Search NASA⌕ Search

SEARCH · Search NASA

Results for “independent system operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Capacity Markets for Transactive Energy Systems

Capacity markets provide important incentives for resource adequacy in electricity markets and may become more important for providing sufficient revenue and generation capacity with changes to energy market prices driven by increasing levels of zero marginal cost resources. However, current capacity market designs also have important shortfalls that may limit the benefits they can provide to the future grid. Current capacity markets are primarily designed for participation from conventional thermal generators, but markets are evolving with increasing levels of variable renewable energy resources. However, further reforms may be necessary to enable more participation from DERs and demand-side resources. To understand the benefits and shortfalls of current capacity market design, we review the historical reasons electricity markets have needed capacity markets or capacity payments for resource adequacy, and how current capacity market designs may create challenges for incorporating increasing levels of DERs and demand-side resources. We then consider how transactive systems, which allow the coordination of bids and offers for DERs and demand-side resources through a market interaction approach, administered by a Distribution System Operator (DSO), can address traditional resource adequacy problems due to inelastic consumer demand. We also consider the need for a DSO-level capacity market in helping to meet resource adequacy, reliability, and other electricity market objectives. We find that because the missing money in electricity markets is largely driven by incentives to meet resource adequacy goals, and the bulk grid would always supply power to the DSO, that resource adequacy is unlikely to be a determining factor in the need for a DSO-level capacity market. Many current reliability problems could also be addressed by the incorporation of more flexible demand enabled with transactive energy systems. However, other DSO objectives, including resilience, reactive power, voltage control, environmental policies, and energy equity could lead to specific challenges that could be aided by a DSO-level capacity market. We consider the possibility of a DSO-level capacity market in addressing these challenges as well as its potential role in coordinating with the Independent System Operator (ISO) who operates the wholesale market. We conclude with suggestions for future research, including the need to develop analytical models of DSO-level capacity market designs to address these potential objectives and examine their implications for DSOs and consumers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

A Market Feedback Framework for Improved Estimates of the Arbitrage Value of Energy Storage Using Price-Taker Models

Price-taker (PT) models are often used to assess the potential value or revenue of energy arbitrage opportunities for energy storage in wholesale markets. But as greater amounts of energy storage are deployed on the grid, current PT models fail to predict the effects that energy storage itself can have on market prices. This can lead to an overestimation of the economic value of storage and an inability to capture price suppression. In this paper, we propose the use of a modified PT model to simulate the impact of increased storage deployment on energy prices and the resulting impact on revenue. Our method uses a gradient-boosting regressor to estimate the impact on prices, and we apply our method on historical price data from the PJM and California Independent System Operator wholesale markets. We use this approach to explore possible causes of electricity price suppression that occur from storage capacity additions, which is generally not possible with PT models.

arbitrage↗

Sizing ramping reserve using probabilistic solar forecasts: A data-driven method

Ramping products have been introduced or proposed in several U.S. power markets to mitigate the impact of load and renewable uncertainties on market efficiency and reliability. Current methods often rely on historical data to estimate the requirements of ramping products and fail to take into account the effects of the latest weather conditions and their uncertainties, which could lead to overly conservative or insufficient requirements. This study proposes a k-nearest-neighbor-based method to give weather-informed estimates of ramping needs based on short-term probabilistic solar irradiance forecasts. Forecasts from multiple sites are employed in conjunction with principal component analysis to derive numerical classifiers to characterize system-level weather conditions. In addition, we develop a data-driven method to optimize the model parameters in a rolling-forward manner. By using real-world data from the California Independent System Operator, we design two metrics to evaluate method performance: 1) frequency of shortage and 2) oversupply of ramping product. Our proposed method presents advantages in comparison with the baseline and a set of benchmark methods: without compromising system reliability, it reduces system ramping requirements by up to 25%, therefore improving both system reliability and economics.

