investigated the evolution of the microstructure in laser powder bed fusion (LPBF) 316L and 316H SS under in-situ 1 MeV Kr ion irradiation at 600 °C to 5 dpa, and ex-situ 4 MeV Ni ion irradiation at 300 °C and 600 °C from 0.2 dpa to 10 dpa, with a dose rate for all experiments of 10 -3 dpa/s. The results reveal that the dislocation cell structure results in heterogeneous formation of dislocation loops and voids, particularly at 600 °C, where loops tend to form within the cell interiors while voids form at the cell boundaries. LPBF 316H has a reduced level of swelling compared to LPBF 316L due to prolonged incubation. Energy Dispersive X-ray Spectroscopy (EDS) mapping indicates Ni and Si segregation at void surfaces due to radiation-induced segregation. At 300 °C, where voids are absent, the distribution of dislocation loops and stacking fault tetrahedra appears to be uniform. Dislocation cell structures mostly disappeared by 2 dpa for all conditions in this work. M 23 C 6 carbides were observed in LPBF 316H at 600 °C as early as 0.2 dpa, but not in LPBF 316L. Nanoindentation was performed to obtain the hardness of irradiated materials. In conclusion, this work illustrated the influence of additive manufacturing processes on microstructure evolution under irradiation, revealing the differences as well as the similarities as compared with wrought 316 SS, and the AM-related phenomenon that can potentially occur under neutron irradiation in nuclear reactors.

36 - MATERIALS SCIENCE↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Fe-single atom catalysts facilitate fast electron transfer with MoS 2 /SnS 2 cathodes in lithium–sulfur batteries

Lithium–sulfur batteries (LSBs) emerge as promising next-generation energy storage systems offering cost-effectiveness, environmental friendliness, and high theoretical energy density. The practical implementation of LSBs faces significant hindrances due to the shuttle effect and sluggish redox reactions. To address these challenges, single-atom catalyst (SAC) based combination materials from d-block elements can offer increased active catalytic sites, rapid charge transfer, accelerated electron migration, and fast sulfur redox conversion kinetics of lithium polysulfides (LiPSs). In this study, we fabricated three different LSB cathodes: pure S, S@MoS 2 /SnS 2 , and S@Fe–MoS 2 /SnS 2 . These cathodes were then used to explore the cycle life, capacity, rate capability, and redox kinetic reactions of LiPSs while assessing the influence of Fe-SACs on their performance. As a result, LSBs with S@Fe–MoS 2 /SnS 2 cathodes demonstrate an extended cycle life of 1000 cycles at a C-rate of 0.2C, maintaining a capacity close to 500 mA h g −1 , the highest initial discharge capacity of 1622 mA h g −1 and 1066 mA h g −1 at 0.05C and 0.2C, and excellent rate capabilities of 708 mA h g −1 and 558 mA h g −1 at 1C and 2C, respectively. The synergistic effect of the Fe-SAC-based combination cathode (S@Fe–MoS 2 /SnS 2 ) creates plentiful adsorptive and highly active catalytic sites, resulting in substantially enhanced capacity for adsorbing soluble long-chain LiPSs. This facilitates ultra-fast redox kinetics, surpassing the performance of the S@MoS 2 /SnS 2 and pure S cathodes. In the ex situ analysis, results from powder X-ray diffraction (XRD) to observe the new phase, soft X-ray absorption spectroscopy (XAS) to investigate the electronic structure, and hard X-ray photoelectron microscopy (HAXPES) with different energies (900 eV, 2000 eV, and 6000 eV) to track the chemical-state evolution of Fe-SACs in MoS 2 /SnS 2 cathodes displayed notable electrochemical reversibility involving S 8 ⇄ LiPSs ⇄ Li 2 S conversion even after 1000 cycles. Additionally, in situ, operando Raman analysis can unveil a novel catalytic mechanism of Fe-SACs in MoS 2 /SnS 2 “facilitating rapid electron transfer” during the discharge and charge processes of LSBs involving the conversion of S 8 ⇄ long-chain LiPSs ⇄ Li 2 S 2 /Li 2 S. This study elucidates the working mechanism of Fe-SAC cathodes, offering insights into overcoming the shuttle effect and facilitating sulfur redox kinetics to advance commercial LSBs.

36 MATERIALS SCIENCE↗