14 SOLAR ENERGY↗

Market analysis for the integration of new power technologies: A case study of the deployment of hybrid fossil-based generator plus energy storage (ES-FE)

This study examines the national landscape of hybridized fossil energy (FE) power plants with energy storage (ES) technologies (“ES-FE”) and presents the compilation of an ES-FE dataset, which includes over 65 ES-FE projects and concepts in the United States, comprising approximately 500 MWh of co-located ES capacity with FE power plants. This study also estimates the economic feasibility of adding ES to existing FE power plants by characterizing the potential revenues that can be generated by the ES component through flexibility and capacity value. The analysis focuses on ES technologies with 2- to 10-h. durations located in four U.S. independent system operators (ISOs): Midcontinent ISO (MISO), Electric Reliability Council of Texas (ERCOT), PJM Interconnection (PJM), and California ISO (CAISO), which have +70,000 MW of combined FE power capacity that could add ES. Annual revenues are estimated for the ES component using a what-if-analysis approach, for capacity value, price arbitrage, or ancillary services provision. The results show that annual revenues depend on the end-use storage service, wholesale electricity and capacity market prices, and ES technology operation parameters such as discharging duration and cycling frequency. When performing a sensitivity analysis, ES accrues $7–178/kW-yr. via price arbitrage and ancillary services provision in the four ISOs, and $13–92/kW-yr. when providing capacity value only in MISO and PJM. A cash flow analysis is performed to estimate the net present value (NPV) of the ES addition using a range of ES costs. The study finds that for most ES technologies considered, these revenues alone are insufficient to achieve economic feasibility. In conclusion, of the 1645 total runs analyzed, 115 had positive NPVs (7%). Therefore, other revenue streams or monetizable benefits are necessary to achieve the break-even point.

20 FOSSIL-FUELED POWER PLANTS↗

Benchmarking thermal energy storage cost for industrial process heat

Process heat accounts for roughly half of industrial energy demand, and currently 95% of process heat is derived from the combustion of natural gas, oil, and coal. Electrification of industrial heating could be an alternative, potentially expanding locations suitable for manufacturing; however, industrial facility owners may desire energy storage to stabilize energy costs. In this work, the economic benefits of pairing thermal storage with electrified process heat to reduce the average price paid for energy are analyzed. Cost savings focus on energy arbitrage, or leveraging flexible energy pricing schemes, alone. The cost of natural gas combustion across decades (2019-2060) is compared to the costs of electricity and thermal energy storage in four United States Independent System Operator (ISO) regions. Systems installed today may not yield positive net present value (NPV) compared to the use of natural gas. However, using estimated electricity prices, systems installed in 2030 using arbitrage alone could be profitable when compared to natural gas in some regions of the U.S. Furthermore, if capital expenditures could be reduced by 50% for sensible thermal storage systems by 2030, profitable systems are found across all regions. This implies that electrification of industrial process heat, when paired with inexpensive thermal energy storage systems, could be less expensive than brownfield natural gas systems, using arbitrage as the only source of revenue and without a dependency on any future policy drivers such as pricing externalities that could further incentivize the electrification of industrial process heat.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal scheduling for profit maximization of energy storage merchants considering market impact based on dynamic programming

This paper analyzes how electricity merchants' market impact affects merchants' profit. Energy storage has long been studied for its role in maximizing profit, and merchant decisions are assumed to have no impact on market prices. However, the trading decisions of large-scale energy storage merchants (e.g., pumped storage hydro) will affect the market prices. This paper employs dynamic programming theory to investigate merchants' optimal economic dispatch considering the market impact and physical characteristics of storage systems. Our findings show that the State-of-Charge (SOC) based analytical solution significantly facilitates energy storage merchants' decision-making. The SOC range is segmented into three regions by two optimal SOC reference points, which depend on the available energy in storage, given prices, and market impact. By comparing the current storage SOC with the reference points, the merchant can get the corresponding optimal actions. We analytically show that if the merchant neglects the market impact on the power market, she will exaggerate her expected profit when the price-taker and price-maker merchants have the same generating and pumping upper limits offered to Independent System Operators (ISOs). Furthermore, the profit-maximizing merchant must, therefore, assay to balance the trade-off correctly between the intensity of market impact and the dispatched power. Our findings are verified by numerical simulation, and results demonstrate the ramifications for electricity merchants in energy arbitrage decisions.

25 ENERGY STORAGE↗

A reforecasting-based dynamic reserve estimation for variable renewable generation and demand uncertainty

The installed capacity of renewables-based energy sources has been increasing in traditional power systems. In order to accommodate the increased variability and uncertainty associated with the deeper penetration of renewable sources like solar and wind, adjusted amounts of dynamic reserve are needed. Although probabilistic dynamic reserve estimation methods have been previously developed, most of them consider the uncertainty to be represented by parametric density functions that tend to perform poorly under extreme events and, moreover, neglect uncertainty introduced by the forecasting model itself. Toward addressing these limitations, this work presents, for the first time, a dynamic reserve estimation method for flexibility that incorporates nonparametric density estimation and a machine learning based reforecasting to provide a day-ahead prediction of the mean and spread of uncertainty around the base forecast. The prediction is, in turn, used to estimate the up and down reserve relative to the base forecast. Here, the present method takes various endogenous and exogenous features, including the calendar variables, as input to estimate the day-ahead reserve. Using a combination of reforecasting and dynamic reserve estimation techniques, the method is shown to adjust better to the dynamic nature of reserve requirements providing only what is needed to accommodate the expected deviations. Considering California Independent System Operator (CAISO) solar, wind and load data over an 18 month period, up to 67% reduction in the amount of reserve capacity needed for a one day reserve and reserve penalty for solar uncertainty is demonstrated. Additionally, the risk of reserve insufficiency in meeting the net demand is reduced by 20% with the proposed method.

14 SOLAR ENERGY↗

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Complementary relationship between small-hydropower and increasing penetration of solar photovoltaics: Evidence from CAISO

To achieve the 100% green electricity goal, we need to understand the relationship between resources in the market and identify the flexible clean resources (i.e., hydropower) to integrate power from wind and photovoltaic (PV). This paper reveals a complementary relationship between small hydropower plants and solar PVs in the California Independent System Operator (CAISO) based on the system-wide hourly generation data from 2013 to 2017. When the solar PV increases its portion in the generation mix by 1%, small hydro will increase its portion by 0.01–0.06%. Such response is obvious in the net demand peak hours, both morning and evening. The low operation cost, flexibility, and dispatchability of small hydro in CAISO explain this complementarity. Due to its benefit in emission and low Levelized Cost of Electricity (LCOE), it is suggested to consider more small hydro projects to accommodate additional PV capacity for the 100% green electricity goal. Our estimation indicates that the current feasible potential of small hydro is sufficient, if the relation stays the same over years. If developers can mitigate the environmental impact, more technical potential will become feasible. Thus, small hydro could integrate more solar PV and reduce the demand for natural gas plants and batteries.

13 HYDRO ENERGY↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-parametric analysis for mixed integer linear programming: An application to transmission upgrade and congestion management

Upgrading the capacity of existing transmission lines is essential for meeting the growing energy demands, facilitating the integration of renewable energy, and ensuring the security of the transmission system. This study focuses on the selection of lines whose capacities and by how much should be expanded from the perspective of the Independent System Operators (ISOs) to minimize the total system cost. We employ advanced multi-parametric programming and an enhanced branch-and-bound algorithm to address complex mixed-integer linear programming (MILP) problems, considering multi-period time constraints and physical limitations of generators and transmission lines. To characterize the various decisions in transmission expansion, we model the increased capacity of existing lines as parameters within a specified range. This study first relaxes the binary variables to continuous variables and applies the Lagrange method and Karush-Kuhn-Tucker (KKT) conditions to obtain optimal solutions and identify critical regions associated with active and inactive constraints. Moreover, we extend the traditional branch-and-bound (B&B) method by determining the problem’s upper and lower bounds at each node of the B&B decision tree, helping to manage computational challenges in large-scale MILP problems. Here, we compare the difference between the upper and lower bounds to obtain an approximate optimal solution within the decision-makers’ tolerable error range. In addition, the first derivative of the objective function on the parameters of each line is used to inform the selection of lines for easing congestion and maximizing social welfare. Finally, the capacity upgrades are selected by weighing the reductions in system costs against the expense of upgrading line capacities. The findings are supported by numerical simulations and provide transmission-line planners with decision-making guidance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal energy storage portfolio for high and ultrahigh carbon-free and renewable power systems

Achieving 100% carbon-free or renewable power systems can be facilitated by the deployment of energy storage technologies at all timescales, including short-duration, long-duration, and seasonal scales; however, most current literature focuses on cost assessments of energy storage for a given timescale or type of technology. In this work, we use an optimization framework with high spatial and temporal resolution to simultaneously assess the variable renewable power deployment and the optimal storage portfolio for seven independent system operators in the United States. Results indicate that achieving high (75–90%) and ultrahigh (>90%) energy mixes requires combining several flexibility options, including renewable curtailment, short-duration, long-duration, and seasonal storage. For instance, carbon-free and renewable energy mix targets of up to 80% are achieved with economic curtailment and a combination of short- and long-duration energy storage for the performance and cost assumptions used. After that, there is a point between 80% and 95% where seasonal storage becomes cost-competitive, depending on the specific power system. Moreover, our results indicate that storage-to-storage operation—one storage device used to charge another storage device—and the decoupling of charging and discharging storage power capacity are cost-effective options for the integration of high and ultrahigh shares of carbon-free or renewable power sources. Additionally, the results from this study show that an 85% carbon-free or renewable energy mix can be achieved at a cost of avoided CO 2 emissions of US$66.0 per tonne or less, regardless of the power system.

25 ENERGY STORAGE↗

Smoke from 2020 United States wildfires responsible for substantial solar energy forecast errors

Abstract The 2020 wildfire season (May through December) in the United States was exceptionally active, with the National Interagency Fire Center reporting over 10 million acres ( > 40 000 km 2 ) burned. During the September 2020 wildfire events, large concentrations of smoke particulates were emitted into the atmosphere. As a result, smoke was responsible for ∼10%–30% reduction in solar power production during peak hours as recorded by the California Independent System Operator (CAISO) sites. In this study, we focus on a 9 d period in September when wildfire smoke had a profound impact on solar energy production. During the smoke episodes, hour-ahead forecasts utilized by CAISO did not include the effects of smoke and therefore overestimated the expected power production by ∼10%–50%. Here we use multiple observational networks and a numerical weather prediction (NWP) model to show that the wildfire events of 2020 had a significantly detrimental influence on solar energy production due to high aerosol loading. We find that including the contribution of biomass burning particles greatly improves the day-ahead solar energy bias forecast of both global horizontal irradiance and direct normal irradiance by nearly ∼50%. Our results suggest that a more comprehensive treatment of aerosols, including biomass burning aerosols, in NWP models may be an important consideration for energy grid balancing, in addition to solar resource assessment, as solar power reliance increases.

14 SOLAR ENERGY↗

A robust statistical analysis of the role of hydropower on the system electricity price and price volatility

Abstract Hydroelectric power (hydropower) is unique in that it can function as both a conventional source of electricity and as backup storage (pumped hydroelectric storage and large reservoir storage) for providing energy in times of high demand on the grid (S. Rehman, L M Al-Hadhrami, and M M Alam), (2015 Renewable and Sustainable Energy Reviews , 44 , 586–98). This study examines the impact of hydropower on system electricity price and price volatility in the region served by the New England Independent System Operator (ISONE) from 2014-2020 (ISONE, ISO New England Web Services API v1.1 .” https://webservices.iso-ne.com/docs/v1.1/ , 2021. Accessed: 2021-01-10). We perform a robust holistic analysis of the mean and quantile effects, as well as the marginal contributing effects of hydropower in the presence of solar and wind resources. First, the price data is adjusted for deterministic temporal trends, correcting for seasonal, weekend, and diurnal effects that may obscure actual representative trends in the data. Using multiple linear regression and quantile regression, we observe that hydropower contributes to a reduction in the system electricity price and price volatility. While hydropower has a weak impact on decreasing price and volatility at the mean, it has greater impact at extreme quantiles (>70th percentile). At these higher percentiles, we find that hydropower provides a stabilizing effect on price volatility in the presence of volatile resources such as wind. We conclude with a discussion of the observed relationship between hydropower and system electricity price and volatility.

13 HYDRO ENERGY↗